• 제목/요약/키워드: Scanning Confocal Microscope

검색결과 198건 처리시간 0.022초

ANALYSIS OF THE PERMEABILITY CHARACTERISTICS ALONG ROUGH-WALLED FRACTURES USING A HOMOGENIZATION METHOD

  • Chae, Byung-Gon;Choi, Jung-Hae;Ichikawa, Yasuaki;Seo, Yong-Seok
    • Nuclear Engineering and Technology
    • /
    • 제44권1호
    • /
    • pp.43-52
    • /
    • 2012
  • To compute a permeability coefficient along a rough fracture that takes into account the fracture geometry, this study performed detailed measurements of fracture roughness using a confocal laser scanning microscope, a quantitative analysis of roughness using a spectral analysis, and a homogenization analysis to calculate the permeability coefficient on the microand macro-scale. The homogenization analysis is a type of perturbation theory that characterizes the behavior of microscopically inhomogeneous material with a periodic boundary condition in the microstructure. Therefore, it is possible to analyze accurate permeability characteristics that are represented by the local effect of the facture geometry. The Cpermeability coefficients that are calculated using the homogenization analysis for each rough fracture model exhibit an irregular distribution and do not follow the relationship of the cubic law. This distribution suggests that the permeability characteristics strongly depend on the geometric conditions of the fractures, such as the roughness and the aperture variation. The homogenization analysis may allow us to produce more accurate results than are possible with the preexisting equations for calculating permeability.

A STUDY OF THE PRESSURE SOLUTION AND DEFORMATION OF QUARTZ CRYSTALS AT HIGH pH AND UNDER HIGH STRESS

  • Choi, Jung-Hae;Seo, Yong-Seok;Chae, Byung-Gon
    • Nuclear Engineering and Technology
    • /
    • 제45권1호
    • /
    • pp.53-60
    • /
    • 2013
  • Bentonite is generally used as a buffer material in high-level radioactive waste disposal facilities and consists of 50% quartz by weight. Quartz strongly affects the behavior of bentonite over very long periods. For this reason, quartz dissolution experiment was performed under high-pressure and high-alkalinity conditions based on the conditions found in a high-level radioactive waste disposal facility located deep underground. In this study, two quartz dissolution experiments were conducted on 1) quartz beads under low-pressure and high-alkalinity conditions and 2) a single quartz crystal under high-pressure and high-alkalinity conditions. Following the experiments, a confocal laser scanning microscope (CLSM) was used to observe the surfaces of experimental samples. Numerical analyses using the finite element method (FEM) were also performed to quantify the deformation of contact area. Quartz dissolution was observed in both experiments. This deformation was due to a concentrated compressive stress field, as indicated by the quartz deformation of the contact area through the FEM analysis. According to the numerical results, a high compressive stress field acted upon the neighboring contact area, which showed a rapid dissolution rate compared to other areas of the sample.

광섬유의 직접구동에 의한 공초점 현미경 (Scanning Confocal Microscope by direct drive of optical fiber)

  • 박두성;류광현;노정은;김종배;권남익
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 2002년도 하계학술발표회
    • /
    • pp.80-81
    • /
    • 2002
  • 편광 방향이 단일 모드의 유지되는 광섬유와 파장이 780nm인 반도체 레이저를 사용하여 간결한 구조의 beam scanning 타입의 공초점 현미경을 구성하였다. 공초점 현미경은 세포내의 생명 현상을 보다 잘 이해 할 수 있는 장비이기 때문에 기존의 현미경으로는 연구할 수 없던 생명현상을 연구할 수 있도록 여러 가지 강력한 연구수단을 제공하고 있다 살아 움직이는 생명체를 관찰할 수 있는 공초점 현미경에서 중요한 것은 속도와 투과 깊이이고, 장기의 표면을 관찰하기 위해서는 크기가 작아야 한다. (중략)

  • PDF

비편광 공초점 현미경 (The Depolarization Scanning Confocal Microscope)

