• Title/Summary/Keyword: School Dust

Search Result 539, Processing Time 0.023 seconds

An Investigation for Air Pollutants Emitted from Small-Scale Incinerators in Highway Service Area (고속도로 휴게소의 소형소각로에서 배출되는 대기오염물질 조사)

  • Jang, Young-Kee;Choi, Sang-Jin;Kim, Kwan;Hong, Min-Sun;Choi, Join-In;Moon, Su-Ho;Kim, Soon-Tae;Kim, Seung-Do
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.6
    • /
    • pp.539-546
    • /
    • 2002
  • The physicochemical properties of solid wastes generated from seven highway service areas, four branch offices, and one construction site were analyzed in concert with air pollutants including heavy metals emitted from near-by small-scale incinerators. The amount of solid wastes generated from highway areas has been increasing with recent increases in the number of highways and passengers. Twelve incinerators examined in this study generally had capacity smaller than 100 kg/hr, most of which were equipped with cyclone for dust removal. It was seen that the concentrations of the gas-phase air pollutants (e.g., SO$_2$, NO$_{x}$, HCl and H$_2$S) were above the acceptable emission standards except one or two sites. CO concentrations at all incinerators were also higher due to incomplete combustion. In addition, particulate matters showed concentration six times higher at their maximum. The results of heavy metal analysis showed that the concentrations of Cu, Cd, and Ni satisfied the emission standards. whereas Pb at one site and Zn at five sites exceeded the standards. Cr measurement results indicated that 9 of 12 incinerators had higher values than the standard; especially one branch office showed nine times higher than normal concentration. In order to satisfy more stringent emission standards in the near future, it is necessary to install air pollution control system and to develop an intensified management plan.n.

A Study on the Health Risk Agents in the Workplace of a General Hospital (한 종합병원 작업환경의 건강저해인자에 관한 조사 연구)

  • Kim, Yang-Ok;Kim, Ki-Soon;Park, Jong;Ryu, So-Yeon;Yang, Hee-Yeon
    • Journal of Preventive Medicine and Public Health
    • /
    • v.29 no.1 s.52
    • /
    • pp.1-14
    • /
    • 1996
  • To evaluate the health risk of the workplace environment of a general hospital toward the hospital workers, a questionnaire survey on the perception of risk at the workplace environment and environmental measurements at 27 locations with 240 workers in the hospital were made from October 25th, 1993 to October 30th, 1994. The results were as follows ; 1. By the environmental measurements, 86 workers(36%) were found to be exposed to poor or harmful degree of general illumination, 193 workers(80%) were exposed to poor or harmful local illumination, 34 workers(14%) were exposed to poor or harmful degree of thermal condition and 180 workers(75%) were exposed to poor or harmful noise level, but nobody was exposed to poor or harmful dust and toluene concentration. Also nobody was exposed to poor or harmful level of radiation or anticancer/antibiotic agents. 2. The subjective perceptions on the environmental conditions felt by the workers were different from the objective findings by the environmental measurements. The workers underscored the poor illumination state and overscored the dust concentrations. Also workers oversensitized about the thermal condition, the noise level, the radiation level, the toluene concentration and anticancer/antibiotic agents 3. The sources of noise were the dialogue(179 workers) and the office instruments(131 workers). The sources of dust came from the clothes(108 workers) and the building materials(79 workers). 4. The questionnaire survey showed that the 28 workers were exposed to poor or harmful level of the antibiotics, 10 workers to alkali or acid and 6 workers to drug dust in the pharmacy but the above findings could not be proved by the environmental measurements.

  • PDF

A Study on the Wind Ventilation Forest Planning Techniques for Improving the Urban Environment - A Case Study of Daejeon Metropolitan City - (도시환경 개선을 위한 바람길숲 조성 계획기법 개발 연구 - 대전광역시를 사례로 -)

