• 제목/요약/키워드: Scout

검색결과 48건 처리시간 0.032초

Pharmacological Therapies of Obesity: A Review of Current Treatment Options

  • Bacher, H.Peter;Shepherd, Gillian M.;Legler, Udo F.
    • Biomolecules & Therapeutics
    • /
    • 제17권4호
    • /
    • pp.348-352
    • /
    • 2009
  • Over the last decade, the incidence of overweight and obesity has nearly doubled in many countries and is considered a pandemic. Obesity was identified as a major risk factor for cardiovascular disease as the same level as smoking and diabetes. Visceral fat is considered one of the key contributors to outcome and certain ethnic groups such as Asians seem to be more affected than others. Weight reduction through lifestyle changes was found to be impactful to improve overall health, but weight loss and maintenance thereof is limited and difficult to sustain. Surgical intervention demonstrated a greater weight loss in the severely obese and was associated with improved all-cause mortality. Despite numerous pharmacological targets and a high medical need, only few drugs have been successfully developed. Earlier studies with amphetamine-derived compounds showed significant weight loss but their critical safety profiles led to market withdrawals and disappointment. More recent compounds; orlistat - a lipase inhibitor, rimonabant - a cannaboid-1-receptor antagonist, and sibutramine - a combined serotonin/norepinephrine re-uptake inhibitor, all demonstrated similar significant efficacy; however, they carry specific safety profiles making them unsuitable for every patient. The main limitation of pharmacotherapy is the absence of clear benefit-risk assessments through outcome studies. Such a study - the SCOUT trial - was designed to compare sibutramine versus placebo and the effect on morbidity and mortality in nearly 10,000 obese patients with additional risk factors. Such studies could provide new scientific evidence for obesity treatment and may support future pharmacological approaches.

투과율과 설치각도에 대한 수제주변 세굴영역에 관한 실험 연구 (An Experimental Study on Scout Area around Groynes with Permeability and Install Angle)

  • 여홍구;강준구;김성중;노영신
    • 한국수자원학회논문집
    • /
    • 제39권7호
    • /
    • pp.583-592
    • /
    • 2006
  • 수제설치로 인해 발생되는 세굴공은 수중생물의 다양한 서식처 및 홍수 시 어류의 피난처 제공 등 환경 기능을 내포할 수 있다는 관점이 부각되고 있으며 이와 같은 요구를 충족하기 위해서는 기존의 안정성 문제에 대한 관점에서 벗어난 수제주변 세굴영역에 대한 연구가 필요하다. 생태서식처로의 세굴영역은 수제형태에 따라 다양한 형태가 생성될 수 있으므로 이에 대한 분석이 요구된다. 본 연구는 투과율과 설치각도를 변화한 실험을 통해 수제주변 세굴규모를 파악하여 환경적인 측면의 수제선정의 자료를 제안하는데 목적이 있다. 실험에 적용된 투과율은 불투과(0% 투과)와 투과수제(20%, 40%, 60%, 80%)이며 설치각은 $60^{\circ},\;90^{\circ},\;120^{\circ}$이다. 실험결과, 각 실험조건에 따른 최대세굴 발생시의 세굴영역과 세굴심을 분석할 수 있었으며 수제조건에 대한 차이를 제시하였다.

수침 및 감마선 처리가 밤의 저장특성에 미치는 영향 (Effects of Water Soaking and Gamma Irradiation on Storage Quality of Chestnuts)

  • 권중호;이정은;이새봄;정헌식;최종욱
    • 한국식품저장유통학회지
    • /
    • 제8권1호
    • /
    • pp.9-15
    • /
    • 2001
  • 밤(Castanea crenata, 은기)의 저장특성에 대하여 수침처리와 감마선 조사의 영향을 검토하기 위하여, 수확된 밤을 48시간 동안 수침 처리한 후 0, 0.15, 0.25 및 0.35 kGy의 감마선을 조사하고 $0^{\circ}C$와 95$\pm$2%의 상대습도에서 9개월 동안 저장하면서 품질변화를 측정하였다. 발아현상은 수침 처리된 밤에서만 저장말기에 나타났으며, 감마선을 0.35 kGy 조사한 밤에서는 발아되지 않았다. 수침처리 밤에서는 조사 선량에 무관하게 저장 초반기부터 부패가 발생되어 수침처리 되지 않은 경우보다 저장 9개월 후 약 2배의 부패율을 보였다. 중량감소는 수침 처리된 밤이 무처리 밤보다 적었으며, 조사선량의 영향은 없었다. 과육경도는 수침처리를 하지 않은 경우 감마선 조사에 의해 감소가 억제되었으며, 고선량 일수록 높게 유지되는 경향이었다. 전당함량은 감마선이 조사된 밤이 조사되지 않은 밤보다 저장말기에 높게 유지되었으며 선량에 따른 차이는 없었다. 비타민 C 함량은 감마선 조사 직후 다소 감소되었으나 저장 중 변화는 감마선 조사된 밤에서 완만하게 감소되었다. 가용성 탄닌의 함량은 발아억제 선량 범위의 감마선 조사에 영향을 받지 않았다.

