• Title/Summary/Keyword: Scanning

Search Result 14,120, Processing Time 0.037 seconds

The Development and Evaluation of OMM(On the Machine Measuring) System Using Scanning Probe (Scanning Probe를 이용한 OMM(On the Machine Measuring) 시스템 개발 및 평가)

  • Kim, S.H.;Kim, I.H.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.13 no.10
    • /
    • pp.71-77
    • /
    • 1996
  • This paper describes the development of on the machine measuring(OMM) system which can directlry measure the three dimensional machined dimensilnal accuracy using scanning probe in milling machine. Two algolithms, continuous path(CP) measurement using UC program and CAD data assisted point to point(PTP) measurement, were developed regarding specification of scanning probe. The OMM system was contructed to verify the developed system suing the proposed algorithm, and actually measured three kinds of machined TV shadow mask molds. The developed system was evaluated it's repeatability and compared with the current measurement system of CMM(Coording Measuring Machine) in terms of relative accuracy and time reduction and productivity increase.

  • PDF

Study on Algorithm of High-Speed Scanning System for Railway Vehicle Running Units Using High Performance Camera (고성능 카메라를 이용한 철도차량 주행장치용 고속스케닝시스템 알고리즘에 관한 연구)

  • Huh, Sung Bum;Lee, Hi Sung
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.4
    • /
    • pp.9-14
    • /
    • 2020
  • It is necessary to apply a non-contact high-speed scanning system that can measure in real time in order to prevent the dropping and deformation of the main parts of railway vehicles during high-speed running. Recently, research on a scanning system that detects the deformation state of main parts from a video image taken using a high-performance camera has been actively pursued. In this study, we researched an analysis algorithm of a high-speed scanning system that uses a high-performance camera to monitor the deformation and drop-out state of the main components of the running units equipment in real time.

A Study on the Curvature Correction in Laser Scanner (레이저 주사 장치의 곡률 보정에 관한 연구)

  • Yun, N.I.;Kim, N.;Park, H.K.
    • Proceedings of the Korean Institute of Communication Sciences Conference
    • /
    • 1986.10a
    • /
    • pp.194-197
    • /
    • 1986
  • In this paper, for the curvature correction on the scanning plane in laser scanning system, aberration correction method using holographic optical element is suggested. Holoens is selected as a type of holographic zone plate which has aberration correction property. And hologram recording condition is analyzed to find fo property. This hololens is implemented by computer-generated hologram technique. Laser scanning system is organized using desinged hololens and scanning properties of this system are investigated. Using this method optical system structure in laser scanning system can be simplified satisfying both scan linearity and field flatness.

  • PDF

A Study on the Effective Scanning Trajectory using Manipulator for Underground Object Detection (매니퓰레이터를 이용한 지하 매설물 탐지의 효율적 탐지경로에 관한 연구)

  • Lee, Myung-Chun;Shin, Ho-Cheol;Yoon, Jong-Hoon
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.15 no.1
    • /
    • pp.9-15
    • /
    • 2012
  • This paper shows an effective scanning trajectory for a mine detection device that is one of the mission equipments of unmanned ground vehicle. The mine detection device is composed of a mine-detection sensor, and a 4 DOF manipulator enabling sensor position control. There are three modes that manage the mine detection device: passive, semi-automatic, and automatic. The automatic mode is used the most. This paper suggests a scanning method that makes shape of 8. This method prevents missing target area and enhances scanning speed when the mine detection device scans the ground surface in automatic mode. The suggested method is verified by simulations and experiments.

Manufacturing of SPL system having a large scanning area (대면적 SPL(Scanning Probe Lithography) 시스템 제작)

  • Yoon, Sang-Joon;Kim, Won-Hyo;Seong, Woo-Kyeong;Park, Young-Geun;Hwang, Kyu-Ho;Chung, Kwan-Soo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.699-702
    • /
    • 2004
  • Next generation lithography technologies, such as EBL(Electron Beam Lithography), X-ray lithography, SPL(Scanning Probe Lithography), have been studied widely for getting over line width limitation of photolithography. Among the next generation lithography technologies, SPL has been highlighted because of its high resolution advantage. But is also has problem which are slow processing time and sample size limitation. The purpose of this study is complement of present SPL system. Brand new SPL system was made. SPL test was performed with the system in ultra thin PMMA(polymethlymethacrylate) film.

  • PDF

A Path Generation Algorithm of an Automatic Guided Vehicle Using Sensor Scanning Method

  • Park, Tong-Jin;Ahn, Jung-Woo;Han, Chang-Soo
    • Journal of Mechanical Science and Technology
    • /
    • v.16 no.2
    • /
    • pp.137-146
    • /
    • 2002
  • In this paper, a path generation algorithm that uses sensor scannings is described. A scanning algorithm for recognizing the ambient environment of the Automatic Guided Vehicle (AGV) that uses the information from the sensor platform is proposed. An algorithm for computing the real path and obstacle length is developed by using a scanning method that controls rotating of the sensors on the platform. The AGV can recognize the given path by adopting this algorithm. As the AGV with two-wheel drive constitute a nonholonomic system, a linearized kinematic model is applied to the AGV motor control. An optimal controller is designed for tracking the reference path which is generated by recognizing the path pattern. Based on experimental results, the proposed algorithm that uses scanning with a sensor platform employing only a small number of sensors and a low cost controller for the AGV is shown to be adequate for path generation.

