• 제목/요약/키워드: Scattering Coefficient

검색결과 318건 처리시간 0.034초

90% $Bi_2Te_3-10% Bi_2Se_3$ 단결정의 밴드갭 에너지와 열전특성 (Band-Gap Energy and Thermoelectric Properties of 90% $Bi_2Te_3-10% Bi_2Se_3$ Single Crystals)

  • 하헌필;현도빈;황종승;오태성
    • 한국재료학회지
    • /
    • 제9권4호
    • /
    • pp.349-354
    • /
    • 1999
  • Dopant를 첨가하지 않은 시료와 donor dopant로 $CdI_2$를 첨가한 $Bi_2Te_3-10%$ 단결정을 Bridgman법으로 성장시키고 Hall 계수, 전하이동도, 전기비저향, Seebeck 계수, 열전도도 빛 성능지수를 77~600K의 온도범위에서 측정하였다. Dopant를 첨가하지 않은 90% $Bi_2Te_3-10% Bi_2Se_3$ 단결정에서 포화정공농도는 $5.85\times10_{18}cm^{-3}$ 이고 degenerate 온도는 127K 이었£며, 전하 이동에 대한 산란인자는 -0.23 이고 전자이동도와 정꽁이동도의 비 ($\mu_e/\mu_h)$는 1.45 이었다. 90% $Bi_2Te_3-10% Bi_2Te_3$ 단결정의 OK 에서의 밴드갭 에너지는 0.200 eV 로서 $Bi_2Te_3-Bi_2Se_3$계 단결정에서눈 $Bi_2Se_3$의 놓도가 증가할수록 밴 드갭 에너지가 증가하였다. Donor dopant로 $CdI_2$를 첨가한 90% $Bi_2Te_3-Bi_2Se_3$ 조성의 n형 단결정에서 성능지수의 최대값은 $CdI_2$를 0.05 wt% 첨가한 경우에 약 230K에서 $3.2\times10^{-3}/K$를 나타내었다.

  • PDF

증기화광산란 검출기를 이용한 콩 함유 수용성 탄수화물의 분석 (Determination of Soluble Carbohydrates in Soybean Seeds Using High Performance Liquid Chromatography with Evaporative Light Scattering Detection)

  • 김경하;황영선;안경근;김기쁨;김민지;홍승범;문중경;정명근
    • 한국식품영양과학회지
    • /
    • 제43권7호
    • /
    • pp.1062-1067
    • /
    • 2014
  • 콩 함유 수용성 탄수화물의 동시분석 시 증기화광산란검출법(HPLC/ELSD) 및 굴절율검출법(HPLC/RID)의 분석 효율성, 정밀성 및 재현성을 상호 비교, 평가하여 콩 함유 수용성 탄수화물의 효율적 분석방법을 제공하고자 하였다. HPLC/ELSD 분석법 적용 시 콩 함유 수용성 탄수화물의 정량한계(LOQ)를 확인한 결과 5.6~7.6 mg/kg 범위를 나타낸 반면, RID는 16.2~33.9 mg/kg 범위를 나타내어 HPLC/ELSD 분석법이 RID 분석법 대비 감도가 향상된 양상을 확인하였고, intra-day(n=10) 및 inter-day(n=5) 분석재현성 평가에서도 피크의 머무름 시간(Rt.) 및 면적(peak area) 모두 최대 2.5% 미만의 변이계수를 나타내어 높은 분석 재현성을 확인할 수 있었다. 또한 농도별 표준시약을 이용하여 검량식의 직선성을 확인한 결과 모든 성분이 고도의 직선성($R^2$ >0.999)이 유지되어 정량적 분석이 가능함을 확인하였다. 콩 함유 수용성 탄수화물의 함량을 HPLC/ELSD 및 RID 방법으로 상호 비교한 결과 HPLC/ELSD 분석법을 적용하였을 경우 RID 분석법 대비 각 수용성 탄수화물의 함량이 더 높게 평가됨을 확인할 수 있었다.

