• Title/Summary/Keyword: Screen X

Search Result 323, Processing Time 0.032 seconds

Development of Continuous Roll-to-Roll Screen Printing System Using a Flat Screen (평판 스크린을 이용하는 롤투롤 연속 스크린 인쇄 시스템의 개발)

  • Kim, Ga Eul;Jeon, Yong Ho;Lee, Moon Gu;Hong, Min Sung;Lee, Taik Min;Kwon, Sin
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.25 no.3
    • /
    • pp.217-223
    • /
    • 2016
  • In this research, a continuous roll-to-roll screen printing system was developed using a flat screen. It has a newly devised sliding mechanism of screen printing module, which can be controlled accurately in sync with a moving web, driven by a roll-to-roll tension control and web-guiding system. In addition, the real-time precision alignment module that consists of a vision camera and an $X-Y-{\theta}$ alignment stage was implemented. With this developed system, the feasibility of continuous printing with minimum pattern width below $60{\mu}m$ was verified, and an overlay of ${\pm}60{\mu}m$ between the laser-patterned reference mark and the printed mark on a 300-mm-wide film was achieved.

The Study on Characterization of Current-limiting with Diffusion Thickness of High-Tc Superconductor Thick Film (고온초전도후막의 확산두께에 따른 전류제한 특성연구)

  • Im, Seong-Hun;Gang, Hyeong-Gon;Han, Tae-Hui;Mo, Chang-Ho;Im, Seok-Jin;Han, Byeong-Seong
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.4
    • /
    • pp.210-218
    • /
    • 2000
  • For the fabrication of $YBa_2Cu_3O_x$ thick film, a substrate of $Y_2BaCuO_5$ was fabricated by adding $CeO_2$ into $Y_2BaCuO_5$ and two types of doping materials added with binder material were prepared. Each doping material was patterned on $Y_2BaCuO_5$substrate by the screen printing method and then was annealed at the temperature with a few step. It could be observed by X-ray diffraction patterns and SEM photographs that through the diffusion process of the $Y_2BaCuO_5$ and each doping material, the $YBa_2Cu_3O_x$ phase was formed. And with n additive of $CeO_2$ the thickness of formed $YBa_2Cu_3O_x$decreased. From the experiment of current limiting on thick film, the sample with thiner thickness of $YBa_2Cu_3O_x$ showed the more effective characteristics of current limiting.

  • PDF

Imaging Characteristics of Plastic Scintillating Fiber Screens for Digital Mammography

  • Choi, Won-Young;Walker, James K.;Jing, Zhenxue
    • Journal of Biomedical Engineering Research
    • /
    • v.17 no.2
    • /
    • pp.165-172
    • /
    • 1996
  • A scanning slot digital mammography system Luing a plastic scintillating fiber screen (SFS) is currently being developed To improve the x-ray interaction efficiency and absorption efficiency of an SFS, high Z elements can be added into the scintillating fiber core. In this paper, we investigated theoretically the zero spatial frequency detective quantum efficiency, DQE(0), and modulation transfer function, MTF(f), of three 2 cm thick SFSs made of polystyrene, polystyrene loaded with 5% by weight of lead, and polystyrene Loaded with 10% by weight of tin scintillating fibers. X-ray interaction efficiency, scintillating light intensity distributions and line spread functions were generated using Monte Carlo simulation. DQE(0) and MTF(f) were computed for x-ray energies ranging from 15 to 50 keV. Loading high Z elements into the SFS markedly increased the DQE(0). For x-ray energies used for mammovaphy, DQE(0) values of both high Z element loaded SFSs are about a factor of three higher than the DQE(0) of an Min-R screen. At mammographic x-ray energies, MTF(f) values of all three SFSs are Venter than 50% at 25 Ip/mm spatial frequency, and were found to be dominated by the 20 um individual scintillating fiber diameter used The results show that both hiP DQE(0) and spatial resolution can be achieved with the high Z element loaded SFSs, which make these SFSs attractive for use in a scanning slot detector for digital mammography.

  • PDF

Analysis of Eye Response to Low Brightness 3D Displays and Increase Brightness in 3D RPTV using Long Life, High Power DPR System

  • Li, Kenneth
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.763-764
    • /
    • 2008
  • 3D displays requires multiplexing of left and right pictures on the same screen so that they can be viewed independently by the view using various schemes, including LCD shutters, polarizers, narrow band filters, and lenticular lenses on the screen. All these methods reduce the effective screen brightness by as much as 10X. The eye responses to the lower brightness are analyzed and found to compensate partially giving a lower perceived brightness. This paper presents such eye response analysis and a low cost approach to increasing brightness in a RPTV using the long life DPR system, increasing the screen brightness by over 2.5 times, while maintaining acceptable lamp lifetime.

  • PDF

Effects of the Wire-screen Rib on Heat Transfer and Friction Factors (와이어 스크린 리브이 열전달과 마찰계수에 미치는 효과)

  • Oh, Se-Kyung;Ahn, Soo-Whan;Lee, Dae-Hee
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.2
    • /
    • pp.196-203
    • /
    • 2011
  • Experiments to determine heat transfer coefficients and friction factors are conducted on a stationary transverse parallel wire-screen rib roughened rectangular channel. The test section consists of 198 mm (W) x 40 mm (H) x 712 mm (L). The channel has the aspect ratio of 4.95 and hydraulic diameter of $D_h$=6.66 cm. Four wire screen ribs and a solid rib are used. 0.1 mm-thick-stainless steel foil heaters and thermocouples (T type) are used to measure the heat transfer coefficients. Reynolds numbers studied range from 20,000 to 60,000. The wire-screen rib height (e) to hydraulic diameter ($D_h$) ratio ($e/D_h$) is 0.075; spacing (p) to height ratio (p/e) is 10. Results indicate that the solid rib produces the greatest Nusselt number and friction factor.

