• 제목/요약/키워드: Scattering efficiency

검색결과 303건 처리시간 0.027초

문 개폐 여부와 차폐체 설치 유무에 따른 공간산란선량 측정 : X선 촬영 시 피폭선량 감소방안에 대한 연구 (Measurement of the Spatial Scattering Dose by Opening, Closing Door and Installing Shielding : A Study on the Reduction of Exposure Dose in Radiography)

  • 윤홍주;이용기;이인자
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제42권6호
    • /
    • pp.477-482
    • /
    • 2019
  • Recently, due to the increased use of medical radiation, the radiation exposure of radiation workers should be considered as well as medical exposure of patients. And it is recommended to close the door during radiography. however, In this study, when the door was inevitably opened for radiography, the proposed method was to install the shield as a method of reducing the exposure dose. And its efficiency was analyzed. In simple chest radiography, the measurement point was changed according to the measurement location. Dose rate were measured 10 times for each condition using a dosimeter. And the average value was derived. Using this, the change of dose according to the opening and closing of the door and the installation of the shield was analyzed. Using this, we compared and analyzed the dose change according to the door opening and closing and the installation of the shield, and significance was verified through the SPSS ver. 24. Depending on whether the door was opened or closed, 11,215.35%, 159.0%, 101.9% increased in front of the door in the consol room, behind the wall and behind the lead glass. Depending on the installing of the shield, the 49.2%, 29.6%, 19.9%, 30.6% decrease in front of the door in the examination and consol room, behind the wall and lead glass. In addition, statistical analysis was showed that there were significant differences in both the results according to whether the door was opened or closed and shielding(p<.05). Close the door during radiography. However, when the door should be opened, it was confirmed that the dose rate were reduced by installing the shield. Therefore, to optimize radiation protection, it is recommended to install shields when opening the door.

공중화분에 의한 시정장애 현상의 물리적 및 화학적 특성 규명 (Physico-Chemical Characteristics of Visibility Impairment by Airborne Pollen)

  • 김경원
    • 한국대기환경학회지
    • /
    • 제22권6호
    • /
    • pp.863-875
    • /
    • 2006
  • Intensive visibility monitoring was conducted to investigate physical and chemical characteristics of visibility impairment by airborne pollen. Light attenuation coefficients were optically measured by a transmissometer, a nephelometer, and an aethalometer. Elemental, ionic, and carbonaceous species were chemically analyzed on the filters collected by $PM_{2.5}$ and $PM_{10}$ samplers. Aerosol size distribution was analyzed using a cascade impactor during airborne pollen period. Airborne pollen count was calculated using a scanning electron microscope. Airborne pollen was emitted into the atmosphere in springtime and funker degraded visibility through its scattering and absorbing the light. Average light extinction coefficient was measured to be $211{\pm}36Mm^{-1}$ when airborne pollen was not observed. But it increased to $459{\pm}267Mm^{-1}$ during the airborne pollen period due to increase of average $PM_{2.5}$ and $PM_{10}$ mass concentration and relative humidity and airborne pollen count concentration for $PM_{10}$, which were measured to be $46.5{\pm}29.1{\mu}g\;m^{-3},\;97.0{\pm}41.7{\mu}g\;m^{-3},\;54.1{\pm}11.6%$, and $68.2{\pm}89.7m^{-3}$, respectively. Average light extinction efficiencies for $PM_{2.5}$ and $PM_{10}$ were calculated to be $5.9{\pm}0.9$ and $4.5{\pm}0.8m^2 g^{-1}$ during the airborne pollen period. Light extinction efficiency for $PM_{10}$ increased further than that for $PM_{2.5}$. The average light extinction budget by airborne pollen was estimated to be about 24% out of the average measured light extinction coefficient during the airborne pollen period.