  • Han, Bong-Ho;Park, Seok-Cheol;Park, Soo-Young
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.51 no.2
    • /
    • pp.28-41
    • /
    • 2023
  • The objective of the study was to develop an Urban Windway Forest Creation Planning Technique for the Improvement of the Urban Environment using the case of Daejeon Metropolitan City. Through a spatial analysis of fine dust and heat waves, a basin zone, in which the concentration was relatively serious, was derived, and an area with the potential of cold air flow was selected as the target area for the windway forest development by analyzing the climate and winds in the relevant zone. Extreme fine dust areas included the areas of the Daejeon Industrial Complex Regeneration Business District in Daedeok-gu and Daedeok Techno Valley in Yuseong-gu. Heat wave areas included the areas of Daedeok industrial Complex in Moksang-dong, the Daejeon Industrial Complex Regeneration Business District in Daehwa-dong, and the high-density residential area in Ojeong-dong. As a result of measuring the wind speeds in Daejeon with an Automatic Weather System, the average wind speeds during the day and night were 0.1 to 1.7 m/s,, respectively. So, a plan of for a windway forest that smoothly induces the movement of cold air formed in outer forests at night is required. The fine dust/heat wave intensive management zones of Daejeon Metropolitan City were Daejeoncheon, Yudeungcheon, Gapcheon-Yudeungcheon, and Gapcheon. The windway forest formation plan case involved the old city center of Daejeon Metropolitan City among the four zones, the Gapcheon-Yudeungcheon area, in which the windway formation effect was presumed to be high. The Gapcheon-Yudeungcheon area is a downtown area that benefits from the cold and fresh air generated on Mt. Gyejok and Mt. Wuseong, which are outer forests. Accordingly, the windway forest was planned to spread the cold air to the city center by connecting the cold air generated in the Seosa-myeon forest of Mt. Gyejok and the Namsa-myeon forest of Mt. Wuseong through Gapcheon, Yudeungcheon, and street forests. After selecting the target area for the wind ventilation forest, a climate map and wind formation function evaluation map were prepared for the area, the status of variation wind profiles (night), the status of fine dust generation, and the surface temperature distribution status were grasped in detail. The wind ventilation forest planning concept and detailed target sites by type were identified through this. In addition, a detailed action plan was established according to the direction of creation and setting of the direction of creation for each type of wind ventilation forest.

Clinical Features, Diagnosis, Management, and Outcomes of Idiopathic Pulmonary Fibrosis in Korea: Analysis of the Korea IPF Cohort (KICO) Registry

  • Jegal, Yangjin;Park, Jong Sun;Kim, Song Yee;Yoo, Hongseok;Jeong, Sung Hwan;Song, Jin Woo;Lee, Jae Ha;Lee, Hong Lyeol;Choi, Sun Mi;Kim, Young Whan;Kim, Yong Hyun;Choi, Hye Sook;Lee, Jongmin;Uh, Soo-Taek;Kim, Tae-Hyung;Kim, Sang-Heon;Lee, Won-Yeon;Kim, Yee Hyung;Lee, Hyun-kyung;Lee, Eun Joo;Heo, Eun Young;Yang, Sei Hoon;Kang, Hyung Koo;Chung, Man Pyo;Korea ILD Study Group,
    • Tuberculosis and Respiratory Diseases
    • /
    • v.85 no.2
    • /
    • pp.185-194
    • /
    • 2022
  • Background: The Korea Interstitial Lung Disease Study Group has made a new nationwide idiopathic pulmonary fibrosis (IPF) registry because the routine clinical practice has changed due to new guidelines and newly developed antifibrotic agents in the recent decade. The aim of this study was to describe recent clinical characteristics of Korean IPF patients. Methods: Both newly diagnosed and following IPF patients diagnosed after the previous registry in 2008 were enrolled. Survival analysis was only conducted for patients diagnosed with IPF after 2016 because antifibrotic agents started to be covered by medical insurance of Korea in October 2015. Results: A total of 2,139 patients were analyzed. Their mean age at diagnosis was 67.4±9.3 years. Of these patients, 76.1% were males, 71.0% were ever-smokers, 14.4% were asymptomatic at the time of diagnosis, and 56.9% were at gender-age-physiology stage I. Occupational toxic material exposure was reported in 534 patients. The mean forced vital capacity was 74.6% and the diffusing capacity for carbon monoxide was 63.6%. Treatment with pirfenidone was increased over time: 62.4% of IPF patients were treated with pirfenidone initially. And 79.2% of patients were treated with antifiboritics for more than three months during the course of the disease since 2016. Old age, acute exacerbation, treatment without antifibrotics, and exposure to wood and stone dust were associated with higher mortality. Conclusion: In the recent Korean IPF registry, the percentage of IPF patients treated with antifibrotics was increased compared to that in the previous IPF registry. Old age, acute exacerbation, treatment without antifibrotics, and exposure to wood and stone dust were associated with higher mortality.