Design and Manufacture of an Electron Detector for Scanning Electron Microscope (주사전자현미경용 전자검출기의 설계 및 제작)

  • Jeon, Jong-Up;Kim, Ji-Won
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.4
    • /
    • pp.53-60
    • /
    • 2008
  • Electron detectors used in scanning electron microscope accept electrons emitted from the specimen and convert them to an electrical signal that, after amplification, is used to modulate the gray-level intensities on a cathode ray tube, producing an image of the specimen. Electron detector is one of the key components dominating the performance of scanning electron microscope so that the development of electron detectors having high performance is indispensable to acquire high quality images using scanning electron microscope. In this paper, we designed and manufactured an electron detector and conducted a couple of image capture experiments using it. In particular, scintillator which generates light photons when it is struck by high-energy electrons was manufactured and experimental studies on the optimization of manufacturing condition was carried out. From experiments to evaluate the performance of our detector, it was verified that the performance of our detector is equivalent to or better than that of the conventional one.

Twin-Image Noise Effects in Optical scanning Holography

  • Doh, Kyu-Bong;Lee, Hwang-Suk
    • Journal of the Optical Society of Korea
    • /
    • v.4 no.1
    • /
    • pp.48-53
    • /
    • 2000
  • In Optical Scanning Holography(OSH), 3-D holographic information of an object is generated by 2-D active optical scanning. The optical scanning beam can be a time-dependent Gaussian apodized Fresnel zone plate. In this technique, the holographic information manifests itself as an electric signal which can be sent to an electron-beam-addressed spatial light modulator for coherent image reconstruction. In this paper, we briefly review optical scanning holography and analyze the resolution achievable with the system. We also present mathmatical expressions of real and virtual images which are responsible for holographic image reconstruction. We then show the twin-image noise effect on the reconstruction in conjunction with the size of the Fresnel zone pattern through computer simulation.

Study on Slice Sensitivity Profile and Reconstruction Resolution on Helical CT System (Helical CT 시스템에 있어 Slice Sensitivity Profile과 Reconstruction Resolution에 관한 연구)

  • Yoon, Han-Sik
    • Journal of radiological science and technology
    • /
    • v.20 no.1
    • /
    • pp.15-20
    • /
    • 1997
  • Unlike conventional CT scan, the helical CT scan uses continuous rotating CT equipment with a slip ring to move the patient's coach at a constant speed while continuously scanning. Slice sensitivity profiles in the Z-position(SSPz) using the conventional X-ray CT have a shape similiar to a rectangular wave, which slightly spreads out into plains below the mountain. However, in the helical CT, with an expansion of the base, the rectangular shape collapses and a mouatain-like shape can be seen. We need to investigate the fellowing factors in helical CT scanning;the ability to scan along the axis of the body, effective slice width, slice shape and the precision of coach velocity, Helical scanning with sprial X-ray track is different from the conventional scanning in terms of the principle of image reconstruction performed. We believe that the problems in helical scanning can be solved by understanding new the special parameters such as the bed moving speed and the interval of image reconstruction.

  • PDF

The Value of Mediastinoscopy in Preoperative Staging of Primary Lung Cancer (원발성 폐암에서 술전 종격동 검사의 의의)

  • Seo, Gang-Seok;Jeon, Sang-Hun;Jang, Bong-Hyeon
    • Journal of Chest Surgery
    • /
    • v.28 no.1
    • /
    • pp.37-41
    • /
    • 1995
  • To determine the role of mediastinoscopy in the preoperative staging of the primary lung cancer, we studied 23 patients from January 1993 to December 1993 and compared the results of mediastinoscopy and computed tomographic scanning with the findings at thoracotomy. Mediastinoscopy was performed in 14 patients when they had larger than 10mm mediastinal nodes at computed tomographic scanning. Six of them were found to have metastatic nodes. Nine patients, who had negative computed tomographic scanning and negative mediastinoscopic results,underwent thoracotomy. One of them was found to have a metastatic mediastinal lymph node. When results from both series of patients were compared, the sensitivity and specificity of computed tomographic scanning showed 83.3% and 47.1% respectively with an accuracy of 56.5%. The results of mediastinoscopy showed that the sensitivity was 85.7%, the specificity was 100% and the accuracy was 95.7%.Because of the low accuracy rate of computed tomographic scanning, a more routine use of mediastinoscopy seems to be justified.

  • PDF