• Title/Summary/Keyword: Scatter fraction

Search Result 35, Processing Time 0.029 seconds

Microstructural Evolution of Ultrafine Grained AA1050/AA6061 Complex Aluminum Alloy Sheet with ARB Process (ARB공정에 따른 초미세립 AA1050/AA6061 복합알루미늄 합금 판재의 미세조직 발달)

  • Lee, Seong-Hee
    • Korean Journal of Materials Research
    • /
    • v.23 no.1
    • /
    • pp.41-46
    • /
    • 2013
  • The microstructural evolution of AA1050/AA6061 complex aluminum alloy, which is fabricated using an accumulative roll-bonding (ARB) process, with the proceeding of ARB, was investigated by electron back scatter diffraction (EBSD) analysis. The specimen after one cycle exhibited a deformed structure in which the grains were elongated to the rolling direction for all regions in the thickness direction. With the proceeding of the ARB, the grain became finer; the average grain size of the as received material was $45{\mu}m$; however, it became $6.3{\mu}m$ after one cycle, $1.5{\mu}m$ after three cycles, and $0.95{\mu}m$ after five cycles. The deviation of the grain size distribution of the ARB processed specimens decreased with increasing number of ARB cycles. The volume fraction of the high angle grain boundary also increased with the number of ARB cycles; it was 43.7% after one cycle, 62.7% after three cycles, and 65.6% after five cycles. On the other hand, the texture development was different depending on the regions and the materials. A shear texture component {001}<110> mainly developed in the surface region, while the rolling texture components {011}<211> and {112}<111> developed in the other regions. The difference of the texture between AA1050 and AA6061 was most obvious in the surface region; {001}<110> component mainly developed in AA1050 and {111}<110> component in AA6061.

Performance Characteristics of MicroPET R4 Scanner for Small Animal Imaging (소동물 영상을 위한 MicroPET R4스캐너의 특성평가)

  • Lee, Byeong-Il;Lee, Jae-Sung;Kim, Jin-Su;Lee, Dong-Soo;Choi, Chang-Un;Lim, Sang-Moo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.1
    • /
    • pp.49-56
    • /
    • 2005
  • Purpose: Dedicated animal PET is useful equipment for the study of new PET tracer. recently, microPET R4 was installed in the Korea institute of radiology and medical science. In this study, we measured the characteristics of scanner. Materials and methods: Resolution was measured using a line source (F-18:65 ${\mu}Ci$, inner diameter: 0.5 mm). The line source was put in the axial direction and was moved from the center of field of view to outside with 1 mm interval. PET images were reconstructed using a filtered back-protection and ordered subset expectation maximization. line source (16.5 ${\mu}Ci$, 78 mm) was put on the tenter of axial direction to measure the sensitivity when the deadtime was under 1%. Images were acquired during 4 minutes respectively from center to 39 mm outward. Delayed count was subtracted from total count and then decay was corrected for the calculation of sensitivity. Noise equivalent count ratio and scatter fraction were calculated using cylindrical phantom. Results: Spatial resolution of reconstructed image using filtered back-projection was 1.86 mm(radial), 1.95 mm(tangential), 1.95 mm(axial) in the tenter of field of view, and 2.54 mm, 2.8 mm, 1.61 mm in 2 cm away from the center respectively. Sensitivity was 2.36% at the center of transaxial field of view. Scatter fraction was 20%. Maximal noise equivalent count ratio was 66.4 kcps at 242 kBq/mL. Small animal images were acquired for confirmation of performance. Conclusion: Performance characteristics of microPET R4 were similar with reported value. So this will be a useful tool for small animal imaging.

Quantitative Ultrasound Radiofrequency Data Analysis for the Assessment of Hepatic Steatosis in Nonalcoholic Fatty Liver Disease Using Magnetic Resonance Imaging Proton Density Fat Fraction as the Reference Standard

