• Title/Summary/Keyword: Screening equipment

Search Result 82, Processing Time 0.029 seconds

Paint Spray Mass Spectrometry for the Detection of Additives from Polymers on Conducting Surfaces

  • Paine, Martin R.L.;Barker, Philip J.;Blanksby, Stephen J.
    • Mass Spectrometry Letters
    • /
    • v.3 no.1
    • /
    • pp.25-28
    • /
    • 2012
  • Paint Spray is developed as a direct sampling ionisation method for mass spectrometric analysis of additives in polymer-based surface coatings. The technique simply involves applying an external high voltage (5 kV) to the wetted sample placed in front of the mass spectrometer inlet and represents a much simpler ionisation technique compared to those currently available. The capabilities of Paint Spray are demonstrated herein with the detection of four commercially available hindered amine light stabilisers; TINUVIN${(R)}$770, TINUVIN${(R)}$292, TINUVIN${(R)}$123 and TINUVIN${(R)}$152 directly from thermoset polyester-based coil coatings. Paint Spray requires no sample preparation or pre-treatment and combined with its simplicity requiring no specialised equipment makes it ideal for use by non-specialists. The application of Paint Spray for industrial use has significant potential as sample collection from a coil coating production line and Paint Spray ionisation could enable fast quality control screening at high sensitivity.

Method for Measuring Weld Temperature Using an Infrared Thermal Imaging Camera (적외선 열화상 카메라를 이용한 용접부의 온도 측정 방법)

  • Ro, Chan-Seung;Kim, Kyeong-Suk;Chang, Ho-Seob
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.34 no.4
    • /
    • pp.299-304
    • /
    • 2014
  • In this paper, a method is tested to measure temperatures in high-temperature welds. Protective glass was installed between an infrared thermal imaging camera and a heat source, and temperature compensation was applied to the measuring instruments. When the temperature of halogen lamps was taken in real-time and measured by the thermal camera, the temperature was found to be almost invariant with the distance between the camera and heat source. The temperature range could be predicted, through correlations with the thickness of the protective glass and the measured distance. This study suggests that the temperature measurement of welds obtained by using an infrared thermal imaging camera is valid, through experimental testing of heat sources.

A Study on the Transmission Overload Relief by Fast Switching (고속 스위칭에 의한 송전선로 과부하 해소 연구)

  • Cho, Yoon-Sung;Lee, Han-Sang;Jang, Gilsoo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.8
    • /
    • pp.1053-1058
    • /
    • 2013
  • Because of computational burden and complex topology of substation, a transmission overload relief using circuit-breaker switching was very complex and difficult. However, a on-line algorithm for reducing the overloads in transmission lines has made progress due to the advance of IT technology. This paper describes the methodology for alleviating the overloads in transmission lines by circuit-breaker switching. First, the severe contingency lists and substations were selected from the results of contingency analysis. Then the switch combinations are determined using circuit-breakers of the selected substation. The topology changes are limited to equipment outage, bus split, island split, bus merge and island merge. Finally, the fast screening and full analysis methods are used to analyze the overload in transmission lines. To verify the performance of the proposed methodology, we performed a comprehensive test for both test system and large-scale power systems. The results of these tests showed that the proposed methodology can accurately alleviate the overloads in transmission lines from online data and can be applied to on-line applications.

Corrosion Assessment by Using Risk-Based Inspection Method for Petrochemical Plant - Practical Experience

  • Choi, Song-Chun;Song, Ki-Hun
    • Corrosion Science and Technology
    • /
    • v.8 no.3
    • /
    • pp.119-125
    • /
    • 2009
  • Corrosion assessment has a number of uses but the use considered here is as a precursor to Risk-Based Inspection (RBI) planning. Systematic methods consisting of technical modules of RBI program were used to assess the effect of specific corrosion mechanism on the probability of failure in equipments of petrochemical plants. Especially in part of the damage and corrosion assessment, screening step involved evaluating the combinations of process conditions and construction materials for each equipment item in order to determine which damage mechanisms are potentially active. For general internal corrosion, either API 510 or API 570 was applied as the damage rate in the calculation to determine the remaining life and inspection frequency. In some cases, a measured rate of corrosion may not be available. The technical modules of RBI program employ default values for corrosion, typically derived from published data or from experience with similar processes, for use until inspection results are available. This paper describes the case study of corrosion and damage assessment by using RBI methodology in petrochemical plant. Specifically, this paper reports the methodology and the results of its application to the petrochemical units using the $KGS-RBI^{TM}$ program, developed by the Korea Gas Safety Corporation to suit Korean situation in conformity with API 581 Codes.

CO2 Absorption Characteristics of Physical Solvent at High Pressure (고압에서 물리흡수제의 이산화탄소 흡수 특성 연구)

  • Eom, Yongseok;Kim, Eunae;Kim, Junhan;Chun, Sungnam;Lee, Jungbin
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.24 no.4
    • /
    • pp.334-339
    • /
    • 2013
  • In this study, as a candidate of the carbon dioxide ($CO_2$) absorbents, the mixture solution of polyethylene glycol dimethyl ether (PEGDME) and tetrahydrofuran (THF) were investigated. $CO_2$ absorption rate was measured by using high pressure $CO_2$ screening equipment in the range of 1 - 10wt% THF. Absorption capacity of the mixture solution was also estimated. Based on the results, we found that mixture solution containing THF had higher absorption rate and $CO_2$ loading capacity compared to PEGDME at $25^{\circ}C$.