대관령 구름물리관측시스템 산출물 평가 및 FSSP를 이용한 시정환산 시험연구 (Intercomparison of Daegwallyeong Cloud Physics Observation System (CPOS) Products and the Visibility Calculation by the FSSP Size Distribution during 2006-2008)

  • 양하영;정진임;장기호;차주완;정재원;김유철;이명주;배진영;강선영;김금란;최영진;최치영
    • 대한원격탐사학회지
    • /
    • 제26권2호
    • /
    • pp.65-73
    • /
    • 2010
  • 구름과 강수특성을 분석하기 위해 대관령에 구름물리관측시스템(Cloud physics Observation System, 이하 CPOS)을 2003년부터 운영해 오고 있다. 주요 관측 기기는 다음과 같다: FSSP (Forward Scattering Spectrometer Probe), OPC (Optical Particle Counter), VS (Visibility Sensor), PARSIVEL disdrometer, MWR (Microwave Radiometer), MRR (Micro Rain Radar). 앞의 4개 장비는 지상구름 (안개)과 강수 특성을, 뒤의 2개 장비는 연직구름의 특성을 실시간으로 관측하고 있다. CPOS 산출물을 검증하기 위해 FSSP는 흡습성 물질 시딩 실험 중 OPC와, MWR의 가강수량은 라디오존데와, PARSIVEL과 MRR은 우량계와 비교 연구가 수행되었다. 그 결과를 보면 대부분이 0.7이상의 좋은 상관도를 보인다. 이와 같이 신뢰도를 확보한 CPOS 관측 자료는 구름과 에어로솔의 간접효과나 기상조절 실험에 유용한 자료로 활용될 수 있을 것이다. FSSP의 입자 크기 분포를 시정값으로 환산해 보았으며 FSSP 환산 시정값은 visibility sensors (SVS)와 PWD22 (Present Weather Detect 22)의 시정계 값에 비해 1.7~1.9배 과도한 경향을 보였다. 이는 FSSP에 의해 관측되는 입자 크기($2{\sim}47\;{\mu}m$)의 한계 때문으로 사료된다. 향후 다른 입자크기분포를 측정할 수 있는 장비를 도입하여 추가 분석을 추진할 계획이다.

CAGEX 관측자료를 이용한 LOWTRAN7의 대기 복사전달 모의에 대한 조사 (Study on the LOWTRAN7 Simulation of the Atmospheric Radiative Transfer Using CAGEX Data.)

  • 장광미;권태영;박경윤
    • 대한원격탐사학회지
    • /
    • 제13권2호
    • /
    • pp.99-120
    • /
    • 1997
  • 위성 탐사 지구 관측 자료, 특히 가시광선 영역의 자료는 태양광이 지구 대기계와 복잡 한 상호 작용을 거친후 위성센서에 의해서 감지되어 수집된 것이다. 따라서 가시광선 영역의 지 구 관측 위성 자료를 정량적으로 분석하기 위해서는 대기의 산란과 흡수에 의한 대기효과에 대한 정량적 보정이 필요하다. 본 연구에서는 대기효과에 대한 정량적 보정을 위해서 복사 전달 모델 의 활용 가능성을 조사하였다. 이를 위해 위성 원격탐사 응용 분야에 이용되고 있는 복사 전달 모델 중의 하나인 LOWTRAN7의 복사 전달 모의 결과 중 단파 자료를 복사 관측 자료인 CAGEX 자료와 비교하였다. CAGEX 관측 자료는 대기복사 모델의 검정을 위하여 NASA Langley Research Center에서 수집한 자료로써, 1)대기 sounding, aerosols, 구름의 특성 자료, 2) 지구복사계, 직달일사계, 차광전천일사계에 의해 측정된 ARM(Aerosol Radiation Measurement) 자료, 3)Fu-Luio 모델에 의해 모의된 장파, 단파 flux 등의 자료로 구성되어 있다. 대기복사 전달 모의를 위하여 에어로졸의 광학적 특성은 CAGEX의 column optical depth, Spinhime의 산란 계 수 수직 분포와 D' Almeida의 에어로졸 복사 특성 값으로부터 도출되었다. LOWTRAN7의 복사 모의는 완전히 맑은 날에 해당하는 31개의 경우에 대하여 수행되었으며, 이 모의 결과 중 단파영 역에서의 지표면에서의 상향복사와 지표면으로의 하향직달복사 및 하향 확산 복사 그리고 대기 상단에서의 상향 복사를 CAGEX 관측 자료와 각각 비교 하였다. 비교 결과 CAGEX 자료에 대한 LOWTRAN7 결과의 표준 오차는 지표면에서의 하향 확산 복사(6.9%)를 제외한 모든 복사 항목 들이 5%이내였다. 이 결과로 보아 하향 확산 복사항의 오차가 가장 크며 이 오차가 관련된 나머 지 항목의 오차를 일으키는 역할을 하는 것으로 추측할 수 있다. 결론적으로 지표면에서의 하향 확산 복사 항목은 에어로졸에 의해 생기는 항목이므로 향후 복사 모델을 고려할 때 에어로졸의 산란에 의한 부분이 더 고려 된다면 복사 전달 모델을 이용하여 정량적으로 대기 효과를 보정하 는데 오차를 줄일 수 있을 것으로 기대된다.

