• Title/Summary/Keyword: Screen wick

Search Result 35, Processing Time 0.029 seconds

Comparison of the Heat transport Limitations for Screen Mesh Wick and Sintered Metal Wick Heat Pipes by Theoretical Analysis (이론적 해석에 의한 스크린 메쉬윅과 소결윅 히트파이프의 열수송 한계 비교)

  • Kim Keun-Bae;Kim Yoo
    • Journal of Energy Engineering
    • /
    • v.13 no.4
    • /
    • pp.267-274
    • /
    • 2004
  • Theoretical analysis for predicting the heat transport limitations of screen mesh wick and sintered wick heat pipes was performed. The heat pipe diameter was 8mm and water was used for working fluid. For the 250 mesh, each capillary pressures and heat transport limitations, thermal resistances were analyzed according to the operating temperatures, wick thicknesses and inclination angles, based on the effective capillary radius (r$\_$c/), porosity ($\varepsilon$) and permeability (K). The wick capillary limitation was increased as the operating temperature and the wick thickness were increased, and generally the sintered wick showed higher heat transport limitations than that of the screen wick. The thermal resistance of the screen wick was higher than that of the sintered wick and both thermal resistances were linearly increased as the wick thickness was increased.

Theoretical Analysis of Heat Transportation Limitation by Porosity of Wick in Screen Mesh Wick Heat Pipe (스크린메쉬윅 히트파이프에서 윅의 기공율변화에 따른 열수송한계의 이론적 고찰)

  • Lee, Ki-Woo;Park, Ki-Ho;Chun, Won-Pyo;Lee, Wook-Hyun
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.1-6
    • /
    • 2003
  • The purpose of the present study is to investigate the capillary heat transportation limitation in heat pipe according to the change of screen mesh wick porosity. Diameter of pipe was 6 mm, and mesh numbers are 100, 150, 200 and 250 and water was selected as a working fluid. According to the change of wick porosity and mesh number, the capillary pressure, pumping pressure, liquid friction coefficient in wick, vapor friction coefficient, and capillary heat transportation limitation are analyzed by theoretical design method of a heat pipe. As some results, the capillary heat transportation limitation in screen mesh wick heat pipe is largely affected by wick porosity and mesh number.

  • PDF

Theoretical Analysis of Factors Affecting to Heat Transfer Limitation in Screen Mesh Wick Heat Pipe (스크린 메쉬윅 히트파이프의 열전달한계에 영향을 미치는 인자의 이론적 해석)

  • 이기우;노승용;박기호
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.11
    • /
    • pp.880-889
    • /
    • 2002
  • The purpose of the present study is to examine the factors affecting the heat transfer limitations of screen mesh heat pipe for electronic cooling by theoretical analysis. Diameter of pipe was 6 mm, and mesh numbers are 50, 100, 150, 200 and 250 and water was selected as a working fluid. According to the change of mesh number, wick layer, inclination and saturation temperature, capillary pressure, pumping pressure, liquid friction coefficient in wick, vapor friction coefficient, capillary limitation, entrainment limitation, sonic limitation and boiling limitation we analyzed by theoretical design method of a heat pipe. As some results, the capillary limitation in small diameter of heat pipe is largely affected by mesh number and wick layer.

A Study on the Characteristics of Heat Transfer in Heat Pipe with Composition Wick of Screwed Groove - Metallic Mesh (나선형그루브-금망의 복합윅을 갖는 히이트파이프의 전열특성에 관한 연구)

  • Chang, Young-Suk;Lee, Young-Soo;Seoh, Jeong-Il
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.15 no.3
    • /
    • pp.273-282
    • /
    • 1986
  • The purpose of this research was to study the characteristics of heat transfer in Heat Pipe which used the composition wick of screened groove - metallic mesh by ADI method and experimental results. As the results, the more than number of metallic mesh screen layers in a heat pipe increased, the fewer the effect of heat recovery decreased. In case of 1 - layer metallic mesh screen wick, the response of the effect in heat recovery was more rapidly showed than in case of other layers and in spite of high load, the evaporation section of Heat pipe with 1 - layer metallic mesh screen wick showed the stable response and did not show excessive super heat. There was a interrelation between thermal resistance and the variable layers, between thermal resistance and the variable gaps of metallic meshes, the heat transfer characteristics of Heat pipe were depended on the thermal resistance of composition wick.

  • PDF

An Experimental Study on Heat Transfer Performances in 8mm-diameter Heat Pipes with Screen Mesh Wick (스크린 메쉬 윅을 삽입한 8mm 히트파이프에서 열전달 성능에 관한 실험적 연구)

  • Park, Ki-Ho;Lee, Ki-Woo;Noh, Seung-Yong;Lee, Kye-Jung;Yoo, Seong-Yeon
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.48-53
    • /
    • 2001
  • This experimental study is to research heat transfer characteristics in copper-water heat pipes with screen wick, the 150 and 200-mesh. Recent advances in the miniaturization and large capacity of electronic devices have had a major impact on the design of electronic equipment. As a result, a high-performance cooling system is needed. Experimental variables are inclination angle, number of layer and temperature of cooling water. The distilled water was used for the working fluid. At a inclination angle $6^{\circ}$, the 200-mesh screen wick 3-layer is shown the best heat transfer performance.

