• Title/Summary/Keyword: Scattered radiation

Search Result 233, Processing Time 0.024 seconds

Calculation of the Air-Scattering Dose Rate by the Single Scattering Approximation (단일산란근사법(單一散亂近似法)에 의한 공기중(空氣中) 산란방사선량(散亂放射線量)의 계산(計算))

  • Yook, Chong-Chul;Ha, Chung-Woo;Lee, Jai-Ki;Moon, Philip S.
    • Journal of Radiation Protection and Research
    • /
    • v.4 no.1
    • /
    • pp.21-28
    • /
    • 1979
  • A calculation is presented of air-scattered gamma rays using the modified single-scattering approximation. The air-scattered tissue dose rates are calculated for a general purpose taking into account (a) the buildup and exponential attenuation, (b) the energy spectrum at the position of question and (c) the geometrical scattering volume in three dimensions. These calculations have been further modified to render them applicable to a typical field irradiation facility which is surrounded by a shield wall and in which the source is fitted with a beam collimating device. The results of the calculation include the energy spectra, angular distribution and tissue does rates at source-receiver separation distances of from 35m to 300m. The comparison shows that the present method developed may be generally adequate for the gamma-ray air-scattering problems in field irradiation facilities if energy and angular distribution at the shield are unimportant.

  • PDF

A Study on the Comparative Analysis of Images and Doses According to Tube Orientation During Anterior-Posterior Axial Projection Examination of the Skull (머리뼈 전-후 축 방향검사 시 Tube 방향설정에 따른 표면선량과 영상분석에 관한 연구)

  • Jeong, Sung-Hun;Yoo, Je-hyeon;Lim, Cheong-Hwan
    • Journal of radiological science and technology
    • /
    • v.44 no.4
    • /
    • pp.301-306
    • /
    • 2021
  • The skull has peripheral organs such as the crystalline lens and thyroid gland, which are highly radiosensitive, but the examination is performed without considering the uneven dose distribution due to the heel effect at the time of the current Skull Town's examination. However, no studies have been conducted on the exposure dose of surrounding organ tissues due to the difference in image density due to the heel effect and the non-uniformity of the dose. Using the cathode (-) and anode (+) set on the Tube to measure the scattered radiation along the Tube direction as a guide, change 30° and 37° in the cathode direction and 30° and 37° in the anode direction. It was given and investigated 5 times to obtain scattered radiation. image measurements were SNR, PSNR, RMSE, and MAE. Measurement results Measurement results of surrounding organ doses when the Tube direction was 30° and 37° The dose was low when the direction was cathodic in all organs (p<0.000). Both cathodes were higher in the image measurements(p<0.04). Continuous research may be needed for diagnostically valuable imaging and minimization of patient exposure dose.

Impact of Lyman alpha pressure on metal-poor dwarf galaxies

  • Kimm, Taysun;Haehnelt, Martin;Blaizot, Jeremy;Katz, Harley;Michel-Dansac, Leo;Garel, Thibault;Rosdahl, Joakim;Teyssier, Romain
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.43 no.1
    • /
    • pp.36.1-36.1
    • /
    • 2018
  • Understanding the origin of strong galactic outflows and the suppression of star formation in dwarf galaxies is a key problem in galaxy formation. Using a set of radiation-hydrodynamic simulations of an isolated dwarf galaxy, we show that the momentum transferred from resonantly scattered Lyman-alpha(LyA) photons can suppress star formation by a factor of two in metal-poor galaxies by regulating the dynamics of star-forming clouds before the onset of supernova explosions (SNe). This is possible because each LyA photon resonantly scatters and imparts ~10-300 times greater momentum than in the single scattering limit. Consequently, the number of star clusters predicted in the simulations is reduced by a factor of ~5, compared to the model without the early feedback. More importantly, we find that galactic outflows become weaker in the presence of strong LyA radiation feedback, as star formation and associated SNe become less bursty. We also examine a model in which radiation field is arbitrarily enhanced by a factor of up to 10, and reach the same conclusion. The typical mass-loading factors in our metal-poor dwarf system are estimated to be ~5-10 near the mid-plane, while it is reduced to ~1 at larger radii.

