• 제목/요약/키워드: Scanning Device

검색결과 480건 처리시간 0.025초

쥬얼리 데이터를 이용한 쾌속조형장치의 주사경로 생성 시간에 관한 연구 (Study on the Laser Scanning Path Creation Time of Rapid prototype Using Jewellery Data)

  • 한민식;김태호;김민주;이준희;전언찬
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2004년도 추계학술대회 논문집
    • /
    • pp.190-193
    • /
    • 2004
  • This paper presents studies on the creation time of scanning path using rapid prototype device. In the case of Jewellery, it needs to take time too much at the whole process of rapid prototype in accordance with heigh of the multi-layered. When increases the number of polygon by heigh of the Multi-layered, it has proper influence on the creation time of scanning path. Therefore, we can get the spending time and the number of polygon for the creation during increase the heigh of the multi-layered. These values are showed by the quantitative. We try to analyze relation between these and heigh of the multi-layered.

  • PDF

Measurements of Blood Viscosity Using a Pressure-Scanning Slit Viscometer

  • Sehyun Shin;Lee, Sung-Woo;Ku, Yun-Hee
    • Journal of Mechanical Science and Technology
    • /
    • 제18권6호
    • /
    • pp.1036-1041
    • /
    • 2004
  • A newly designed pressure-scanning slit viscometer is developed to combine an optical device without refraction while measuring blood viscosity over a range of shear rates. The capillary tube in a previously designed capillary viscometer was replaced with a transparent slit, which is affordable to mount optical measurement of flowing blood cells. Using a pressure transducer, we measured the change of pressure in a collecting chamber with respect to the time, p(t), from which the viscosity and shear rate were mathematically calculated. For water, standard oil and whole blood, excellent agreement was found between the results from the pressure-scanning slit viscometer and those from a commercially available rotating viscometer. This new viscometer overcomes the drawbacks of the previously designed capillary viscometer in the measuring whole blood viscosity. First, the pressure-scanning slit viscometer can combine an optical instrument such as a microscope. Second, this design is low cost and simple (i.e., ease of operation, no moving parts, and disposable).

플라즈마 진단을 위한 Scanning Electron Microscope Image의 신경망 인식 모델 (Neural Network Recognition of Scanning Electron Microscope Image for Plasma Diagnosis)

  • 고우람;김병환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.132-134
    • /
    • 2006
  • To improve equipment throughput and device yield, a malfunction in plasma equipment should be accurately diagnosed. A recognition model for plasma diagnosis was constructed by applying neural network to scanning electron microscope (SEM) image of plasma-etched patterns. The experimental data were collected from a plasma etching of tungsten thin films. Faults in plasma were generated by simulating a variation in process parameters. Feature vectors were obtained by applying direct and wavelet techniques to SEM Images. The wavelet techniques generated three feature vectors composed of detailed components. The diagnosis models constructed were evaluated in terms of the recognition accuracy. The direct technique yielded much smaller recognition accuracy with respect to the wavelet technique. The improvement was about 82%. This demonstrates that the direct method is more effective in constructing a neural network model of SEM profile information.

  • PDF

Implementation of Cost-effective Common Path Spectral Domain Free-hand Scanning OCT System

  • Shoujing Guo;Xuan Liu;Jin U. Kang
    • Current Optics and Photonics
    • /
    • 제7권2호
    • /
    • pp.176-182
    • /
    • 2023
  • Optical coherence tomography (OCT) is being developed to guide various ophthalmic surgical procedures. However, the high cost of the intraoperative OCT system limits its availability mostly to the largest hospitals and healthcare systems. In this paper, we present a design and evaluation of a low-cost intraoperative common-path free-hand scanning OCT system. The lensed fiber imaging probe is designed and fabricated for intraocular use and the free-hand scanning algorithm that could operate at a low scanning speed was developed. Since the system operates at low frequencies, the cost of the overall system is significantly lower than other commercial intraoperative OCT systems. The assembled system is characterized and shows that it meets the design specifications. The handheld OCT imaging probe is tested on multilayer tape phantom and ex-vivo porcine eyes. The results show that the system could be used as an intraoperative intraocular OCT imaging device.

건축물 실시간 원격 스캔을 위한 SLAM 시스템 개발 시 고려사항 (Considerations for Developing a SLAM System for Real-time Remote Scanning of Building Facilities)

  • 강태욱
    • 한국BIM학회 논문집
    • /
    • 제10권1호
    • /
    • pp.1-8
    • /
    • 2020
  • In managing building facilities, spatial information is the basic data for decision making. However, the method of acquiring spatial information is not easy. In many cases, the site and drawings are often different due to changes in facilities and time after construction. In this case, the site data should be scanned to obtain spatial information. The scan data actually contains spatial information, which is a great help in making space related decisions. However, to obtain scan data, an expensive LiDAR (Light Detection and Ranging) device must be purchased, and special software for processing data obtained from the device must be available.Recently, SLAM (Simultaneous localization and mapping), an advanced map generation technology, has been spreading in the field of robotics. Using SLAM, 3D spatial information can be obtained quickly in real time without a separate matching process. This study develops and tests whether SLAM technology can be used to obtain spatial information for facility management. This draws considerations for developing a SLAM device for real-time remote scanning for facility management. However, this study focuses on the system development method that acquires spatial information necessary for facility management through SLAM technology. To this end, we develop a prototype, analyze the pros and cons, and then suggest considerations for developing a SLAM system.

