• Title/Summary/Keyword: Scan test

Search Result 870, Processing Time 0.023 seconds

Automatic Boundary Scan Circuits Generator for BIST (BIST를 지원하는 경계 주사 회로 자동 생성기)

  • Yang, Sun-Woong;Park, Jae-Heung;Chang, Hoon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.27 no.1A
    • /
    • pp.66-72
    • /
    • 2002
  • In this paper, we implemented the GenJTAG, a CAD tool, which generates a code of boundary scan circuit supporing a board level testing and d BIST(Built-In Self Test) written in verilog-HDL. A boundary scan circuit code that supports user's own BIST instructions is generated based on the informations from the users. Most CAD tools hardly allow users to add their own BIST instructions because the generated code described in gate-level. But the GenJTAG generates a behavioral boundary scan circuit code so users can easily make a change on the generated code.

Diffuse Hepatic Uptake of $^{99m}Tc$-DPD on Whole Body Bone Scan: The Influence of MRI Contrast (전신 뼈 검사에서 $^{99m}Tc$-DPD의 미만성 간 섭취: MRI 조영제의 영향)

  • Yun, Jong Jun;Jeong, Ji Uk;Hwang, Ju Won
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.57-61
    • /
    • 2012
  • Purpose : The whole body bone scan on nuclear medicine is a widely accepted examination and procedure. However, unusual nonosseous uptake can be observed, which reflects a rare interaction between the radiopharmacceutical and the patient. This study aimed to evaluate the influence of MRI(Magnetic Resonance Imaging) contrast and $^{99m}Tc$-DPD(Dicarboxpropane diphosphonate) on whole body bone scan. Materials and Methods : We analyzed the 982 patients who were examined by $^{99m}Tc$-DPD on whole body bone scan in nuclear medicine department of pusan national university hospital from january to december 2010. All these 982 patients had MRI contrast administration prior to whole body bone scan. We analyzed laboratory test. Results : 46 patients(men 39, women 7) showed diffuse hepatic uptake on whole body bone scan. These uptakes were disappeared on the follow-up whole body bone scan. There were no significant difference of CBC test, liver function tests and renal function tests. Conclusion : The study might be an indirect evidence that diffuse hepatic and splenic uptake of 99mTc-DPD on whole body bone scan after intravenous administration of Gadolinium(Gd) MRI contrast. To perform a precise examination, Gd-contrast agent should be removed from the body before performing a whole body bone scan.

  • PDF

Test Generation for Sequential Circuits Based on Circuit Partitioning (회로 분할에 의한 순차회로의 테스트생성)

  • 최호용
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.35C no.4
    • /
    • pp.30-37
    • /
    • 1998
  • In this paper, we propose a test generation method for large scale sequential circuits based on circuit partitioning to increase the size of circuits that the implicit product machine traversal (IPMT) method can handle. Our method paratitions a circuit under test into subset circuits with only single output, and performs a partial scan design using the state transtition cost that represents a degree of the connectivity of the subset circuit. The IPMT method is applied to the partitioned partial scan circuits in test generation. Experimental results for ISCAS89 benchmark circuits with more thatn 50 flip-flops show that our method has generated test patterns with almost 100% fault coverage at high speed by use of 34%-73% scanned flip-flops.

  • PDF

Analysis of Diffusion Bonded Parts Using Immersed UT Method (수침초음파를 이용한 확산접합부평가)

  • Park, J.C.;Oh, C.S.;Kim, Y.S.;Kim, J.G.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.12 no.3
    • /
    • pp.33-39
    • /
    • 1992
  • This paper presents a summary of the immersion ultrasonic test to analyze the quality of diffusion bonding parts. The most important property of diffusion bonding parts is bonding strength, and that can be obtained by shear test. By comparing among data obtained by ultrasonic test(C-Scan) and those by shear test (bonding strength), these data are shown to be in good relation. Therefore ultrasonic C-Scan test result can be used successfully in quantitative quality control for diffusion bonded parts.

