• 제목/요약/키워드: Screen clogging

검색결과 8건 처리시간 0.02초

발전소 취수구에 대량으로 유입하는 해양생물에 대한 스크린 설비의 성능분석 (Performance Analysis of Intake Screens in Power Plants on Mass Impingement of Marine Organisms)

  • 이재학;최현우;채진호;김동성;이승백
    • Ocean and Polar Research
    • /
    • 제28권4호
    • /
    • pp.385-393
    • /
    • 2006
  • Screening performance of the existing intake screens (drum and travelling screen) on mass impingement of marine animals, a euphausiid, Euphausia pacifica and a scyphozoan medusae, Aurelia aurita that have often clogged intake screens of the Uljin Nuclear Power Plant, was tested. The maximum tolerable densities of marine animals in the inflowing seawater upon the screen were estimated with two different approaches. First the maximum density of jellyfish was calculated from (1) passing amount of seawater per unit time through the screens and (2) the covered area of animals on the screens clogged. The maximum density of krill tolerable in the drum screen was cited from a simulated record of Uljin NPP, then those in the travelling screens were also calculated using the data of drum screen and ratio of seawater amount passing through the screens under the condition of 0.5m water column (W.C.) of the differential pressure (AP) produced by screens, an established permissible limit of ${\Delta}P$. Secondly, the screening performances were also tested by hydrodynamic measurements with various screen models in a circulating water channel equipped with a speed-controlling pump and a differential pressure gauge. From the first approach, the maximum tolerable densities of drum and travelling screen were calculated as 2.0 and $1.5ind/m^3$ for the Jellyfish and 900 and $680ind./m^3$ for the euphausiid, respectively. These densities estimated from the second approach were 2.1 and $0.8ind/m^3$ for the jellyfish and 1059 and $504ind/m^3$ for the euphausiid, respectively. These estimates were compared with the data from historic clogging events to evaluate the practical performance of these intake screens. The comparisons suggest a newly improved intake-screen of which performance should be at least seven times (approximately) better than the existing ones ior the krill and 3.2 times for the jellyfish, respectively, for preventing mass impingement, and for maintaining the condition of the differential pressure between the screens below 0.3 m W.C.

Iron and manganese removal in direct anoxic nanofiltration for indirect potable reuse

  • Jin, Yongxun;Choi, Yeseul;Song, Kyung Guen;Kim, Soyoun;Park, Chanhyuk
    • Membrane and Water Treatment
    • /
    • 제10권4호
    • /
    • pp.299-305
    • /
    • 2019
  • Managed aquifer recharge (MAR) systems are gaining interest as an alternative to conventional water resources. However, when the water recovered in MAR systems, dissolved iron and manganese species may easily oxidize and they cause well screen clogging or require abandonment of extraction wells. In this study, both oxic and anoxic conditions were analyzed to verify the feasibility of the membrane filtration performance under various solution chemistries. The fouling mechanisms of the metal ions under anoxic conditions were also investigated by employing synthetic wastewater. The fouled membranes were then further analyzed to verify the major causes of inorganic fouling through SEM and XPS. The newly suggested anoxic process refining existing membrane process is expected to provide more precious information about nanofiltration (NF) membrane fouling, especially for demonstrating the potential advantages to chemical-free drinking water production for indirect potable reuse.

자동역세척 여과장치를 이용한 선박 밸러스트수 처리 (Development of Automatic Backwashing Treatment System for Ballast Water)

  • 박상호;임재동;김인수
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 2005년도 추계학술대회 논문집
    • /
    • pp.181-185
    • /
    • 2005
  • 선박에서 발생되는 밸러스트수를 전처리하기 위하여 수중에 포함되어 있는 입자상 오염물질과 수중생물체를 자동역세척 여과장치를 이용하여 처리한 결과를 나타내었다. 밸러스트수를 처리하기 위한 전처리의 장점은 입자상이 오염물질을 제거하여 후처리공정의 처리효과를 높이는데 있다. 여과필터를 회전하여 20RPM 에서는 40.5cmHg이고 40RPM 에서는 36.6cmHg이며 60RPM 이상에서는 35cmHg로 나타나 연속적으로 여과할 수 있었다. 필터의 막힘현상으로 역세 회복압력과 역세간격은 시간의 경과에 따라 조금씩 좁아지고 처리유량도 감소하는 것을 관찰할 수 있었다. 회분식 여과처리공정은 자동 역세척을 수행하는 공정에 비해서 처리효율의 저하가 일어났다. 여과처리를 통하여 $80{\mu}m$이상의 식물성 플랑크톤과 동물성 플랑크톤을 포함하는 수중생물체를 제거할 수 있었다. 연구결과를 통하여 밸러스트수 처리에 적용 가능한 기술임을 알 수 있었다.

