• Title/Summary/Keyword: Scatter Map

Search Result 18, Processing Time 0.027 seconds

Effect of filters and reconstruction method on Cu-64 PET image

  • Lee, Seonhwa;Kim, Jung min;Kim, Jung Young;Kim, Jin Su
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.3 no.2
    • /
    • pp.65-71
    • /
    • 2017
  • To assess the effects of filter and reconstruction of Cu-64 PET data on Siemens scanner, the various reconstruction algorithm with various filters were assessed in terms of spatial resolution, non-uniformity (NU), recovery coefficient (RC), and spillover ratio (SOR). Image reconstruction was performed using filtered backprojection (FBP), 2D ordered subset expectation maximization (OSEM), 3D reprojection algorithm (3DRP), and maximum a posteriori algorithms (MAP). For the FBP reconstruction, ramp, butterworth, hamming, hanning, or parzen filters were used. Attenuation or scatter correction were performed to assess the effect of attenuation and scatter correction. Regarding spatial resolution, highest achievable volumetric resolution was $3.08mm^3$ at the center of FOV when MAP (${\beta}=0.1$) reconstruction method was used. SOR was below 4% for FBP when ramp, Hamming, Hanning, or Shepp-logan filter were used. The lowest NU (highest uniform) after attenuation & scatter correction was 5.39% when FBP (parzen filter) was used. Regarding RC, 0.9 < RC < 1.1 was obtained when OSEM (iteration: 10) was used when attenuation and scatter correction were applied. In this study, image quality of Cu-64 on Siemens Inveon PET was investigated. This data will helpful for the quantification of Cu-64 PET data.

Accuracy Evaluation of ASTER DEM, SRTM DEM using Digital Topographic Map (1:5000 수치지형도를 이용한 ASTER DEM과 SRTM DEM의 구축정확도 평가)

  • Kang, Kyung-Ho;Kim, Chang-Jae;Sohn, Hong-Gyoo;Lee, Won-Hee
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.28 no.1
    • /
    • pp.169-178
    • /
    • 2010
  • The main purpose of this study is to evaluate the feasibility and the accuracy of ASTER DEM and SRTM DEM covering 99% of the earth surface using large-scale Digital Topographic Map in mountainous area(Sokcho), mixed area(Jinan, mountainous area and even land area) and even land area(Anyang). We made DEM using contour lines of 1:5,000 Digital Topographic Map of study area and also acquired ASTER DEM and SRTM DEM of their corresponding area. In order to verify accuracy of DEM, this study compared ASTER DEM and SRTM DEM data using 15m resolution DEM generated from contour lines of Digital Topographic Map as basis for each study area. To evaluate the accuracy of ASTER and SRTM DEM data, statistical such as RMSE and correlation were calculated and histogram and scatter plot were drawn. The analysis result shows that, both ASTER DEM and SRTM DEM have high accuracy but in aspects of future availability, ASTER DEM covering larger areas bas relatively more potential than SRTM data.

An Effective Cloth Rendering using Internal Scatter Function (내부 산란함수를 이용한 효과적인 옷감 렌더링)

  • Park, Sun-Yong;Chun, Young-Jae;Oh, Kyoung-Su
    • Journal of Korea Game Society
    • /
    • v.9 no.3
    • /
    • pp.97-105
    • /
    • 2009
  • In this paper, we propose a new rendering scheme of cloth by measuring light-scattering pattern inside the cloth and reproducing using the pattern. To date, the BTF(Bidirectional Texture Function) has been one of the most appropriate method to realistically reconstruct cloth surface. However, the BTF has a couple of defects that it ultimately requires an infinite amount of data and all light effects should be used all together. We noted that internal scattering has a decisive contribution to the reality of cloth. Following this observation, we take an image of a ray of light scattering inside cloth for every position of the cloth sample and determine each pixel value by adding up all light influences arriving from its vicinity. Our method we propose in this paper provides a clue to more realistically represent cloth-like materials, which is one of the most challenging materials to express, by enabling each ray to be controlled individually.

