• 제목/요약/키워드: Scattered X-ray

검색결과 149건 처리시간 0.022초

A Study of the Relationship between Absorbed Energy and DR Pixel Values Using SPEC-78

  • Kim, Do-Il;Lee, Hyoung-Koo;Kim, Sung-Hyun;Ho, Dong-Su;Choe, Bo-young;Suh, Tae-Suk
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2003년도 제27회 추계학술대회
    • /
    • pp.69-69
    • /
    • 2003
  • Flat panel based digital radiography (DR) systems have recently become useful and important in the field of diagnostic radiology. For DRs with amorphous silicon photosensors, CsI(TI) is normally used as the scintillator, which produces visible light corresponding to the absorbed energy. The visible light photons are converted into an electric signal in the amorphous silicon photodiode. In order to produce good quality images, we need to understand the detailed behavior of DR detectors in radiation. We, therefore, investigated the relationship between DR outputs and X -ray in terms of absorbed energy, using the SPEC-78, X-ray energy spectrum model. We calculated the total filtration of X-ray equipment measuring air exposure and this value was used in the calculation of absorbed energy. The relationship between DR output and the absorbed energy of the X-ray was obtained by matching the absorbed energy with pixel values of real images under various conditions. It was found that the relationship between these two values was almost linear. The results were verified using phantoms made of water and aluminium. The pixel value of the phantom image was estimated and compared with previous results under various conditions. The estimated pixel value coincided with the results, although the effect of scattered photons introduced some errors.

  • PDF

디지털 방사선 영상에서 그리드 왜곡의 포화 특성에 관한 연구와 적응 필터링에 기초한 제거 (Analysis on the Saturation of Grid Artifact and its Reduction in Digital Radiography Images Based on the Adaptive Filtering)

  • 김동식;이상균
    • 대한전자공학회논문지SP
    • /
    • 제48권4호
    • /
    • pp.1-11
    • /
    • 2011
  • 산란선을 흡수하여 보다 선명한 x선 영상을 얻기 위하여 산란방지 그리드를 사용하여 투사영상을 얻는데, 이때 그리드 패턴으로 인한 왜곡이 발생하며, 디지털 필터를 사용하여 제거할 필요가 있다. 그런데 x선에 대하여 과하게 노출되어 영상디텍터에서 포화된 영상이 형성되는 경우에는 그리드 왜곡의 제거가 잘되지 않는다. 본 논문에서는, 보다 효율적으로 그리드 왜곡을 제거하기 위하여 x선 영상 형성에서 노출량에 따른 특성을 포화 현상까지 포함하여 분석하였다. 포화가 되기 시작하면 그리드 왜곡 성분의 최대 크기가 오히려 줄어들고 대역폭은 넓어지는 특성을 관찰할 수 있었다. 또한 왜곡 성분의 중요신호대역폭 (significant-signal bandwidth)을 측정하여 필터의 대역폭을 결정하여 그리드 왜곡을 효율적으로 줄일 수 있는 적응 필터링 알고리듬을 제안하였다. 실제 x선 디지털 영상에 대한 실험을 통하여 제안한 알고리듬이 효율적으로 그리드 왜곡을 제거할 수 있음을 확인하였다.

portable 흉부촬영시 공간산란선량에 관한 연구 (A Study on the Scattered Dose in Portable Chest Radiography)

  • 안봉선;이환형
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제23권2호
    • /
    • pp.63-67
    • /
    • 2000
  • The purpose of this study is to survey the present status of portable radiography and the result of free space scattered dose rate when taking a radiography at the general hospital or the university hospital in Taejon city. The results were as follows; 1. The number of cases using portable radiography for three years increased to averages 16.2%, 7.7% per year from January 1st in 1996 to December 31st in 1998. 2. The average of distance of adjacent patients was 219.1 cm at the ward. 3. For portable chest radiography, the free space scattered dose rate was 10.5 mSv/hr at 50 cm distance, 1.8 mSv/hr at 100 cm distance, and 0.2 mSv/hr at 200 cm distance. Therefore, in case of portable chest radiography at the ward, the average of distance of adjacent patients is 219.1 cm, so it does not have influence on the adjacent patients. But during the portable radiography, a guardian who is close to the patient, doctor, nurse and radiologic technologists has to set up the shield to prevent from the unnecessary radiation or the distance should be as great as possible from the mobile X-ray equipment.

