• 제목/요약/키워드: School Dust

검색결과 539건 처리시간 0.03초

High Resistivity Characteristics of the Sinter Dust Generated from the Steel Plant

  • Lee, Jae-Keun;Hyun, Ok-Chun;Lee, Jung-Eun;Park, Sang-Deok
    • Journal of Mechanical Science and Technology
    • /
    • 제15권5호
    • /
    • pp.630-638
    • /
    • 2001
  • The electrical resistivity of sinter dusts generated from the steel industry and coal fly ash from the coal power plant has been investigated using the high voltage conductivity cell based on JIS B 9915 as a function of temperature and water content. Dust characterization such as the chemical composition, size distribution, atomic concentration, and surface structure has been conducted. Major constituents of sinter dusts were Fe$_2$O$_3$(40∼74.5%), CaO (6.4∼8.2%), SiO$_2$(4.1∼6.0%), and unburned carbon (7.0∼14.7%), while the coal fly ash consisted of mainly SiO$_2$(51.4%), Al$_2$O$_3$(24.1%), and Fe$_2$O$_3$(10.5%). Size distributions of the sinter dusts were bi-modal in shape and the mass median diameters (MMD) were in the range of 24.7∼137㎛, whereas the coal fly ash also displayed bi-modal distribution and the MMD of the coal fly ash was 35.71㎛. Factors affecting resistivity of dusts were chemical composition, moisture content, particle size, gas temperature, and surface structure of dust. The resistivity of sinter dusts was so high as 10(sup)15 ohm$.$cm at 150$\^{C}$ that sinter dust would not precipitate well. The resistivity of the coal fly ash was measured 1012 ohm$.$cm at about 150$\^{C}$. Increased water contents of the ambient air lowered the dust resistivity because current conduction was more activated for absorption of water vapor on the surface layer of the dust.

  • PDF

황사발생지역에서 토양입자의 화학적 특성 (Soil Chemical Properties in Asian Dust Source region in Northern China)

  • 한진석;신선아;공부주;박문수;박순웅;김수진
    • 환경영향평가
    • /
    • 제13권6호
    • /
    • pp.277-284
    • /
    • 2004
  • The chemical composition and properties of soil were determined at selected sites, such as Loess plateau, Gobi and sand deserts in northern China, where most dust storms occur. Although the transport of this sort of dust storms to Korean peninsula is a well-documented phenomenon, there is not enough information about the very source regions. In this reason, this study tried to measure the chemical composition, including soil elements, anthropogenic elements and ions for soil samples so that certain properties of some major source regions of Asian Dust can be provided. Furthermore, the results are classified into four types of soil like Loess, Loess & sand, Gobi, and sand in order to identify the characteristics and difference among the types. $(X/Al)_{crust}$ values for each soil type were also calculated in this study and compared with those of other references including Asian Dust material(ADM). The results indicated that Ca contribution was higher than Al in all the soil types of this study including ADM and, compared with the values of urban area, contribution of anthropogenic elements such as Cr, Pb, Zn was quite low. However, it must be noted that there is such a variation in the result of soil composition, but it is also certain that the very source region soil composition resolved from this study could support the enhanced study on Asian Dust phenomenon in Korea.

An investigation of seasonal variations in the microbiota of milk, feces, bedding, and airborne dust

