• Title/Summary/Keyword: Scattering Center

Search Result 540, Processing Time 0.026 seconds

Average Droplet Size Distribution of a GDI Spray by Simultaneous Fluorescence/Scattering Image Technique (형과/산란광 동시 측정에 의한 GDI 분무의 평균 입경 분포에 관한 연구)

  • Gwak, Su-Min;Ryu, Gyeong-Hun;Choe, Dong-Seok;Kim, Deok-Jul
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.6
    • /
    • pp.868-875
    • /
    • 2001
  • The objective of this study is to investigate the average droplet size distributions of a GDI spray by simultaneous fluorescence/scattering image technique. GDI engine is recently very popular because of high engine efficiency and low emissions. However, the injectors must have good spray characteristics because the fuel is directly injected into the cylinder. The fuel mixtures used in this study were 2% of fluorobenzene, 9% of DEMA(diethyl-methyl-amine) and 89% of hexane by volume. The system for obtaining 2-D fluorescence/scattering images of fuel spray was constituted of a laser sheet, a doubling prism, optical filters, and an ICCD camera. Using the ratio of the fluorescence to the scattering intensities, SMD distributions were obtained. SMD measured by the technique was compared with that obtained by PDA. It was found that average droplet size was bigger at spray center in the early stage of injection and at the outer periphery of the spray in the late stage of injection.

A Study on the Comparision of One-Dimensional Scattering Extraction Algorithms for Radar Target Identification (레이더 표적 구분을 위한 1차원 산란점 추출 기법 알고리즘들의 성능에 관한 비교 연구)

  • Jung, Ho-Ryung;Seo, Dong-Kyu;Kim, Kyung-Tae;Kim, Hyo-Tae
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2003.11a
    • /
    • pp.193-197
    • /
    • 2003
  • Radar target identification can be achieved by using various radar signatures, such as one-dimensional(1-D) range profile, 2-D radar images, and 1-D or 2-D scattering centers on a target. In this letter, five 1-D scattering center extraction methods are discussed - TLS(Total Least Square)-Prony, Fast Root-MUSIC (Multiple Signal Classification), Matrix-Pencil, GEESE(GEneralized Eigenvalues utilizing Signal-subspace Eigenvalues), TLS-ESPRIT(Total Least Squares - Estimation of Signal Parameters via Rotational Invariance Technique), These methods are compared in the context of estimation accuracy as well as a computational efficiency using a noisy data. Finally these methods are applied to the target classification experiment with the measured data in the POSTECH compact range facility.

  • PDF

Development and Performance Evaluation of a Real-time PM Monitor based on Optical Scattering Method (광산란방식을 이용한 미세먼지 실시간 모니터링 장치 개발 및 성능평가)

  • Kang, Doo Soo;Oh, Jung Eun;Lee, Sang Yul;Shin, Hee Joon;Bong, Ha Kyung;Kim, Dae Seong
    • Particle and aerosol research
    • /
    • v.14 no.4
    • /
    • pp.107-119
    • /
    • 2018
  • In this study, we have developed a real-time monitoring device for measuring PM10 and PM2.5 of ambient aerosol particles. The real-time PM monitor (SENTRY Dust Monitor) uses the optical scattering method and has 16 channels in particle size. The laboratory and field tests were carried out to evaluate the developed SENTRY Dust Monitor. Arizona Test Dust particles were used as test particles in the laboratory test and the field test was carried out at the Jongno-gu Observatory in Seoul. The measurements of PM10 and PM2.5 concentrations obtained by SENTTRY Dust Monitor were compared with Grimm Dust Monitor (Model 1.108) and a beta ray gauge. It was shown that the PM10 and PM2.5 concentrations obtained by SENTRY Dust Monitor agree well with that of the reference devices. Based on the results obtained in this study, it could be concluded that the SENTRY Dust Monitor can be used as a PM monitoring device for real-time monitoring of the ambient aerosols.

Scattering Analysis of Radar Target via Evolutionary Adaptive Wavelet Transform (진화적 적응 웨이브릿 변환에 의한 레이다 표적의 산란 해석)

  • Choi, In-Sik
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.10 no.3
    • /
    • pp.148-153
    • /
    • 2007
  • In this paper, the evolutionary adaptive wavelet transform(EAWT) is applied to the scattering analysis of radar target. EAWT algorithm uses evolutionary programming for the time-frequency parameter extraction instead of FFT and the bisection search method used in the conventional adaptive wavelet transform(AWT). Therefore, the EAWT has a better performance than the conventional AWT. In the simulation using wire target(Airbus-like), the comparisons with the conventional AWT are presented to show the superiority of the EAWT algorithm in the analysis of scattering phenomenology. The EAWT can be effectively applied to the radar target recognition.