  • PDF

Morphological Alteration of Cell Organelles Affected by UV-B Radiation in Rice Leaf Tissues (자외선에 의한 벼 엽 세포 소기관의 형태적 변화)

  • Sung, Jwa-Kyung;Song, Beom-Heon;Kim, Hong-Sig;Lee, Chul-Won;Kim, Tae-Wan
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.37 no.1
    • /
    • pp.31-35
    • /
    • 2004
  • This experiment was performed to observe morphological changes in rice leaf tissue caused by a successive UV-B radiation. Effect of UV-B radiation on the structural alteration of tissue was not visually found, however, Photosynthate containing phosphate was sharply reduced in proportion with an increase of UV-B radiation. Fundamental components of cuticle layer were being degraded after 6 h of UV-B radiation compared to the control. UV-B-induced mesophyll cell appeared altered because of water stress, the shape of chloroplast appeared to be considerably shrunk and chloroplast thylakoid membranes were severely destructed. Primary cell wall of UV-B-stressed tissue was entirely scattered or disappeared, and the secondary cell wall due to lignin synthesis and deposition resulted in being thickened, almost 2-times, compared with the control.

Evaluation of the Space Scattered Dose According to the Position of the Radiation Workers in Mammography Room (유방촬영 시 방사선관계종사자의 위치에 따른 공간선량평가)

  • Lee, Dong-Yeon;Lee, Jin-Soo
    • Journal of radiological science and technology
    • /
    • v.39 no.3
    • /
    • pp.297-303
    • /
    • 2016
  • This study was conducted to evaluate the dose of the space to the controller located within the mammography room conducted a research on ways to the reduction exposure to the radiation workers. Results, the dose of 6.18 mGy/year was measured when there is no difference in the hilar area of the controller position, the dose of 2.35E-11 mGy/year was measured when installing the Shielding door. In addition, when the direction of the X-ray tube anode be heading this direction controller, low average level measured was 0.30 mGy/year. Based on this study, the mammography should be considered when installing the anode and cathod directions. And, by installing the shielding door, it must be able to completely separate shooting space and control room. This is the best way radiation protection method in radiation workers.

Leakage and Scattered Radiation from X-ray Unit in Radiography (영상의학과 엑스선 발생장치의 누설 및 산란선량 측정)

  • Im, In-Chul;Lee, Jae-Seung;Kweon, Dae-Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.3
    • /
    • pp.155-159
    • /
    • 2011
  • The purposed of this study were measured the radiation exposure of patients and workers by generators, and the protection state for radiation facilities. The subject of the study by X-ray generators in university hospitals of capital area, we measured the maximum irradiation condition of 80 kVp, 200 mA, 0.1 second in the control entrance, control room window, entrance of radiography, adjacent site. The leakage dose per week was which the control entrance was 0.11 mR/week, control room window was 0.15 mR/week, entrance of radiography was 0.12 mR/week and adjacent site was 0.06 mR/week with X-ray unit the mean And the leakage mean dose was 0.11 mR/week. Diagnostic X-ray tubes must ensure that the leakage radiation in the maximum leakage dose in week emitted by the tube outside the useful beam does not exceed certain levels provided by standards.

A Comparison of Peripheral Doses Scattered from a Physical Wedge and an Enhanced Dynamic Wedge (금속쐐기와 기능강화동적쐐기의 조사야 주변부 선량 비교)

  • Park, Jong-Min;Kim, Hee-Jung;Min, Je-Soon;Lee, Je-Hee;Park, Charn-Il;Ye, Sung-Joon
    • Progress in Medical Physics
    • /
    • v.18 no.3
    • /
    • pp.107-117
    • /
    • 2007
  • In order to evaluate the radio-protective advantage of an enhanced dynamic wedge (EDW) over a physical wedge (PW), we measured peripheral doses scattered from both types of wedges using a 2D array of ion-chambers. A 2D array of ion-chambers was used for this purpose. In order to confirm the accuracy of the device we first compared measured profiles of open fields with the profiles calculated by our commissioned treatment planning system. Then, we measured peripheral doses for the wedge angles of $15^{\circ},\;30^{\circ},\;45^{\circ},\;and\;60^{\circ}$ at source to surface distances (SSD) of 80 cm and 90 cm. The measured points were located at 0.5 cm depth from 1 cm to 5 cm outside of the field edge. In addition, the measurements were repeated by using thermoluminescence dosimeters (TLD). The peripheral doses of EDW were (1.4% to 11.9%) lower than those of PW (2.5% to 12.4%). At 15 MV energy, the average peripheral doses of both wedges were 2.9% higher than those at 6MV energy. At a small SSD (80 cm vs. 90 cm), peripheral dose differences were more recognizable. The average peripheral doses to the heel direction were 0.9% lower than those to the toe direction. The results from the TLD measurements confirmed these findings with similar tendency. Dynamic wedges can reduce unnecessary scattered doses to normal tissues outside of the field edge in many clinical situations. Such an advantage is more profound in the treatment of steeper wedge angles, and shorter SSD.

