• Title/Summary/Keyword: Screen X

Search Result 323, Processing Time 0.023 seconds

Subjective Video Quality Evaluation and User Satisfaction according to Screen Size and Content Type : Comparison of UHD and UWV (화면크기와 콘텐츠유형에 따른 주관적 영상품질 평가와 이용자 만족도: UHD와 UWV 비교 분석)

  • Cho, EunSun;Lee, Jin-Myong;Rha, Jong-Youn;Park, Sunny;Koo, Hye-Gyoung;Cho, YongJu;Seo, Jung-Il
    • Journal of Digital Convergence
    • /
    • v.16 no.12
    • /
    • pp.283-292
    • /
    • 2018
  • UHD (Ultra High Definition) broadcasting technology, and UWV (Ultra Wide Vision) which is the high quality panoramic video of wide view angle based on UHD, were commercialized in Korea for the first time in the world, and those are representative realistic video technologies that maximize the user's sense of presence. By comparing the user's subjective reaction of UHD and UWV, the purpose of this study is to systematically establish the user's subjective video quality evaluation. For this purpose, a large screen projection experiment is designed by setting the screen size (4k x 2k, 8k x 2k) and content types (sports, landscape, concert) as variables to measure the user's subjective video quality evaluation and satisfaction. As a result of the study, the users' evaluation of UWV was higher than UHD in all items of subjective video quality, and satisfaction. Moreover, the results showed the significant differences depending on the video contents. Based on the results of the research, the study proposed the points necessary for the development and commercialization of UWV panoramic technology, and suggestions for the future research.

DNA testing for fragile X syndrome in school for severely emotionally handicapped children in Korea

  • Hong, Sung-Do David;Lee, So-Young;Oh, Myung-Ryurl;Jin, Dong-Kyu
    • Journal of Genetic Medicine
    • /
    • v.2 no.2
    • /
    • pp.83-86
    • /
    • 1998
  • Though Fragile X syndrome is one of the most common inherited causes of mental retardation, it is not much detected yet in Korean population. One of the reason may be that the syndrome is not well known to the special education teachers as well as to the clinicians in this country. Thus, molecular test was undertaken to screen out fragile X syndrome in 122 children of two Korean schools for emotionally severely handicapped children. The subjects were all boys, previously known as having pervasive developmental disorder with or without mental retardation. Southern blot analysis of peripheral blood showed the abnormally enlarged (CGG)n repeat sequence associated with fragile X syndrome in two children. This finding suggests that the DNA testing for fragile X syndrome is warranted for Korean high risk population and that more concern about this syndrome is needed for the professionals who work for mentally handicapped children. The issues involved in genetic counseling for fragile X syndrome are discussed.

  • PDF

The Study on Composition ratio of Iodine in Hybrid X-ray Sensor (혼합형 X선 센서에서 a-Se 의 Iodine 첨가비 연구)

  • Gong, Hyung-Gi;Park, Ji-Koon;Choi, Jang-Yong;Moon, Chi-Wung;Nam, Sang-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.366-369
    • /
    • 2002
  • At present, the study of direct digital X-ray detector and indirect digital X-ray detector proceed actively. But it needs high thickness and high voltage in selenium for high ionization rate. Therefore, we carried out the study of electric characteristics of a-Se with additive ratio of Iodine in drafting study for developing Hybrid X -ray Sensor for complementing direct digital X -ray detector and indirect digital X-ray detector in this paper. On this, there are formed Amorphous selenium multi-layers by sticking phosphor layer$(Gd_{2}O_{2}S(Eu^{2+}))$ using optical adhesives of EFIRON Co. Amorphous selenium multi-layers having dielectric layer(parylene) has characteristics of low dark-current, high X-ray sensitivity. So we can acquired a enhanced signal to noise ratio. We make Amorphous selenium multi-layers with $30{\mu}m$ thickness on glass.