  • PDF

A Clustered Reconfigurable Interconnection Network BIST Based on Signal Probabilities of Deterministic Test Sets (결정론적 테스트 세트의 신호확률에 기반을 둔 clustered reconfigurable interconnection network 내장된 자체 테스트 기법)

  • Song Dong-Sup;Kang Sungho
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.42 no.12
    • /
    • pp.79-90
    • /
    • 2005
  • In this paper, we propose a new clustered reconfigurable interconnect network (CRIN) BIST to improve the embedding probabilities of random-pattern-resistant-patterns. The proposed method uses a scan-cell reordering technique based on the signal probabilities of given test cubes and specific hardware blocks that increases the embedding probabilities of care bit clustered scan chain test cubes. We have developed a simulated annealing based algorithm that maximizes the embedding probabilities of scan chain test cubes to reorder scan cells, and an iterative algorithm for synthesizing the CRIN hardware. Experimental results demonstrate that the proposed CRIN BIST technique achieves complete fault coverage with lower storage requirement and shorter testing time in comparison with the conventional methods.

Performance testing of a FastScan whole body counter using an artificial neural network

  • Cho, Moonhyung;Weon, Yuho;Jung, Taekmin
    • Nuclear Engineering and Technology
    • /
    • v.54 no.8
    • /
    • pp.3043-3050
    • /
    • 2022
  • In Korea, all nuclear power plants (NPPs) participate in annual performance tests including in vivo measurements using the FastScan, a stand type whole body counter (WBC), manufactured by Canberra. In 2018, all Korean NPPs satisfied the testing criterion, the root mean square error (RMSE) ≤ 0.25, for the whole body configuration, but three NPPs which participated in an additional lung configuration test in the fission and activation product category did not meet the criterion. Due to the low resolution of the FastScan NaI(Tl) detectors, the conventional peak analysis (PA) method of the FastScan did not show sufficient performance to meet the criterion in the presence of interfering radioisotopes (RIs), 134Cs and 137Cs. In this study, we developed an artificial neural network (ANN) to improve the performance of the FastScan in the lung configuration. All of the RMSE values derived by the ANN satisfied the criterion, even though the photopeaks of 134Cs and 137Cs interfered with those of the analytes or the analyte photopeaks were located in a low-energy region below 300 keV. Since the ANN performed better than the PA method, it would be expected to be a promising approach to improve the accuracy and precision of in vivo FastScan measurement for the lung configuration.

Evaluation of TOF MR Angiography and Imaging for the Half Scan Factor of Cerebral Artery (유속신호증강효과의 자기공명혈관조영술을 이용한 뇌혈관검사에서 Half Scan Factor 적용한 영상 평가)

  • Choi, Young Jae;Kweon, Dae Cheol
    • Journal of the Korean Magnetics Society
    • /
    • v.26 no.3
    • /
    • pp.92-98
    • /
    • 2016
  • To aim of this study was to assess the full scan and half scan of imaging with half scan factor. Patients without a cerebral vascular disease (n = 30) and were subject to the full scan half scan, and set a region of interest in the cerebral artery from the three regions (C1, C2, C3) in the range of 7 to 8 mm. MIP (maximum intensity projection) to reconstruct the images in signal strength SNR (signal to noise ration), PSNR (peak signal noise to ratio), RMSE (root mean square error), MAE (mean absolute error) and calculated by paired t-test for use by statistics were analyzed. Scan time was half scan (4 minutes 53 seconds), the full scan (6 minutes 04 seconds). The mean measurement range (7.21 mm) of all the ROI in the brain blood vessel, was the SNR of the first C1 is completely scanned (58.66 dB), half-scan (62.10 dB), a positive correlation ($r^2=0.503$), for the second C2 SNR is completely scanned (70.30 dB), half-scan (74.67 dB) the amount of correlation ($r^2=0.575$), third C3 of a complete scan SNR (70.33 dB), half scan SNR (74.64 dB) in the amount of correlation between the It was analyzed with ($r^2=0.523$). Comparative full scan with half of SNR ($4.75{\pm}0.26dB$), PSNR ($21.87{\pm}0.28dB$), RMSE ($48.88{\pm}1.61$), was calculated as MAE ($25.56{\pm}2.2$). SNR is also applied to examine the half-scans are not many differences in the quality of the two scan methods were not statistically significant in the scan (p-value > .05) image takes less time than a full scan was used.

An Efficient Technique to Improve Compression for Low-Power Scan Test Data (저전력 테스트 데이터 압축 개선을 위한 효과적인 기법)

  • Song, Jae-Hoon;Kim, Doo-Young;Kim, Ki-Tae;Park, Sung-Ju
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.43 no.10 s.352
    • /
    • pp.104-110
    • /
    • 2006
  • The huge test data volume, test time and power consumption are major problems in system-on-a-chip testing. To tackle those problems, we propose a new test data compression technique. Initially, don't-cares in a pre-computed test cube set are assigned to reduce the test power consumption, and then, the fully specified low-power test data is transformed to improve compression efficiency by neighboring bit-wise exclusive-or (NB-XOR) scheme. Finally, the transformed test set is compressed to reduce both the test equipment storage requirements and test application time.