  • PDF

Application of a Boundary element Method to the Analysis of ultrasonic Scattering by Flaws (경계요소법을 이용한 결함의 초음파 산란장 해석)

  • Jeong, Hyun-Jo;Kim, Jin-Ho;Park, Moon-Cheol
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.11
    • /
    • pp.2457-2465
    • /
    • 2002
  • Numerical modeling of a nondestructive testing system plays an important role in many aspects of quantitative nondestructive evaluation (QNDE). The ultimate goal of a model is to predict test results for a specific flaw in a material. Thus, in ultrasonic testing, a system model should include the transducer, its radiation pattern, the beam reflection and propagation, and scattering from defects. In this paper attention is focused on the scattering model and the scattered fields by defects are observed by an elastodynamic boundary element method. Flaw types addressed are void-like and crack-like flaws. When transverse ultrasonic waves are obliquely incident on the flaw, the angular distribution of far-field scattered displacements are calculated and presented in the form of A-scan mode. The component signals obtained from each scattering problem are identified and their differences are addressed. The numerical results are also compared with those obtained by high frequency approximate solutions.

A Study on the Measurements of Optical Parameters in Photosensitizer by Light Scattering (농도가 진한 매질에서 광증감제에 의한 광학적 파라미터측정에 관한 연구)

  • Kim, Ki-Jun;Lee, Jou-Joub
    • Journal of the Korean Applied Science and Technology
    • /
    • v.28 no.1
    • /
    • pp.102-108
    • /
    • 2011
  • The study of wave propagation and scattering in biological media has become increasingly important in recent years. The propagation of light within tissues is an important problem that confronts the dosimetry of therapeutic laser delivery and the development of diagnostic spectroscopy. In the clinical application of photodynamic therapy(PDT) and in photobiology, the photon deposition within a tissue determines the spatial distribution of photochemical reactions. Scattered light is measured as a function of the distance (r) between the axis of the incident beam and the detection spot. Consequently, knowledge of the photosensitizer(Chlorophyll-a) function that characterizes a phantom is measured. To obtain the results of scattering coefficients(${\mu}s$) of a turbid material from diffusion described by experimental approach. It was measured the energy fluency of photon radiation at the position of penetration depth. From fluorescence experimental method obtained the analytical expression for the scattered light as the values of $(I/I_o)_{wavelength}$ vs the distance between the center of the incident beam and optical fiber in terms of the condition of "in situ spectroscopy(optically thick)" and real time by fluorometric measurements. The result was compromised with transport of intensities though a random distribution of scatters.

The Image Resolution Compare to Having Lead Plate or Not Lumbar Lateral Projection

  • Kim, Hyun-Soo;Min, Jung-Whan;Dong, Kyung-Rae
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.13 no.4
    • /
    • pp.145-151
    • /
    • 2011
  • The purpose of this study is to know some changes of resolution and image if we remove scattered ray using lead plate when doing lumbar lateral projection. Using 3 DR system(2 FD types, 1 CCD type) equipments and 2 film system equipments, we gain the image whether the phantom of abdomen equivalent sticking resolution chart has lead plate or not, whether we do collimation or not. Also, we use ion chamber, measure radiation exposure rate and change to entrance surface dose from it. we gain that images in the greatest condition of taking in clinic. 5 people in this group decoded resolution with our eyes, measured thickness of images and compared them from each equiments. Resolution has difference to size of collimation in DR FD type. Also there is no difference the original image with the new image which we abbreviated mAs. In DR CCD type, resolution didn't have difference whether lead plate is or not and whether we do collimation or not. In film type, existing or nonexisting of lead plate didn't influence on resolution. Lead plate makes the quality of image higher due to reducing scattered ray, it doesn't influence on resolution.

  • PDF