• Title/Summary/Keyword: School buildings

Search Result 1,681, Processing Time 0.026 seconds

A Study on the Current State of Seismic-Resistance and the Feature of Seismic Performance in School Buildings (학교건축물의 내진현황과 내진성능 특성에 관한 연구)

  • Jo, Min-Joo;Lee, Ju-Na
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.19 no.3
    • /
    • pp.33-40
    • /
    • 2012
  • At present, the problem to secure seismic resistance capacity is one of the most important issue in school buildings. However, the range of facilities to consider retrofit or the proper direction of seismic retrofit haven't provided in details. Therefore in this study, a series of school buildings were chosen as established time, and the structure composition and the seismic performance of the school buildings were investigated to get the comprehensive features of seismic resistance capacity in school buildings. At result, it was presented that the member capacities were less than criteria and structure system was showed the brittle behavior at the collapse prevention level at the school buildings before 1990 year. At the school buildings after 1990 year, though it is hard to get general features for various compositions, it was presented that they have problems for seismic performance evaluation in some buildings at life safety level, specially in the direction of X axis. So, considering the introduction process of seismic criteria in Korea, the school buildings before 2005 year should be examined for seismic resistance capacity and the seismic performance should be examined as well as member capacity to resist seismic.

Seismic performance evaluation of school buildings in Turkey

  • Inel, Mehmet;Ozmen, Hayri Baytan;Bilgin, Huseyin
    • Structural Engineering and Mechanics
    • /
    • v.30 no.5
    • /
    • pp.535-558
    • /
    • 2008
  • This study evaluates seismic performance of the school buildings with the selected template designs in Turkey considering nonlinear behavior of reinforced concrete components. Six school buildings with template designs were selected to represent major percentage of school buildings in medium-size cities located in high seismic region of Turkey. Selection of template designed buildings and material properties were based on field investigation on government owned school buildings in several cities in western part of Turkey. Capacity curves of investigated buildings were determined by pushover analyses conducted in two principal directions. The inelastic dynamic characteristics were represented by equivalent single-degree-of-freedom (SDOF) systems and their seismic displacement demands were calculated under selected ground motions. Seismic performance evaluation was carried out in accordance with recently published Turkish Earthquake Code that has similarities with FEMA-356 guidelines. Reasons of building damages in past earthquakes are examined using the results of performance assessment of investigated buildings. The effects of material quality on seismic performance of school buildings were investigated. The detailed examination of capacity curves and performance evaluation identified deficiencies and possible solutions for template designs.

A Survey on the Block Type of Elementary School Buildings - Focused on Chungbuk Province in Korea - (초등학교(初等學校) 교사동(校舍棟) 유형(類型)에 관한 조사연구(調査硏究) - 충북지역(忠北地域) 공립학교(公立學校)를 중심(中心)으로 -)

  • Hong, Jai-Bum;Kim, Tai-Young
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.8 no.1
    • /
    • pp.5-14
    • /
    • 2001
  • The purpose of this study is to clarify the block type of school buildings based on present conditions, by picking up elementary school buildings of Chungbuk Province in Korea. The summary of the block types can be given below. 1) Elementary school buildings(495) in Chungbuk Province are almost built in an average block of 1.7school(290). 2) The block types of school buildings are classified with "-", "ㄱ", "ㄷ", and parallel type. There are many "-" types over and parallel types in the second place of them. 3) The "-" block types are uniformly distributed with 166 elementary schools, below 6 classroom, 7through 24classrooms, beyond 25 classrooms. The "ㄱ" block types are 8 schools, and built as the wing of "-" block type in a limited space. The parallel types are classified with 2 3 lines according to the numbers of paralleled school buildings. The 2 parallel types are firstly represented with more than 95 classrooms, and 5 schools of "ㄷ" types, built as the wing of 2 parallel types, are only represented over 25 classrooms. The 3 parallel types are only 16 schools of all. They are uniformly seen in old and new school buildings.

