• Title/Summary/Keyword: Screen X

Search Result 323, Processing Time 0.03 seconds

A Research on Development of Multi-Screen Image and Application to Ultra-High Definition Contents (멀티스크린의 발전과 초고화질 콘텐츠 응용에 대한 연구)

  • Moon, Dae-Hyuk
    • Journal of Industrial Convergence
    • /
    • v.18 no.6
    • /
    • pp.33-39
    • /
    • 2020
  • The multi-screen image system could make the audiences appreciate contents without special devices by expansively composing the images played on a single screen to many facets suitable for the use, which could provide the great immersiveness to the audiences. Based on the recent interest in realistic images, it is produced as films through the multi-projection technology such as Screen X or Escape, and it is developed into the media that could deliver stories and information. Also, the size of display tends to gradually get larger while the image quality is improved to high definition. Thus, the development is accelerated in the form of Digital Signage that could play the high definition image contents by solidly composing many HD or UHD display screens. Moreover, through the convergence of digital technologies, it is developed into the higher value-added industry that could have two-way communication. This study aims to understand the developmental history of multi-screen image from 1950 to the present, technical analysis, and the production method, and then to research how to minimize the image degradation when playing the contents, in various platforms using the multi-screen image.

Characterization studies of digital x-ray detector based on mercuric iodide (Mercuric iodide 기반의 디지털 X-선 검출기의 특성 연구)

  • Cho, Sung-Ho;Park, Ji-Koon;Choi, Jang-Yong;Suck, Dae-Woo;Cha, Byung-Yul;Nam, Sang-Hee;Lee, Byum-Jong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.392-395
    • /
    • 2003
  • For the purpose of digital x-ray imaging, many materials such as $PbI_2$, $HgI_2$, TlBr, CdTe and CdZnTe have been under development for servaral years as direct converter layer. $Hgl_2$ film detector have recently been shown as one of the most promising semiconductor materials to be used as direct converters in x-ray digital radiography. This paper, the $HgI_2$ films are deposited on conductive-coated glass by screen printing, in which $HgI_2$ powder is embedded in a binder and solvent, and the slurry is used to coat the conductive-coated glass. We investigated electrical characteristic of the fabricated $HgI_2$ films. The x-ray response to radiological x-ray generator of 70Kvp using the current integration mode will be reported for screen printing films. These results indicate that $HgI_2$ detectors have high potential as new digital x-ray imaging devices for radiography.

  • PDF

Surface Modification of a Screen-printed Carbon Electrode with Iridium Oxide and Its Application of an Impedance Sensor (스크린 프린팅 탄소 전극의 이리듐 산화물 표면 개질과 이의 임피던스 센서 응용)

  • Min Sik Kil;Jo Hee Yoon;Jinwu Jang;Bong Gill Choi
    • Applied Chemistry for Engineering
    • /
    • v.34 no.5
    • /
    • pp.493-500
    • /
    • 2023
  • In this study, we developed an impedance sensor capable of controlling electrode polarization by coating iridium oxide (IrOx) on the surface of the screen-printed carbon electrode. IrOx was deposited on the surface of carbon electrodes according to the number of cycles (0~50 cycles) by cyclic voltammetry. Observation of scanning electron microscope images revealed that the size and number of IrOx particles increased as the number of cycles increased. The changes in impedance responses as a function of the NaCl concentration of the as-obtained sensors were investigated using electrochemical impedance spectroscopy. The sensors manufactured in 50 cycles exhibited the best coefficient of determination and reproducibility, attributed to the well-controlled electrode polarization. We further demonstrated the usefulness of the IrOx-based sensor as a diagnosis sensor for dry eye syndrome by comparing the results of the commercially available osmometer and our sensor using actual solution samples.

Influence of Yb2O3 Doping Amount on Screen-printed Barium Strontium Calcium Titanate Thick Films

  • Noh, Hyun-Ji;Lee, Sung-Gap;Ahn, Byeong-Lib;Lee, Ju
    • Transactions on Electrical and Electronic Materials
    • /
    • v.8 no.6
    • /
    • pp.241-245
    • /
    • 2007
  • [ $(Ba_{0.9-x}Sr_xCa_{0.10})TiO_3$ ] (x=0.33, 0.36) powders were prepared by sol-gel method. $(Ba,Sr,Ca)TiO_3$(BSCT) thick films, undoped and doped with $MnCO_3$ and $Yb_2O_3(0.1{\sim}0.7mol%)$, were fabricated by the screen printing method on the alumina substrate. The coating and drying procedure was repeated 6-times. The Pt bottom electrode was screen printing method on the alumina substrate. These BSCT thick films were annealed at $1420^{\circ}C$ for 2 hr in atmosphere. The upper electrodes were fabricated by screen printing the Ag paste and then firing at $590^{\circ}C$ for 10 min. And then the structured and dielectric properties as a function of the doping amount of $Yb_2O_3$ were studied. As a result of the TG-DTA, exothermic peak was observed at around $670^{\circ}C$ due to the formation of the polycrystalline perovskite phase. All BSCT thick films showed XRD patterns of typical cubic peroveskite structure. The average thickness of BSCT thick films was about $70^{\mu}m$. The curie temperature and the dielectric constant decreased with increasing $Yb_2O_3$ doped content and the relative dielectric constant of the specimen, doped with 0.5 mol% $Yb_2O_3$ at BSCT(54/36/10), showed a best value of 5018 at curie temperature.