  • PDF

Study on VHCF Fatigue Behaviors and UNSM Effects of Hydrogen Attacked STS 316L (수소취화된 스테인리스강 316L의 VHCF(Very High Cycle Fatigue) 피로특성과 UNSM 효과에 관한 연구)

  • Nahm, Seung-Hoon;Baek, Un-Bong;Suh, Chang-Min;Pyun, Young-Sik
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.11
    • /
    • pp.1011-1020
    • /
    • 2017
  • This study was conducted to investigate the material properties of stainless steel 316L specimens of untreated and UNSM treated material, hydrogen attacked material(100 bar, $300^{\circ}C$ at 120 h) and UNSM treated hydrogen attacked material at room temperature. Results demonstrated that the hydrogen attacked materials showed a tendency toward a slightly decreased fatigue strength, while the hydrogen embrittlement effect was smaller than the S-N curve of conventional untreated material. As compared to untreated material, the fatigue limit of the UNSM treated material increased by 43.8%, while it was 57.1% higher in the UNSM treated hydrogen attacked material than in untreated hydrogen attacked material. The plastic deformation layer was ${\sim}152{\mu}m$ thick, as confirmed by maps showing the level of local plastic deformation affected by the UNSM treatment in three ways: an image quality map, inverse pole figure map, and kernel average misorientation map captured via electron back scatter diffraction. Owing to hydrogen embrittlement, about 90% of surface cracks were smaller than the average grain size of $35{\mu}m$.

A QUALITY CHECK OF THE AKARI MID-INFRARED ALL-SKY DIFFUSE MAP TOWARD THE MASSIVE STAR-FORMING REGIONS NGC 6334 AND NGC 6357

  • Sano, Hidetoshi;Amatsutsu, Tomoya;Kondo, Toru;Nakamichi, Keichiro;Yamagishi, Mitsuyoshi;Ishihara, Daisuke;Oyabu, Shinki;Kaneda, Hidehiro;Tachihara, Kengo;Fukui, Yasuo
    • Publications of The Korean Astronomical Society
    • /
    • v.32 no.1
    • /
    • pp.21-23
    • /
    • 2017
  • We present a comparative study of CO and polycyclic aromatic hydrocarbon (PAH) emission toward a region including the massive star-forming regions of NGC 6334 and NGC 6357. We use the NANTEN $^{12}CO(J=1-0)$ data and the AKARI $9{\mu}m$ All-Sky diffuse map in order to evaluate the calibration accuracy of the AKARI data. We confirm that the overall CO distribution shows a good spatial correspondence with the PAH emission, and their intensities exhibit a good power-law correlation with a spatial resolution down to 4' over the region of $10^{\circ}{\times}10^{\circ}$. We also reveal poorer correlation for small scale structures between the two quantities toward NGC 6357, due to strong UV radiation from local sources. Larger scatter in the correlation toward NGC 6357 indicates higher ionization degree and/or PAH excitation than that of NGC 6334.

Analysis of Graph Types and Characteristics Used in Earth Science Textbooks (지구과학 교과서에 사용된 그래프의 유형 및 특징 분석)

  • Lee, Jin-Bong;Lee, Ki-Young
    • Journal of The Korean Association For Science Education
    • /
    • v.27 no.4
    • /
    • pp.285-296
    • /
    • 2007
  • Graph is a major aspect of science textbooks. In this study, we investigated graph types and characteristics used in high school earth science subject by comparative analysis of science textbooks. The results of the analysis revealed that line graph and contour map was the most widely used graph types in earth science. Among line graphs, multiple line graph and YX graph was dominant. Comparing earth science graphs with other science graphs, earth science graphs exhibited superior in the number and variety. In earth science graphs, the portion of line graph was small, but the portion of contour map and scatter graph was larger than that of other science graphs. YX graph was the most specific graph type in earth science textbooks. The results of our study have implications for reform in function and structure of graph. We suggest that future studies be focused on students' ability of earth science graph interpretation.

Space Physics Sensor on KOMPSAT-1

  • Min, Kyoung-Wook;Choi, Young-Wan;Shin, Young-Hoon;Lee, Jae-Jin;Lee, Dae-Hee;Kim, Jhoon
    • Proceedings of the KSRS Conference
    • /
    • 1998.09a
    • /
    • pp.355-360
    • /
    • 1998
  • A small package of plasma instruments, Space Physics Sensor, will monitor the space environment and its effects on microelectronics in the low altitude region as it operates on board the KOMPSAT-1 from 1999 over the maximum of the solar cycle 23. The Space Physics Sensor (SPS) consists of two parts: the Ionospheric Measurement Sensor (IMS) and the High Energy Particle Detector (HEPD). IMS will make in situ Measurements of the thermal electron density and temperature, and is expected to provide a global map of the thermal electron characteristics and the variability according to the solar and geomagnetic activity in the high altitude ionosphere of the KOMPSAT-t orbit. HEPD will measure the fluxes of high energy protons and electrons, monitor the single event upsets caused by these energetic charged particles, and give the information of the total radiation dose received by the spacecraft. The continuous operation of these sensors, along with the ground measurements such as incoherent scatter radars, digital ionosondes and other spacecraft measurements, will enhance our understanding of this important region of practical use for the low earth orbit satellites.