  • Sun Kyung Jeon;Jeong Min Lee;Ijin Joo;Sae-Jin Park
    • Korean Journal of Radiology
    • /
    • v.22 no.7
    • /
    • pp.1077-1086
    • /
    • 2021
  • Objective: To investigate the diagnostic performance of quantitative ultrasound (US) parameters for the assessment of hepatic steatosis in patients with nonalcoholic fatty liver disease (NAFLD) using magnetic resonance imaging proton density fat fraction (MRI-PDFF) as the reference standard. Materials and Methods: In this single-center prospective study, 120 patients with clinically suspected NAFLD were enrolled between March 2019 and January 2020. The participants underwent US examination for radiofrequency (RF) data acquisition and chemical shift-encoded liver MRI for PDFF measurement. Using the RF data analysis, the attenuation coefficient (AC) based on tissue attenuation imaging (TAI) (AC-TAI) and scatter-distribution coefficient (SC) based on tissue scatter-distribution imaging (TSI) (SC-TSI) were measured. The correlations between the quantitative US parameters (AC and SC) and MRI-PDFF were evaluated using Pearson correlation coefficients. The diagnostic performance of AC-TAI and SC-TSI for detecting hepatic fat contents of ≥ 5% (MRI-PDFF ≥ 5%) and ≥ 10% (MRI-PDFF ≥ 10%) were assessed using receiver operating characteristic (ROC) analysis. The significant clinical or imaging factors associated with AC and SC were analyzed using linear regression analysis. Results: The participants were classified based on MRI-PDFF: < 5% (n = 38), 5-10% (n = 23), and ≥ 10% (n = 59). AC-TAI and SC-TSI were significantly correlated with MRI-PDFF (r = 0.659 and 0.727, p < 0.001 for both). For detecting hepatic fat contents of ≥ 5% and ≥ 10%, the areas under the ROC curves of AC-TAI were 0.861 (95% confidence interval [CI]: 0.786-0.918) and 0.835 (95% CI: 0.757-0.897), and those of SC-TSI were 0.964 (95% CI: 0.913-0.989) and 0.935 (95% CI: 0.875-0.972), respectively. Multivariable linear regression analysis showed that MRI-PDFF was an independent determinant of AC-TAI and SC-TSI. Conclusion: AC-TAI and SC-TSI derived from quantitative US RF data analysis yielded a good correlation with MRI-PDFF and provided good performance for detecting hepatic steatosis and assessing its severity in NAFLD.

Texture Evolution during Primary Recrystallization and Effect of Number of Cold Rolling Passes, Heating Rate, and Si Contents in Grain-Oriented Electrical Steel (방향성 전기강판에서 1차 재결정시 Si 함량과 냉간압연 횟수, 승온 속도에 따른 집합조직 발달)

  • Jeon, Soeng-Ho;Park, No Jin
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.31 no.6
    • /
    • pp.269-274
    • /
    • 2018
  • Grain-oriented electrical steel sheets are mainly used as core materials for transformers and motors. They should have excellent magnetic properties such as low core loss, high magnetic flux density and high permeability. In order to improve the magnetic properties of the electrical steel sheet, it is important to form Goss oriented grains with a very strong {110}<001> orientation. Recently, efforts have been made to develop Goss grains by controlling processes such as hot rolling, cold rolling, and primary and secondary recrystallization. In this study, the sheets containing 3.2 and 3.4wt.% Si were used, which were rolled with 1 and 10 passes with total thickness reduction of 89%. Heating was carried out for primary recrystallization with different heating rates of $25^{\circ}C/s$ and $24^{\circ}C/min$ until $720^{\circ}C$. The behavior of Goss-, {411}<148>-, and {111}<112>-oriented grains were analyzed using X-ray diffraction(XRD) and electron back-scatter diffraction(EBSD) analysis. The area fraction of Goss-oriented grains increased with the number of rolling passes during cold rolling; however, after the primary recrystallization, the area fraction of the Goss grains was higher and exact Goss grains were found in the specimens subjected to rapid heating after one rolling pass.

Evaluation of Sperm Sex-Sorting Method using Flow Cytometry in Hanwoo (Korean Native Cattle)

  • Yoo, Han-Jun;Lee, Kyung-Jin;Lee, Yong-Seung;Lee, Chang-Woo;Park, Joung-Jun;Cheong, Hee-Tae;Yang, Boo-Keun;Park, Choon-Keun
    • Journal of Embryo Transfer
    • /
    • v.27 no.1
    • /
    • pp.37-43
    • /
    • 2012
  • This study evaluated a method of sorting X and Y chromosomes based on size using the forward angle light scatter related refractive index (FSC) of a flow cytometer. Hanwoo bulls sperm were separated to X and Y chromosomes by the parameters of FSC or Hoechst 33342 intensity. As a result, using monitor program linked flow cytometry during sorting processing, the purities were $97{\pm}0.57$ or $96{\pm}0.67%$ for the X-fraction and $96{\pm}0.33$ or $97{\pm}1.33%$ for the Y-fraction in the two sperm sorting methods. There were no differences in the X and Y ratios (X and Y %) between the sperm sorting methods based on FSC or DNA content. The proportions of female and male embryos used for in vitro fertilization and development were $66.03{\pm}3.31$ or $69.37{\pm}1.41%$, and $70.56{\pm}2.42$ or $56.11{\pm}3.09%$ when sperm were processed using the sex sorting method by FSC or Hoechst 33342. In conclusion, further study is needed to determine the optimum procedure and improve the nozzle to enhancing sorting accuracy or efficiency. Also, the findings of this study do not negate the possibility that the difference method of sperm sorting cannot use a UV laser beam.