  • Nguyen, Thuong Thi;Wu, Haoming;Nishino, Naoki
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제33권11호
    • /
    • pp.1858-1865
    • /
    • 2020
  • Objective: The microbiota of dairy cow milk varies with the season, and this accounts in part for the seasonal variation in mastitis-causing bacteria and milk spoilage. The microbiota of the cowshed may be the most important factor because the teats of a dairy cow contact bedding material when the cow is resting. The objectives of the present study were to determine whether the microbiota of the milk and the cowshed vary between seasons, and to elucidate the relationship between the microbiota. Methods: We used 16S rRNA gene amplicon sequencing to investigate the microbiota of milk, feces, bedding, and airborne dust collected at a dairy farm during summer and winter. Results: The seasonal differences in the milk yield and milk composition were marginal. The fecal microbiota was stable across the two seasons. Many bacterial taxa of the bedding and airborne dust microbiota exhibited distinctive seasonal variation. In the milk microbiota, the abundances of Staphylococcaceae, Bacillaceae, Streptococcaceae, Microbacteriaceae, and Micrococcaceae were affected by the seasons; however, only Micrococcaceae had the same seasonal variation pattern as the bedding and airborne dust microbiota. Nevertheless, canonical analysis of principle coordinates revealed a distinctive group comprising the milk, bedding, and airborne dust microbiota. Conclusion: Although the milk microbiota is related to the bedding and airborne dust microbiota, the relationship may not account for the seasonal variation in the milk microbiota. Some major bacterial families stably found in the bedding and airborne dust microbiota, e.g., Staphylococcaceae, Moraxellaceae, Ruminococcaceae, and Bacteroidaceae, may have greater influences than those that varied between seasons.

어린이가 생활하는 실내공간의 바닥먼지 중 프탈레이트 농도와 노출수준: DEHP를 중심으로 (Concentrations and Exposure Levels via Intake of Phthalates in Dust Deposits in Indoor Children's Living Areas: Focusing on DEHP)

  • 전성호;김경희;최재욱
    • 한국환경보건학회지
    • /
    • 제48권1호
    • /
    • pp.52-58
    • /
    • 2022
  • Background: Few studies have evaluated the exposure to phthalates via inhalation of floor dust in children's living areas. Objectives: This study evaluated the concentration and exposure level of phthalates emitted from indoor floor dust in children's living areas. Methods: This study utilized the results of a survey conducted by the Ministry of Environment in 2019. Indoor dust was collected from 150 households with children aged 3~7 and 67 daycare centers or local children's centers by using vacuum cleaners. It was analyzed by gas chromatography mass spectrometry. Six types of phthalates were analyzed: Bis (2-ethylhexyl) phthalate (DEHP), Dibutyl phthalate (DBP), Benzyl butyl phthalate (BBP), Di-N-octyl phthalate (DNOP), Diisononyl phthalate (DINP), Di -isodecyl phthalate (DIDP). Results: The medians of DEHP concentrations were 1,028 and 1,937 mg/kg in homes and daycare centers, respectively. The median and maximum values of daily intake were calculated by applying the median and 95th percentile values (the upper 5% of the total concentration) in dust measured in the homes. The DEHP median value was 1.6 ㎍/kg/bw/day, and a maximum A value of 7.8 ㎍/kg/bw/day was calculated. When the childcare center values were applied, the median daily intake of DEHP was 3.1 ㎍/kg/bw/day and the maximum value was 29.2 ㎍/kg/bw/day. As a result of calculating the daily intake by integrating the values of home and childcare facilities, the median and maximum values of daily intake were 1.9 and 10.9 ㎍/kg/bw/day, respectively. Conclusions: This study derives phthalate concentrations among the floor dust in homes and childcare facilities where children mainly spend time, and suggests their intake of phthalates through this. In particular, it was newly suggested that the phthalate concentrations in homes and childcare facilities are different, resulting in differences in intake.

서울시 초등학교 실내 먼지 중 프탈레이트 오염실태 조사 (Phthalates Contamination in Indoor Dust in Elementary Schools in Seoul: A Pilot Study)