  • PDF

Q-omics: Smart Software for Assisting Oncology and Cancer Research

  • Lee, Jieun;Kim, Youngju;Jin, Seonghee;Yoo, Heeseung;Jeong, Sumin;Jeong, Euna;Yoon, Sukjoon
    • Molecules and Cells
    • /
    • v.44 no.11
    • /
    • pp.843-850
    • /
    • 2021
  • The rapid increase in collateral omics and phenotypic data has enabled data-driven studies for the fast discovery of cancer targets and biomarkers. Thus, it is necessary to develop convenient tools for general oncologists and cancer scientists to carry out customized data mining without computational expertise. For this purpose, we developed innovative software that enables user-driven analyses assisted by knowledge-based smart systems. Publicly available data on mutations, gene expression, patient survival, immune score, drug screening and RNAi screening were integrated from the TCGA, GDSC, CCLE, NCI, and DepMap databases. The optimal selection of samples and other filtering options were guided by the smart function of the software for data mining and visualization on Kaplan-Meier plots, box plots and scatter plots of publication quality. We implemented unique algorithms for both data mining and visualization, thus simplifying and accelerating user-driven discovery activities on large multiomics datasets. The present Q-omics software program (v0.95) is available at http://qomics.sookmyung.ac.kr.

Recent Research Trend Analysis for the Journal of Society of Korea Industrial and Systems Engineering Using Topic Modeling (토픽모델링을 활용한 한국산업경영시스템학회지의 최근 연구주제 분석)

  • Dong Joon Park;Pyung Hoi Koo;Hyung Sool Oh;Min Yoon
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.46 no.3
    • /
    • pp.170-185
    • /
    • 2023
  • The advent of big data has brought about the need for analytics. Natural language processing (NLP), a field of big data, has received a lot of attention. Topic modeling among NLP is widely applied to identify key topics in various academic journals. The Korean Society of Industrial and Systems Engineering (KSIE) has published academic journals since 1978. To enhance its status, it is imperative to recognize the diversity of research domains. We have already discovered eight major research topics for papers published by KSIE from 1978 to 1999. As a follow-up study, we aim to identify major topics of research papers published in KSIE from 2000 to 2022. We performed topic modeling on 1,742 research papers during this period by using LDA and BERTopic which has recently attracted attention. BERTopic outperformed LDA by providing a set of coherent topic keywords that can effectively distinguish 36 topics found out this study. In terms of visualization techniques, pyLDAvis presented better two-dimensional scatter plots for the intertopic distance map than BERTopic. However, BERTopic provided much more diverse visualization methods to explore the relevance of 36 topics. BERTopic was also able to classify hot and cold topics by presenting 'topic over time' graphs that can identify topic trends over time.

The Comparison of Motion Correction Methods in Myocardial Perfusion SPECT (심근관류 SPECT에서 움직임 보정 방법들의 비교)

  • Park, Jang-Won;Nam, Ki-Pyo;Lee, Hoon-Dong;Kim, Sung-Hwan
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.28-32
    • /
    • 2014
  • Purpose Patient motion during myocardial perfusion SPECT can produce images that show visual artifacts and perfusion defects. This artifacts and defects remain a significant source of unsatisfactory myocardial perfusion SPECT. Motion correction has been developed as a way to correct and detect the patient motion for reducing artifacts and defects, and each motion correction uses different algorithm. We corrected simulated motion patterns with several motion correction methods and compared those images. Materials and Methods Phantom study was performed. The anthropomorphic torso phantom was made with equal counts from patient's body and simulated defect was added in myocardium phantom for to observe the change in defect. Vertical motion was intentionally generated by moving phantom downward in a returning pattern and in a non-returning pattern throughout the acquisition. In addition, Lateral motion was generated by moving phantom upward in a returning pattern and in a non-returning pattern. The simulated motion patterns were detected and corrected similarly to no-motion pattern image and QPS score, after Motion Detection and Correction Method (MDC), stasis, Hopkins method were applied. Results In phantom study, Changes of perfusion defect were shown in the anterior wall by the simulated phantom motions, and inferior wall's defect was found in some situations. The changes derived from motion were corrected by motion correction methods, but Hopkins and Stasis method showed visual artifact, and this visual artifact did not affect to perfusion score. Conclusion It was confirmed that motion correction method is possible to reduce the motion artifact and artifactual perfusion defect, through the apply on the phantom tests. Motion Detection and Correction Method (MDC) performed better than other method with polar map image and perfusion score result.

  • PDF