  • PDF

열처리에 따른 Cu 전해도금막의 미세구조 및 물리적성질 변화 (The Microstructure and physical properties of electroplated Cu films)

  • 권덕렬;박현아;김충모;이종무
    • 한국진공학회지
    • /
    • 제13권2호
    • /
    • pp.72-78
    • /
    • 2004
  • TaN막 위에 magnetron sputtering으로 증착 시킨 Cu seed 막을 Cu 전해도금을 하기에 앞서 ECR plasma 장치로 전처리 세정하였다. 이때 Cu 막을 200∼$500^{\circ}C$로 변화시키면서 알곤 또는 질소 분위기에서 RTA(rapid themal annealing) 방법으로 열처리하였다. Cu seed 막 위에 전해도금법으로 형성한 Cu 막을 열처리했을 때 미세구조와 물리적 특성변화를 XRD(x-ray diffraction), EBSD(electron back-scattered diffraction), AFM(atomic force microscopy) 분석을 이용하여 조사하였다. $400^{\circ}C$보다 높은 온도에서 재결정이 일어났으며, 열처리 온도를 증가함에 따라 Cu막의 비저항이 감소하고 (111) 우선배향성이 증가하는 경향을 나타냈다. 최소의 비저항과 부드러운 표면 및 (111) 배향성이 뛰어난 Cu막을 얻기 위한 최적의 열처리 조건은 $400^{\circ}C$의 질소분위기에서 120초간 RTA처리를 하는 것으로 판단된다. 이 조건하에서 전해도금된 Cu막의 비저항(resistivity)과 표면 거칠기(surface roughness)는 각각 1.98$\mu$O-cm 및 17.77nm였다.

FUV spectral images of the Orion-Eridanus Superbubble region

  • 조영수;민경욱;선광일;;한원용
    • 천문학회보
    • /
    • 제36권1호
    • /
    • pp.88.2-88.2
    • /
    • 2011
  • The far-ultraviolet (FUV) continuum and spectral images of C IV and H2 emission lines for the region of Orion-Eridanus Superbubble (OES) are hereby presented and compared with the maps obtained in other wavelengths. While the region shows complex structures, consisting of hot gases and cold dust, a close examination reveals that the FUV emission in this region can be understood reasonably as the result of their interactions. We confirm the origin of most diffuse FUV continuum to be starlight scattered by dust, but we also find that the ionized gas also contributes 50-70% of the total FUV intensity in the regions of H_alpha arcs. We note the bright diffuse FUV continuum in the eastern part of the northern dust-rich region, and attribute it to the bright early-type stars more abundant in this region than in the west as the amount of dust itself does not seem to be much different across 'arc A' that separates the two regions. In addition, two P Cygni-type stars are identified in this eastern region and their peculiar spectral profiles around the C IV emission line are anifested in the scattered diffuse spectrum. Besides this, the C IV emission is generally enhanced at the boundaries of the hot X-ray cavities where thin dust regions are located, confirming the thermal interface nature of the origin of this cooling emission line. The morphology of the H2 emission shows a general correlation with dust extinction features but its intensity peaks are rather located in thin dust areas, off the peak dust regions. Furthermore, H2 emission is seen to be weak in the arc A region though the arc passes through the center of the dust-rich area. Hence, the H2 emission and dust features, together with those of X-ray and ion lines emissions, show stratified structure of arc A quite well, again confirming its thermal interface nature.