  • PDF

반응표면분석법을 이용한 제진기의 목메임 방지 개선 및 레이크 최적화 (A Study on the Optimization of Anti-Jamming Trash Screen with Rake using by Response Surface Method)

  • 선상원;이원;홍석범
    • 한국산학기술학회논문지
    • /
    • 제21권3호
    • /
    • pp.230-236
    • /
    • 2020
  • 제진기는 배수펌프장, 하수처리장, 발전소 등 유입 수로 전단에 설치되어 부유 협잡물의 유입을 차단하는 장치이다. 제진기의 스크린 사이의 협잡물이 끼는 목메임 현상과 노끈류가 제거되지 못하여 물의 유입로의 감소 또는 제진기 파손을 유발하는 문제점이 발생하고 있다. 본 논문에서는 목메임과 노끈류 끼임으로 인한 파손이 주로 발생하는 에이프런을 제거하고 스크린을 확장하여 대체하였다. 그리고 스크린 사이 공간에 내측 레이크를 추가하여 목메임과 노끈류를 제거하도록 개선하는 확장형 레이크를 사용하는 방식으로 설계하였다. 기존의 제진기 레이크의 허용응력을 만족하는 내측 레이크를 설계하기 위하여 레이크 수직 길이와 보강단면의 두께 값을 변수로 하여 실험계획법에 따라 실험점을 결정하고, 구조해석 툴인 ANSYS static structural module과 통계분석 툴인 R software를 이용하여 반응표면분석법에 따른 형상 최적화를 진행하였다. 결정된 최적 설계점 레이크 길이 210.2mm와 보강단면 두께 2mm에서 반응표면분석법 결과와 구조해석의 결과의 상대 오차는 1.63% 이다. 파일럿 제진기를 실제 크기로 제작하여 실증 실험을 수행하였으며 97%이상 목메임과 노끈류를 제거가 가능함을 확인하였다.

폐잉크를 이용한 스크린 인쇄용 블랙 잉크 제조에 관한 연구 (A Study on the Manufacturing Process of Black Ink for Screen Printing by using Waste Ink)

  • 권희경;우진호
    • 한국인쇄학회지
    • /
    • 제28권2호
    • /
    • pp.87-99
    • /
    • 2010
  • The ink which is left by sealed more than 6 months, it clogs head nozzle of machine due to precipitation and coagulation. In addition, if you stop printing about 3~4 hours in the middle of printing work, the head nozzles of printer could be naturally clogged. To prevent of this situation, worker should implement cleaning and checking head nozzle before hands. When the nozzle is clogged in the middle of work, running a head cleaning mode can clear the clogged nozzle. Yet, large amount of waste inks which are passed clogged nozzle will be remained after cleaning. It would be very nice that ink companies take the waste ink back by green marketing, but none of them are doing it currently. The purpose of this research is that making a black water-based recycle ink by waste inks which are left of nozzle clogging or passed expiration date. This recycle ink will improved working environment and reduce cost of disposing waste inks. Furthermore, it is very environment friendly and economical. It is called a recycle ink which is water-based black ink made by waste inks.

소규모 밭 관개용수 확보를 위한 소류천 빗물 집수장치의 현장 평가 (On-site Evaluation of Rainwater Harvesting Device for Securing Irrigation Water in Small Fields)

  • 최용훈;김영진;김민영;전종길
    • 한국농공학회논문집
    • /
    • 제60권1호
    • /
    • pp.31-36
    • /
    • 2018
  • A rainwater harvesting device was developed for runoff flow harvesting in a small stream or channel and its performance was evaluated in small fields. The rainwater harvesting device has slits on its side of cylindrical volume in 15 cm diameter and 70 cm length, which is designed to increase its water flow harvesting capacity. The maximum collectable water quantity was about 0.0022 ton/sec (130 L/min). Rainwater harvesting device were installed in two locations (P1, P2). P1 is a point for rainfall runoff flow harvesting. P2 is a point for ordinary flow harvesting. During this study, total rainfall depth was 334.5 mm. Runoff of 1,722 ton and 7,984 ton occurred in P1 and P2, and 273 ton and 125 ton were collected by this rainwater harvesting device. Harvesting efficiency was calculated as 15.85 % and 1.57 % in P1 and P2. Clogging of screen filter media in the cylinder due to soil and suspended solids has lowered the harvesting efficiency. However, it was possible to harvest 30 ton/month of rainwater harvesting and it is expected that it will help to solve short-term water shortage.