Analysis of Mean Deviation in Sliding-wear-rate of Carbon Steel with Various Pearlite Volume Fractions (탄소강의 펄라이트 분율에 따른 미끄럼 마멸속도 편차 분석)

  • Kim, M.G.;Gwon, H.;Hur, H.L.;Kim, Y.-S.
    • Transactions of Materials Processing
    • /
    • v.24 no.3
    • /
    • pp.205-211
    • /
    • 2015
  • The current investigation was performed to study sliding-wear-rate deviation (wear-rate data scatter) in carbon steels with various microstructures. Pure iron, 0.2 wt. % C steel, 0.45 wt. % C steel, and bearing steel (AISI52100) were used for the investigation. These steels possess different microstructures. Microstructures of the pure iron, two carbon steel and the bearing steel were full ferrite, ferrite + pearlite and full pearlite, respectively. Depending on the carbon content, the carbon steel had different pearlite-volume fractions. Dry sliding wear tests of the steel were conducted using a ball-on-disk wear tester at a sliding speed of 0.1 m/s using a bearing ball (AISI52100) as a counterpart. Applied load and sliding distance were 100 N and 300 m, respectively. More than three (up to twelve) tests were conducted for each steel under the same conditions, and the mean deviations in the wear rate of the steel (microstructure) were compared. The wear-rate deviation in the steel with ferrite + pearlite microstructure was higher than that with ferrite microstructure, and the deviation decreased with the increase of pearlite volume fraction. The pure iron and the bearing steel specimens showed much less deviation. The high deviation observed from the ferrite + pearlite steel was attributed to irregular subsurface-crack nucleation and growth at the interface between the two micro constituents (ferrite and pearlite) during the wear test.

Verification of Quantitative Evaluation Method for Ferritic Weld Metal Microstructure (철강 용착금속 미세조직의 정량화 기법 검증)

  • Kim Ka-Hee;Kim Hee-Jin;Ryoo Hoi-Soo
    • Journal of Welding and Joining
    • /
    • v.23 no.4
    • /
    • pp.27-33
    • /
    • 2005
  • Quantitative evaluation was performed on the microstructure of flux-cored arc(FCA) weld metal using a method blown as IIW scheme. It was mainly intended to figure out any practical difficulties in applying this method and also to provide the consumable makers with basic guide line in developing FCA welding consumables far better properties. Assessment of the experimental results showed IIW scheme was quite reliable in the low heat input range where the acicular ferrite was a major constituent. However, in the high heat input range, some scatter was noticed as the other phases like grain boundary ferrite and Widmansttaten ferrite become dominant. It implies that the accuracy of IIW scheme depends on the faction of microstructural constituents and it become worse as the fraction of latter two phases increases. This tendency was discussed in terms of the characteristics of those two phases. In addition, base line microstructure of rutile type FCA weld metal was addressed for developing new FCA welding consumables intended for higher heat input welding.

Standard Performance Measurements of GE $Advance^{TM}$ Positron Emission Tomography (GE $Advance^{TM}$ 양전자방출단층촬영기의 표준 성능평가)

