• Title/Summary/Keyword: Screen Design

Search Result 1,072, Processing Time 0.036 seconds

The Design and Evaluation of a Diagonally Splitted Column to Improve Text Readability on a Small Screen (소형 스크린 상에서의 텍스트 가독성 향상을 위한 대각분할 칼럼 디자인과 평가)

  • Kim Yeon-Ji;Lee Woo-Hun
    • Archives of design research
    • /
    • v.19 no.4 s.66
    • /
    • pp.51-60
    • /
    • 2006
  • Nowadays, reading text from screens is prevailing in everyday life. The advent of mobile information devices such as a cellular phone, PDA, and e-book reader facilitates us to enjoy various text-based contents any time and anywhere. Most studies comparing screen and paper readability show that screens are less readable than paper. Furthermore, the decrease of line length and number of lines that can be displayed on the screen of mobile information devices deteriorate text readability. This study investigated parameters affecting text readability on small screens and designed a new text layout to improve readability. We suggested a diagonally splitted layout of rectangular column, which is supposed to facilitate eye movement to trace text flow with ease. The experiment comparing readability between a traditional rectangular column and a diagonally splitted column was conducted. The result of experiment revealed that there is no significant difference between the two text layouts in terms of subjective satisfaction of reading task and a level of comprehension. However, in the screen size of $4000mm^2\;and\;8000mm^2$, reading speed was increased 18.9% and 34.0% respectively from a traditional rectangular column to a diagonally splitted column. We conducted a consecutive experiment to scrutinize the cause that improved the performance in readability task remarkably. The readability of text in a traditional rectangular column was compared with a left triangular column and a right triangular column in the condition of $4000mm^2/3:1$ ratio screen. The performance measurements revealed that participants read 21.1% and 67.6% faster respectively with the left triangular column and right triangular column than with the rectangular column. In consequence, the improvement of readability in the diagonally splitted column was attributed mainly to the increase of reading speed in the right triangular column. This research verified that the diagonally splitted column improve text readability on a small screen and this result is expected to make a contribution to designing an efficient text layout for mobile information devices

  • PDF

CRT competitive strategies towards flat panel displays

  • Sluyterman, A.A.S.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2003.07a
    • /
    • pp.137-141
    • /
    • 2003
  • CRTs can survive in the long run for TV applications, because of their realistic reproduction of live images. CRT technology development has to be directed towards form factor, but also attention has to be paid to the form design of sets. The CRT is the only technology allowing a doubly curved screen surface.

  • PDF

CRT Competitive Strategies Towards Flat Panel Displays

  • Sluyterman, A.A.S.
    • Journal of Information Display
    • /
    • v.4 no.1
    • /
    • pp.38-42
    • /
    • 2003
  • CRTs can survive in the long run for TV applications, because of their realistic reproduction of live images. CRT technology development has to be directed towards form factor, but also attention has to be paid to the form design of sets. The CRT is the only technology allowing a doubly curved screen surface.

Development of Virtual Reality Multi Screen Simulation System based on BIM (BIM 기반의 가상현실 다면투사 시뮬레이션 시스템 구축)

  • Seo, Myoung-Bae;Park, Hyung-Jin
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.30 no.3
    • /
    • pp.231-238
    • /
    • 2017
  • Using 3D based BIM(Building Information Modeling) enables a variety of construction simulations. The is no case to simulate BIM demonstration experiment on deeply immersed virtual reality environment in korea. This paper develops a multi screen based simulation system to enable 3D based immersed environment to diverse decision making and virtual construction simulation. In a developed simulation laboratory, we can carry out BIM drawing review, disaster evacuation simulation, constructability review on wild land and design urban planning using haptic device on 3-side space with 4K resolution . Also, It can review large amount of drawings without data conversion because of compatibility with BIM software.

Performance Indices of Needle Biopsy Procedures for the Assessment of Screen Detected Abnormalities in Services Accredited by BreastScreen Australia