Characterization of Surface Morphology and Light Scattering of Transparent Conducting ZnO:Al Films as Front Electrode for Silicon Thin Film Solar Cells (실리콘 박막 태양전지 전면 전극용 ZnO : Al 투명전도막의 표면형상 및 산란광 특성)

  • Kim, Young-Jin;Cho, Jun-Sik;Lee, Jeong-Chul;Wang, Jin-Suk;Song, Jin-Soo;Yoon, Kyung-Hoon
    • Korean Journal of Materials Research
    • /
    • v.19 no.5
    • /
    • pp.245-252
    • /
    • 2009
  • Changes in the surface morphology and light scattering of textured Al doped ZnO thin films on glass substrates prepared by rf magnetron sputtering were investigated. As-deposited ZnO:Al films show a high transmittance of above 80% in the visible range and a low electrical resistivity of $4.5{\times}10^{-4}{\Omega}{\cdot}cm$. The surface morphology of textured ZnO:Al films are closely dependent on the deposition parameters of heater temperature, working pressure, and etching time in the etching process. The optimized surface morphology with a crater shape is obtained at a heater temperature of $350^{\circ}C$, working pressure of 0.5 mtorr, and etching time of 45 seconds. The optical properties of light transmittance, haze, and angular distribution function (ADF) are significantly affected by the resulting surface morphologies of textured films. The film surfaces, having uniformly size-distributed craters, represent good light scattering properties of high haze and ADF values. Compared with commercial Asahi U ($SnO_2$:F) substrates, the suitability of textured ZnO:Al films as front electrode material for amorphous silicon thin film solar cells is also estimated with respect to electrical and optical properties.

Waveform distortion of the stimulated Brillouin scattering in a single mode optical fiber with Q-switched Nd:YAG laser

  • Lee, Sang-Hun;Cho, Jin-Hang;Kim, Chil-Min
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2008.02a
    • /
    • pp.335-336
    • /
    • 2008
  • We observe the distortion of the back scattered Stokes pulse and the complementary distortion of the transmitted pulse by the stimulated Brillouin scattering when a Q-switched Nd:YAG laser pulse injected into a single mode optical fiber. We determine the constant required energy for the SBS by comparing their temporal shapes.

  • PDF

Simulation Studies for Noninvasive Optical Measurements of Blood-Scattering Changes in a Skin Model with a Large Blood Vessel

  • Zephaniah, Phillips V;Paik, Seung-ho;Nam, Jungyong;Chang, Ki Young;Jung, Young-Jin;Choi, Youngwoon;Lee, Joonhyung;Kim, Beop Min
    • Current Optics and Photonics
    • /
    • v.3 no.1
    • /
    • pp.46-53
    • /
    • 2019
  • Monte Carlo simulations were performed for a three-dimensional tissue model with and without an embedded large vessel, to understand how varying vessel geometry affects surface light distribution. Vessel radius was varied from 1 to 5 mm, and vessel depth from 2 to 10 mm. A larger difference in surface fluence rate was observed when the vessel's radius increased. For vessel depth, the largest difference was seen at a depth of approximately 4 mm, corresponding to human wrist region. When the vessel was placed at depths greater than 8 mm, very little difference was observed. We also tested the feasibility of using two source-detector pairs, comprising two detectors distinctly spaced from a common source, to noninvasively measure blood-scattering changes in a large vessel. High sensitivity to blood-scattering changes was achieved by placing the near detector closer to the source and moving the far detector away from the source. However, at longer distances, increasing noise levels limited the sensitivity of the two-detector approach. Our results indicate that the approach using two source-detector pairs may have potential for quantitative measurement of scattering changes in the blood while targeting large vessels near the human wrist region.

Design and Development of an Ultralow Optical Loss Mirror Coating for Zerodur Substrate

  • Cho, Hyun-Ju;Lee, Jae-Cheul;Lee, Sang-Hyun
    • Journal of the Optical Society of Korea
    • /
    • v.16 no.1
    • /
    • pp.80-84
    • /
    • 2012
  • A high reflectance mirror, which has very low absorption and scattering loss, was coated onto a crystalline substrate by ion beam sputtering and then annealed at $450^{\circ}C$. We carefully selected the mirror coating material, and designed the high reflectance mirror, in order to avoid UV degradation which comes from the He-Ne plasma. We measured the surface roughness of the Zerodur substrate using phase shift interferometry and atomic force microscopy, and compared it with the TIS scattering of the mirror. The cavity ring-down method was used to measure the absorption of the mirror, and the thin film structure was correlated to its results. We also compared the optical properties of coated mirrors before and after annealing.