차세대 네트워크에서 모바일 액세스 계층의 성능 평가 (Performance Evaluation of Mobile Across Layer in Next Generation Network)

  • 노재성;문일영
    • 디지털콘텐츠학회 논문지
    • /
    • 제6권2호
    • /
    • pp.101-106
    • /
    • 2005
  • 본 논문에서는 레일리 페이딩 채널에서 다중접속 간섭의 제거와 시스템 채널 용량의 증가를 위해 MIMO-MC/CDMA 16QAM 시스템의 모바일 액세스 계층에 대한 성능을 평가하였다. 전통적으로 무선통신에서 다중경로는 불필요한 요소로 여겨졌다. 따라서 다이버시티와 적응 어레이 방식이 다중경로를 제거하기 위하여 제안되었다. 최근에는 스펙트럼 효율과 링크의 신뢰도를 증가하기 위하여 다중경로를 이용하는 MIMO방식이 제안되었다. 특히, MIMO-MC/CDMA 16QAM 시스템의 채널 용량이 Eb/No, Mc, p에 따라서 평가되었다. 결과로부터 채널용량을 개선하기 위해서는 신호의 요소들은 서로 무상관이어야 하며 만약 부적당한 공간과 상호 결합 효과에 의하여 경로사이가 상관이 이루어지면 MIMO-MC/CDMA 16 QAM시스템의 채널 용량은 상당히 감소하게 된다.

  • PDF

MIMO 부분간섭 채널에서 멀티미디어 서비스를 위한 무선 네트워크의 성능 (Performance of Wireless Network for Multimedia Services in MIMO Partial Band Channel)

  • 노재성;조성준;김춘길
    • 디지털콘텐츠학회 논문지
    • /
    • 제6권3호
    • /
    • pp.137-142
    • /
    • 2005
  • CDMA 방식은 미래의 모바일 네트워크를 위한 다중접속 방식으로 많은 주목을 받고 있으며 높은 무선 용량과 유연한 데이터 전송에 대한장점을 가지고 있다. 그리고 CDMA방식은 실시간 음성 및 비실시간 데이터 서비스를 제공하는 차세대 멀티미디어 시스템 분야에서 ITU에 제안된 주요 기술이다. 본 논문에서는 무선 채널에서 다중 접속 간섭 및 부분 대역 간섭의 제거와 시스템 채널 용량의 증가를 위해 MIMO-MC/CDMA 시스템의 용량을 평가하였다. 최근에 스펙트럼 효율과 링크의 신뢰도를 증가하기 위하여 다중경로를 이용하는 MIMO 방식이 제안되고 있다. 특히, 본 논문에서는 MIMO-MC/CDMA시스템의 채널 용량을 Eb/No, Mc, p, B에 따라서 평가하였다. 얻어진 결과로부터 채널용량을 개선하기 위해서는 신호의 요소들은 서로 무상관이어야하며 만약 부적당한 공간에 의한 상관과 부분 대역 간섭에 의한 주파수 간섭이 발생하만 MIMO-MC/CDMA 시스템의 채널 용량은 상당히 감소하게 됨을 알 수 있었다.

  • PDF

함정적외선신호 관리를 위한 확률론적 방법의 가능성 연구 (A Feasibility Study on the Probabilistic Method for the Naval Ship Infra-red Signature Management)

  • 박현정;강대수;조용진
    • 대한조선학회논문집
    • /
    • 제56권5호
    • /
    • pp.383-388
    • /
    • 2019
  • It is essential to reduce the Infra-red signature for increasing ship's survivability in ship design stage. However the ship's IR signature is quite sensitive to the maritime and atmosphere. Therefore, it is very important to select the marine meteorological data to be applied to the signature analysis. In this study, we selected the three meteorological sample sets from the population of the Korea Meteorological Administration's marine environment data in 2017. These samples were selected through the two-dimensional stratified sampling method, taking into account the geopolitical threats of the Korean peninsula and the effective area of the buoy. These sample sets were applied to three naval ships classified by their tonnage, and then the IR signature analysis was performed to derive the Contrast Radiant Intensity (CRI) values. Based on the CRI values, the validity of each sample set was determined by comparing Cumulative Distribution Function (CDF), and Probability Density Function (PDF). Also, we checked the degree of scattering in each sample set and determined the efficiency of analysis time and cost according to marine meteorological sample sets to confirm the possibility of a probabilistic method. Through this process, we selected the standard for optimization of marine meteorological sample for ship IR signature analysis. Based on this optimization sample, by applying probabilistic method to the management of IR signature for naval ships, the robust design is possible.