  • Jeong, Ha-Kyu;Kim, Hee-Joung;Son, Hye-Kyung;Bong, Jung-Kyun;Jung, Hai-Jo;Jeon, Tae-Joo;Kim, Jae-Sam;Lee, Jong-Doo;Yoo, Hyung-Sik
    • The Korean Journal of Nuclear Medicine
    • /
    • v.35 no.2
    • /
    • pp.100-112
    • /
    • 2001
  • Purpose: The purpose of this study was to establish optimal imaging acquisition conditions for the GE $Advance^{TM}$ PET imaging system by performing the acceptance tests designed by National Electrical Manufacturers Association (NEMA) protocol and General Electric Medical Systems (GEMS) test procedures. Materials and Methods: Performance tests were carried out with $^{18}FDG$ radioactivity source and phantoms by using a standard acquisition mode. Transaxial resolution and scatter traction tests were performed with a line source and axial resolution with a point source, respectively. A cylindrical phantom made of polymethylmethacrylate (PMMA) was used to measure sensitivity, count rate losses and randoms, uniformity correction, and attenuation inserts were added to measure remaining tests. The test results were acquired in a diagnostic acquisition mode and analyzed mainly on high sensitivity mode. Results: Transaxial resolution and axial resolution were measured as average of 4.65 mm and 3.98 mm at 0 cm, and 6.02 mm and 6.71 mm at 20 cm on high sensitivity mode, respectively. Average scatter fraction was 9.87%, and sensitivity was $225.8kcps/{\mu}Ci/cc$ of trues. Activity at 50% deadtime was $4.6{\mu}Ci/cc$, and the error of count rate correction at that activity was from 1.49% to 3.83%. Average nonuniformity for total slice w3s 8.37%. The accuracy of scatter correction was -0.95%. The accuracies of attenuation correction were 5.68% for air, 0.04% for water and -6.51% for polytetrafluoroethylene (PTFE). Conclusion: The results satisfied most acceptance criteria, indicating that the GE $Advance^{TM}$ PET system can be optimally used for clinical applications.

  • PDF

The first UV fundamental plane and evidence of star formation in early-type galaxies

  • Jeong, Hyun-Jin;Yi, Suk-Young;Bureau, Martin;Davies, Roger L.
    • Bulletin of the Korean Space Science Society
    • /
    • 2009.10a
    • /
    • pp.36.2-36.2
    • /
    • 2009
  • We present GALEX (Galaxy Evolution Explorer) far (FUV) and near (NUV) ultraviolet imaging of 34 nearby early-type galaxies from the SAURON representative sample of 48 E/S0 galaxies, all of which have ground-based optical imaging from the MDM Observatory. The surface brightness profiles of nine galaxies (~26 per cent) show regions with blue UV-optical colours suggesting recent star formation. Five of these (~15 per cent) show blue integrated UV-optical colours that set them aside in the NUV integrated colour-magnitude relation. These are objects with either exceptionally intense and localised NUV fluxes or blue UV-optical colours throughout. They also have other properties confirming they have had recent star formation, in particular Hbeta absorption higher than expected for a quiescent population and a higher CO detection rate. This suggests that residual star formation is more common in early-type galaxies than we are used to believe. NUV-blue galaxies are generally drawn from the lower stellar velocity dispersion (sigma_e <200 km/s) and thus lower dynamical mass part of the sample. We have also constructed the first UV Fundamental Planes and show that NUV blue galaxies bias the slopes and increase the scatters. If they are eliminated the fits get closer to expectations from the virial theorem. Although our analysis is based on a limited sample, it seems that a dominant fraction of the tilt and scatter of the UV Fundamental Planes is due to the presence of young stars in preferentially low-mass early-type galaxies.

  • PDF

Comparison of Image Uniformity with Photon Counting and Conventional Scintillation Single-Photon Emission Computed Tomography System: A Monte Carlo Simulation Study

  • Kim, Ho Chul;Kim, Hee-Joung;Kim, Kyuseok;Lee, Min-Hee;Lee, Youngjin
    • Nuclear Engineering and Technology
    • /
    • v.49 no.4
    • /
    • pp.776-780
    • /
    • 2017
  • To avoid imaging artifacts and interpretation mistakes, an improvement of the uniformity in gamma camera systems is a very important point. We can expect excellent uniformity using cadmium zinc telluride (CZT) photon counting detector (PCD) because of the direct conversion of the gamma rays energy into electrons. In addition, the uniformity performance such as integral uniformity (IU), differential uniformity (DU), scatter fraction (SF), and contrast-to-noise ratio (CNR) varies according to the energy window setting. In this study, we compared a PCD and conventional scintillation detector with respect to the energy windows (5%, 10%, 15%, and 20%) using a $^{99m}Tc$ gamma source with a Geant4 Application for Tomography Emission simulation tool. The gamma camera systems used in this work are a CZT PCD and NaI(Tl) conventional scintillation detector with a 1-mm thickness. According to the results, although the IU and DU results were improved with the energy window, the SF and CNR results deteriorated with the energy window. In particular, the uniformity for the PCD was higher than that of the conventional scintillation detector in all cases. In conclusion, our results demonstrated that the uniformity of the CZT PCD was higher than that of the conventional scintillation detector.