• 제목/요약/키워드: Scan technique

검색결과 600건 처리시간 0.024초

게이트심장혈액풀 스캔과 게이트심장혈액풀 SPECT를 이용한 심실기능의 평가 (Assessment of Ventricular Function Using Gated Blood Pool Scan and Gated Blood Pool SPECT)

  • 박석건
    • 대한핵의학회지
    • /
    • 제39권2호
    • /
    • pp.100-106
    • /
    • 2005
  • Non-invasive evaluation of cardiac function by nuclear medicine technologies are one of the major contribution of nuclear medicine. Gated cardiac blood pool scan was once a novel and robust technique which enabled evaluation of ventricular function. Concept of EKG gating was one of the major breakthrough in nuclear cardiology. According to the evolution of echocardiographic techniques, and as the evaluation of myocardial perfusion by perfusion SPECT became feasible, number of gated blood pool study dong in nuclear medicine laboratory is declining. And recently, evaluation of ventricular function with gated perfusion SPECT further decreased the use of gated blood pool scan. In this article, assessment of ventricular function using gated blood pool scan is discussed including some insight about the role of gated blood pool SPECT.

초음파 비파괴 평가를 위한 협소 타깃의 크랙 사이징 및 검출을 위한 영상 증진기술 (Image Enhancement Techniques for UT - NDE for Sizing and Detection of Cracks in Narrow Target)

  • 이영석;남명우;홍순관
    • 한국산학기술학회논문지
    • /
    • 제8권2호
    • /
    • pp.245-249
    • /
    • 2007
  • 본 논문은 핵발전소의 초음파 비파괴 평가를 수행하기 위하여 핵발전소 설비의 초음파 비파괴 평가시 발생될 수 있는 스펙클 잡음을 억제하고 디컨벌루션 기법을 이용하여 결함의 정확한 위치 및 크기를 추정할 수 있는 영상 처리 기법을 제안하였다. 제안된 방법은 실제 핵발전소의 증기발생기 파이프라인으로 만들어진 시편을 이용하여 영상의 선명도를 확인 할 수 있었다.

  • PDF

연관 규칙 탐사 응용을 위한 한 번 읽기에 의한 최대 크기 빈발항목 추정기법 (Approximation of Frequent Itemsets with Maximum Size by One-scan for Association Rule Mining Application)

  • 한갑수
    • 정보처리학회논문지D
    • /
    • 제15D권4호
    • /
    • pp.475-484
    • /
    • 2008
  • 최근에는 데이터를 획득 및 처리하는 방법의 향상으로 인하여 연속적이고 실시간으로 발생되는 데이터를 처리하는 응용이 증가하고 있다. 그러한 응용에서 연관규칙을 추출하기 위해서는 새로운 방식을 사용하여 빈발항목집합을 찾아내야 한다. 기존의 빈발항목을 발견하는 방식에서는 전체 데이터베이스를 반복적으로 읽으면서 처리해야 한다. 그러나 실시간이고 연속적으로 발생하는 데이터를 처리하는 응용에서는 반복적으로 여러 번 데이터를 읽을 수 없기 때문에 일정 구간의 데이터를 한 번만 읽고 처리해야 한다. 따라서 본 논문에서는 입력되는 데이터 구간을 한 번만 읽고 최대 빈발항목 집합의 크기와 해당 빈발항목을 추정함으로써 필요한 연관규칙탐사를 가능하게 하는 빈발항목 추정 기법을 제안한다.

Verification of the Accuracy of Photogrammetry in 3D Full-Body Scanning -A Case Study for Apparel Applications-

  • Eun Joo Ryu;Lu Zhang;Hwa Kyung Song
    • 한국의류학회지
    • /
    • 제47권1호
    • /
    • pp.137-151
    • /
    • 2023
  • Stationary 3D whole-body scanners generally require 5 to 20 seconds of scanning time and cannot effectively detect armpit and crotch areas. Therefore, this study aimed to analyze the accuracy of a photogrammetric technique using a multi-camera system. First, dimensional accuracy was analyzed using a mannequin scan, comparing the differences between the scan-derived measurements and the direct measurements, with an allowable tolerance of ISO 20685-1:2018. Only 2 of 59 measurement items (ankle height and upper arm circumference, specifically) exceeded the ISO 20685-1:2018 criteria. When compared with the results of the eight stationary whole-body scanners assessed by the literature, the photogrammetric technique was found to have the advantage of scanning the top of the head, armpit, and crotch areas clearly. Second, this study found the photogrammetric technique is suitable for obtaining the body scans because it can minimize the perform scanning, resulting in a reduction of measurement errors due to breathing and uncontrolled movements. The error rate of the photogrammetry method was much lower than that of stationary 3D whole-body scanners.