고전압 펄스 방전을 이용한 지하수 관정 스크린 공막힘 재생법 연구 (Feasibility Study for the Cleaning of Well Screens using High-voltage Pulsed Discharge)

  • 정경재;이석근;당정증;최길환;황용석;김철영;박영준
    • 지질공학
    • /
    • 제23권1호
    • /
    • pp.29-36
    • /
    • 2013
  • 스크린 공막힘에 의하여 채수량이 감소된 지하수 관정은 여러 방법을 통하여 재생시켜주면 지하수 채수량을 개선시켜 관정의 수명을 연장할 수 있다. 본 논문에서는 화약이나 압축 유체를 사용하는 기존의 공막힘 재생기술을 대신할 수 있는 고전압 펄스 방전에 의한 지하수 관정 스크린 공막힘의 재생법에 대하여 연구하였다. 본 기술은 수중에 삽입된 전극에 순간적으로 고전압의 전기에너지를 주입하여 이 때 전극 사이에서 발생하는 고온, 고압의 플라즈마의 팽창력에 의하여 발생하는 수중 충격파를 이용하는 기술로, 기존 기술 대비 취급이 용이하며 구조가 간단하고 충격압의 크기 조절이 용이하다는 장점을 갖는다. 본 연구에서는 축전기 방전형 펄스 발생장치를 사용하여 약 200 J의 전기에너지를 수중에 삽입된 전극에 순간적으로 주입함으로써 전극으로부터 6 cm 떨어진 곳에서 약 10.7MPa의 수중 충격압을 얻었다. 이 충격압의 크기는 축전기의 충전 전압을 바꿔줌으로써 손쉽게 조절이 가능하였으며, 다양한 전압에서의 실험을 통하여 방전 전류의 첨두치와 선형적인 관계를 갖고 있음을 알았다. 또한 지하수 관정에 사용되는 스크린과 유사한 시료에 대한 모의실험을 통하여 이 기술을 이용한 지하수 관정의 세척 가능성을 확인하였다.

수평흐름식 여과기술의 CSOs 적용을 위한 공정 최적화 연구 (A Study on Process Optimization for CSOs Application of Horizontal Flow Filtration Technology)

  • 김재학;양정하;이영신
    • 한국산학기술학회논문지
    • /
    • 제19권2호
    • /
    • pp.56-63
    • /
    • 2018
  • 강우사상이 발생함에 따라 시설용량을 초과하여 미처리된 상태로 방류수계에 직접 배출되는 합류식 관거 월류수(Combimed Sewer Overflows, CSOs) 및 분류식 관거 월류수(Separated Sewer Overflows, SSOs)의 관리는 집중호우가 잦아지는 근래에 들어 그 관리가 더욱 중요해지고 있다. 밀집도가 높은 도심지에 적용성이 유리한 여과기술은 지속적인 개발이 이루어지고 있음에도 불구하고 CSOs에 적용된 사례가 거의 전무한 실정이다. 따라서 본 연구에서는 로프형 섬유여재가 적용된 Pilot 규모의 수평흐름식 여과장치를 CSOs에 적용하기 위해 공정최적화를 목적으로 수행되었다. 연구방법은 인공시료를 적용한 사전연구와 하수를 적용한 현장연구로 구분하여 수행하였다. 인공시료를 적용한 사전연구에서 여재 자체의 손실수두는 약 1.1cm정도로 분석되었고, 선속도 10m/hr 증가에 따라 약 0.1cm 정도의 손실수두 증가를 유발하는 것으로 나타났다. 또한, SS 제거효율은 81.4% 정도로 안정적이었고, 여과지속시간은 6시간 이상 유지되었으며, 공기역세척만으로도 98% 정도의 손실수두 평균 회복율을 보였다. 하수를 적용한 현장평가에서는 여재의 조기폐색을 방지하기 위한 전처리공정으로 벨트 형 미세스크린(450mesh 이상)를 적용했을 때 2시간 내외의 여과지속시간을 확보할 수 있었고, 평균 83.9%의 SS 제거효율을 나타내었다. CSOs 및 SSOs에 여과공정 적용을 위해서는 효율적 측면보다 여과지속시간의 안정적 유지를 위한 수리적 측면을 보완하기 위해서 전처리공정과의 조합이 중요하다는 결론을 얻을 수 있었다. 건기와 비교하여 우기의 유입하수 수질은 다소 낮은 보였으며, 이는 분류식 관거 비율이 높은 배수구역의 특성 때문인 것으로 추정된다. 또한, 우기와 건기의 유입수질에 따른 제거효율 차이는 미미하였다.