Use of Quantitative CT to Predict Postoperative Lung Function (Comparison of Quantitative CT and Perfusion Lung Scan) (폐절제술후의 폐기능 예측에 대한 나선식 정량적 CT의 유용성 (나선식 정량적 CT와 폐관류스캔과의 비교))

  • 이조한
    • Journal of Chest Surgery
    • /
    • v.33 no.10
    • /
    • pp.798-805
    • /
    • 2000
  • Background : the prediction on changes in the lung function after lung surgery would be an important indicator in terms of the operability and postoperative complications. In order to predict the postoperative FEV1 - the commonly used method for measuring changes in lung function- a comparison between the quantitative CT and the perfusion lung scan was made and proved its usefulness. Material and Method : The subjects included 22 patients who received perfusion lung scan and quantitative CT preoperatively and with whom the follow-up of PFT were possibles out of the pool of patients who underwent right lobectomy or right pneumonectomy between June of 1997 and December of 1999. The FEV1 and FVC were calibrated by performing the PFT on each patient and then the predicted FEV1 and FVC were calculated after performing perfusion lung scan and quantitative CT postoperatively. The FEV1 and FVC were calibrated by performing the PFT after 1 week and after 3 momths following the surgery. Results : There was a significant mutual scan and the actual postoperative FEV1 and FVC at 1 week and 3 months. The predicted FEV1 and FVC(pneumonectomy group : r=0.962 and r=0.938 lobectomy group ; r=0.921 and r=913) using quantitative CT at 1 week postoperatively showed a higher mutual relationship than that predicted by perfusion lung scan(pneumonectomy group : r=0.927 and r=0.890 lobectomy group : r=0.910 and r=0.905) The result was likewise at 3 months postoperatively(CT -pneumonectomy group : r=0.799 and r=0.882 lobectomy group : r=0.934 and r=0.932) Conclusion ; In comparison to perfusion lung scan quantitative CT is more accurate in predicting lung function postoperatively and is cost-effective as well. Therefore it can be concluded that the quantitative CT is an effective method of replacing the perfusion lung scan in predicting lung function post-operatively. However it is noted that further comparative analysis using more data and follow-up studies of the patients is required.

  • PDF

Comparison of 99mTc-DMSA Renal Scan and Power Doppler Ultrasonography for the Detection of Acute Pyelonephritis and Vesicoureteral Reflux

  • Bae, Hee Jung;Park, Yong-Hoon;Cho, Jae Ho;Jang, Kyung Mi
    • Childhood Kidney Diseases
    • /
    • v.22 no.2
    • /
    • pp.47-51
    • /
    • 2018
  • Purpose: Urinary tract infection (UTI) is one of the common infectious diseases in children. Several imaging modalities can be used to confirm the presence of acute pyelonephritis (APN). Among them the 99mTcdimercaptosuccinic acid renal scan (DMSA scan) is used as a gold standard for diagnosis. Ultrasonography technology is evolving. Therefore, in this study, we investigated the sensitivity and specificity of Power Doppler ultrasonography (PDU) compared to the results from the previous study. Methods: There were 260 patients included in this study, aged between 1 and 12 months old. The patients were admitted to the Yeungnam University Medical Center between January 2008 and December 2015. All patients underwent both DMSA scan and PDU within 5days of admission. Voiding cystourethrography (VCUG) was performed in 195 patients with abnormal DMSA scan or PDU. Results: The diagnostic sensitivity of APN using PDU was 45.5% and specificity was 85.5% in 260 patients following detection of a defect on DMSA scan that was defined as APN. The diagnostic sensitivity and specificity of PDU for VUR were 65.5 % and 60.1%, respectively. The diagnostic sensitivity and specificity of DMSA scan for VUR were 95.7% and 14.1%, respectively. Conclusion: PDU has a high specificity but low sensitivity, so there are limitations in using it to replace a DMSA scan for the diagnosis of APN in children. DMSA scan and PDU have different sensitivity and specificity in diagnosis of VUR, respectively. Therefore, we suggest that the sensitivity and specificity of each test can be helpful in diagnosing APN and VUR when used in conjunction.