• Title/Summary/Keyword: Scanning transmission electron microscope

Search Result 320, Processing Time 0.026 seconds

Interrelationship between Structure and Mechanical Properties of Al-Cu-Li-X(In,Be) Alloy (Al-Cu-Li-X(In,Be) 합금(合金)의 조직(組織)과 기계적성질(機械的性質)의 상호관계(相互關係))

  • Lee, Sung-Ho;Lee, Jong-Soo;Kim, Suk-Won;Woo, Kee-Do
    • Journal of Korea Foundry Society
    • /
    • v.15 no.4
    • /
    • pp.351-359
    • /
    • 1995
  • The effects of In and Be additions on the aging behaviors and mechanical properties in the Al-Cu-Li alloy were investigated using the transmission electron microscope, the scanning electron microscope, hardness and tensile strength measurement. The aging is promoted and the double hardness peak is appeared by the addition of In and Be in the Al-Cu-Li alloy. The strength is increased, but the elongation and toughness are decreased by the addition of In in the Al-Cu-Li alloy. And the Al-Cu-Li-In-Be alloy has good combination with the strength, the elogation and toughness than Al-Cu-Li-In alloy.

  • PDF

Mass production of carbon nanotubes using Vapor Phase Growth (기상합성법을 이용한 탄소나노튜브의 대량합성)

  • 류승철;이태재;이철진
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.123-126
    • /
    • 2001
  • Multiwalled carbon nanotubes were massively produced by the catalytic reaction of C$_2$H$_2$ - Fe(CO)$\sub$5/ mixture at 750 - 950$^{\circ}C$ in a quartz tube reactor and over quartz substrates. Well-aligned MWNT array grows perpendicular to the quartz tube reactor and the quartz substrates at an average of 60 nm in diameter and up to several thousands of micrometers in length. This method does not require any pretreatment of substrates and CNTs are grown at atmospheric pressure. It could be suitable for mass production of multiwalled nanotubes. Scanning electron microscope and transmission electron microscope images of the nanotubes deposited on the substrates allowed us to monitor the quality of MWNTs grown under different operating conditions.

  • PDF

Antimicrobial Activities of Korean Medicinal Herb Extracts for Preserving Greenhouse Fresh Produce (시설채소산물의 선도유지를 위한 한국산 약용식물추출물의 항균특성)

  • 정순경;이숙지
    • Food Science and Preservation
    • /
    • v.5 no.1
    • /
    • pp.13-21
    • /
    • 1998
  • Korean medicinal herb extracts(KMHE) were applied to the preservation of greenhouse produce in order to prove their effectiveness. KMHE showed remarkable antimicrobial effects against Bacillus cereus, Peudomonas syringae, and Corynebacterium xerosis causing the postharvest decay of greenhouse produce. Among KMHE the extracts of Rheum palmatum L. and Coptis chinensis Franch most obviously inhibited the growth of microorganims causing the Postharvest decay of greenhouse produce, which destroyed to undetectable levels when treated with more than 500ppm of KMHE. The activities of KMHE were stable in the wide spectrum of pH and temperature. Direct visualization of microbial cells by using both transmission electron microscope and scanning electron microscope showed microbial cell membrane the function of which was destroyed by treating with the dilute solutions of KMHE. This change of cellular membrane permeability could be identified in the experiment that O-nitrophenyl-$\beta$-D-galactopyranoside(ONPG), the artificial substrate of $\beta$-galactosidase, was hydrolyzed in the presence of KMHE, indicating that the membrane was perturbed by KMHE.

  • PDF

Study on the bainitic microstructure in low carbon HSLA steels (저탄소.저합금 강의 베이나이트 미세 구조 연구)

  • Kang, J.S.;Ahn, S.S.;Yoo, J.Y.;Park, C.G.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2007.10a
    • /
    • pp.154-157
    • /
    • 2007
  • The austenite phase observed in low carbon HSLA steels is well known to be decomposed to various bainitic microstructures, such as granular bainite, acicular ferrite and bainitic ferrite during continuous cooling process. These bainitic microstructures have been usually identified by using either scanning electron microscope (SEM) or transmission electron microscope (TEM). However, SEM and TEM images do no exactly coincide, because of the quite different sample preparation method in SEM and TEM observations. These conventional analysis method is, thus, not suitable for characterization of the complex bainitic microstructure. In this study, focused ion beam (FIB) technique was applied to make site-specific TEM specimens and to identify the 3-dimensional grain morphologies of the bainitic microstructure. The morphological feature and grain boundary characteristics of each bainitic microstructure were exactly identified.

  • PDF

Morphology Control of Single Crystalline Rutile TiO2 Nanowires

  • Park, Yi-Seul;Lee, Jin-Seok
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.10
    • /
    • pp.3571-3574
    • /
    • 2011
  • Nano-scaled metal oxides have been attractive materials for sensors, photocatalysis, and dye-sensitization for solar cells. We report the controlled synthesis and characterization of single crystalline $TiO_2$ nanowires via a catalyst-assisted vapor-liquid-solid (VLS) and vapor-solid (VS) growth mechanism during TiO powder evaporation. Scanning electron microscope (SEM) and transmission electron microscope (TEM) studies show that as grown $TiO_2$ materials are one-dimensional (1D) nano-structures with a single crystalline rutile phase. Also, energy-dispersive X-ray (EDX) spectroscopy indicates the presence of both Ti and O with a Ti/O atomic ratio of 1 to 2. Various morphologies of single crystalline $TiO_2$ nano-structures are realized by controlling the growth temperature and flow rate of carrier gas. Large amount of reactant evaporated at high temperature and high flow rate is crucial to the morphology change of $TiO_2$ nanowire.