  • PDF

Theoretical Analysis of Heat Transport Limitation in a Screen Mesh Wick Heat Pipe

  • Lee, Ki-Woo;Park, Ki-Ho;Lee, Wook-Hyun;Rhi, Seok-Ho
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.12 no.1
    • /
    • pp.1-9
    • /
    • 2004
  • The purpose of the present study is to examine the heat transport limitations in a screen mesh heat pipe for electronic cooling by theoretical analysis. Diameter of pipe was 6mm, and mesh numbers were 50, 100, 150, 200 and 250, and water was investigated as working fluid. According to the change of mesh number, wick layer, inclination and saturation temperature, the maximum heat transport limitations by capillary, entraintment, sonic and boiling were analyzed by a theoretical design method of heat pipe, including capillary pressure, pumping pressure, liquid friction coefficient in wick, vapor friction coefficient, etc. Based on the results, the capillary limitation in a small diameter of heat pipe is largely affected by mesh number and wick layer. Mesh number of 250 is desirable not to be used in pipe diameter of 6 mm, because capillary heat transport limitation decreases by the abrupt increase of liquid friction pressure due to the small liquid flow area. For the heat transport of 15 watt in 6mm diameter pipe, mesh number of 100 and one layer is an optimum wick condition, which thermal resistance is the smallest.

Experimental Study on the Working Characteristic of Aluminum Grooved Heat Pipe and Thermosyphon with Inner Arterial Wick (내부 아터리가 있는 알루미늄 그루브 히트파이프와 써모사이펀의 작동특성에 관한 실험적 연구)

  • 홍진관;김대성;정원복
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.10
    • /
    • pp.894-900
    • /
    • 2000
  • The experimental study for performance improvement of aluminum/freon22 grooved heat pipe was carried out. Arterial wick was used for performance improvement of heat pipe. The experimental result was compared with screen covered grooved wick heat pipe. And also, performance test of grooved wick thermosyphon inserted straight wire in the center of grooved pipe was carried out. This result was compared with the performance test result of grooved wick thermosyphon. The operation limit of artery inserted grooved heat pipe was slightly extended, but thermal resistance of this heat pipe was twice as large as that of screen covered grooved heat pipe. In case of thermosyphon, the operation limit of grooved thermosyphon inserted straight wire in the center of grooved pipe was slightly extended, but thermal resistance was increased, comparing with that of the grooved thermosyphon.

  • PDF

An Experimental Study on the Heat Transfer Characteristics in Miniature Heat Pipes with Screen Wick (스크린 윅을 삽입한 소형 히트파이프에서 열전달 특성에 관한 실험적 연구)

  • Park, K.H.;Lee, K.W.;Ko, Y.K.;Lee, K.J.;Chun, W.P.
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.572-578
    • /
    • 2001
  • This study is to research the heat transfer characteristics in copper-water heat pipes with screen wick, #100. Recently, the semiconductor capacity of an electronic unit has been larger, on the contrary, its size is smaller than before. As a result, a high-performance cooling system is needed. Experimental variables are inclination angle and temperature of cooling water. The distilled water was used for the working fluid. At a inclination angle ${-6}^{\circ}$, #100 2layer screen mesh is shown the best heat transfer performance.

  • PDF

An Experimental Study on Ultrasonic Spray Cooling of Heat Pipe Condenser (히트파이프 응축부의 초음파 분무냉각에 관한 실험적 연구)

  • 김영찬;한양호
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.1
    • /
    • pp.77-83
    • /
    • 2004
  • In this study, the spray cooling heat transfer and working characteristics of the screen wick heat pipe with ultrasonic spray cooling system in condenser were experimentally investigated. The heat pipe was made of copper tube 300 mm long with inner diameter of 11.1 mm. The evaporator and condenser lengths of heat pipe were 40, 200 mm and the wick structure consists of two layer of 100 mesh copper screen. The experimental results show that the ultrasonic spray cooling increases the heat transfer rate on the condenser surface, and the total thermal resistance of heat pipe system decreases remarkably. A comparison is made for the two working fluids, water and ethanol. The surface temperature of the ethanol tube in evaporator section becomes higher than that of the water tube. Thus, the experimental result shows that water is more useful than ethanol as the working fluid because of increasing the operational limit within this experimental conditions.

Experimental Study of Heat Transfer Performance of Variable Conductance Heat Pipe with Screen Mesh Wick (Mesh Wick형 가변전열 히트파이프의 열전달 성능에 관한 실험적 연구)

  • Park, Y.S.;Byon, G.S.;Suh, J.S.;Park, K.H.;Lee, K.W.
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.7-12
    • /
    • 2003
  • heat pipe with screen meshed wick. The heat pipe was designed in 200 screen meshs, 500 mm length and 12mm O.D tube of copper, water as working fluid and nitrogen as non-condensible gas. Heat pipe used in this study has evaporator, condenser and adiabatic section, respectively. Experimental data of wall temperature distribution along axial length is presented for heat transport capacity, condensor cooling water temperature change, degrees of an inclination angle, and operating temperature.

  • PDF