A Study on the Characteristics of Dustfall in Pusan (부산지역 대기 중 강하분진의 특성에 관한 연구)

  • Kim, Eun-Kyoung;Ok, Gon;Kim, Young-Seup
    • Journal of Environmental Science International
    • /
    • v.5 no.4
    • /
    • pp.463-471
    • /
    • 1996
  • In order to investigate the characteristics of dustfall at eight sites in Pusan, the dustfal1 samples were collected with dust jar method from May to September 1995, and Cr, Mn, Fe, Ni, Cu, Zn, Cd and Pb were analyzed, The main results of this study are summarized as follows; 1) The total mean value of dustfall was 11.30 ton/$^{\circ}C$/month. 2) The maximum and minimum values of dustfall were industrial and resident area respectively, 3) The dustfall showed the general trend in order as May>Jun>September>July. 4) The general trend of the heavymetals in dustfall was in order as Fe>Cu>Zn>Pb>Ni>Cd>Cr>Mn any the concentrations of heavymetals had different tendencies according to sources of Pollutant meterials. 5) The Concentrations of Fe, Cu, Pb, Ni, Cd and Cr in industrial area and Mn, Pb and Zn in traffic area were high. The concentrations of heavymetals in residence area and unpolluted area were generally low. 6) Cr, Cu and Cd were influenced by the steel industry and the metal products plant and Zn was influenced by the automobiles. Mn, Fe and Ni were influenced by the soil as wet as artificial outlet. 7) The correlation between the total amount of dustfall and the concentrations of the heavymetals by month was high and the correlation between the heavymetals of the same origin was high.

  • PDF

Simultaneous Determination of Polycyclic Aromatic Hydrocarbons and Their Nitro-derivatives in Airborne Particulates by Using Two-dimensional High-performance Liquid Chromatography with On-line Reduction and Fluorescence Detection

  • Boongla, Yaowatat;Orakij, Walaiporn;Nagaoka, Yuuki;Tang, Ning;Hayakawa, Kazuichi;Toriba, Akira
    • Asian Journal of Atmospheric Environment
    • /
    • v.11 no.4
    • /
    • pp.283-299
    • /
    • 2017
  • An analytical method using high-performance liquid chromatography (HPLC) with fluorescence (FL) detection was developed for simultaneously analyzing 10 polycyclic aromatic hydrocarbons (PAHs) and 18 nitro-derivatives of PAHs (NPAHs). The two-dimensional HPLC system consists of an on-line clean-up and reduction for NPAHs in the 1st dimension, and separation of the PAHs and the reduced NPAHs and their FL detection in the 2nd dimension after column-switching. To identify an ideal clean-up column for removing sample matrix that may interfere with detection of the analytes, the characteristics of 8 reversed-phase columns were evaluated. The nitrophenylethyl (NPE)-bonded silica column was selected because of its shorter elution band and larger retention factors of the analytes due to strong dipole-dipole interactions. The amino-substituted PAHs (reduced NPAHs), PAHs and deuterated internal standards were separated on polymeric octadecyl-bonded silica (ODS) columns and by dual-channel detection within 120 min including clean-up and reduction steps. The limits of detection were 0.1-9.2 pg per injection for PAHs and 0.1-140 pg per injection for NPAHs. For validation, the method was applied to analyze crude extracts of fine particulate matter ($PM_{2.5}$) samples and achieved good analytical precision and accuracy. Moreover, the standard reference material (SRM1649b, urban dust) was analyzed by this method and the observed concentrations of PAHs and NPAHs were similar to those in previous reports. Thus, the method developed here-in has the potential to become a standard HPLC-based method, especially for NPAHs.

Assessment of Airborne Bacteria and Particulate Matters Distributed in Seoul Metropolitan Subway Stations (서울시 일부 지하철역 내 분포하는 부유 세균 및 입자상 오염물질 평가)

  • Kim, Ki-Youn;Park, Jae-Beom;Kim, Chi-Nyon;Lee, Kyung-Jong
    • Journal of Environmental Health Sciences
    • /
    • v.32 no.4 s.91
    • /
    • pp.254-261
    • /
    • 2006
  • In activity areas of subway workers and passengers in Seoul metropolitan subway lines 1-4, mein concentrations of airborne bacteria were relatively higher in workers' bedroom and station precinct whereas concentrations of particulate matters, $PM_{10}$ and $PM_{2.5}$, were relatively higher in platform, inside train and driver's seat as compared with other activity areas. This result indicates that little correlation between airborne bacteria and particulate matters was found, which assumed that most airborne particulate matters distributed in subway consisted of mainly inorganic dust like a metal particles. Mean concentrations of $PM_{10}$ and $PM_{2.5}$ in station precinct and platform exceeded the threshold limit value ($PM_{10}:150{\mu}g/m^3,\;PM_{2.5}:65{\mu}g/m^3$) but those in station office and ticket office were below it. The genera identified in all the activity areas of subway over 5% detection rate were Staphylococcus, Micrococcus, Bacillus and Corynebacterium, of which Staphylococcus and Micrococcus covered over 50% of total airborne bacteria and were considered as predominant genera distributed in subway.