  • PDF

A Study on Sensitivity to Temperature of Electricity Consumption in School Buildings (학교 건축물 전력소비의 기온감응도에 관한 연구)

  • Kim, Tae-Woo;Lee, Kang-Guk;Kim, Ho-Soon;Hong, Won-Hwa
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.18 no.5
    • /
    • pp.13-21
    • /
    • 2011
  • In case of school buildings, energy consumption has been noticeably on the increase, along with the changes in outdoor temperature triggered by the improvement in national economic development and educational environments. Research on the characteristics of energy consumption in school buildings influenced by the changes in outdoor temperature is considered very significant in social aspects in that it will be fundamental to the suggestion of the alternatives, such as saving energy consumption in construction buildings and control of emitting carbon dioxide. In this regard, this study examined sensitivity to temperature of power consumption in school buildings, based on the changes of outdoor temperature for the past five years in the target buildings of elementary, middle and high schools and the amount of energy consumption. From the results, it has been believed that this study was very significant in terms of figuring out a quantitative, optimum level of energy consumption, maintenance of pleasant environments and functions, and the necessity of effective energy use and management in school buildings.

  • PDF

A Study on Planning Ecological School Buildings by Traditional Construction Techniques -Focused of the buildings of traditional education institutions- (전통 건축기법을 이용한 친환경학교건축 계획방향에 관한 연구 -전통 교육건축을 중심으로-)

  • Kim, Yeon-Hyouk
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.7 no.1
    • /
    • pp.29-38
    • /
    • 2008
  • The purpose of this study was to discuss how traditional construction practices could be applied to school buildings. The spatial arrangement and constituents of Seoweon and Hyanggyo buildings were analyzed, and the spatial arrangement and ground plans of current schools were analyzed as well. As a result, it's found that how the characteristics of traditional architecture should be reflected in today's school design is one of critical matters that need an immediate attention. Based on the case study, there are some suggestions about the application of traditional construction techniques to school buildings: (1) The link between internal and external spaces should be stressed. The type of spatial configuration the could ensure nature accessibility is required. (2) The use of environment-friendly materials is recommended, and classrooms should be arranged in a way to let them function as multipurpose educational spaces. (3) It's not advisable to construct school buildings according to the sung-Confucianistic construction techniques of traditional educational institutions, but there should evidently be a change in tasteless school buildings, They should be built in small size and in consideration of harmony with nature and ecosystem, and boarding schools should be constructed in a more careful and discreet manner.

  • PDF

Development of Economic Analysis Model for Rebuilding Feasibility Evaluation of Old School Building (노후 학교건물의 개축 타당성 평가를 위한 경제성 분석 모델 개발)

  • Lee, Changsu;Ahn, Heejae;Kwon, Woobin;Kim, Minju;Kim, Harim;Cho, Hunhee
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.05a
    • /
    • pp.273-274
    • /
    • 2023
  • Although there are many old school buildings that is more than 40 years in Korea, it is difficult to rebuild all of them due to limitations in budget management. Therefore, objective feasibility evaluation criteria are necessary to determine which school buildings should be rebuilt preferentially among the numerous old school buildings. One of the rebuilding feasibility evaluation items, economic evaluation generally requires documents such as construction statements and facility drawings. However, because most buildings older than 40 years do not have these documents, an economic analysis model that requires only basic building information should be developed. In this study, the economic analysis model that can be used for evaluating the rebuilding feasibility only with the number of years, total floor area, and structural information of school buildings was established. This model can contribute to the objective feasibility evaluation of old school buildings because it can evaluate numerous buildings on the same criteria based on basic building information.