Feasibility study of Hybrid X-ray detecter for Digital X-ray imaging application (디지털 방사선 적용을 위한 Hybrid 방사선 검출기의 Feasibility 연구)

  • Choi, Jang-Yong;Park, Ji-Koon;Lee, Chae-Hun;Lee, Kyu-Hong;Choi, Heung-Kook;Nam, Sang-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.04b
    • /
    • pp.77-80
    • /
    • 2004
  • In this study, the purpose is to verified the feasibility to develope Hybrid x-ray detector in order to resolve problems of direct and indirect x-ray detectors. The properties of X-ray detector depend on absorption of X-ray, charge generation by x-ray photon, leakage current. In this study, CdS was used as photoconductor, and $Y_2O_2S:Tb$ as x-ray phosphor was formed on CdS in order to embody Hybrid structure. And Screen printing was used to form Muli-layer. Characteristics of this specimen were analyzed by using SEM, and XRD. And Photoluminescence spectrum of $Y_2O_2S:Tb$, leakage current, with respect to applied voltages, output charge with respect to applied voltages, and X-ray sensitivity were measured. Also, linearity with respect to dose was measured. Leakage current was similar with direct digital x-ray detector, but sensitivity of the hybrid structure is much better than the single-layer structure.

  • PDF

The Formation of $YBa_2Cu_3O_{7-x}$(Y123) and CuO Phases in Cu-sheath YBCO Thick Films (동피복 YBCO 후막에서 $YBa_2Cu_3O_{7-x}$(Y123) 및 CuO상의 형성 기구)

  • Kim K.J.;Han S. C.;Han Y. H.;Jeong N. H.;Yun H. J.;Oh J. M.;Choi H. R.;Sung T. H.
    • Progress in Superconductivity
    • /
    • v.6 no.2
    • /
    • pp.129-132
    • /
    • 2005
  • The formation behavior of $YBa_2Cu_3O_{7-x}$(Y123) and CuO phases in the heat-treated Cu-sheathed YBCO thick films was studied. The thick films were prepared by screen-printing method using $BaCO_3$ and Y211 powders on Cu tapes. The screen-printed thick films were placed at the center of the tube furnace, heated to $930^{\circ}C$ in air atmosphere and then maintained at the temperature for 60 sec - 300 sec. The microstructure and phases formed in the thick films were investigated by using optical microscope, X-ray diffraction (XRD) and SEM image analysis. During the heat treatment, partial melting occurred rapidly in the printed layers by peritectic reaction between CuO and precursor powders, and then YBCO superconducting phases nucleated from the Cu tapes and grew in a form of thick films.

  • PDF

Comparison Study of the Modulation Transfer Function of a Prototype a-Se based Flat Panel Detector with Conventional Speed Class 400 Film/screen System (비정질 셀레늄을 이용한 직접방식의 디지털 방사선 검출기와 X-ray film과의 MTF측정을 통한 영상 질(quality) 비교평가에 관한 연구)

  • Park, Jang-Yong;Park, Ji-Koon;Kang, Sang-Sik;Moon, Chi-Woong;Lee, Hyung-Won;Nam, Sang-Hee
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.40 no.3
    • /
    • pp.163-171
    • /
    • 2003
  • To evaluate the performance of the digital radiography(DR) system developed in our group, the modulation transfer function(MTF) was measured and compared with that of an analog X- ray detector, film/screen system. The DR system has an amorphous selenium(a-Se) layer vacuum-evaporated on a TFT flat panel detector. The speed class 400 film/screen (Fuji) system has been being used in the clinical field as analog X-ray detectors. Both the square wave and slit method were used to evaluate their MTF. The square method was applied to both film/screen and the DR system. The slit method, however, was applied to only DR system. The full-width half maximum resolution of film/screen was 357${\mu}{\textrm}{m}$(1.4 lp/mm at 50% spatial frequency), and the resolution of DR was limited to 200${\mu}{\textrm}{m}$(2.5 lp/mm at 30%). These results indicate the measured resolution limitations approximate to the pixel pitch, 139 ${\mu}{\textrm}{m}$ of TFT. The MTF of DR is higher than that of film/screen by the factor of 1.785. It is proved that our a-Se based DR system has potential usefulness in the clinical field.

The Relationship of Overdensity to Overexposure Each Film/screen Systems in Chest Radiography (흉부 X선사진 농도로부터 표면선량을 산출하는 방법)

  • Kim, Jung-Min;Joon, Huo;Hayashi, Taro;Ishida, Yuji;Sakurai, Tatsuya
    • Journal of radiological science and technology
    • /
    • v.22 no.1
    • /
    • pp.13-20
    • /
    • 1999
  • This study is to calculate the exposed radiation dose using Bit method, NDD calculation method and monogram method without dosimeter. In addition, we can calculate the radiation dose from x-ray film density as a film badge. The authors examined the entrance skin dose from $2{\sim}3$ intercostal chest x-ray film density. We also studied the relationship between film density and equivalent dose in the each screen film system under the different radiation quality and the poor geometry condition of grid ratio. As results, we established the deductive method to define the entrance skindose from chest x-ray film density. The error range was found in the range $-13%{\sim}+l7%$ for between deductive entrance skindose and the $2{\sim}3$ intercostal chest x-ray film density to actual detective radiation dose with dosimeter.

  • PDF