  • 이영선;최인자
    • 한국환경보건학회지
    • /
    • 제46권5호
    • /
    • pp.548-554
    • /
    • 2020
  • Objectives: This study is to examine the polyvinyl chloride (PVC) materials in elementary school classrooms and libraries in Seoul, and to investigate phthalate contamination in indoor dust. Methods: PVC material was identified for building materials and furniture using portable x-ray fluorescence (XRF). Phthalates in dust samples (n=19) were extracted by ultrasonic extraction using cyclohexane and analyzed by GC-MS. Results: Diethyl phthalate (DEP), di-n-butyl phthalate (DBP), and Bis (2-ethylhexyl) phthalate (DEHP) were found in all collected dust samples (n=19), and diisonyl phthalate (DINP) was detected in all except for one sample (n=18). The concentration of DEHP (median: 2190 mg/kg) and DINP (2960 mg/kg) were higher than other compounds, suggesting that there are many products in the school that used these compounds. When comparing the phthalate concentration in the classroom (n=11) and library dust (n=8), the total concentration in the classroom (median: 10000 mg/kg) was higher than that in the library (8030 mg/kg). DEHP was the dominant compound in the library. The library is relatively more equipped with PVC furniture (n=83) and most floors are also identified as PVC material, suggesting that floors and furniture made of PVC materials are main sources of DEHP contamination. Conclusions: This study is a pilot survey for investigating phthalate contamination in elementary schools. As a result of the survey, phthalate contamination in elementary school was confirmed. However, further study requires risk assessment of children through analysis of phthalate metabolites in children based on sufficient number of samples and information about the site.

UV 화염감지기의 감지성능에 대한 분진분위기의 영향 (Influence of Dust Environment on the Detection Capability of Ultraviolet Flame Detector)

  • 김홍;호예
    • 한국가스학회지
    • /
    • 제1권1호
    • /
    • pp.113-119
    • /
    • 1997
  • UV 화염감기의 분진분위기에서의 성능저하를 고찰하기 위하여 세제분말, 탄진 및 분말 소화약제의 분진운을 형성하였고 LPG 및 가솔린 화염을 사용하여 UV 화염감지기의 감지성능을 고찰하였다. 분진 분위기 하에서의 UV 화염감지기의 성능을 분진의 농도와 분진층의 거리가 증가함에 따라 뚜렷한 증가를 보였으며, 분진의 화학적, 물리적 특성에 커다란 영향을 받았다. 따라서 UV 화염감지기를 분진 분위기에서 사용한 경우 특별한 주의를 기울일 필요가 있는 것으로 사려된다.

  • PDF

익산지역에서 황사발생시 PM2.5, PM10 TSP의 농도 특성 (Concentration Characteristics of Atmospheric PM2.5, PM10 and TSP during the Asian Dust Storm in Iksan Area)

  • 강공언;김남송;김경숙;김미경;이현주
    • 한국환경보건학회지
    • /
    • 제33권5호
    • /
    • pp.408-421
    • /
    • 2007
  • The concentration characteristics of atmospheric particle matters (PM) including $PM_{2.5},\;PM_{10}$, and TSP were evaluated through the measurement data of PM_{2.5}$ (fine particulate), PM_{10-2.5}$ (coarse particulate), and PM_{over-10}$ collected using a MCI (multi-nozzle cascade impactor) sampler of a three-stage filter pack in spring of 2006 in Iksan area. During the sampling period of 10-15 March and 24 days from 8 April to 2 May, 32 samples for PM of each size fractions were collected, and then measured for PM mass concentrations and water-soluble inorganic ion species. Average concentrations of $PM_{2.5},\;PM_{10}$, TSP were $57.9{\pm}44.1mg/m^3$, $96.6{\pm}89.1mg/m^3$, and $114.8{\pm}99.7mg/m^3$, respectively. Water-soluble inorganic ion fractions to PM mass were found to be 36.5%, 18.0%, and 11.1% for $PM_{2.5}$, $PM_{10-2.5}$ and $PM_{over-10}$, respectively. By showing the high concentrations of PM samples during Asian dust events, those three fractions of PM were distinguished between the samples of Asian dust event and the samples of no event. However, the increase of PM concentrations observed during Asian dust events showed a different pattern for some Asian dust events. The differences of those three fractions in the size distribution may depend on differences on place of occurrence of Asian dust storm and course of transport from China continent to Iksan area in Korea. However, the extent of PM mass contribution during Asian dust events was generally dominated by the coarse particles rather than the fine fraction of PM. The variations of water-soluble inorganic ion species concentration in those three PM fractions between the samples of Asian dust event and the samples of no event were also discussed in this study.

