• 제목/요약/키워드: Scanning

검색결과 14,096건 처리시간 0.039초

레이저 주사 경로 생성 및 주사 제어에 관한 연구 (A Study on Generation of Laser Scanning Path and Scanning Control)

  • 최경현;최재원;김대현;도양회;이석희;김성종;김동수
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2004년도 추계학술대회 논문집
    • /
    • pp.1295-1298
    • /
    • 2004
  • Selective Laser Sintering(SLS) method is one of Rapid Prototyping(RP) technologies. It is used to fabricate desirable part to sinter powder and stack the fabricated layer. To develop this SLS machine, it needs effective scanning path and the development of scanning device. This paper shows how to make fast scanning path with respect to scan spacing, laser beam size and scanning direction from 2-dimensional sliced file generated in commercial CAD/CAM software. Also, we develop the scanning device and its control algorithm to precisely follow the generated scanning path. Scanning path affects precision and total machining time of the final fabricated part. Sintering occurs using infrared laser which has high thermal energy. As a result, shrinkage and curling of the fabricated part occurs according to thermal distribution. Therefore, fast scanning path generation is needed to eliminate the factors of quality deterioration. It highly affects machining efficiency and prevents shrinkage and curling by relatively lessening the thermal distribution of the surface of sintering layer. To generate this fast scanning path, adaptive path generation is needed with respect to the shape of each layer, and not simply x, y scanning, but the scanning of arbitrary direction must be enabled. This paper addresses path generation method to focus on fast scanning, and development of scanning system and control algorithm to precisely follow generated path.

  • PDF

표적 검출을 위한 주사방법들의 성능평가 (Evaluation of Scanning Methods for Target Detection)

  • 이문규
    • 제어로봇시스템학회논문지
    • /
    • 제19권1호
    • /
    • pp.72-79
    • /
    • 2013
  • Different scanning methods can be used to detect targets of interest in an image. In this paper, four scanning methods, generalized raster scanning, radial scanning, corner scanning, and random scanning, are considered for the evaluation of their scanning performances. The scanning performance is defined here as the ratio of the average scanning area required to detect a single target to the whole image area. Analytic expressions for the performance of each scanning method are derived. Computational results are given to illustrate the usage and validity of the expressions for the performance comparison.

Layer별 Scanning을 사용한 취약성 분석 방법 (Method of Vulnerability Analysis from Layer Scanning)

  • 천우성;박대우
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2010년도 춘계학술대회
    • /
    • pp.277-280
    • /
    • 2010
  • 네트워크에서 OSI 7 Layer를 기반으로 통신 프로토콜이 구현되고 있고, 인터넷은 TCP/IP Layer를 중심으로 취약성이 발견되고 공격을 당하고 있다. 본 논문은 Scanning 프로그램들을 사용하여 네트워크에 Layer별로 Scanning을 실시하고 그에 따른 취약성을 각 Layer별로 분석한다. 각 Layer별 취약점과 Scanning 프로그램에서 분석 결과들에 대한 차이점을 분석 연구한다. 분석된 결과들에 대한 Scanning 프로그램에 대한 특성을 반영한 Scanning방법에 대한 특장점을 연구하고, 각 Layer별로 보안 대응 방안을 제시한다. 본 연구의 결과는 해커의 공격에 대한 취약성을 분석과 방어를 위한 보안정책 수립에 대한 자료로 활용되어 네트워크의 보안을 강화하는데 기여 할 것이다.

  • PDF

Adaptive Scanning for H.264/AVC Intra Coding

  • Lee, Yung-Lyul;Han, Ki-Hun;Sim, Dong-Gyu;Seo, Jeong-Il
    • ETRI Journal
    • /
    • 제28권5호
    • /
    • pp.668-671
    • /
    • 2006
  • In this letter, an adaptive scanning that improves intra coding efficiency in the H.264/AVC standard is proposed. The proposed adaptive scanning utilizes the prediction directions (modes) that include the horizontal and vertical edge information in a block. Depending on the prediction directions, the proposed method uses three scanning methods: zigzag scanning, horizontal scanning, and vertical scanning. In the proposed method, horizontal and vertical scanning are used in vertical and horizontal prediction modes, respectively, and the normal zigzag scanning in the H.264 standard is used in all other intra prediction modes. The proposed method reduces the bit rate by approximately 2.5% compared with H.264/AVC, without the degradation of video quality.

  • PDF

A Pilot Study of the Scanning Beam Quality Assurance Using Machine Log Files in Proton Beam Therapy

  • Chung, Kwangzoo
    • 한국의학물리학회지:의학물리
    • /
    • 제28권3호
    • /
    • pp.129-133
    • /
    • 2017
  • The machine log files recorded by a scanning control unit in proton beam therapy system have been studied to be used as a quality assurance method of scanning beam deliveries. The accuracy of the data in the log files have been evaluated with a standard calibration beam scan pattern. The proton beam scan pattern has been delivered on a gafchromic film located at the isocenter plane of the proton beam treatment nozzle and found to agree within ${\pm}1.0mm$. The machine data accumulated for the scanning beam proton therapy of five different cases have been analyzed using a statistical method to estimate any systematic error in the data. The high-precision scanning beam log files in line scanning proton therapy system have been validated to be used for off-line scanning beam monitoring and thus as a patient-specific quality assurance method. The use of the machine log files for patient-specific quality assurance would simplify the quality assurance procedure with accurate scanning beam data.