실험실용 간이 분광기 구동장치 (A Simple Laboratory Monochromator Controller)

  • 성학제;김태삼
    • 분석과학
    • /
    • 제6권3호
    • /
    • pp.345-348
    • /
    • 1993
  • A monchromator controller has been built to drive directly by a personal computer. This controller gives better conveniency and accuracy on spectroscopic experiment when a monochromator has deficient driver. This controller consists with simple electronic circuit and control program. The original spectroscopic precision is retained by using stepper motor. The rate changing method is adopted for short slew time. And the scanning is synchronized with spectrum recording device. Because the controller includes electronic counting ciruit, other program can be executed on personal computer during monochromator scanning.

  • PDF

리얼 타임 리눅스 시스템 설계 (Real Time Linux System Design)

  • 이아리;홍선학
    • 디지털산업정보학회논문지
    • /
    • 제10권2호
    • /
    • pp.13-20
    • /
    • 2014
  • In this paper, we implemented the object scanning with nxtOSEK which is an open source platform. nxtOSEK consists of device driver of leJOS NXJ C/Assembly source code, TOPPERS/ATK(Automotive real time Kernel) and TOPPERS/JSP Real-Time Operating System source code that includes ARM7 specific porting part, and glue code make them work together. nxtOSEK can provide ANSI C by using GCC tool chain and C API and apply for real-time multi tasking features. We experimented the 3D scanning with ultra sonic and laser sensor which are made directly by laser module diode and experimented the measurement of scanning the object by knowing x, y, and z coordinates for every points that it scans. In this paper, the laser module is the dimension of $6{\times}10[mm]$ requiring 5volts/5[mW], and used the laser light of wavelength in the 650[nm] range. For detecting the object, we used the beacon detection algorithm and as the laser light swept the objects, the photodiode monitored the ambient light at interval of 10[ms] which is called a real time. We communicated the 3D scanning platform via bluetooth protocol with host platform and the results are displayed via DPlot graphic tool. And therefore we enhanced the functionality of the 3D scanner for identifying the image scanning with laser sensor modules compared to ultra sonic sensor.

열역학적 및 속도론적 분석을 통한 THPP의 노화 안정성 확인 (Confirmation of Long-term stability on THPP using thermodynamic and kinetic analysis)

  • 이준우;김상원;최경원;이승복;류병태;박태호
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2017년도 제48회 춘계학술대회논문집
    • /
    • pp.513-516
    • /
    • 2017
  • 화약 기반 소자 (PMD)에서 장기간 보관을 하게 되면 소자 안에 있는 화약이 노화되어 폭발력에 변화가 생기기 때문에, 일정 기간이 지나면 폐기 처분을 하게 된다. 그렇기 때문에 PMD 안에 사용하는 화약은 자발적 혹은 외부적 요인에 대하여 화학적 및 물리적으로 안정해야 한다. 기존에 사용되는 화약으로서 $BKNO_3$과 THPP를 대표적으로 이용하기 때문에, 이 화약들을 기반으로 하여 열역학적 및 속도론적 분석을 실시하였다. Differential scanning calorimeter (DSC)를 이용하여 발열량과 반응속도를 분석하였는데, 그 결과 THPP에서는 열량 차이 및 반응속도에 큰 변화가 보이지 않았다. 추가적으로, 노화에 직접적으로 연관되는 산화막 형성을 확인하기 위하여 XPS 및 TEM-EDS 분석하였는데, 열적 분석 결과와 상응하는 결과로서 산화막이 관측 되지 않았다. 이는 THPP가 장기 안정성 측면에서 가장 유명한 화약이라고 판단 할 수 있다.

  • PDF

In-situ rf treatment of multiwall carbon nanotube with various post techniques for enhanced field emission

  • Ahn, Kyoung-Soo;Kim, Jun-Sik;Kim, Ji-Hoon;Kim, Chae-Ok;Hong, Jin-Pyo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2003년도 International Meeting on Information Display
    • /
    • pp.859-862
    • /
    • 2003
  • Well-aligned multiwall carbon nanotubes (MWCNTs) were prepared at low temperature of 400 $^{\circ}C$ by utilizing a radio frequency plasma-enhanced chemical vapor deposition (rf-PECVD) system. The MWCNTs were treated by an external rf plasma source and an ultra-violet laser in order to modify structural defect of carbon nanotube and to ablate possible contamination on carbon nanotube surface. Structural properties of carbon nanotubes were investigated by using a scanning electron microscopy (SEM), Raman spectroscopy, Fourier transformer Infrared spectroscopy (FTIR) and transmission electron microscope (TEM). In addition, the emission properties of the MWNTs were measured for the application of field emission display (FED) in near future. Various post treatments were found to improve the field emission property of carbon nanotubes.

  • PDF

EPD time delay in etching of stack down WSix gate in DPS+ poly chamber

  • Ko, Yong Deuk;Chun, Hui-Gon
    • 한국반도체및디스플레이장비학회:학술대회논문집
    • /
    • 한국반도체및디스플레이장비학회 2002년도 추계학술대회 발표 논문집
    • /
    • pp.130-136
    • /
    • 2002
  • Device makers want to make higher density chips as devices shrink, especially WSix poly stack down is one of the key issues. However, EPD (End Point Detection) time delay was happened in DPS+ poly chamber which is a barrier to achieve device shrink because EPD time delay killed test pattern and next generation device. To investigate the EPD time delay, a test was done with patterned wafers. This experimental was carried out combined with OES(Optical Emission Spectroscopy) and SEM (Scanning Electron Microscopy). OES was used to find corrected wavelength in WSix stack down gate etching. SEM was used to confirm WSix gate profile and gate oxide damage. Through the experiment, a new wavelength (252nm) line of plasma is selected for DPS+ chamber to call correct EPD in WSix stack down gate etching for current device and next generation device.

  • PDF