Cross-Corresponding Preparation of Organometallic Acetylferrocene Micro-Nanostructures in Bidirection Using Top-Down and Bottom-Up Approaches

  • Yuan, Pin-Shi;Wu, Zing-Sheng
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.12
    • /
    • pp.2890-2894
    • /
    • 2009
  • The larch-fruit-like acetylferrocene micro-nanomaterials and beltlike acetylferrocene micro-nanomaterials have been cross-correspondingly prepared in bidirection by the top-down and bottom-up approach, respectively, and characterized by scanning electron microscope, transmission electron microscope and X-ray diffractometer. UV-Vis absorption spectra show that the redshift was found in the acetylferrocene micro-nanomaterials compared to that in solution. The formation mechanism of the acetylferrocene micro-nanomaterials is also proposed. This work provides a new strategy for the material synthesis and preparation and may realize the reuse of organometallic materials.

Microstructural and Magnetic Characterization of Fe Nanosized Powder Synthesized by Pulsed Wire Evaporation

  • Kim, Deok Hyeon;Lee, Bo Wha
    • Journal of Magnetics
    • /
    • v.22 no.1
    • /
    • pp.100-103
    • /
    • 2017
  • We studied the microstructure and magnetic properties of Fe nanosized powder synthesized by the pulsed wire evaporation method. The x-ray diffraction spectrum confirmed that this powder had a pure ${\alpha}$-Fe phase. Scanning electron microscope and transmission electron microscope measurements indicated that the prepared powder had uniform spherical shape with core-shell structure. The mean powder size was about 35 nm and the thickness of the surface passivation layer was about 5 nm. Energy dispersive X-ray spectroscopy measurement indicated that the surface passivation layer was iron oxide. Magnetic field dependent magnetization measurement at room temperature showed that the maximum magnetization of the prepared powder was 177.1 emu/g at 1 T.

Electrodeposition of Polypyrrole Nanowires within Vertically Oriented Mesoporous Silica Template

  • Kang, Ho-Suk;Lee, Ho-Chun;Kwak, Ju-Hyoun
    • Journal of the Korean Electrochemical Society
    • /
    • v.14 no.1
    • /
    • pp.22-26
    • /
    • 2011
  • Polypyrrole (Ppy) nanowire has been electrochemically synthesized via vertically oriented mesoporous silica template. The mesoporous template is also electrochemically deposited on indium tin oxide coated (ITO) glass from tetraethyl orthosilicate (TEOS) and cetyltrimethylammonium bromide (CTAB) surfactant. The highly ordered silica template is demonstrated to be 100~120nm thick with the pores of 4~5 nm diameter by scanning electron microscope (SEM) and transmission electron microscope (TEM). Ppy is formed to fill pores of the silica template from pyrrole solution by electrochemical oxidation. The Ppy in Ppy/silica/ITO composite was found to exhibit reversible electrochemical activity, as characterized by cyclic voltammetry (CV).

Nanoparticle Synthesis by Pulsed Laser Ablation of Consolidated Microparticles (압밀 금속 마이크로 입자의 펄스 레이저 ABLATION에 의한 나노입자 합성)

  • 장덕석;오부국;김동식
    • Laser Solutions
    • /
    • v.5 no.2
    • /
    • pp.31-38
    • /
    • 2002
  • This paper describes the process of nanoparticle synthesis by laser ablation of consolidated microparticles. We have generated nanoparticles by high-power pulsed laser ablation of Al, Cu and Ag microparticles using a Q-switched Nd:YAG laser (wavelength 355 nm, FWHM 5 ㎱, fluence 0.8∼2.0 J/㎠). Microparticles of mean diameter 18∼80 ㎛ are ablated in the ambient air The generated nanoparticles are collected on a glass substrate and the size distribution and morphology are examined using a scanning electron microscope and a transmission electron microscope. The effect of laser fluence and collector position on the distribution of particle size is investigated. The dynamics of ablation plume and shock wave is analyzed by monitoring the photoacoustic probe-beam deflection signal. Nanosecond time-resolved images of the ablation process are also obtained by laser flash shadowgraphy. Based on the experimental results, discussions are made on the dynamics of ablation plume.

  • PDF

High Speed and Sensitive X-ray Analysis System with Automated Aberration Correction Scanning Transmission Electron Microscope

  • Inada, Hiromi;Hirayama, Yoichi;Tamura, Keiji;Terauchi, Daisuke;Namekawa, Ryoji;Shichiji, Takeharu;Sato, Takahiro;Suzuki, Yuya;Ohtsu, Yoshihiro;Watanabe, Keitaro;Konno, Mitsuru;Tanaka, Hiroyuki;Saito, Koichiro;Shimoyama, Wataru;Nakamura, Kuniyasu;Kaji, Kazutoshi;Hashimoto, Takahito
    • Applied Microscopy
    • /
    • v.45 no.1
    • /
    • pp.1-8
    • /
    • 2015
  • We have developed a new HD-2700 (Hitachi High-Technologies Corp., Japan) scanning transmission electron microscope (STEM) that includes an automatic aberration correction function, and a large-solid-angle energy-dispersive X-ray spectroscopy detector that enables high-resolution and sensitive analysis. For observation with atomic resolution, using spherical-aberration-corrected STEM, in order that satisfactory performance of the device can be achieved readily, and within a short time, irrespective of the operator's skill level, a spherical-aberration-correction device with an automatic aberration-correction function was developed. This automatic aberration-correction function carries out the entire correction-related process (aberration measurement, selection and correction) automatically, with automatic selection of the aberrations that require correction, and automatic measurement of the appropriate corrections.