The recent trend and determinants of service diversification in Korean hospital (우리나라 병원의 서비스 다각화추세와 관련요인분석)

  • Lee, Sun-Hee;Kim, Han-Joong;Cho, Woo-Hyun
    • Journal of Preventive Medicine and Public Health
    • /
    • v.24 no.1 s.33
    • /
    • pp.16-28
    • /
    • 1991
  • Service diversification is recognized as an important strategy against turbulent environmental change. This study is designed to find out the trend of service diversification in Korean health care organizations and also to identify factors associated with the degree of service diversification. Data were collected from 69 hospitals out of 71 hospitals with over 300 beds. Important findings are summarized below. 1. Types of diversification are closely related to hospital size. Large hospitals have a tendency to provide sophisticated services requiring specialized skills and equipment, while small hospital have concentrated their efforts on health screening programs. 2. The more competitive and bigger hospitals are, the greater number of services that provide. Also, hospitals operating rational management information systems provide more services. Contrary to the expectation hospitals with a low performance during last 3 years showed more service diversification. 3. A trend of more diversification was observed in hospitals whose chief executive officer used a prospector strategy. 4. A multiple regression analysis revealed that bed size, competitive environment, degree of rational management, and the growth pattern were significantly associated with the service diversification.

  • PDF

Random Vibration Analysis for Satellite Design (위성체 설계를 위한 랜덤 진동 해석)

  • Lee, Won-Beom;Kim, Gyeong-Won
    • Aerospace Engineering and Technology
    • /
    • v.5 no.2
    • /
    • pp.102-107
    • /
    • 2006
  • In this study, the dynamic environment of satellite consists of excessive vibration at low frequency and irregular acceleration transferred by launch vehicle structure. Excessive vibration at low frequency is generally approximated by a sinusoidal wave from 100Hz to 200Hz and primarily used to preliminary design The random vibration is created by structural vibration due to the combustion of launch vehicle, separation stage and external aerodynamic noise. these are transferred to the adapter structure between satellite and launch vehicle through the structure of launch vehicle. random vibration is being specified for acceptance tests, screening tests, and qualification tests, because it has been shown that random vibration more closely represents the true environments in which the electronic equipment must operate.

  • PDF

Fabrication of Multicomponent Protein Microarrays with Microfluidic Devices of Poly(dimethylsiloxane)

  • Jeon, Se-Hoon;Kim, Ui-Seong;Jeon, Won-Jin;Shin, Chee-Burm;Hong, Su-Rin;Choi, In-Hee;Lee, Su-Seung;Yi, Jong-Heop
    • Macromolecular Research
    • /
    • v.17 no.3
    • /
    • pp.192-196
    • /
    • 2009
  • Recently, the multi-screening of target materials has been made possible by the development of the surface plasmon resonance (SPR) imaging method. To adapt this method to biochemical analysis, the multi-patterning technology of protein microarrays is required. Among the different methods of fabricating protein microarrays, the microfluidic platform was selected due to its various advantages over other techniques. Microfluidic devices were designed and fabricated with polydimethylsiloxane (PDMS) by the replica molding method. These devices were designed to operate using only capillary force, without the need for additional flow control equipment. With these devices, multiple protein-patterned sensor surfaces were made, to support the two-dimensional detection of various protein-protein interactions with SPR. The fabrication technique of protein microarrays can be applied not only to SPR imaging, but also to other biochemical analyses.

Digital X-Ray Technology and Applications (디지털 엑스선 기술과 응용)

  • Jeong, J.W.;Kang, J.T.;Kim, J.W.;Park, S.;Lee, M.L.;Song, Y.H.
    • Electronics and Telecommunications Trends
    • /
    • v.34 no.5
    • /
    • pp.1-13
    • /
    • 2019
  • In modern times, X-ray imaging has become a necessary tool for early diagnosis, quality control, nondestructive testing, and security screening. X-ray imaging equipment generally comprises an X-ray generator and an image sensor. Most commercially available X-ray generators employ filament-thermionic electron-based X-ray tubes, thus demonstrating typical analog behavior, such as slow response and large stray X-rays. Furthermore, digital X-ray sources, which have been studied extensively using field electron emitters manufactured from nanometer-scale materials, provide fast and accurately controlled ultra-shot X-rays. This could usher in a new era of X-ray imaging in medical diagnosis and nondestructive inspections. Specifically, digital X-ray sources, with reduced X-ray dose, can significantly improve the temporal and spatial resolution of fluoroscopy and computed tomography. Recently, digital X-ray tube technologies based on carbon nanotubes, developed by Electronics and Telecommunications Research Institute, have been transferred to several companies and commercialized for dental imaging for the first time.

Development of Aging Diagnosis Device Through Real-time Battery Internal Resistance Measurement

  • Kim, Sang-Bum;Lee, Sang-Hyun
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.14 no.2
    • /
    • pp.129-135
    • /
    • 2022
  • Currently, the rapid growth of electric vehicles and the collection and disposal of waste batteries are becoming a social problem. The purpose of this paper is to propose a fast and efficient battery screening method through a safe inspection and storage method according to the collection and storage of waste batteries of electric vehicles. In addition, as the resistance inside the waste battery increases, an instantaneous voltage drop occurs, and there is a risk of overcharging and overdischarging compared to the initial state of the battery. Accordingly, there are great difficulties in operation, so the final goal of this study is to develop a device for diagnosing aging through real-time battery internal resistance measurement. Final result As a result of simulation of the internal resistance measurement test circuit through external impedance (AC), the actual simulation value was 0.05Ω, RS = Vrms / Irms => Vrms = 8.0036mV, Irms = 162.83Ma. Substitute the suggested method. The result was calculated as Rs = 0.0495Ω. It is possible to measure up to 64 impedances inside the aging diagnostic equipment that enables real-time monitoring of the developed battery cells, and the range can be changed according to the application method.