  • PDF

Characterization Of YBCO HTSC-Thick film With addiction of $CeO_2$ ($CeO_2$첨가에 따른 YBCO고온초전도 후막의 특성)

  • 윤기웅;임성훈;홍세은;강형곤;한용희;한병성
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.239-242
    • /
    • 2000
  • To fabricate YBa$_2$Cu$_3$O$_{x}$ thick film using diffusion process, $Y_2$BaCuO$_{5}$ and BaO+CuO as the material of substrate and the doping material were selected. CeO$_2$ in the doping material was mixed. As another doping material, YBa$_2$Cu$_3$O$_{x}$ was prepared for the comparison with BaO+CuO doping material. Each doping material was patterned on $Y_2$BaCuO$_{5}$ substrate by the screen printing method and then was annealed above peritectic reaction temperature of YBCO with a few step. It could be observed by X-ray diffraction patterns and SEM photographs that through the diffusion process of the $Y_2$BaCuO$_{5}$ and BaO+CuO, the YBa$_2$Cu$_3$O$_{x}$ phase was formed. With an amout of addition of CeO$_2$, the thickness of a formed YBa$_2$Cu$_3$O$_{x}$ decreased. x/ decreased.

  • PDF

Fabrication of Mixed and Patterned Type of Remote Phosphors by Screen Printing Process and their Optical Properties

  • Kim, Byung-Ho;Hwang, Jonghee;Lee, Young Jin;Kim, Jin-Ho;Jeon, Dae-Woo;Lee, Mi Jai
    • Journal of the Korean Ceramic Society
    • /
    • v.53 no.4
    • /
    • pp.381-385
    • /
    • 2016
  • Recently, white LEDs, especially, warm white LEDs have been intensively investigated due to outstanding optical properties, long term stability and low power consumption. In this study, mixed type and patterned type of remote phosphors were prepared by screen printing process employing green and red phosphor. Each type of remote phosphor exhibited distinctive photoluminescence spectrum. For example, the mixed type of remote phosphor exhibited unique spectrum, while the patterned type showed expectable spectrum depending on the concentration of phosphors. This indicates that a small amount of red phosphor dramatically reduced the green photoluminescence in the case of mixed-type remote phosphor, whereas the effect was negligible in the patterned-type remote phosphor. The possibility of undesirable chemical reaction was further investigated by using scanning electron microscopy and X-ray diffraction.

Structural and dielectric properties of the BSCT thick films fabricated by the screen printing method (스크린 프린팅법으로 제작한 BSCT 후막의 구조적 특성과 유전적 특성)

  • Noh, Hyun-Ji;Lee, Sung-Gap;Lee, Chang-Gong;Nam, Sung-Pill;Lee, Young-Hie
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.167-167
    • /
    • 2008
  • The barium strontium calcium titanate powders were prepared by sol-gel method. Ferroelectric $(Ba_{0.54}Sr_{0.36}Ca_{0.1})TiO_3$(BSCT) thick films were fabricated by the screen-printing method on alumina substrate. And we investigated the structural and dielectric properties of BSCT thick films with the variation of sintering temperature. As a result of thermal analysis, BSCT polycrystalline perovskite phase was formed at around $660^{\circ}C$. The results of X-ray diffraction analysis were showed a cubic perovskite structure without presence of the second phase in all BSCT thick films. The average grain size and the thickness of the specimen sintered at $1450^{\circ}C$ were about 1.6 mm and 45 mm, respectively. The relative dielectric constant increased and the dielectric loss decreased with increasing the sintering temperature, the values of the BSCT thick films sintered at $1450^{\circ}C$ were 5641 and 0.4% at 1kHz, respectively.

  • PDF

Vacuum In-line Sealing Technology of the Screen-printed CNT-FEA

  • Kwon, Sang-Jik;Kim, Tae-Ho;Shon, Byeong-Kyoo;Cho, Euo-Sik;Lee, Jong-Duk;Uh, Hyung-Soo;Cho, Sung-Hee;Lee, Chun-Gyoo
    • Journal of Information Display
    • /
    • v.4 no.3
    • /
    • pp.6-11
    • /
    • 2003
  • We have fabricated a carbon nanotube field emission display (CNT-FED) panel with a 2-inch diagonal size by using a screen printing method and vacuum in-line sealing technology. The sealing temperature of the panel was around 390$^{\circ}C$ and the vacuum level was obtained with 1.4x$10^{-5}$torr at the sealing. When the field emission properties of a fabricated and sealed CNT-FED panel were characterized and compared with those of the unsealed panel which was located in a test chamber of vacuum level similar with the sealed panel. As a result, the sealed panel showed similar I-V characteristics with unsealed one and uniform light emission with very high brightness at a current density of 243 ${\mu}A/cm^2$, obtained at the electric field of 10 V/${\mu}m$.

