• 제목/요약/키워드: Scanning Device

검색결과 481건 처리시간 0.032초

연마법이 치과용 복합레진의 표면 조도에 미치는 영향에 관한 실험적 연구

  • 양홍서
    • 대한치과의사협회지
    • /
    • 제24권7호통권206호
    • /
    • pp.633-642
    • /
    • 1986
  • In order to evaluate the effects of various finishing devices (Sof-Lex disc, diamond point, rubber point, fussure bur) on the surface roughness or two composite resins (Restodent, Enamelite 500), 15 specimens for each composite resin were made in the mold. Composite resin was prepared on the mixing pad by manufacturer's direction and filled in the mold cavity. A sheet of matrix is immediately placed on it and hold for 5 minutes to polymerize the resin. Surface finish was done after 10 minutes from the start of mixing. Scanning electron microscopy and surface profilometer were used to evaluate the surface roughness, porositites and striations of dental composite resins. The following results were observed; 1. The best finished surface was formed by celluloid matrix band. 2. Rubber point was excellent polishing device for Restodent. 3. Sof-Lex disc was the device of choice for polishing Enamelite 500. 4. Different polishing methods were effective for different composite resins. 5. SEMs of variously finished surfaces supported the profilometer measurements.

  • PDF

칼날주사방법에 의한 일차원 CCD의 MTF 측정 (Modulation Transfer Function Measurement of a Linear Charge Coupled Device Imager by Using a Knife-Edge Scanner)

  • 조현모;이윤우;이인원;이상태;이종웅
    • 한국광학회지
    • /
    • 제6권3호
    • /
    • pp.173-177
    • /
    • 1995
  • 칼날주사방법을 이용한 CCD의 MTF 측정장치를 제작하고 일차원 CCD의 MTF특성을 측정하였다. 주사방향에 수직인 직선과 칼날이 이루는 각도에 따른 CCD MTF 측정값의 변화는 $1^{\circ}$ 미만의 작은 각도변화에 의해서도 MTF값이 크게 변함을 알 수 있었으며 CCD의 MTF 측정값은 간섭필터와 텅스텐 필라멘트가 조합된 파장에 따라 다른 값을 나타내었다. 또한 광원의 색온도 변화에 의한 CCD의 MTF특성과 CCD 화소들의 균일성을 조사하였다.

  • PDF

Electrochemical Signal Amplification by Redox Cycling in Distance-Controlled Nanogap Devices

  • Park, Dae Keun;Park, Jong Mo;Shin, Jong-Hwan;Yun, Wan Soo
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제45회 하계 정기학술대회 초록집
    • /
    • pp.269-269
    • /
    • 2013
  • Redox cycling in between the two working electrodes in an electrochemical cell can lead a great signal enhancement. In this work, we report on a systematic examination of current amplification along with the decrease in the gap distance of a nanogap device which was fabricated by the combination of photo and chemical lithography [1]. The gap distance was controlled by the chemical lithographic process of surfacecatalyzed growth of metallic layer on pre-defined electrodes with wider initial gap. Enhancement of the redox current of ferri/ferrocyanide was observed upon gap distance reduction and the current is amplified about a thousand times in this redox system when the gap distance was decreased from 200 nm to 30 nm. The experimental results were discussed on the basis of the cyclic voltammetry (CV), atomic force microscopy (AFM) and scanning electron microscopy (SEM).

  • PDF

Ocean Scanning Multi-spectral Imager (OSMI) 특성 (Characteristics of Ocean Scanning Multi-spectral Imager(OSMI))

  • Young Min Cho;Sang-Soon Yong;Sun Hee Woo;Sang-Gyu Lee;Kyoung-Hwan Oh;Hong-Yul Paik
    • 대한원격탐사학회지
    • /
    • 제14권3호
    • /
    • pp.223-231
    • /
    • 1998
  • 해양생물학 연구를 위해 전세계 바다색 관측을 수행하게 될 아리랑 1호 위성(Korean Multi-Purpose SATellite. KOMPSAT)의 탑재체 Ocean Scanning Multispectral Imager(OSMI)를 개발하였다. OSMI는 관측폭 800km 이내에서 1km 이하의 지상해상도를 갖고 whisk-broom 주사 기법으로 해양표면의 영상을 얻는다. OSMI는 3년의 수명 동안 20%의 궤도 운영 duty cycle을 갖으며 궤도 운영 중 영상 자료의 gain/offset 조정이 가능하고 영상자료 저장 기능이 내장되도록 설계되었다. 궤도 운영 중 센서 보정을 위해 OSMI는 태양 보정과 암흑 보정을 수행한다. OSMI는 2차원 Charge Coupled Device(CCD) Focal Plane Array(FPA)를 사용하는 다중 분광 촬영기로서 400nm에서 900nm가지의 파장 대역에 대한 결상이 가능하다. 이 파장대역 중에서 궤도 운영 중 지상명령을 통해 선택되는 6개 분광 채널을 사용하여 해양표면이 관측된다. 센서 성능은 지상 특성 시험 단계에서 412, 443, 490, 510, 555, 670, 765 그리고 865nm의 8개 분광 대역에 대해 측정되었다. 이 지상 특성 시험 결과와 더불어 태양/암흑 보정이 궤도 분광 채널 선택 및 보정에 사용될 것이다. 운영중 분광 채널 선택 기능은 바다색 관측 및 해양생물학 연구에 큰 유연성을 줄 것이다.