  • PDF

Determining the Priority of Factors for Reducing Energy at Deteriorated School Buildings Using AHP Method (AHP 방법을 이용한 노후학교 에너지절감을 위한 요소기술의 우선순위 결정)

  • Lhee, Sang-Choon;Choi, Young-Joon;Choi, Yool
    • KIEAE Journal
    • /
    • v.11 no.6
    • /
    • pp.127-132
    • /
    • 2011
  • Since the late 20th century, countries of the world have made every effort to solve environmental problems due to global warming. The Korean Government has also made various efforts on reducing energy and $CO_2$ emission under the motto of "Low-Carbon Green Growth". In order to achieve the goal to reduce energy in the construction field, severe design standards and regulations on saving energy in new buildings have been established. However, for maximizing the reduction of energy in buildings, it is time to focus on deteriorated buildings where applications of energy saving designs and techniques have been insufficient. Especially, there are little guidelines and researches on reducing energy through remodeling at deteriorated school buildings which were built over 20 years ago. This paper suggests the priority of factors to reduce energy on the remodeling process at deteriorated school buildings using the AHP(Analytic Hierarchy Process) method. For applying the AHP method, the survey of staffs in the Education Offices and board members in the Korea Institute of Ecological Architecture and Environment was conducted via e-mail. As a result, factors of insulation, daylighting, system control, and windows turned out important in the energy reducing remodeling process at deteriorated school buildings, while factors of artificial lighting, solar heating, ventilation, and system did relatively unimportant.

A Study on the Functional Mixed-use between School Buildings and Community Facilities (학교시설과 지역시설과의 복합화 방안에 관한 연구)

  • Kim, Seung-Je
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.16 no.1
    • /
    • pp.51-58
    • /
    • 2009
  • The purpose of this study is to have a guideline for mixed-use between school buildings and the community facilities as one of the suggestions to satisfy the needs of the society and to overcome the limitations of the supply of regional facilities. Main contents of this study are as a follow : 1) Arrangement of concept for mixed-use facilities, 2) Classification of community facilities for school buildings. 3) Distribution of school buildings in Nowon-Gu 4) Distribution of community facilities in Nowon-Gu 5) A proposal of mixed-use guide line between school buildings and public office.

A Study on the Improvement of Energy Performance in School Buildings (학교건물의 에너지 성능개선에 관한 연구)

  • 박진철
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.1
    • /
    • pp.54-61
    • /
    • 2004
  • The purpose of this study is to improve of energy performance in school buildings. Many building renovations have mainly focused on commercial buildings and houses, but school buildings have no attention in this field although there are many buildings that show degraded energy performance and there are many old fashioned buildings which need renovation. This study was carried out through the survey, field study, energy simulation and life cycle cost analysis. The results of this study can be summarized as follows: In model building, large amount of heat were lost at the building envelope, such as non-insulated skins, window-sills and window-frame joints. According to the simulation result, about 15% of heating energy is saved by the insulating works compared to pre-renovation condition. Also, LCC analysis revealed to be more effective to select a exteria wall insulation such as a dryvit system.

Comparing Performances of Factors for Reducing Energy at Deteriorated Elementary School Buildings (노후 초등학교 건물에너지 절감을 위한 요소기술의 성능 비교)

  • Lhee, Sang-Choon;Choi, Young-Joon;Kim, Hyun-Ki;Choi, Yool
    • KIEAE Journal
    • /
    • v.12 no.2
    • /
    • pp.111-116
    • /
    • 2012
  • Faced with the international issue of environmental problems from global warming and energy consumption, the Korean Government has made many efforts on reducing energy and $CO_2$ emission under the motto of "Low-Carbon Green Growth". In order to reduce energy in the building sector, severe design standards and regulations on saving energy in new buildings have been established. Now, it is necessary to focus on deteriorated buildings where applications of energy saving designs and techniques have been insufficient, for maximizing energy saving in the building sector. Specially, it is very important to reduce energy through the remodeling process at deteriorated school buildings which were built over 20 years ago and sharply changed into the excessive energy consumption structure from new educational curricula. Thus, this paper examined the effects of potential factors to reduce energy at deteriorated elementary school buildings using the energy simulation on the Visual DOE 4.0 program. Among applied factors of insulations, southern louver, window's SHGC, indoor setup temperature, and system efficiency, all factors except window's SHGC turned out contribute to reduce energy at the deteriorated elementary school buildings, compared with the baseline energy performance.