  • PDF

비글견의 간 CT 혈관조영상에서의 Iopamidol과 Iopromide, Iohexol 조명제의 비교실험 (A Comparison of Iopamidol with Iopromide and Iohexol Contrast Media in Hepatic CT Angiography in Beagle Dogs)

  • 정유철;임창윤;김경민;이성옥;정주현;장진화;오선경;송경진;윤정희;최민철
    • 한국임상수의학회지
    • /
    • 제23권2호
    • /
    • pp.129-132
    • /
    • 2006
  • The purpose of this paper was to compare the clinical efficacy of iopamidol and iopromide, iohexol nonionic contrast media in terms of their image quality in Beagle dogs with hepatic CT angiography and their application in veterinary clinics. With 9 Beagle dogs, contrast media of iopamidol (pamiray-$300^(R)$) and iopromide (ultravist-$300^(R)$, iohexol (omnipaque-$300^(R)$) were induced intravenously (600 mg I/kg, BW) and CT angiography was done under general anesthesia. CT scan included scout, pre-contrast and cine examinations. During CT angiography, peak HU (Hounsfield unit) and peak time were examined on each site (ROI; region of interest) of the aorta, caudal vena cava, potral vein and liver parenchyma. Any side effects were also examined. After experiments, it was found that there were no significant changes of HU and maximal enhancing time of each ROIs of aorta, caudal vena cava, portal vein and liver parenchyma between these contrast media. And any side effects were not noted. So it is concluded that iopamidol has similiar contrast enhancement like as iopromide and iohexol in hepatic angiography and and it is thought to be useful for evaluation of the abdominal organs by CT scan in veterinary clinics.

인공치아 이식부위 분석을 위한 다기능 영상체계의 실험적 검사 (AN EXPERIMENTAL EXAMINATION OF MULTIMODAL IMAGING SYSTEM FOR IMPLANT SITE ASSESSMENT)

  • 박창서;김기덕
    • 치과방사선
    • /
    • 제28권1호
    • /
    • pp.7-16
    • /
    • 1998
  • The Scanora/sup (R)/ X-ray unit uses the principles of narrow beam radiography and spiral tomography. Starting with a panoramic overview as a scout image. multiple tomographic projections could be selected. This study evaluated the accuracy of spiral tomography in comparison to routine panoramic radiography for dental implant treatment planning. An experimental study was performed on a cadaver mandible to assess the accuracy of panoramic radiography and spiral tomography film images for measurement of metallic spheres. After radiographic images of the metallic spheres on the surgical stent were measured and corrected for a fixed magnification of radiographic images. following results were obtained. 1. In the optimal position of the mandible. the minimal horizontal and vertical distortion was evident in the panoramic radiography images. The mean horizontal and vertical magnification error in anterior sites was 5.25% and 0.75%. respectively. The mean horizontal and vertical magnification error in posterior sites was 0.50% and 1.50%. respectively. 2. In the displaced forward or in an eccentric position of the mandible. the magnification error of the panoramic radiography images increased significantly over the optimal position. Overall, the mean horizontal magnification error of the anterior site in the different positions changed dramatically within a range of -17.25% to 39.00%, compared to the posterior range of -5.25% to 8.50%. However, the mean vertical magnification error stayed with the range of 0.5% to 3.75% for all the mandibular positions. 3. The magnification effects in the tomographic scans were nearly identical for the anterior and posterior with a range of 2.00% to 5.75% in the horizontal and 4.50% to 5.50% in the vertical dimension, respectively. 4. A statistically significant difference between the anterior and posterior measurements was found in the horizontal measurements of the panoramic radiography images of the displaced forward and backward position of the mandible(P<0.05). Also a significant difference between the optimal panoramic and tomographic projections was found only in the vertical measurement(P<0.05).