라인스캔 카메라를 이용한 3차원 정밀 측정 (3D Precision Measurement of Scanning Moire Using Line Scan Camera)

  • 김현주;윤두현;김학일
    • 한국광학회지
    • /
    • 제19권5호
    • /
    • pp.376-380
    • /
    • 2008
  • 본 논문에서는 라인스캔 카메라를 통해 모든 영역의 영상을 획득하는 연구를 제안한다. 이 방법은 기존의 면적 카메라를 이용했던 방법에 비해 투영격자의 이동 횟수를 획기적으로 줄일 수 있으며, 그로 인해 측정시간이 매우 빠르고 측정정밀도도 뛰어난 장점을 가진다. 본 논문의 스캐닝 모아레 측정 방법은 넓은 영역의 3차원 형상 정보를 얻는데 매우 유익하며, 대면적의 대상물 측정 시 일반적으로 사용하는 stitching 기법을 사용할 필요가 없으므로 한번에 전 영역의 3차원 형상의 복원이 가능하여 보다 빠른 속도로 3차원 형상 정보를 얻을 수 있는 효과가 있다. 또한, 투영격자 하나만을 이용한 영사식 모아레 방식을 이용하여 작은 높이 단차를 갖는 물체의 3차원 형상을 복원하고 그 높이를 용이하게 측정 할 수 있다. 본 연구는 양산환경(Mass production)의 웨이퍼 범프 높이 검사 및 FC-CSP나 FC-BGA 범프 높이 검사 등에 활용 할 수 있으며, 실험을 통해 기존의 방법에 비해 투영격자의 이동횟수 및 측정 속도가 향상되었음을 확인하였다.

New Breast Measurement Technique and Bra Sizing System Based on 3D Body Scan Data

  • Oh, Seolyoung;Chun, Jongsuk
    • 대한인간공학회지
    • /
    • 제33권4호
    • /
    • pp.299-311
    • /
    • 2014
  • Objective: The aim of this study was to develop a method for measuring breast size from three-dimensional (3D) body scan image data. Background: Previous bra studies established reference points by directly contacting the subject's naked skin to determine the boundary of the breast. But some subjects were uncomfortable with these types of measurements. This study examined noncontact methods of extracting breast reference points from 3D body scan data that were collected while subjects were wearing standardized soft bras. Method: 3D body scan data of 32 Korean women were analyzed. The subjects were selected from the Size Korea 2010 study. The breast landmarks were identified by graphic analyses of slicing contour lines on 3D body scan data. Results: Three methods determining bra cup size were compared. The M1 and M2 methods determined cup size by calculating the difference between bust girth and under-bust girth. The M3 method determined bra cup size by measuring breast arc length. Conclusion: The researchers proposed an anthropometric bra cup sizing system with the breast arc length (M3 method). It was measured from the geometrically defined landmarks on the 3D body scan slicing contour lines. The new bra cup size was highly correlated with breast depth. Application: The noncontact measuring method used in this study can be applied to the ergonomic studies measuring sensitive body parts.

Spiral scan 초고속 자기공명영상 재구성 알고리즘 (Reconstruction Algorithms for Spiral-scan Echo Planar Imaging)

  • 안창범;김치영;박대준;김휴정;유완석;이윤;오창현;이흥규
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1996년도 추계학술대회
    • /
    • pp.157-160
    • /
    • 1996
  • In this paper, reconstruction algorithms of spiral scan imaging which has been used for ultra fast magnetic resonance imaging have been reviewed, and some simulation results using two different algorithms are reported. Since the trajectory of the spiral scan in k-space is the spiral, reconstruction of the spiral scan is not as straight forward as that used in Fourier imaging technique where the sampling points are usually on the rectangular grids. Originally the reconstruction of the spiral scan imaging was based on the convolution backprojection algorithm modified with a shift term, however, some other reconstruction techniques have also been tried by remapping sampling points from spiral trajectory to Cartesian grids. Some experimental aspects of MR spiral scan imaging will also be addressed.

