THE CURRENT STATUS OF BIOMEDICAL ENGINEERING IN THE USA

  • Webster, John G.
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1992년도 춘계학술대회
    • /
    • pp.27-47
    • /
    • 1992
  • Engineers have developed new instruments that aid in diagnosis and therapy Ultrasonic imaging has provided a nondamaging method of imaging internal organs. A complex transducer emits ultrasonic waves at many angles and reconstructs a map of internal anatomy and also velocities of blood in vessels. Fast computed tomography permits reconstruction of the 3-dimensional anatomy and perfusion of the heart at 20-Hz rates. Positron emission tomography uses certain isotopes that produce positrons that react with electrons to simultaneously emit two gamma rays in opposite directions. It locates the region of origin by using a ring of discrete scintillation detectors, each in electronic coincidence with an opposing detector. In magnetic resonance imaging, the patient is placed in a very strong magnetic field. The precessing of the hydrogen atoms is perturbed by an interrogating field to yield two-dimensional images of soft tissue having exceptional clarity. As an alternative to radiology image processing, film archiving, and retrieval, picture archiving and communication systems (PACS) are being implemented. Images from computed radiography, magnetic resonance imaging (MRI), nuclear medicine, and ultrasound are digitized, transmitted, and stored in computers for retrieval at distributed work stations. In electrical impedance tomography, electrodes are placed around the thorax. 50-kHz current is injected between two electrodes and voltages are measured on all other electrodes. A computer processes the data to yield an image of the resistivity of a 2-dimensional slice of the thorax. During fetal monitoring, a corkscrew electrode is screwed into the fetal scalp to measure the fetal electrocardiogram. Correlations with uterine contractions yield information on the status of the fetus during delivery To measure cardiac output by thermodilution, cold saline is injected into the right atrium. A thermistor in the right pulmonary artery yields temperature measurements, from which we can calculate cardiac output. In impedance cardiography, we measure the changes in electrical impedance as the heart ejects blood into the arteries. Motion artifacts are large, so signal averaging is useful during monitoring. An intraarterial blood gas monitoring system permits monitoring in real time. Light is sent down optical fibers inserted into the radial artery, where it is absorbed by dyes, which reemit the light at a different wavelength. The emitted light travels up optical fibers where an external instrument determines O2, CO2, and pH. Therapeutic devices include the electrosurgical unit. A high-frequency electric arc is drawn between the knife and the tissue. The arc cuts and the heat coagulates, thus preventing blood loss. Hyperthermia has demonstrated antitumor effects in patients in whom all conventional modes of therapy have failed. Methods of raising tumor temperature include focused ultrasound, radio-frequency power through needles, or microwaves. When the heart stops pumping, we use the defibrillator to restore normal pumping. A brief, high-current pulse through the heart synchronizes all cardiac fibers to restore normal rhythm. When the cardiac rhythm is too slow, we implant the cardiac pacemaker. An electrode within the heart stimulates the cardiac muscle to contract at the normal rate. When the cardiac valves are narrowed or leak, we implant an artificial valve. Silicone rubber and Teflon are used for biocompatibility. Artificial hearts powered by pneumatic hoses have been implanted in humans. However, the quality of life gradually degrades, and death ensues. When kidney stones develop, lithotripsy is used. A spark creates a pressure wave, which is focused on the stone and fragments it. The pieces pass out normally. When kidneys fail, the blood is cleansed during hemodialysis. Urea passes through a porous membrane to a dialysate bath to lower its concentration in the blood. The blind are able to read by scanning the Optacon with their fingertips. A camera scans letters and converts them to an array of vibrating pins. The deaf are able to hear using a cochlear implant. A microphone detects sound and divides it into frequency bands. 22 electrodes within the cochlea stimulate the acoustic the acoustic nerve to provide sound patterns. For those who have lost muscle function in the limbs, researchers are implanting electrodes to stimulate the muscle. Sensors in the legs and arms feed back signals to a computer that coordinates the stimulators to provide limb motion. For those with high spinal cord injury, a puff and sip switch can control a computer and permit the disabled person operate the computer and communicate with the outside world.

  • PDF

三重水素($^{3}H$) 放射能의 生理分析에 關한 硏究 (A Study on Bioassay of Tritium($^{3}H$) Radioacitivity)

  • 황선태;오필재;김원식
    • 한국대기환경학회지
    • /
    • 제3권1호
    • /
    • pp.27-33
    • /
    • 1987
  • 삼중수소 ($^{3}H$) 에 관한 환경 및 생물학상의 연구는 1950년대 중반부터 선진국에서 수행되오고 있다. 삼중소소에 대한 잠재적 노출의 경우 통상적 처리절차는 삼중수소의 신체부하량이라고 일컬어지는 이른바 신체내에 축적된 삼중수소의 양을 결정하기 위하여 삼중수소수로서 오줌속에 포함되는 삼중수소 방사능의 생리분석이다. 전신에 있어서 삼중수소의 최대허용신체부하량은 신체조직에 대하여 약 $30{\mu}Ci/{\ell}$ 이다. 생리분석에서 오줌속에 삼중수소를 검출하는데 가장 보편적인 조사준위(照射准尉)는 최대허용신체부하량의 1/10 이다. 이러한 생리분석 연구계획을 위해서는 소광보정(消光補正) 곡선을 그리는 것이 가장 우선적이다. 이것은 검뇨용 오줌의 색깔이 일정하지 않기 때문에 필요한 것이다. 이 경우에서 소광효과는 주로 오줌시료에 의한 섬광빛의 흡수에 기인된다. 소광보정곡선으로 판단된 공식은 통계적 근거에서 최소자승법에 의하여 Y (%) = 0.771 + 1.836 ${\tmes}10^{-4}$X(count)로 얻어졌다. 여기서 Y는 섬광계수 효율로서 약 12%에서 31% 범위의 값으로 나타났다. 본 논문에서는 삼중수소의 생물학적 반감기와 신체계통적으로 분포된 삼중수소에 적용되고 있는 정체(停滯) 공식에 관한 간략한 이론에 관하여 서술된다.