RUNNING-IN OF DLC COATED STEEL IN BOUNDARY LUBRICATION

  • Stavlid, N.;Wiklund, U.
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2002년도 proceedings of the second asia international conference on tribology
    • /
    • pp.137-138
    • /
    • 2002
  • The benefits of using DLC coatings on steel in dry sliding are well known. The present study has investigated the effects of using the same materials but in a boundary lubricated environment. Tribological tests were performed using a load-scanning device and a lubricant with an extreme-pressure (EP) additive. XPS and grazing incidence XRD are used for chemical analysis. The chemical composition of the resulting tribofilm is correlated to different friction behaviors and contact loads, and indicates that high loads are beneficial for formation of low friction tribofilm.

  • PDF

Laser projection system that uses a 2D MEMS scanner

  • Seo, Jung-Hoon;Choi, Jung-Hwan;Kim, Yong-Ki;Yi, Jong-Kwon;Kwon, Jae-Wook
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2009년도 9th International Meeting on Information Display
    • /
    • pp.478-480
    • /
    • 2009
  • This experiment implemented a laser projection system that used the 2D MEMS scanner as the driving method for the display device. The 2D MEMS scanner, which can scan the images horizontally and vertically, was applied to drive the projection system using the interlaced scanning method. The laser was directly modulated to implement the grayscale and the images were WVGA resolution quality.

  • PDF

Measurement and Scale Effects of Digitized Virtual Human Head

  • Takakazu, Ishimatsu;Chan, Tony
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.89.1-89
    • /
    • 2001
  • Measurement of complex surfaces without touching is desirable in several fields. This arises mainly for measurement of complex surfaces including those surfaces that deform during touch. Our research presented in this paper describes the use of a 3D digitizer for scanning 3D objects. The use of such a device, in addition to proper calibration, requires proper scaling in all three dimensions. We propose measurement techniques to measure various aspects of the surface circumference, area and volume. We also present experiments from using a 3D Minolta digitizer for measuring 3D human heads.

  • PDF

Scanning Probe Microscopy를 이용한 국소영역에서의 실리콘 나노크리스탈의 전기적 특성 분석 (Characterization of Electrical Properties of Si Nanocrystals Embedded in a SiO$_{2}$ Layer by Scanning Probe Microscopy)

  • 김정민;허현정;강치중;김용상
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권10호
    • /
    • pp.438-442
    • /
    • 2005
  • Si nanocrystal (Si NC) memory device has several advantages such as better retention, lower operating voltage, reduced punch-through and consequently a smaller cell area, suppressed leakage current. However, the physical and electrical reasons for this behavior are not completely understood but could be related to interface states of Si NCs. In order to find out this effect, we characterized electrical properties of Si NCs embedded in a SiO$_{2}$ layer by scanning probe microscopy (SPM). The Si NCs were generated by the laser ablation method with compressed Si powder and followed by a sharpening oxidation. In this step Si NCs are capped with a thin oxide layer with the thickness of 1$\~$2 nm for isolation and the size control. The size of 51 NCs is in the range of 10$\~$50 m and the density around 10$^{11}$/cm$^{2}$ It also affects the interface states of Si NCs, resulting in the change of electrical properties. Using a conducting tip, the charge was injected directly into each Si NC, and the image contrast change and dC/dV curve shift due to the trapped charges were monitored. The results were compared with C-V characteristics of the conventional MOS capacitor structure.

반도체 장치의 결함해석 (Fault Analysis of Semiconductor Device)

  • 박석준;최성배;오창섭
    • 에너지공학
    • /
    • 제25권1호
    • /
    • pp.192-197
    • /
    • 2016
  • 새로운 재료가 개발되어 점점 반도체 디바이스의 적용으로 인해 반도체 장치 구조의 미세화를 촉진하고 있고 반도체 디바이스의 제조공정에서는 초기불량이나 일정시간 가동 후의 고장이 끊이지 않고 발생하고 있어 그 결함에 대한 해석은 날이 갈수록 중요해지고 있다. 여기서는 반도체 디바이스의 전기적 고장 검출과 디바이스 결함부의 물리해석에 대해 서술한다. 물리해석에는 주사전자현미경이나 투과전자현미경, 집속이온빔가공장치와 같은 전자나 이온을 이용한 장치가 사용되는데 여기서는 그 사용기술과 특성에 대해 서술하고자 한다.

Structural and Electrical Properties of an Electrolyte-insulator-metal Device with Variations in the Surface Area of the Anodic Aluminum Oxide Template for pH Sensors

  • Kim, Yong-Jun;Lee, Sung-Gap;Yeo, Jin-Ho;Jo, Ye-Won
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권6호
    • /
    • pp.2364-2367
    • /
    • 2015
  • In this study, we fabricated an electrolyte-insulator-metal (EIM) device incorporating a high-k Al2O3 sensing membrane using a porous anodic aluminum oxide (AAO) through a two-step anodizing process for pH detection. The structural properties were observed by field-emission scanning electron microscopy (FE-SEM) and X-ray diffraction patterns (XRD). Electrochemical measurements taken consisted of capacitance-voltage (C-V), hysteresis voltage and drift rates. The average pore diameter and depth of the AAO membrane with a pore-widening time of 20 min were 123nm and 273.5nm, respectively. At a pore-widening time of 20 min, the EIM device using anodic aluminum oxide exhibited a high sensitivity (56mV/pH), hysteresis voltage (6.2mV) and drift rate (0.25mV/pH).