  • PDF

Estimation of the effective dose of dental cone-beam computed tomography using personal computer-based Monte Carlo software

  • Kim, Eun-Kyung;Han, Won-Jeong;Choi, Jin-Woo;Battulga, Bulgan
    • Imaging Science in Dentistry
    • /
    • 제48권1호
    • /
    • pp.21-30
    • /
    • 2018
  • Purpose: To calculate the effective doses of cone-beam computed tomography (CBCT) using personal computer-based Monte Carlo (PCXMC) software (Radiation and Nuclear Safety Authority, Helsinki, Finland) and to compare the calculated effective doses with those measured using thermoluminescent dosimeters (TLDs) and an anthropomorphic phantom. Materials and Methods: An Alphard VEGA CBCT scanner (Asahi Roentgen Ind. Co., Kyoto, Japan) with multiple fields of view (FOVs) was used for this study. The effective doses of the scout and main projections of CBCT using 1 large and 2 medium FOVs with a height >10 cm were calculated using PCXMC and PCXMCRotation software and then were compared with the doses obtained using TLD-100 LiF and an anthropomorphic adult human male phantom. Furthermore, it was described how to determine the reference points on the Y- and Z-axes in PCXMC, the important dose-determining factors in this software. Results: The effective doses at CBCT for 1 large ($20.0cm{\times}17.9cm$) and 2 medium FOVs ($15.4cm{\times}15.4cm$ and $10.2cm{\times}10.2cm$) calculated by the PCXMC software were 181, 300, and $158{\mu}Sv$, respectively. These values were comparable (16%-18% smaller) to those obtained through TLD measurements in each mode. Conclusion: The use of PCXMC software could be an alternative to the TLD measurement method for effective dose estimation in CBCT with large and medium FOVs.

단백질 분해가 식물의 진균 병 진전에 미치는 영향 (The Roles of Protein Degradation During Fungal-plant Interactions)

  • 안일평;박상렬;배신철
    • 한국균학회지
    • /
    • 제38권2호
    • /
    • pp.89-94
    • /
    • 2010
  • 농업경영측면에서, 또 균학적생화학적 측면에서도 식물을 침해하는 진균들의 연구는 반드시 필요하며 병 발생이나 저항성 발현 기작 구명은 기주와 기생체에 대한 연구를 동시에 진행해야 정확히 파악할 수 있다. 현재 병원균이 생산하는 분비체상과 비병원성 인자에 대한 연구는 많은 경우 세균에서 수행되고 있으며 사상균 중 조균인 Phytophthora와 진균인 Cladosporium에서만 병원균의 effector 복합체와 기주의 저항성 기제 간 관계가 같이 진행되고 있을 뿐이다. 앞에서 살펴보았듯 진균-기주 체계에서 단백질 분해가 병원성 조절 및 침입에 관여한다고 정확히 알려진 것은 단지 수종에 불과하며 그 기작도 세포자가포식과 ubiquitin 부가반응에 제한되어 있다. Post translational modification과 단백질 분해기작이 대단히 다양하고 거의 모든 진핵생물 체계에서 관찰되고 있음을 고려할 때 단백질 분해 과정은 세균 뿐 아니라 진균에서도 병원성 발현과 저항성 조절에 참여하고 있을 것으로 생각되며 이에 대한 연구가 앞으로 계속 요구될 것이라 생각된다.

흉부 컴퓨터 단층 촬영에서 정규화를 사용한 다양한 히스토그램 평준화 기법을 비교 (Comparison of Based on Histogram Equalization Techniques by Using Normalization in Thoracic Computed Tomography)

  • 이영준;민정환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권5호
    • /
    • pp.473-480
    • /
    • 2021
  • This study was purpose to method that applies for improving the image quality in CT and X-ray scan, especially in the lung region. Also, we researched the parameters of the image before and after applying for Histogram Equalization (HE) such as mean, median values in the histogram. These techniques are mainly used for all type of medical images such as for Chest X-ray, Low-Dose Computed Tomography (CT). These are also used to intensify tiny anatomies like vessels, lung nodules, airways and pulmonary fissures. The proposed techniques consist of two main steps using the MATLAB software (R2021a). First, the technique should apply for the process of normalization for improving the basic image more correctly. In the next, the technique actively rearranges the intensity of the image contrast. Second, the Contrast Limited Adaptive Histogram Equalization (CLAHE) method was used for enhancing small details, textures and local contrast of the image. As a result, this paper shows the modern and improved techniques of HE and some advantages of the technique on the traditional HE. Therefore, this paper concludes that various techniques related to the HE can be helpful for many processes, especially image pre-processing for Machine Learning (ML), Deep Learning (DL).