A Study on the Physical Environment of Middle School Classrooms in Winter -Focusing on the Classrooms in Cheju City- (겨울철 중학교교실의 물리적 학습환경실태에 관한 연구 -제주시를 중심으로-)

  • 오인순
    • Journal of the Korean Home Economics Association
    • /
    • v.35 no.3
    • /
    • pp.193-204
    • /
    • 1997
  • The purpose of this study is to measure some physical environmental factors and to doucument students' perceptions of them. 11 middle schools in Cheju City were divided into four areas according to their locations and two schools were selected for the study. 144 thirteen-year-old students in two middle school in a overcrowded area in Cheju City-one middle school building is insulated and the other is not insulated-were taken for the questionnaire survey. The finding of the study are as follows: 1) The classrooms were not equipped with any heating equipment. The buildings are not insulated well. As a result, the room temperature was much lower(12.9-16.2℃) than comfortable indoor temperature in winter(21.5-24.5℃). The classroom were found to be colder(12.9-16.2℃) than usual pleasant indoor temperature(21.5-24.5℃) in winter. 2) The classroom were so far from the street(20m) that there was little noise from traffic. Nevertheless, the noise level was higher(62.5-66.2 dB(A), when the windows were open; 51.7-62.8dB(A), when closed than the noise tolerance level specified in the Environment Protection Laws(50.0dB(A)). 3) As for the visual environment, the location of classroom, the adequate sun exposure, and the total states of windows in classrooms influenced on the illuminance. While standard indoor illuminance is 300 Lux, the classrooms facing south had illuminance of 231 Lux, from day light: and the ones facing west, 380 Lux. 4) Students generally found other aspects of the physical environment of their classrooms unsatisfactory. Chalk dust was generated to a serious extent near the main chalkboard(0.25mg/㎥) of classrooms.

  • PDF

A Comparison between Wet-only and Bulk Deposition at Two Forest Sites in Japan

  • Imamura, Naohiro;Iwai, Noriko;Tanaka, Nobuaki;Ohte, Nobuhito
    • Asian Journal of Atmospheric Environment
    • /
    • v.12 no.1
    • /
    • pp.67-77
    • /
    • 2018
  • To investigate the effects of forest and the surrounding natural and anthropogenic sources on the bulk depositions on forested land, this study examined differences in ion concentrations between wet-only and bulk samples at two forested sites in Japan. The surrounding natural and anthropogenic sources at each site were different; Shirasaka is in a rural area and Tanashi is an urban environment. The volume weighted (vw) mean concentrations of $K^+$ and $Ca^{2+}$ in the bulk samples were significantly (p<0.05) higher than those in the wet-only samples at both sites. The forest canopy and a nearby incineration plant were hypothesized to be the main sources of $K^+$ contaminants at Shirasaka and Tanashi, respectively. The transport of sea salt and urban dust may explain the presence of enriched $Ca^{2+}$ concentrations in the bulk samples at Shirasaka and Tanashi, respectively. The $NH_4{^+}$ concentrations in the Shirasaka bulk samples were significantly (p<0.05) lower than those in the wet-only samples. The vw mean $SO{_4}^{2-}$ and $NO_3{^-}$ concentrations in both sample types were not significantly different at either site. This study demonstrated that the ion concentration differences between wet-only and bulk samples were affected by nearby natural and anthropogenic sources even at forest sites, similar to previous findings for non-forested locations. However, the $K^+$ concentration differences between wet-only and bulk samples may be higher owing to forest sources, even in the absence of anthropogenic sources.

Effective Arrangement of Non-explosive Demolition Agents and Empty Holes for Improving Fragmentation of Square Concrete Structures (정사각형 콘크리트 구조물의 파쇄도 향상을 위한 비폭성 파쇄제와 천공 홀의 효과적인 배치)

  • Cho, Hwangki;Nam, Yunmin;Kim, Kyeongjin;Lee, Jaeha;Sohn, Dongwoo
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.30 no.2
    • /
    • pp.145-151
    • /
    • 2017
  • As an alternative to conventional explosive methods for demolition of concrete structures and rocks, the use of non-explosive demolition agents can be considered to reduce noise, vibration, and dust emissions during the demolition process. In this study, we conduct finite element analysis for crack initiation and propagation caused by the expansion of non-explosive demolition agents in square concrete structures. The predicted crack patterns are compared with the experimental results in the literature. The minimum values of the required expansion pressure of non-explosive demolition agents are also estimated, which depend upon the arrangement of non-explosive demolition agents and empty holes. Furthermore, we investigate the effect of empty holes on the fragmentation of concrete structures, and discuss the effective arrangement of non-explosive demolition agents and empty holes for fragmentation improvement.