  • Farshid, Gelareh;Sullivan, Thomas;Jones, Simeon;Roder, David
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.24
    • /
    • pp.10665-10673
    • /
    • 2015
  • Background: We wished to analyse patterns of use of needle biopsy procedures by BreastScreen Australia (BSA) accredited programs to identify areas for improvement. Design: BSA services provided anonymous data regarding percutaneous needle biopsy of screen detected lesions assessed between 2005-2009. Results: 12 services, from 5 of 7 Australian states and territories provided data for 18212 lesions biopsied. Preoperative diagnosis rates were 96.84% for lesion other than microcalcification (LOTM) and 93.21% for microcalcifications. At surgery 97.9% impalpable lesions were removed at the first procedure. Of 11548 Microcalcification (LOTM) biopsied, 46.9% were malignant. The final diagnosis was reached by conventional core biopsy (CCB) in 72.46%, FNAB in 21.33%, VACB in 1.69% and open biopsy in 4.52% of lesions. FNA is being limited to LOTM with benign imaging After FNAB, core biopsy was required for 38% of LOTM. In LOTM the mean false positive rate (FPR) was 0.36% for FNAB, 0.06% for NCB and 0% for VACB. Diagnostic accuracy was 72.75% for FNAB and 92.1% for core biopsies combined. Of 6441 microcalcifications biopsied 2305 (35.8%) were malignant. Microcalcifications are being assessed primarily by NCB but 6.57% underwent FNAB, 45.6% of which required NCB. False positive diagnoses were rare. FNR was 5% for NCB and 1.53% for VACB. Diagnostic accuracy was 73.52% for FNAB, 86.29% for NCB and 88.63% for VACB. Only 8 of 12 services had access to VACB facilities. Conclusions: BSA services are selecting lesions effectively for biopsy and are achieving high preoperative diagnosis rates. Gaps in the present accreditation standards require further consideration.

Influence of Service Characteristics on High Priority Performance Indicators and Standards in the BreastScreen Australia Program

  • Roder, David Murray;Ward, Gail Heather;Farshid, Gelareh;Gill, Peter Grantley
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.14
    • /
    • pp.5901-5908
    • /
    • 2014
  • Background: Data from BreastScreen Australia Screening and Assessment Services (SAS) for 2002-2010 were analysed to determine whether some SAS characteristics were more conducive that others to high screening performance, as indicated by high priority performance indicators and standards. Materials And Methods: Indicators investigated related to: numbers of benign open biopsies, screen-detected invasive cancers, and interval cancers, and wait times between screening and assessment. Multivariate Poisson regression was undertaken using as candidate predictors of performance, SAS size (screening volume), urban or rural location, year of screening, accreditation status, and percentages of clients from culturally and linguistically diverse backgrounds, rural and remote areas, and socio-economically disadvantaged areas. Results: Performance standards for benign biopsies and invasive cancer detection were uniformly met irrespective of SAS location and size. The interval cancer standard was also met, except in 2003 when the 95% confidence interval of the rate still incorporated the national standard. Performance indicators improved over time for: benign open biopsy for second or subsequent screening rounds; rates of invasive breast cancer detection for second or subsequent screening rounds; and rates of small cancer detection. No differences were found over time in interval cancer rates. Interval cancer rates did not differ between non-metropolitan and metropolitan SAS, although state-wide SAS had lower rates. The standard for wait time between screening and assessment (being assessed ${\leq}28$ days) was mostly unmet and this applied in particular to SAS with high percentages of culturally and linguistically diverse women in their screening populations. Conclusions: Gains in performance were observed, and all performance standards were met irrespective of SAS characteristics, except wait times to assessment. Additional descriptive data should be collected on SAS characteristics, and their associations with favourable screening performance, as these may be important when deciding on SAS design

Measurement of Aerodynamic Properties of Screens for Windbreak Fence using the Apparatus for Testing Screens (공력 저항 측정기를 이용한 방풍펜스 방진막의 공기 투과 저항력 측정)

  • Kim, Rack-Woo;Lee, In-Bok;Hong, Se-Woon;Hwang, Hyun-Seob;Son, Young-Hwan;Kim, Tae-Wan;Kim, Min-Young;Song, Inhong
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.55 no.6
    • /
    • pp.145-154
    • /
    • 2013
  • Recently, damage occurrence by wind erosion has been increasing in society. In times past, such problems only took place in desert area ; however, in recent years, the wind erosion problem is spreading out to agricultural land. Wind erosion in agricultural land can cause loss of loam soils, the disturbance of the photosynthesis of the crop fields and serious economic losses. To overcome the mentioned problems, installation of windbreak fence can be recommended which function as disturbing strong wind and wind erosion. However, there is still no proper guideline to install the windbreak fence and the installation used to rely on the intuition of the workers due to the lack of related studies. Therefore, this study measured the aerodynamic resistance of screens of the windbreak fence using the apparatus for testing screens. The apparatus for testing screens was designed to measure pressure loss around the screen. Measured pressure loss by wall friction compensated for pressure loss to calculate the aerodynamic resistance of screens. The result of pressure loss by regression analysis derived the aerodynamic coefficient of Darcy-Forchheimer equation and power law equation. The aerodynamic resistance was constant regardless of the overlapped shape when the screen was overlapped into several layers. Increasing the number of layers of the screen, internal resistance increased significantly more, and pressure loss caused by the screen also increased linearly when the wind speed was certain conditions, but permeability had no tendency. In the future, the results of this study will be applied to the computational fluid dynamics simulation. The simulation models will be also validated in advance by wind tunnel experiments. It will provide standard of a design for constructing windbreak fence.