Quality Evaluation of Fresh ginseng by Soft X-ray and iodine Test. (연X선 및 요드반응에 의한 수삼의 품질평가)

  • Park, Hoon;Cho, Byung-Goo;Lee, Mee-Kyung
    • Journal of Ginseng Research
    • /
    • v.8 no.2
    • /
    • pp.167-171
    • /
    • 1984
  • Soft X-ray is useful to identify the quality of fresh ginseng causing the inside cavity or white pan of red ginseng. The portion of low mass density identified by the difference in absorption of soft X-ray showed lower dry matter density and less or no response to iodine test indicating less accumulation or excess consumption of starch. The inside white part of red ginseng absorbed less X-ray than the normal part did. Probability for identification of the inside cavity or white at fresh ginseng was rather high (80-90%) in screen observation than f'3m reading and seemed to be increased further by using the developed screen and with training. The inside white of red ginseng appeared to be due to starch deficiency. Dry matter density appeared to be better than fresh weight density for the quality criterion.

  • PDF

Precision Position Control for PCB Screen Printer Using Image Processing (화상처리를 이용한 PCB 스크린 인쇄기의 정밀위치제어)

  • 이근유;부이트롱휴;김동규;박순실;김상봉
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.295-295
    • /
    • 2000
  • In this paper, the measurement algorithm of PCB alignment error is developed using image processing. The X-Y-$\theta$ table correcting PCB alignment error is driven by drive module based on microprocessor according to calculation results obtained through image processing procedure. In order to recognize the X-Y-$\theta$ position errors, two fiducial points are marked on PCB and two cameras of ultraviolet rays types are used for detection of the points to capture exactly fiducial points under disturbance of illumination change. Through application for a practical screen printer, the precision control using the developed position control system can be realized about 2.5${\mu}{\textrm}{m}$ in table moving range and 8${\mu}{\textrm}{m}$ in camera processing precision.

  • PDF

Feasibility of Single-Shot Dual-Energy X-ray Imaging Technique for Printed-Circuit Board Inspection (인쇄회로기판 검사를 위한 단일조사 이중에너지 엑스선 영상기법의 유용성에 관한 연구)

  • Kim, Seung Ho;Kim, Dong Woon;Kim, Daecheon;Kim, Junwoo;Park, Ji Woong;Park, Eunpyeong;Kim, Jinwoo;Kim, Ho Kyung
    • Journal of Radiation Industry
    • /
    • v.9 no.3
    • /
    • pp.137-141
    • /
    • 2015
  • A single-shot dual-energy x-ray imaging technique has been developed using a sandwich detector by stacking two detectors, in which the front and rear detectors respectively produce relatively lower and higher x-ray energy images. Each detector layer is composed of a phosphor screen coupled with a photodiode array. The front detector layer employs a thinner phosphor screen, whereas the rear detector layer employs a thicker phosphor screen considering the quantum efficiency for x-ray photons with higher energies. We have applied the proposed method into the inspection of printed circuit boards, and obtained dual-energy images with background clutter suppressed. In addition, the single-shot dual-energy method provides sharper-edge images than the conventional radiography because of the unsharp masking effect resulting from the use of different thickness phosphors between the two detector layers. It is promising to use the single-shot dual-energy x-ray imaging for high-resolution nondestructive testing. For the reliable use of the developed method, however, more quantitative analysis is further required in comparisons with the conventional method for various types of printed circuit boards.

A comparative study for resolution and density of chest imaging using film/screen, CR and DR (X-ray 흉부영상 FIlm/Screen, CR, DR Resolution과 Density 비교평가)

  • An, Byeong-Ju
    • Journal of the Korean Society of Radiology
    • /
    • v.4 no.1
    • /
    • pp.25-30
    • /
    • 2010
  • The objective of this study was to compare the resolution and density appropriate to diagnosis in chest PA radiography. In comparing the resolution, we radiographed with conventional radiography, computed radiography(CR) and digital radiography(DR) using the linear resolution phantom(Nuclear Associates-Carle Place. N.Y.). 2 radiologists and 3 radiological technologists read the resolution value by the blind test. DR, conventional radiography and CR measured 3.95, 3.58, 3.48 resolution value respectively. In analysing the density, we chose the fifty normal chest CR and DR and conventional film. We estimated the density using by densitometer(X-rite company-Model 301) in seven regions(lung field, lung field margine, mediastinum I, mediastinum II, heart shadow I, heart shadow II, diaphragm) of chest film. We adapted to analysis the Japanese chest X-ray evaluating method and table. It was scored 0(farthest density value) to 2(nearest density value). DR scored 2 at mediastinum I, mediastinum II, heart shadow I, heart shadow II and diaphragm. On the contrary with, CR scored 2 at lung field and lung field margine. Consequently, DR superior than CR and conventional radiography film compairing density and resolution. It was due to small pixel size and post processing algorithm with digital radiography.