5 MHz 신호를 이용한 부유물의 농도에 따른 후방산란강도 측정 (5-MHz Volume Backscattering Strength Measurements from Suspended Sediment Concentrations)

  • 이찬길;최지웅
    • 한국음향학회지
    • /
    • 제32권1호
    • /
    • pp.14-21
    • /
    • 2013
  • 연안 및 하구지역은 퇴적물의 침식, 부유, 이동이 활발하게 이루어지며, 이로 인해 유성머드와 같은 고농도의 부유퇴적물 환경이 조성된다. 유성머드는 주로 실트, 점토와 같이 매주 작은 입자들로 이루어져 있는 10 g/l 이상의 고농도 환경으로써, 유성머드의 분포 및 특성 파악을 위해 초음파와 같이 분해능이 우수한 높은 주파수 특성을 이용한 연구가 필요하다. 음파가 부유퇴적물에 의해 산란될 때, 부유퇴적물의 농도가 높아질수록 후방산란강도의 세기가 증가하지만, 점성 및 산란에 의한 감쇠도 함께 증가하기 때문에 농도에 따른 올바른 감쇠계수 보상이 요구된다. 본 논문에서는 5 MHz 주파수 특성을 바탕으로 간이 수조에서 농도에 따른 가상의 유성머드 환경을 조성한 뒤, 후방산란강도를 측정하였다. 또한 Richards의 감쇠계수 모델을 이용하여 부유물의 특성 및 농도에 따른 감쇠계수를 계산하였고, 이를 후방산란강도를 계산하는 소나방정식에 적용하여 부유물 농도에 따른 후방산란강도를 예측하였다. 그 결과 부유물에 의한 감쇠를 보상하지 않았을 경우 부유물 농도 증가에 따라 후방산란강도 값이 함께 증가하는 경향을 보이다가 일정 농도(20 g/l) 이후부터는 부유물의 농도가 증가하여도 후방산란강도가 더 이상 증가하지 않았다. 반면, 농도에 따른 감쇠계수를 보상해 주었을 경우는 부유물 농도 증가에 따라 후방산란강도가 연속적으로 증가하였다. 이러한 결과는 고농도의 부유퇴적물 환경에서 음파에 의한 산란강도를 정확히 예측하기 위해서는 부유물 농도에 따른 감쇠효과 고려가 필요함을 보여준다.

서울시 지하철 객차내에서의 미세먼지 농도 평가 (A Study of PM levels in Subway Passenger Cabins in Seoul Metropolitan area)

  • 노영만;박화미;이철민;김윤신;박동선;김석원
    • 한국산업보건학회지
    • /
    • 제17권1호
    • /
    • pp.13-20
    • /
    • 2007
  • This study was performed to investigate the concentrations of PM($PM_{10}$, $PM_{2.5}$, $PM_{1}$) and it's affecting factors in the subway from line 1 to line 8 in Seoul metropolitan area, from Sep. 1 to 30, 2005. PM concentrations were measured at the entrances and centers in subway passenger cabins by a light scattering equipment. And the affecting factors to PM were estimated based on the number of passenger, door open and close and running area etc. The geometric means of $PM_{10}$, $PM_{2.5}$ and $PM_{1}$ concentration in Seoul subway passenger cabins were $214{\mu}g/m^3$, $86.6{\mu}g/m^3$ and $27.0{\mu}g/m^3$, respectively. These mean concentrations in subway carriage were higher when it ran on an underground track than on a ground track. And running time(7AM-9AM, 11AM-13PM, 6PM-8PM) significantly influenced to the concentrations of $PM_{10}$, $PM_{2.5}$ and $PM_{1}$. Daily profile of $PM_{10}$ and $PM_{2.5}$, $PM_{1}$ expressed as an 10 minutes average, showed similar variation pattern over day period. In correlation analysis, significant relations among $PM_{10}$, $PM_{2.5}$ and $PM_{1}$ were detected(p〈0.01). In particular, correlation coefficient between $PM_{10}$and $PM_{1}$ was highly significant(r=0.94). Further study is needed to identity the sources of PM in subway cabins and to compare pollutants concentration among subway lines.