  • 배한성;김종배;류광현;안미화;권남익
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 2003년도 하계학술발표회
    • /
    • pp.132-133
    • /
    • 2003
  • 편광 방향이 단일 모드로 유지되는 광섬유와 파장이 780nm인 반도체 레이저를 사용하여 간결한 구조의 beam scanning 타입의 비편광 공초점 현미경을 구성하였다. 일반적인 공초점 현미경은 세포내의 생명 현상을 보다 잘 이해 할 수 있는 장비이기 때문에 기존의 현미경으로는 연구할 수 없던 생명현상을 연구할 수 있도록 여러 가지 강력한 연구수단을 제공하고 있다. 살아 움직이는 생명체를 관찰할 수 있는 공초점 현미경에서 중요한 것은 속도와 투과 깊이이고, 장기의 표면을 관찰하기 위해서는 크기가 작아야 한다. (중략)

  • PDF

Application of Confocal Laser Scanning Microscopy and Fiber Distribution Index to Study Kenaf Handsheet Properties

  • Pang, Myong-Hyeok;Park, Jong-Moon;Cho, Nam-Seok
    • 펄프종이기술
    • /
    • 제31권3호
    • /
    • pp.54-59
    • /
    • 1999
  • This study was to quantify fiber distributions in thickness direction of kenaf handsheets as a fiber distribution index (FDI) and to analyze the relationship between FDI and the handsheet properties. The images of fiber distribution in z-direction were obtained by Confocal Laser Scanning Microscope (CLSM) and analyzed by image analysis technique. The proposed FDI had a good correlation with high R2 vlaues with various properties of paper, such as apparent density, scattering coefficient , burst index, tear index, tensile index, and folding endurance. The proposed FDI was shown as a good index to quantify paper properties.

  • PDF

Reflection-type Optical Waveguide Index Profiling Technique

  • Youk YoungChun;Kim Dug Young
    • Journal of the Optical Society of Korea
    • /
    • 제9권2호
    • /
    • pp.49-53
    • /
    • 2005
  • We report a new configuration of a reflection-type confocal scanning optical microscope system for measuring the refractive index profile of an optical waveguide. Several improvements on the earlier design are proposed; a light emitting diode (LED) at 650 nm wavelength instead of a laser diode (LD) or He-Ne laser is used as a light source for better index precision, and a simple longitudinal linear scanning and curve fitting techniques are adapted instead of a servo control for maintaining an optical confocal arrangement. We have obtained spatial resolution of 700 nm and an index precision of $2\times10^{-4}$. To verify the system's capability, the refractive index profiles of a conventional multimode fiber and a home-made four-mode fiber were examined with our proposed measurement method.

The effect of using nanoparticles in bioactive glass on its antimicrobial properties

  • Maram Farouk Obeid;Kareim Moustafa El-Batouty;Mohammed Aslam
    • Restorative Dentistry and Endodontics
    • /
    • 제46권4호
    • /
    • pp.58.1-58.8
    • /
    • 2021
  • Objectives: This study addresses the effect of using nanoparticles (np) on the antimicrobial properties of bioactive glass (BAG) when used in intracanal medicaments against Enterococcus faecalis (E. faecalis) biofilms. Materials and Methods: E. faecalis biofilms, grown inside 90 root canals for 21 days, were randomly divided into 4 groups according to the antimicrobial regimen followed (n = 20; BAG-np, BAG, calcium hydroxide [CaOH], and saline). After 1 week, residual live bacteria were quantified in terms of colony-forming units (CFU), while dead bacteria were assessed with a confocal laser scanning microscope. Results: Although there was a statistically significant decrease in the mean CFU value among all groups, the nano-group performed the best. The highest percentage of dead bacteria was detected in the BAG-np group, with a significant difference from the BAG group. Conclusions: The reduction of particle size and use of a nano-form of BAG improved the antimicrobial properties of the intracanal treatment of E. faecalis biofilms