Multimodal Nonlinear Optical Microscopy for Simultaneous 3-D Label-Free and Immunofluorescence Imaging of Biological Samples

  • Park, Joo Hyun;Lee, Eun-Soo;Lee, Jae Yong;Lee, Eun Seong;Lee, Tae Geol;Kim, Se-Hwa;Lee, Sang-Won
    • Journal of the Optical Society of Korea
    • /
    • 제18권5호
    • /
    • pp.551-557
    • /
    • 2014
  • In this study, we demonstrated multimodal nonlinear optical (NLO) microscopy integrated simultaneously with two-photon excitation fluorescence (TPEF), second-harmonic generation (SHG), and coherent anti-Stokes Raman scattering (CARS) in order to obtain targeted cellular and label-free images in an immunofluorescence assay of the atherosclerotic aorta from apolipoprotein E-deficient mice. The multimodal NLO microscope used two laser systems: picosecond (ps) and femtosecond (fs) pulsed lasers. A pair of ps-pulsed lights served for CARS (817 nm and 1064 nm) and SHG (817 nm) images; light from the fs-pulsed laser with the center wavelength of 720 nm was incident into the sample to obtain autofluorescence and targeted molecular TPEF images for high efficiency of fluorescence intensity without cross-talk. For multicolor-targeted TPEF imaging, we stained smooth-muscle cells and macrophages with fluorescent dyes (Alexa Fluor 350 and Alexa Fluor 594) for an immunofluorescence assay. Each depth-sectioned image consisted of $512{\times}512$ pixels with a field of view of $250{\times}250{\mu}m^2$, a lateral resolution of $0.4{\mu}m$, and an axial resolution of $1.3{\mu}m$. We obtained composite multicolor images with conventional label-free NLO images and targeted TPEF images in atherosclerotic-plaque samples. Multicolor 3-D imaging of atherosclerotic-plaque structural and functional composition will be helpful for understanding the pathogenesis of cardiovascular disease.

Phase Behavior and Spontaneous Vesicle Formation in Aqueous Solutions of Anionic Ammonium Dodecyl Sulfate and Cationic Octadecyl Trimethyl Ammonium Chloride Surfactants

  • Kang, Kye-Hong;Kim, Hong-Un;Lim, Kyung-Hee
    • Bulletin of the Korean Chemical Society
    • /
    • 제28권4호
    • /
    • pp.667-674
    • /
    • 2007
  • Phase behavior for the mixed aqueous surfactant systems of cationic octadecyl trimethyl ammonium chloride (OTAC)/anionic ammonium dodecyl sulfate (ADS)/water was examined. Below the total surfactant concentrations of 1.5 m molal, mixed micelles were formed. At the total surfactant concentrations higher than 1.5 m molal, there appeared a region where mixed micelles and vesicles coexist. As the surfactant concentration increased, the systems looked very turbid and much more vesicles were observed. The vesicles were spontaneously formed in this system and their existence was observed by negative-staining transmission electron microscopy (TEM), small-angle neutron scattering (SANS) and encapsulation efficiency of dye. The vesicle region was where the molar fraction α of ADS to the total mixed surfactant was from 0.1 to 0.7 and the total surfactant concentration was above 5 × 10-4 molality. The size and structure of the vesicles were determined from the TEM microphotographs and the SANS data. Their diameter ranged from 450 nm to 120μm and decreased with increasing total surfactant concentration. The lamellar thickness also decreased from 15 nm to 5 nm with increasing surfactant concentration and this may be responsible for the decrease in vesicle size with the surfactant concentration. The stability of vesicles was examined by UV spectroscopy and zeta potentiometry. The vesicles displayed long-term stability, as UV absorbance spectra remained unchanged over two months. The zeta potentials of the vesicles were large in magnitude (40-70 mV) and the observed longterm stability of the vesicles may be attributed to such high ζ potentials.