O/W 유제의 물리적 안정성에 대한 PVP의 영향 (Effect of PVP on the Physical Stability of O/W Emulsion)

  • 오인준;이미영;이정민;이용복;신상철;최보길;김종국
    • Journal of Pharmaceutical Investigation
    • /
    • 제27권4호
    • /
    • pp.287-293
    • /
    • 1997
  • To make a stable o/w emulsion, the effects of egg lecithin as an emulsifier and polyvinylpyrrolidone (PVP) as an auxiliary emulsifier on the physical stability of emulsion were investigated. The oil-in-water emulsion system was manufactured by microfluidizer and evaluated the physical stability. Average particle size and size distribution of emulsion was measured by dynamic light scattering analyzer and interfacial tension was measured. From the interfacial tension tested, critical micelle concentration of the egg lecithin was 0.1 %w/v and optimal concentration for the preparation of emulsion was 1.0 %w/v. The mean particle size was about $0.2\;{\mu}m$ which was suitable for injections. The short-term accelerated stability studies were conducted by centrifugation, freeze-thaw method and shaking of the emulsion samples. The addition of PVP was caused the reduction in the particle size and improved the physical stability of emulsion. These results suggested that a mixed interfacial film comprising the egg lecithin and PVP was formed at the o/w interface and it was effective in preventing phase separation under thermic or mechanical stress. We used antineoplaston A10 (A10) as a model drug which is peptide and amino acid derivative having a action to the living organism against the development of neoplastic growth by a nonimmunological progress. It has a poor solubility in water and there may be a difficulty in formulation of A10. Emulsion formulation study about A10 was performed. Solubility of A10 in emulsion was about five times as high as that in water. From the results of solubility and partition coefficient, almost A10 molecules in o/w emulsion exist in the interface between oil and water.

  • PDF

XPS, ISS, AES, TPD를 이용한 $TiO_2$ 위에 지지된 Au 클러스터의 특성 연구 (Properties of Au Clusters Supported on $TiO_2$ Studied by XPS, ISS, AES, and TPD)

  • 김대영
    • 대한화학회지
    • /
    • 제42권6호
    • /
    • pp.607-617
    • /
    • 1998
  • $TiO_2(001)$ 박막을 Mo(100) 기판에 약 90${\AA}$ 두께로 적층 성장시키고 그 위에 Au를 증착시켜서 Au의 성장모드, 클러스터의 열적 변화, 열적 안정성, 증착량에 따른 Au 4f 전자 결합에너지의 변화를 오제 전자분광법, 열탈착 분광법, 이온 산란 분광법, X-선 광전자 분광법을 이용하여 연구하였다. Au는 $TiO_2(001)/Mo(100)$ 박막에 3차원적인 성장을 하며 낮은 온도에서 성장된 Au 클러스터는 높은 온도에서 성장된 것보다 보다 그 크기가 작고 온도가 높아지면서 클러스터는 비가역적으로 뭉친다. $TiO_2(100)/Mo(100)$에 증착된 Au의 열탈착은 1000 K부터 일어나며, 증착된 Au의 증착량이 많아질수록 더 높은 온도에서 나타난다. 선도 언저리 해석법으로 얻은 Au 클러스터의 탈착에너지는 약 50 kcal/mol이다. Au의 $TiO_2$ 박막에 대한 초기 흡착상수는 기판의 온도 200-600 K 사이에서는 거의 일정하였다. 400 K에서 $TiO_2$ 박막에 2.0 MLE 보다 적은 양의 Au가 증착된 경우에는 Au 4f의 전자 결합에너지가 벌크 Au에 비해서 증가한다. 0.1 MLE의 경우에는 그 결합에너지가 벌크 Au에 비해서 +0.30 eV 이동하였다.

  • PDF

Calibration of Portable Particulate Mattere-Monitoring Device using Web Query and Machine Learning