Influence of PECVD SiNx Layer on Multicrystalline Silicon Solar Cell (PECVD SiNx 박막의 다결정 실리콘 태양전지에 미치는 영향)

  • Kim, Jeong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.18 no.7
    • /
    • pp.662-666
    • /
    • 2005
  • Silicon nitride $(SiN_x)$ film is a promising material for anti-reflection coating and passivation of multicrystalline silicon (me-Si) solar cells. In this work, a plasma-enhanced chemical vapor deposition (PECVD) system with batch-type reactor tube was used to prepare highly robust $SiN_x$ films for screen-printed mc-Si solar cells. The Gas flow ratio, $R=[SiH_4]/[NH_3]$, in a mixture of silane and ammonia was varied in the range of 0.0910.235 while maintaining the total flow rate of the process gases to 4,200 sccm. The refractive index of the $SiN_x$ film deposited with a gas flow ratio of 0.091 was measured to be 2.03 and increased to 2.37 as the gas flow ratio increased to 0.235. The highest efficiency of the cell was $14.99\%$ when the flow rate of $SiH_4$ was 350 sccm (R=0.091). Generally, we observed that the efficiency of the mc-Si solar cell decreased with increasing R. From the analysis of the reflectance and the quantum efficiency of the cell, the decrease in the efficiency was shown to originate mainly from an increase in the surface reflectance for a high flow rate of $SiH_4$ during the deposition of $SiN_x$ films.

EphrinB1 interacts with the transcriptional co-repressor Groucho/xTLE4

  • Kamata, Teddy;Bong, Yong-Sik;Mood, Kathleen;Park, Mae-Ja;Nishanian, Tagvor G.;Lee, Hyun-Shik
    • BMB Reports
    • /
    • v.44 no.3
    • /
    • pp.199-204
    • /
    • 2011
  • Ephrin signaling is involved in various morphogenetic events, such as axon guidance, hindbrain segmentation, and angiogenesis. We conducted a yeast two-hybrid screen using the intracellular domain (ICD) of EphrinB1 to gain biochemical insight into the function of the EphrinB1 ICD. We identified the transcriptional co-repressor xTLE1/Groucho as an EphrinB1 interacting protein. Whole-mount in situ hybridization of Xenopus embryos confirmed the co-localization of EphrinB1 and a Xenopus counterpart to TLE1, xTLE4, during various stages of development. The EphrinB1/xTLE4 interaction was confirmed by co-immunoprecipitation experiments. Further characterization of the interaction revealed that the carboxy-terminal PDZ binding motif of EphrinB1 and the SP domain of xTLE4 are required for binding. Additionally, phosphorylation of EphrinB1 by a constitutively activated fibroblast growth factor receptor resulted in loss of the interaction, suggesting that the interaction is modulated by tyrosine phosphorylation of the EphrinB1 ICD.

A Study on the Chest Radiography by Simultaneous Double Radiation Quality (동시(同時) 이선질(二線質)에 의한 Chest Radiography의 연구(硏究))

  • Hayashi, Tare;Ishida, Yuji;Shindo, Koichi;Maeda, Mika
    • Journal of radiological science and technology
    • /
    • v.12 no.1
    • /
    • pp.17-23
    • /
    • 1989
  • We have developed of the exposure technique for the chest radiography to get different contrast in left and right lung fields simultaneously for the effective diagnosis, I.E., get high contrast to detect tuberculosis, dispersal shadow or exudative lesions of early tuberculosis and get better sharpness and wider latitude to detect growing lesions of lung cancer or lesions overlapped with bones. As a result, by using an additional filter Cu 1.2mm with BX-III screen side and sheet of yellow cellophane on BF-III screen side at the conventional KV ($80KV{\sim}100KV$) for the chest X-ray, we can get similar densities in both left and right lung fields and, thus, this method is considered to be very effective for the quality diagnosis for the routine chest radiography.

  • PDF