3D 스캐닝 임베디드 시스템 설계 (3D Scanning Embedded System Design)

  • 홍선학;조경순
    • 디지털산업정보학회논문지
    • /
    • 제13권4호
    • /
    • pp.49-56
    • /
    • 2017
  • It is the approach of embedded system design that finds 3D scanning technology to analyze a real object or environment to collect data on its shape and appearance. 3D laser scanning developed during the last half of 20th century in an attempt to accurately recreate the surfaces of various objects. 1960s, early scanners used lights, cameras, and projectors to carry out the scanning in the lacks of performance which encountered many difficulties with shiny, mirroring, or transparent objects. The 3D scanning technology has leveled-up with helpful of embedded software platform research and design. In this paper, First we designed the hardware of laser/camera setup and turntable moving part which is the base of object. Second, we introduced the process of scanning 3D data with software and analyzed the resulting scanned image on the web server. Last, we made the 3D scanning embedded device with 3D printing model and experimented the 3D scanning performance with Raspberry Pi.

모드형상분석을 위한 연속 스캐닝 레이저 도플러 진동측정기 (A Continuous Scanning Laser Doppler Vibrometer for Mode Shape Analysis)

  • 라종필;최지은;박기환;경용수;왕세명;김경석
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 춘계학술대회논문집
    • /
    • pp.274-280
    • /
    • 2002
  • This paper addresses the vibration mode shape measurement technique utilizing a Continuous Scanning Laser Doppler Vibrometer (CSLDV). The continuous scanning capability is added to the conventional discrete Laser Doppler Vibrometer by reflecting the laser beams on the surface of the object using two oscillating mirrors. The bow scanning resulted from the proposed scanning method is eliminated by feedback control. The velocity output signal from the CSLDV is modulated to give the spatial velocity distribution in terms of coefficients which are obtained from the Fast Fourier Transformation of the time dependent velocity signal. Using the Chebyshev series form, the analysis of the vibration mode shape techniques for straight Bine scanning and 2 dimensional scanning are presented and discussed. The performance of the proposed SLDV is presented using the experimental results of the vibration mode shape of a plate

  • PDF

Laser Scanning Path Generation for the Fabrication of Large Size Shape

  • Choi, Kyung-Hyun;Choi, Jae-Won;Doh, Yang-Hoe;Kim, Dong-Soo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.2175-2178
    • /
    • 2005
  • Selective Laser Sintering(SLS) method is one of Rapid Prototyping(RP) technologies. It has been used to fabricate desirable part to sinter powder and stack the fabricated layer. Since the sintering process occurs using infrared laser having high thermal energy, shrinkage and curling of the fabricated part occurs according to thermal distribution. Therefore, the fast scanning path generation is necessary to eliminate the factors of quality deterioration. In case of fabricating larger size parts, the unique scanning device and scanning path generation should be considered. In this paper, the development of SLS machines being capable of large size fabrication(800${\times}$1000${\times}$800 mm, W${\times}$D${\times}$H) will be addressed. The dual laser system and the unique scanning device have been designed and built, which employ CO2 lasers and dynamic 3-axis scanners. The developed system allows scanning a larger planar surface with the desired laser spot size. Also, to generate the fast scanning paths, adaptive path generation is needed with respect to the shape of each layer, and not simply x, y scanning, but the scanning of arbitrary direction should be enabled. To evaluate the suggested method, the complex part will be used for the experiment fabrication.

  • PDF

자기 변형 공진 기구를 이용한 레이저 스캐닝 진동측정기에 관한 연구 (A Study on a Laser Scanning Vibrometer Using a Magnetostrictive Resonant Device)

  • 이정화;류제길;박기환
    • 한국정밀공학회지
    • /
    • 제15권11호
    • /
    • pp.58-66
    • /
    • 1998
  • A low power consuming laser scanning vibrometer is studied for its development. For its optical system, a laser interferometer is constructed to use the Doppler effect. In order to reduce the driving power of the scanning system, a small displacement of the scanning system is produced, which is achieved by using a magnetostrictive actuator. A sufficient rotating angle of the scanning system is obtained by using an amplified displacement from the resonant phenomena of a second order mechanical system composed of a mass and spring. The control of the magnetostrictive actuator using a Terfenol-D is performed without using a feedback system to help reduce the power consumption. The vibration analysis is made for the sinusoidal scanning input to have the space domain information from the time domain of the velocity of a vibration object. As a partial work of development of a tow power consuming laser scanning vibrometer, in this work, a scanning system which has the above features is developed and experimentally investigated. For the purpose of the optical system calibration, the vibration measurement for one axis is presented and the future works are discussed.

  • PDF

Signal increasing method in confocal scanning microscopy in fluorescence mode using curved mirror

  • Kang, Dong-kyun;Seo, Jung-woo;Gweon, Dae-gab
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.99.3-99
    • /
    • 2001
  • In fluorescence mode confocal scanning microscope, level of detected signal is very low. In object scanning type confocal scanning microscope, the additional optical system with objective lens and plane mirror was proposed to increase signal intensity, but there was none for beam scanning type confocal scanning microscope. We propose reflecting optical systems which improve signal intensity in beam scanning type confocal scanning microscope. We choose one of the proposed optical systems and design the optical system, i.e., select optical components and assign distances between the selected components. To design the optical system, we use finite ray tracing method and make cost function to be minimized.

  • PDF