LIEE와 Mie 산란 방법을 이용한 직분식 가솔린 엔진의 스월 및 슬릿 인젝터의 분무 특성 (The Spray Characteristics of Swirl and Slit Injector to DISI Engine Using LIEF and Mie-scattering Method)

  • 이기형;황규민;이창희
    • 대한기계학회논문집B
    • /
    • 제29권3호
    • /
    • pp.356-367
    • /
    • 2005
  • The spray characteristics of DISI injector have a great role in gasoline engine efficiency and emission. Thus, many researchers have studied to investigate the spray characteristics of swirl and slit injectors that are used in a DISI engine. In this study, we tried to provide spray parameters, which affect on the spray characteristics such as injection pressure, ambient pressure and ambient temperature. In addition, we calculated $t_{b}\;and\;t_{c}$ to investigate the break up mechanism of test injectors and obtained $C_{v}$ to evaluate the spray characteristics. As the ambient pressure increases in case of slit injector, $C_{v}$ decreases. The laser-induced exciplex fluorescence (LIEF) technique, which is based on spectrally resolved two-color fluorescent emissions, has applied to measure the liquid and vapor phases for on evaporating spray simultaneously. The TMPD/naphthalene proposed by Melton is used as a dophant to detect exciplex signal. The temporal and spatial distribution of liquid and vapor phases during the mixture formation process was measured by this technique. In the LIEF technique, the vapor phase is detected by the monomer fluorescence while the liquid phase is tracked by the exciplex fluorescence. From this experiment, we found that the spray area of the vapor phase is increased with elapsed time after injection and the area of liquid is decreased when the ambient pressure is 0.1MPa. However, the area tends to increase until the end of injection when the ambient pressure is 1.0MPa.

연안 해저 재질 분석을 위한 초분광영상의 보정 방법 (Method of Correcting Hyperspectral Image for Seabed Material Analysis of Coastal Area)

  • 신명식;신정일;김익재;서용철
    • 한국지리정보학회지
    • /
    • 제19권2호
    • /
    • pp.107-116
    • /
    • 2016
  • 연안 해저 재질 조사에 있어 위성 및 항공 원격탐사 자료를 이용하면 기존 현장조사 방법에 비해 효율성을 높일 수 있으나, 물에 의한 빛의 흡수 특성으로 인해 동일한 조건이더라도 수심에 따라 영상에서 다른 반사도를 보이게 된다. 따라서 본 연구에서는 초분광영상을 연안 해저 재질 분석 자료로 사용하기 위한 보정 방법을 제시하고자 한다. 연구지역은 강원도 사천진항에서 경포해수욕장 일대이고, 사용한 초분광영상은 CASI-1500 영상이다. 수체 반사율과 수심 간의 회귀모델을 통해 밴드별 산란흡수계수를 추정하여 영상에 적용하였다. 그 결과 수심보정 전 영상에서 매우 얕은 수심에 한정하여 판독이 가능하였지만 수심보정 후 상대적으로 깊은 수심까지 판독이 가능해지고, 수심에 따른 해저면의 반사율 변이가 크게 감소한 것을 알 수 있었다.

실리콘 결정면을 이용한 LCD-BLU용 도광판의 미세산란구조 형성 (Micro-patterning of light guide panel in a LCD-BLU by using on silicon crystals)

  • 최가을;이준섭;송석호;오차환;김필수
    • 한국광학회지
    • /
    • 제16권2호
    • /
    • pp.113-120
    • /
    • 2005
  • LCD-BLU(liquid crystal device-back light unit)에 사용되는 도광판의 미세 산란패턴을 만드는 새로운 방법으로서, 실리콘 웨이퍼의 비등방 식각에 의해 자연적으로 형성되는 3차원 결정면 구조를 이용하는 방법을 제안하였다. 실리콘 3차원 결정면을 갖는 도광판과 프리즘 시트의 원판을 설계 및 제작하였고, casting 공정을 통해 PDMS 재질로 복제된 도광판을 제작하여 특성을 분석하였다. 측정 결과, 기존 인쇄형 도광판에 비해 실리콘피라미드 패턴의 도광판이 $10\%$ 증가된 정면 휘도 효율을 가질 수 있음을 실험적으로 검증하였다.