돼지난자의 체외성숙 및 수정시 일어나는 표층과립막세포의 분포변화에 관한 연구 (Cortical Granule Distribution During In Vitro Maturation and Fertilization of Porcine Oocytes)

  • 송상진;권중균;도정태;김남형;이훈택;정길생
    • 한국가축번식학회지
    • /
    • 제20권3호
    • /
    • pp.343-351
    • /
    • 1996
  • 본 연구의 목적은 돼지난자의 체외성숙, 수정 및 단위발생시 일어나는 표층과립의 분포를 살펴보고, 그것들의 역할을 규명해 보고자 실시하였다. 난자의 표층과립은 형광염색을 실시한 후 laser scanning confocal microscope를 이용하여 관찰하거나 transmission electron microscope를 사용하여 관찰하였다. Germinal vesicle 단계의 돼지난자에서는 표층과립은 난자피질에 비교적 두꺼운 형태로 발견되었는데, germinal vesicle breakdown이 일어난 직후 피질 부근으로 표층과립의 움직임이 관찰되었다. Microfilaments의 중합화를 방해하는 cytochalasin B를 처리하였을 때 표층과립의 움직임은 관찰되지 않았다. 무 처리군의 수정 및 단위발생을 유도한 난자에서는 표층과립 내용물들이 위란강내에 균질하게 관찰되었으나, cytochalasin B를 처리한 난자에서는 비정상적인 cortical granule의 움직임을 관장하고 이러한 움직임이 수정시 다정자 침입을 막고 표층과립 반응에 영향을 미치는 것으로 사료된다.

  • PDF

고속 라인 스캔 방식을 이용한 CFRP 가공 홀 표면 및 내부 결함 검사 (Measurements of Defects after Machining CFRP Holes Using High Speed Line Scan)

  • 김택겸;경대수;손운철;박선영
    • 한국정밀공학회지
    • /
    • 제33권6호
    • /
    • pp.459-467
    • /
    • 2016
  • Using a line scan camera and a Galvano mirror, we constructed a high-speed line-scanning microscope that can generate 2D images ($8000{\times}8000pixels$) without any moving parts. The line scanner consists of a Galvano mirror and a cylindrical lens, which creates a line focus that sweeps over the sample. The measured resolutions in the x (perpendicular to line focus) and y (parallel to line focus) directions are both $2{\mu}m$, with a 2X scan lens and a 3X relay lens. This optical system is useful for measuring defects, such as spalling, chipping, delamination, etc., on the surface of carbon fiber reinforced plastic (CFRP) holes after machining in conjunction with adjustments in the angle of LED lighting. Defects on the inner wall of holes are measured by line confocal laser scanning. This confocal method will be useful for analyzing defects after CFRP machining and for fast 3D image reconstruction.

Reconstruction of Collagen Using Tensor-Voting & Graph-Cuts

  • Park, Doyoung
    • 한국정보기술학회 영문논문지
    • /
    • 제9권1호
    • /
    • pp.89-102
    • /
    • 2019
  • Collagen can be used in building artificial skin replacements for treatment of burns and towards the reconstruction of bone as well as researching cell behavior and cellular interaction. The strength of collagen in connective tissue rests on the characteristics of collagen fibers. 3D confocal imaging of collagen fibers enables the characterization of their spatial distribution as related to their function. However, the image stacks acquired with confocal laser-scanning microscope does not clearly show the collagen architecture in 3D. Therefore, we developed a new method to reconstruct, visualize and characterize collagen fibers from fluorescence confocal images. First, we exploit the tensor voting framework to extract sparse reliable information about collagen structure in a 3D image and therefore denoise and filter the acquired image stack. We then propose to segment the collagen fibers by defining an energy term based on the Hessian matrix. This energy term is minimized by a min cut-max flow algorithm that allows adaptive regularization. We demonstrate the efficacy of our methods by visualizing reconstructed collagen from specific 3D image stack.