  • PDF

흉부 및 복부 CT 검사 시 안구와 갑상선의 방사선 피폭선량 저감 (Reduction of Radiation Exposure Dose of Eyeball and Thyroid for Chest and Abdomen CT Scan)

  • 이준석;천권수
    • 한국방사선학회논문지
    • /
    • 제13권2호
    • /
    • pp.147-151
    • /
    • 2019
  • 흉부 및 복부 CT 검사 시 산란선에 의한 안구와 갑상선의 방사선 피폭선량을 측정하고, 피폭선량의 감소를 위해 차폐체를 사용함으로써 방사선 피폭 정도를 조사하였다. 임상에서 사용되는 흉부 및 복부 CT 검사 프로토콜을 적용하여 안구와 갑상선의 차폐체 사용 전과 후의 선량을 측정하여 비교하였다. 안구와 갑상선의 표면선량은 OSLD를 사용하여 측정하였다. 산란선을 차폐하기 위해 바륨, 텅스텐 시트와 고글과 목 차폐체를 사용하였다. 흉부 CT 스캔 시 차폐를 하지 않고 스캔한 안구는 3.01 mSv, 갑상선은 6.21 mSv로 측정 되었고 복부 CT 스캔 시 차폐를 하지 않고 스캔한 안구는 0.55 mSv, 갑상선은 3.22 mSv를 나타내었다. 바륨과 텅스텐 시트는 흉부 CT 검사 시 안구와 갑상선의 차폐율이 11~13%이었고, 복부 CT 검사 시에는 34~49%까지 방사선 피폭의 저감 효과가 있었다. 흉부 및 복부 CT 검사 시 방사선 피폭 정도가 상당하기 때문에 검사가 반복, 지속적으로 이루어진다면 방사선 피폭으로 인해 갑상선 암, 백내장 등 방사선 위해가 발생할 가능성이 있어 검사 시 차폐체를 사용하는 것이 요구된다.

구내 촬영시 방사선사의 안면부 피폭선량 측정 (Facial Exposure Dose Assessment During Intraoral Radiography by Radiological Technologists)

  • 유환;양한준
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제37권3호
    • /
    • pp.195-201
    • /
    • 2014
  • 본 연구에서는 구내 촬영시 방사선작업종사자와 X선관 사이 거리의 증가에 따라 방사선작업종사자의 안면부 피폭선량 감소의 변화를 측정하고자 하였다. 우선 인체조직과 유사한 안면부 Phantom을 제작하였다. 구내 촬영 장치를 이용하여 촬영조건을 성인 상악 대구치부 노출조건 (60kVp, 10mA. 50msec)과 소아 상악 대구치부 노출조건 (60kVp, 10mA, 20msec)으로 설정 하고 방사선작업종사의 안면부의 위치에 Chamber를 고정시켰다. X선 관구와 Phantom을 Chamber로 부터 10cm, 15cm, 20cm, 25cm, 30cm, 35cm, 40cm 위치시킨 후 각 검사조건으로 Phantom을 20회 조사한 후 평균 산란선량을 측정 하였다. 연구 결과 성인 조건으로 조사한 후 감소율은 10cm에서 조사한 산란선량을 기준으로 하였을 때 40cm 에서는 감소율이 7.43%로 약 92.6%가 감소가 되었다. 또한 소아 조건으로 조사한 후 감소율은 10 cm에서 조사한 산란선량을 기준으로 하였을 때 40 cm 에서는 감소율이 2.58 %로 약 97.6%가 감소가 되었다. 결론적으로 치과 방사선 검사 시 방사선 피폭에 대한 방호가 필요할 것으로 사료된다.