  • Loh, Byoung Gook;Choi, Gi Heung
    • Safety and Health at Work
    • /
    • 제10권4호
    • /
    • pp.452-460
    • /
    • 2019
  • Background: Monitoring and control of PM2.5 are being recognized as key to address health issues attributed to PM2.5. Availability of low-cost PM2.5 sensors made it possible to introduce a number of portable PM2.5 monitors based on light scattering to the consumer market at an affordable price. Accuracy of light scatteringe-based PM2.5 monitors significantly depends on the method of calibration. Static calibration curve is used as the most popular calibration method for low-cost PM2.5 sensors particularly because of ease of application. Drawback in this approach is, however, the lack of accuracy. Methods: This study discussed the calibration of a low-cost PM2.5-monitoring device (PMD) to improve the accuracy and reliability for practical use. The proposed method is based on construction of the PM2.5 sensor network using Message Queuing Telemetry Transport (MQTT) protocol and web query of reference measurement data available at government-authorized PM monitoring station (GAMS) in the republic of Korea. Four machine learning (ML) algorithms such as support vector machine, k-nearest neighbors, random forest, and extreme gradient boosting were used as regression models to calibrate the PMD measurements of PM2.5. Performance of each ML algorithm was evaluated using stratified K-fold cross-validation, and a linear regression model was used as a reference. Results: Based on the performance of ML algorithms used, regression of the output of the PMD to PM2.5 concentrations data available from the GAMS through web query was effective. The extreme gradient boosting algorithm showed the best performance with a mean coefficient of determination (R2) of 0.78 and standard error of 5.0 ㎍/㎥, corresponding to 8% increase in R2 and 12% decrease in root mean square error in comparison with the linear regression model. Minimum 100 hours of calibration period was found required to calibrate the PMD to its full capacity. Calibration method proposed poses a limitation on the location of the PMD being in the vicinity of the GAMS. As the number of the PMD participating in the sensor network increases, however, calibrated PMDs can be used as reference devices to nearby PMDs that require calibration, forming a calibration chain through MQTT protocol. Conclusions: Calibration of a low-cost PMD, which is based on construction of PM2.5 sensor network using MQTT protocol and web query of reference measurement data available at a GAMS, significantly improves the accuracy and reliability of a PMD, thereby making practical use of the low-cost PMD possible.

갑상선암 수술 전 진단목적의 $^{18}F$-FDG PET/CT Dual Time Point영상에서 SUV값과 방사능 농도 측정법의 유용성 평가 (The Preoperative Diagnosis of Thyroid Cancer in $^{18}F$-FDG PET/CT Dual Time Imaging of SUV and Evaluation of Radioactivity Measurement)

  • 이현국;강현수;양승오;한만석
    • 핵의학기술
    • /
    • 제16권2호
    • /
    • pp.99-105
    • /
    • 2012
  • Purpose : This study is designed to compare two parameters reflecting $^{18}F$-FDG uptake, SUV and radioactivity, for diagnosis of thyroid cancer in dual time $^{18}F$-FDG PET/CT imaging and to find which parameter is more useful to decide whether the tumor is malignant or not. Materials and Methods : We performed retrospective study for 40 patients. All patients are diagnosed as primary thyroid cancer and examined $^{18}F$-FDG PET/CT. First, we got the dispersion of scattering beam of neck and lung apex to set a background and compared each dispersion, mean value, standard deviation of maxSUV and radioactivity. Also, mean maxSUV, ${\Delta}maxSUV$, ${\Delta}maxBq$/ml(%) and radioactivity between groups according to lesion's size based on biopsy are compared with independent-sample t-test. Results : the values that were from maxSUV and radioactivity measurement technique were compensated and calculated to practical values for mean comparison and patients were divided to two groups based on tumor size, Group1 ($size{\leq}1$ cm, n=21), Group2 (size>1 cm, n=19) for accurate comparison. In Group1, maxSUV (semi-quantitative analysis) was increased from $5.64{\pm}5.85$ (1.89~17.84) at first image to $5.90{\pm}5.01$ (1.95~18.22) at second image and radioactivity (Bq/ml) (quantitative analysis) showed similar increase from $5.93{\pm}6.38$ (2.50~16.75) at first image to $6.01{\pm}5.25$ (2.66~16.58) at second image. In Group2, TFmaxSUV was $10.54{\pm}14.36$ (2.54~33.89) in true first image, TSmaxSUV was $9.85{\pm}12.88$ (2.62~26.20) in true second image separately. The maxSUV showed a significant difference in the mean comparison between the two groups (p=0.035) But, mean radioactivity (Bq/ml) was $5.93{\pm}6.38$ (4.81~40.99) in true first image, $6.01{\pm}5.25$ (4.51~36.93) in true second image and didn't show a significant difference statistically (p=0.126) Conclusion : In diagnosis of thyroid tumor, SUV and radioactivity depending on $^{18}F$-FDG uptake showed high similarity with coefficient of determination (R2=0.939) and malignant evaluation results using dual time also showed similar aspect. Radioactivity for evaluation of malignant tumor didn't show better specificity or sensitivity than maxSUV.

  • PDF