  • PDF

흉부악성종양(胸部惡性腫瘍)의 방사선치료계획(放射線治療計劃)에 있어서 전산화단층촬영(電算花斷層撮影)의 이용(利用)에 관한 연구(硏究) (Radiotherapy Treatment Planning with Computed Tomography in Malignant Tumors of the Chest-Comparison of various techniques)

  • 이주혁;고경환;하성환;한만청
    • Radiation Oncology Journal
    • /
    • 제1권1호
    • /
    • pp.55-60
    • /
    • 1983
  • To evaluate the usefulness of computed tomography (CT) in radiotherapy treatment planning in malignant tumors of thoracic cage, the computer generated dose distributions were compared between plans based on conventional studies and those based on CT scan. 22 cases of thoracic malignancies, 15 lung cancers and 7 esophageal cancers, diagnosed and treated in Department of Therapeutic Radiology of Seoul National University Hospital from September, 1982 to April, 1983, were analyzed. In lung cancers, dose distribution in plans using AP, PA parallel opposing ports with posterior spinal cord block and in plans using box technique both based on conventional studies were compared with dose distribution using AP, PA and two oblique ports based on CT scan. In esophageal cancers, dose distribution in plans based on conventional studies and those based on CT scans, both using 3 port technique were compared. The results are as follows: 1. Parallel opposing field technique were inadequate in all cases of lung cancers, as portion of primary tumor in 13 of 15 cases and portion of mediastinum in all were out of high dose volume. 2. Box technique was inadequate in 5 of 15 lung cancers as portion of primary tumor was not covered and in every case the irradiated normal lung volume was quite large. 3. Plans based on CT scan were superior to those based on conventional studies as tumor was demarcated better with CT and so complete coverage of tumor and preservation of more normal lung volume could be made. 4. In 1 case of lung cancer, tumor localization was nearly impossible with conventional studies, but after CT scan tumor was more clearly defined and localized. 5. In 1 of 7 esophageal cancers, the radiation volume should be increased for marginal coverage after CT scan. 6. Depth dose correction for tissue inhomogeneity is possible with CT, and exact tumor dose can be calculated. As a result radiotherapy treatment planning based on CT scan has a pteat advantage over that based on conventional studies.

  • PDF

하이브리드 적응적 부호화 알고리즘을 이용한 저전력 스캔 테스트 방식 (Low Power Scan Test Methodology Using Hybrid Adaptive Compression Algorithm)

  • 김윤홍;정준모
    • 한국콘텐츠학회논문지
    • /
    • 제5권4호
    • /
    • pp.188-196
    • /
    • 2005
  • 본 논문에서는 테스트 시간과 전력소모를 감축할 수 있는 새로운 테스트 데이터 압축 및 저전력 스캔 테스트 방법을 제안하였다. 제안된 방법은 수정된 스캔 셀 재배열과 하이브리드 적응적 부호화 방법을 사용하여 scan-in전력과 테스트 데이터 량을 줄였으며 하이브리드 테스트 데이터 압축방법은 Golomb Code와 런길이(run-length) 코드를 테스트 데이터내의 런(run) 길이에 따라서 적응적으로 적용하는 방법이다. 또한 scan-in 전력소모를 최소화하기 위해서 스캔 벡터내의 열 해밍거리를 이용하였다. ISCAS89 벤치마크 회로에 적용하여 실험한 결과, 모든 경우에 있어서 테스트 데이터 및 전력소모를 효율적으로 감소시켰으며 압축률은 17%-26%, 평균 전력소모는 8%-22%, 최고전력소모는 13%-60% 정도의 향상률을 보였다.

  • PDF

연축전지 양극기판의 기계적 특성비교 분석 및 비 파괴 평가기법의 적용 (Material Evaluation of Lead Die-Casted Positive Grid for Battery Using Nondestructive Evaluation Technique)

  • 김희중;이민래;이준현
    • 대한기계학회논문집A
    • /
    • 제26권8호
    • /
    • pp.1709-1718
    • /
    • 2002
  • It is well recognized that improving capacity of positive grid in battery is one of key factors for controlling the expected long lift-time of Battery Energy Storage System(B.E.S.S). Thus it is really important to characterized material properties of positive grid which are mainly affected by fabrication process. In this study, two kinds of positive grids, which were fabricated by gravity casting and die-casting technique were used. Micro-structural observation and tensile test were conducted to investigate the effect of fabrication process of positive grid. Ultrasonic measurement based on pulse-echo method and ultrasonic C-scan technique also performed to correlate ultrasonic velocity with porosity ratio in positive grid. It was found that the porosity ratio of grid fabricated by gravity casting technique increased significantly compared to the grid fabricated by die-casting technique. It was also shown that ulrasonic technique is effective to evaluate the porosity ratio in positive grid.