산란선 제거를 위한 신개념 간접 평판형 검출기의 임상적용을 위한 최적 구조 : 입사 X선 각도에 따른 성능평가 (An Optimal Structure of a Novel Flat Panel Detector to Reduce Scatter Radiation for Clinical Usage: Performance Evaluation with Various Angle of Incident X-ray)

  • 윤용수
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제40권4호
    • /
    • pp.533-542
    • /
    • 2017
  • 진단용 X선 영상에서 산란선은 화질을 열화시키는 주요한 원인이다. X선 장치는 필름/스크린을 사용한 아날로그 시스템부터 Imaging plate (IP) 및 평판 검출기(Flat panel detector; FPD)를 사용한 디지털 시스템으로 바뀌어 가고 있다. 그러나 산란 X선 제거를 위한 Grid는 아날로그 시대에 사용됐던 구조부터 큰 변화가 없다. 본 논문에서는 선행연구에서 고안된 산란선 제거율을 향상시키기 위한 간접변환형 평판검출기의 새로운 구조를 다양한 입사 X선을 사용하는 임상현장에서의 활용 가능성을 검토했다. 일반적으로 FPD는 3개의 층으로 구성되어 있다. 신호를 검출하는 화소와 화소 사이에는 전압을 거는 voltage line이나 데이터를 전달하는 data line과 같은 X선 불감영역이 존재한다. 선행연구에서는 이 불감영역에 정확히 맞추어 방사선 불 투과성의 납을 그물 모양으로 substrate layer에 삽입함으로서 검출기 자체가 산란선 제거 효과가 있도록 설계하였다. 새로운 구조의 임상 유용성을 평가하기 위해, 삽입된 그물 모양의 납을 입사 X선에 대해 가로, 세로성분으로 나누어 각각의 성능을 확인하였으며, 동시에 납의 높이를 변화시켜 납 높이가 성능에 미치는 영향을 영상 대조도와 grid 노출 인자를 통해 검토했다. 검출기면에 대해 대각선으로 입사한 X선($0^{\circ}$, $15^{\circ}$, $30^{\circ}$)에 대해서, 입사 X선에 대해 평행한 가로성분이 세로 성분에 비해 높은 영상 대조도와 낮은 그리드 노출 인자를 나타냈으며, 세로성분의 납 높이가 높을수록 본 연구에서 고안한 검출기에 악영향을 미치는 것을 확인했다. 그러므로 본 연구에서 고안한 새로운 FPD 시스템은 FPD의 구조를 방사선검사 조건과 목적에 맞추어 최적화함으로써 임상 의료현장에서의 사용 가능성이 확인되었다.

EUV AND SOFT X-RAY EMISSION IN CLUSTERS OF GALAXIES

  • BOWYER STUART
    • 천문학회지
    • /
    • 제37권5호
    • /
    • pp.295-297
    • /
    • 2004
  • Observations with EUVE, ROSAT, and BeepoSAX have shown that some clusters of galaxies produce intense EUV emission. These findings have produced considerable interest; over 100 papers have been published on this topic in the refereed literature. A notable suggestion as to the source of this radiation is that it is a 'warm' (106 K) intracluster medium which, if present, would constitute the major baryonic component of the universe. A more recent variation of this theme is that this material is 'warm-hot' intergalactic material condensing onto clusters. Alternatively, inverse Compton scattering of low energy cosmic rays against cosmic microwave background photons has been proposed as the source of this emission. Various origins of these particles have been posited, including an old (${\~}$Giga year) population of cluster cosmic rays; particles associated with relativistic jets in the cluster; and cascading particles produced by shocks from sub-cluster merging. The observational situation has been quite uncertain with many reports of detections which have been subsequently contradicted by analyses carried out by other groups. Evidence supporting a thermal and a non-thermal origin has been reported. The existing EUV, FUV, and optical data will be briefly reviewed and clarified. Direct observational evidence from a number of different satellites now rules out a thermal origin for this radiation. A new examination of subtle details of the EUV data suggests a new source mechanism: inverse Compton scattered emission from secondary electrons in the cluster. This suggestion will be discussed in the context of the data.