미래전쟁을 대비한 NCW기반 전투력 발전방안 연구 (The Study on the improvement plan for Military combat power by base of NCW against the future War)

  • 허영대
    • 융합보안논문지
    • /
    • 제17권5호
    • /
    • pp.153-161
    • /
    • 2017
  • 미래의 전쟁은 정보우위와 전장의 가시화를 통한 신속한 지휘결심체계가 구축되어 있어야 전쟁의 승리를 보장 받을 수 있다. 전장감시, 지휘결심, 타격을 위한 전 과정이 네트워크를 통하여 모든 전투원이 정보를 실시간 공유하여, 지휘결심과 이를 수행하는 말단 전투원까지 일치감이 조성되어 전투를 수행하여야 승리를 보장 받을 수 있다. 즉 GPS, 무인정찰기에서 보내오는 영상정보, 첩보위성에서 보내는 정보를 실시간 수집하고 네트워크화 함으로서 정보우위를 달성할 수 있다. NCW는 미래 작전유형이 작전에 참여하는 모든 요소들의 네트워킹에 의해 유기적으로 연동되는 네트워크 중심 전장을 의미한다. 따라서 정보수집센서, 지휘 결심, 타격체계들이 지리적 여건에 제한되지 않고 네트워킹 되어 전투에 참여하는 지휘관에서부터 각개 병사에 이르기까지 원하는 시간에 원하는 정보를 획득할 수 있는 전쟁수행개념을 말한다. 미래의 전쟁은 확장된 전장공간으로 지상, 공중, 해상, 우주, 사이버 등 5차원 공간이 될 것이다. 네트워크 중심의 정밀 타격을 위하여 C4ISR+PGM과 Soft Kill 전자정보전이 요구될 것이다. NCW의 체계를 이해하고 이를 전투력향상에 적용하여 보고자 한다.

이차원 화학변위 기법을 이용한 간 및 심장 $^{31}P$ 자기공명분광에서의 Nuclear Overhauser 효과에 대한 연구 (The Effect of Nuclear Overhauser Enhancement in Liver and Heart $^{31}P$ NMR Spectra Localized by 2D Chemical Shift Technique)

  • 염헌규;이종민;김용선;이상권;서경진;배성진;장용민
    • Investigative Magnetic Resonance Imaging
    • /
    • 제8권2호
    • /
    • pp.94-99
    • /
    • 2004
  • 목적 : 인체의 심근 및 간조직의 생체내 $^{31}P$ MRS에서 NOE 효과에 의한 분광신호 세기의 증가를 평가하고자 하였으며 또한 동일 장기에서 대사물질에 따른 NOE 효과의 차이를 알아보고자 하였다. 대상 및 방법: 열명의 정상 성인군(남:여=8:2, 연령분포=24-32)을 대상으로 1.5T 자기공명영상/분광 장치에서 $^1H-^{31}P$ 이중 튜닝 표면 코일을 사용하여 생체내 $^{31}P$ MRS를 시행하였다. $^{31}P$ MRS 측정은 이차원 화학변위영상기법을 사용하였으며 동일한 파라미터에서 NOE 효과 없이 그리고 $^1H$ decoupling상태에서 NOE 효과에 의한 $^{31}P$ MRS 데이터를 획득하였다. $^{31}P$ MRS raw data의 postprocessing 후 얻어진 스펙트럼에서 주요 대사물질들의 신호증가를 비교하였다. 결과: 간조직의 $^{31}P$ HRS에서 NOE 효과에 의한 신호증가율은 $\alpha-ATP\;(7\%),\;\beta-ATP\;(9\%),\;\gamma-ATP\;(17\%),\;Pi\;(1\%),\;PDE\;(19\%),\;PME\;(31\%)$였다. 간조직의 경우 크리아틴 키나제가 없기 때문에 PCr 신호는 관찰되지 않았다. 심근의 $^{31}P$ MRS은 whole body 코일이 표면 코일보다 우수한 scout 영상을 제공하여 $^{31}P$ MRS의 localization에 유리하였다. $^{31}P$ 심근 다중 체적 스펙트럼에서 , 혈액의 DPG 신호는 심근으로부터 멀어질 수록 증가하는 양상을 나타내었고 NOE 효과에 의한 신호증가율은 $\alpha-ATP\;(12\%),\;\beta-ATP\;(19\%),\;\gamma-ATP\;(30\%),\;PCr\;(34\%),\;Pi\;(20\%),\;PDE\;(51\%),\;DPG\;(72\%)$ 였다. 결론: 간조직에 비해 심근의 경우 큰 신호증가를 보였고 이는 간조직 대사물질들의 $^{31}P$가 심근과는 다른 $^1H$ coupling을 나타냄을 의미한다고 해석할 수 있다.

  • PDF