  • PDF

형광체 스크린 기반 평판형 X선 검출기 적용을 위한 요오드화수은 필름 광도전체 센서 설계 및 제작 (Design and Fabrication of HgI2 Sensor for Phosphor Screen based flat panel X-ray Detector)

  • 박지군;정봉재;최일홍;노시철
    • 전자공학회논문지
    • /
    • 제51권12호
    • /
    • pp.189-194
    • /
    • 2014
  • 본 연구에서는 새로운 구조의 X선 영상 검출기로써 광민감 $HgI_2$ 층이 포함된 CsI:Na 형광층의 구조를 설계하였다. 이러한 구조에서 X선은 두꺼운 CsI:Na 층에서 가시광선으로 변환된 후 하부의 얇은 $HgI_2$ 층에서 전하로 변환된다. CsI:Na와 $HgI_2$로 구성된 복합구조의 두께를 최적화하기 각 층의 두께를 변화시켜 X선에 대한 흡수효율을 시뮬레이션 하였다. 현재 상용화된 a-Se 단일층의 검출기는 수십 kV의 고전압이 요구되고, CsI:Na/a-Si 구조의 간접변환 방식은 낮은 변환효율을 가지는 단점이 있다. 본 연구의 결과로 제시된 새로운 형태의 CsI:Na/$HgI_2$ 복층 구조의 x-ray 검출기는 고전압이 필요한 직접 변환방식의 단점과 간접 변환방식의 낮은 효율을 보완할 수 있을 것으로 생각된다.

PET/CT 장치의 uniformitly측정에 관한 연구 (A Study of Uniformity Test in PET/CT)

  • 김수근;정희일;박성옥
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제29권1호
    • /
    • pp.13-19
    • /
    • 2006
  • PET scanner는 양전자의 소멸복사에 의한 511 Kev의 감마선을 검출한다. multi ring detector에서 선원과 검출기사이의 기하학적 위치에 따른 감마선 검출에 대한 균등성(uniformity)을 검토 분석하였다. 감마선원과 검출기의 배열위치에 따른 이론적 검토와 일정한 크기의 phantom 내에서 방출되는 감마선을 2차원적으로 preset count하고, 검출기의 위치에 따라 평균계수치에 대한 편차율의 분포를 통하여 그 균등성을 비교 분석하였다. 1 bed data를 얻을 수 있는 47개의 검출기군으로 분류하고, 각 검출기군의 위치에 따른 편차율을 비교분석한 결과, 산란선과 산란되지 않은 모든 방사선량의 분포가 많은 중심군인 3번째부터 45번째까지에서는 평균편차의 비율이 $0.1{\sim}0.7%$로 비교적 균등도가 높게 나타났으나, 주변부에서는 편차율의 분포가 $1.1{\sim}5.2%$의 차이를 나타내고 있어, 주변부에서의 균등성이 중심부보다 감소되었다. 이것은 검출기 위치에 따른 계수율의 차이에 대한 이론적 근거와 일치하고 있으며, 감도를 알기위한 계수측정 부분에서도 중심부와 주변부와의 차이가 크게 다르게 나타났다. 이와같은 불균등성을 감소시키기 위하여 선원으로부터 모든 검출기 유효시야(UFOV) 내에서 충분한 방사능이 검출될 수 있도록 하는 우선적 조치가 필요하다고 판단된다.

  • PDF

SiPM을 사용한 두 층의 반응 깊이를 측정하는 양전자방출단층촬영기기의 검출기 모듈 설계 (Design of Two Layer Depth-encoding Detector Module with SiPM for PET)

  • 이승재
    • 한국방사선학회논문지
    • /
    • 제13권3호
    • /
    • pp.319-324
    • /
    • 2019
  • 실리콘광전증배관(Silicon Photomultiplier, SiPM)과 두 층의 섬광 픽셀 배열을 이용한 반응 깊이 측정 검출기를 설계하였으며, 위치 측정 능력을 DETECT2000을 사용하여 검증하였다. 섬광 픽셀의 면 처리와 반사체 조합을 통해 섬광 픽셀과 감마선이 반응한 위치를 추적하였다. 아래층은 광학적으로 연결된 부분을 제외하고 반사체로 처리하였으며, 위층은 가장 외곽부분을 제외하고 모두 광학적으로 연결되도록 처리하여 빛의 공유가 아래층에 비해 자유롭도록 구성하였다. 거울반사체와 난반사체, 섬광 픽셀의 거친 면과 매끈한 면의 조합을 통해 평면 영상을 획득하였으며, 층별 영상이 생성되는 위치를 측정하여 분석하였다. 앵거 알고리듬을 사용하여 SiPM의 16채널 신호를 4개의 채널로 감소시켜 영상을 재구성하였다. 섬광 픽셀의 거친면과 모든 반사체 조합에서 두 층으로 구분되는 것을 확인할 수 있었으며, 매끈한 면일 경우에는 모두 층 구분이 불가능한 것을 확인할 수 있었다. 따라서 거친 면의 섬광 픽셀과 반사체 조합을 사용한 검출기를 사용할 경우 전임상용 PET에서 반응 깊이 측정을 통해 검출 시야 외곽에서의 공간분해능을 향상시킬 수 있을 것이다.