• Title/Summary/Keyword: Screw cap

Search Result 13, Processing Time 0.023 seconds

Separation and Determination of Cadmium in Blood Serum by Solvent Extraction and Atomic Absorption Spectrophotometry (용매추출과 원자흡수분광법에 의한 혈청시료중 카드뮴의 분리 및 정량)

  • Lee, Seok Ki;Joung, Chang Ung
    • Journal of the Korean Chemical Society
    • /
    • v.43 no.4
    • /
    • pp.401-406
    • /
    • 1999
  • Trace amount of cadmium was quantitatively extracted with 1% Aliquat 336-MIBK from 0.2M KSCN and 0.01M-HCl. Test tubes with a screw cap stopper were used for extraction in place of conventional separating funnels and organic solvents used were less dense than water. In this analysis, 22 times concentration effect was achieved with higher selectivity without interference. The detection limit of cadmium was 0.7ppb, therefore trace cadmium was easily analyzed by this method. The proposed method was applied to the determination of cadmium in blood serum and extraction mechanism was elucidated.

  • PDF

Bolted Bonding Method of Steel Pipe Pile and Cap (볼트식 강관말뚝 머리보강 방법)

  • 박영호;김성환;장용채
    • Geotechnical Engineering
    • /
    • v.14 no.6
    • /
    • pp.57-71
    • /
    • 1998
  • Present bonding methods which connect steel pipe and spread footing in pile foundation have been generally used. These methods however showed lots of difficulties in the quality control. A new bonding method, which is called 'Bolted Bonding Method(BBM)' , is developed. This method uses factory-made parts so that it may increase the degree of quality, and workability, and is being adopted in the Held concerned. The method is verified by the structural analysis and laboratory test and then a new design formula is proposed. In addition, a comparison test of the present methods and BBM are conducted to observe the applicability and economy of the latter. As results, it is observed that BBM shows 5 to 10 times faster in Held work and 9% to 50% cheaper in construction cost than the existing methods.

  • PDF

Rapid Preparation and Quality Control of $^{99m}Tc$-ECD, $MAG_3$ and MIBI using Microwave Heating and Sep-Pak Cartridges (마이크로웨이브와 Sep-Pak 카트리지를 이용한 $^{99m}Tc$-ECD, $MAG_3$, MIBI의 신속한 제조 및 정도관리)

  • Oh, Seung-Jun;Moon, Dae-Hyuk;Ryu, Jin-Sook;Lee, Hee-Kyung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.4
    • /
    • pp.430-438
    • /
    • 1999
  • Purpose: We evaluated a rapid preparation procedures for the labeling and quality control of $^{99m}Tc$-ECD, $MAG_3$, and MIBI using microwave heating and Sep-Pak cartridges. Materials and Methods: $^{99m}Tc$ labeling of ECD, $MAG_3$, and MIBI kit preparation was performed according to the package inserts with microwave heating modification. Heating time was 10-15 sec, and heating was performed with 3 mm plastic bottle with screw cap to prevent radiation contamination. Labeling efficiency was obtained with $C_{18}$ or Alumina N Sep-Pak cartridges. Results: The radiochemical purity of $93{\sim}96%$ for $^{99m}Tc$-ECD and $95{\sim}99%$ for $^{99m}Tc$-MIBI was obtained using Alumina N Sep-Pak cartridge. The optimum irradiation time of microwave method for 3 ml $^{99m}Tc$-labeled radiopharmaceutical solution was 10 sec for $^{99m}Tc$-ECD and $^{99m}Tc$-MIBI, and 15 sec for $^{99m}Tc-MAG_3$. The results of quality control data with Sep-Pak cartridges were well correlated with TLC method. The total preparation time of these radiopharmcaeuticals was $5{\sim}6min$ including quality control procedure. Conclusion: This study demonstrates that radiopharmaceuticals preparation by microwave heating and quality control by Sep-Pak cartridges can be efficiently utilized as an alternative to the recommended method by manufacturer's manual.

  • PDF