THE PROPERTIES OF DUST EMISSION IN THE GALACTIC CENTER REGION REVEALED BY FIS-FTS OBSERVATIONS

  • Yasuda, A.;Kaneda, H.;Takahashi, A.;Nakagawa, T.;Kawada, M.;Okada, Y.;Takahashi, H.;Murakami, N.
    • 천문학논총
    • /
    • 제27권4호
    • /
    • pp.221-222
    • /
    • 2012
  • We present the results of far-infrared spectral mapping of the Galactic center region with FIS-FTS, which covered the two massive star-forming clusters, Arches and Quintuplet. We find that two dust components with temperatures of about 20 K and 50 K are required to fit the overall continuum spectra. The warm dust emission is spatially correlated with the [OIII] $88{\mu}m$ emission and both are likely to be associated with the two clusters, while the cool dust emission is more widely distributed without any clear spatial correlation with the clusters. We find differences in the properties of the ISM around the two clusters, suggesting that the star-forming activity of the Arches cluster is at an earlier stage than that of the Quintuplet cluster.

SURVEY OF DUSTY ACTIVE GALACTIC NUCLEI BASED ON THE MID-INFRARED ALL-SKY SURVEY CATALOG

  • Oyabu, S.;Ishihara, D.;Yamada, R.;Kaneda, H.;Yamagishi, M.;Toba, Y.;Matsuhara, H.;Nakagawa, T.;Malkan, M.;Shirahata, M.
    • 천문학논총
    • /
    • 제27권4호
    • /
    • pp.265-270
    • /
    • 2012
  • Many observations have found evidence of the presence of a large number of heavily obscured Active Galactic Nuclei (AGNs). However, the nature of this population is only poorly understood because heavy obscuration by dust prevents one from finding them at optical wavelengths. Mid-infrared AGN searches can overcome this obstacle by penetrating through dust and by detecting direct emission from the dust torus. Thus, we can identify most of the AGN population, including type-2 and buried AGNs. Using the AKARI mid-infrared all-sky survey, we performed an AGN search in the nearby universe. Utilizing the 2MASS photometry, we selected mid-infrared-excess sources and carried out near-infrared spectroscopic observations in the AKARI Phase 3. During these follow-up observations, we have found three galaxies that show strong near-infrared red continuum from hot dust with a temperature of about 500 K, but do not show any AGN features in other wavelengths. The most suitable explanation of near-infrared continuum is the presence of central AGNs. Therefore, we conclude that they are AGNs obscured by dust. We performed X-ray observations of the two galaxies with SUZAKU. No detections in the 0.4-10 keV suggest that the column density may be much higher than $N_H=10^{23.5}cm^{-2}$. Comparing the masses of the host galaxies with those of the SDSS AGNs, we find that the host galaxies of the dusty AGNs discovered with AKARI are less massive populations than those of optically selected AGNs.

A Study on Environmental Micro-Dust Level Detection and Remote Monitoring of Outdoor Facilities

  • Kim, Seung Kyun;Mariappan, Vinayagam;Cha, Jae Sang
    • International journal of advanced smart convergence
    • /
    • 제9권1호
    • /
    • pp.63-69
    • /
    • 2020
  • The rapid development in modern industrialization pollutant the water and atmospheric air across the globe that have a major impact on the human and livings health. In worldwide, every country government increasing the importance to improve the outdoor air pollution monitoring and control to provide quality of life and prevent the citizens and livings life from hazard disease. We proposed the environmental dust level detection method for outdoor facilities using sensor fusion technology to measure precise micro-dust level and monitor in realtime. In this proposed approach use the camera sensor and commercial dust level sensor data to predict the micro-dust level with data fusion method. The camera sensor based dust level detection uses the optical flow based machine learning method to detect the dust level and then fused with commercial dust level sensor data to predict the precise micro-dust level of the outdoor facilities and send the dust level informations to the outdoor air pollution monitoring system. The proposed method implemented on raspberry pi based open-source hardware with Internet-of-Things (IoT) framework and evaluated the performance of the system in realtime. The experimental results confirm that the proposed micro-dust level detection is precise and reliable in sensing the air dust and pollution, which helps to indicate the change in the air pollution more precisely than the commercial sensor based method in some extent.