• 제목/요약/키워드: Scan period

검색결과 285건 처리시간 0.028초

저신장과 비만도의 상관성 분석 - 저신장을 주소로 내원한 환아 236명을 대상으로 (Correlation between Short Stature and Obese Degree - Intended for the Case of 236 Patient in the Name of Short Stature)

  • 이경희;송재철;이재성;곽창규;박선영;한승무;임사비나;신현택
    • 한방비만학회지
    • /
    • 제5권1호
    • /
    • pp.97-107
    • /
    • 2005
  • Objectives The purpose of this study was to investigate correlation between short stature and obese degree. And we also wanted to know the characteristics of patients visited clinic in the name of 'short stature'. Methods Height, body weight, BMI, fat mass, lean body mass, percent body fat were taken intended for 236 patients in the name of short stature. To all the patient questionnaire for growth clinic was drawn up, and ultrasound scan was taken through calcaneous of the right foot. The patients were classified to three groups - short, average, tall group - according to relative position of mid-parental height. It was analysed that the differences between groups in obese degree. Also was investigated correlation between position of short stature and obese degree, and between obese degree and bony maturity. Results & Conclusion 1. The average ages of patients in the name of 'short stature' were $12.69{\pm}3.93$ years old in boys, $10.66{\pm}3.67$ years old in girls. And it seemed to be just before second rapid maturing period. 2. The average BMI were $20.58{\pm}4.07kg/m^2$ in boys, $18.65{\pm}2.85kg/m^2$ in girls, and average percent body fat were $21.99{\pm}7.35%$ in boys, $26.01{\pm}6.35%$ in girls. 3. The numbers of obese children were 34(31.2%) in boys, 19(14.9%) in girls on the basis of BMI. And the numbers were 39(35.8%) in boys, 53(41.7%) in girls on the basis of percent body fat. There was a big difference in case of girls. 4. The numbers of AG(average group) were 48(44.0%) in boys, 60(47.2%) in girls, the numbers of SG(short group) were 35(32.1%) in boys, 31(24.4%) in girls, and numbers of TG(tall group) were 26(23.9%) in boys, 35(27.6%) in girls. 5. There were no significant differences among the groups in BMI, lean body mass, fat mass, percent body fat. Only significant difference in DI(disease index). 6. There were no significant correlation between PH(percent height) and BMI, leanbody mass, fat mass, percent body fat. Only significant correlation in DI(disease index). 7. There were no significant differences between DA(difference between bone age and chronorogical age) and BMI, leanbody mass, percent body fat. Only significant correlation in fat mass.

  • PDF

수종 임플랜트 금속의 내식성에 관한 전기화학적 연구 (AN ELECTROCHEMICAL STUDY ON THE CORROSION RESISTANCE OF THE VARIOUS IMPLANT METALS)

  • 전진영;김영수
    • 대한치과보철학회지
    • /
    • 제31권3호
    • /
    • pp.423-446
    • /
    • 1993
  • Titanium and its alloys are finding increasing use in medical devices and dental implants. The strong selling point of titanium is its resistance to the highly corrosive body fluids in which an implant must survive. This corrosion resistance is due to a tenacious passive oxide or film which exists on the metal's surface and renders it passive. Potentiodynamic polarization measurement is one of the most commonly used electro-chemical methods that have been applied to measure corrosion rates. And the potentiodynamic polarization test supplies detailed information such as open circuit, rupture, and passivation potential. Furthermore, it indicates the passive range and sensitivity to pitting corrosion. This study was designed to compare the corrosion resistance of the commonly used dental implant materials such as CP Ti, Ti-6A1-4V, Co-Cr-Mo alloy, and 316L stainless steel. And the effects of galvanic couples between titanium and the dental alloys were assessed for their useful-ness-as. materials for superstructure. The working electrode is the specimen , the reference electrode is a saturated calomel electrode (SCE), and the counter electrode is made of carbon. In $N_2-saturated$ 0.9% NaCl solutions, the potential scanning was performed starting from -800mV (SCE) and the scan rate was 1 mV/sec. At least three different polarization measurements were carried out for each material on separate specimen. The galvanic corrosion measurements were conducted in the zero-shunt ammeter with an implant supraconstruction surface ratio of 1:1. The contact current density was recorded over a 24-hour period. The results were as follows : 1. In potential-time curve, all specimens became increasingly more noble after immersion in the test solution and reached between -70mV and 50mV (SCE) respectively after 12 hours. 2. The Ti and Ti alloy in the saline solution were most resistant to corrosion. They showed the typical passive behavior which was exhibited over the entire experimental range. Therefore no breakdown potentials were observed. 3. Comparing the rupture potentials, Ti and Ti alloy had the high(:st value (because their break-down potentials were not observed in this study potential range ) followed by Co-Cr-Mo alloy and stainless steel (316L). So , the corrosion resistance of titanium was cecellent, Co-Cr-Mo alloy slightly inferior and stainless steel (316L) much less. 4. The contact current density sinks faster than any other galvanic couple in the case of Ti/gold alloy. 5. Ag-Pd alloy coupled with Ti yielded high current density in the early stage. Furthermore, Ti became anodic. 6. Ti/Ni-Cr alloy showed a relatively high galvanic current and a tendency to increase.

  • PDF

Non Breathe Hold Technique를 이용한 MR 담도계조영술에 대한 고찰 : Prospective Acquisition Correction(PACE)기법과 Respiration Trigger Gating(RTG) 기법의 비교 (A Study on MR Cholangiography using Breathing Hold Target Techniqu by Prospective Acquisition Correction and Respiration Trigger Gating)

  • 구은희;정홍량;임청환;권대철;조정근;이만구
    • 대한디지털의료영상학회논문지
    • /
    • 제10권1호
    • /
    • pp.45-50
    • /
    • 2008
  • Recently, MR Cholangiography used mainly bu controlling of patient's breathing. There is breathing hold techniques to get images within shopt time and gating technique adjusted to respiration cycle for high resolution image. In this study, the aim of this experiment is to know on clinical usefulness compared with PACE and RTG thchniques. This study's period is from 2006 in November to 2007 in January. A total of 21 patients investigated at MAGNETOM Sonata 1.5T (SIEMENS Erlangen) with use of 12ch body coil. MR acquisition protocol used 3D turbo spin echo coronal sequence. Scan parameters applied to potimal setting in use as gating techniques, respectively. Analysis of consuming timing evaluated with rapidness. As analysis of quantity, the common bile duct, gall bladder measured in signal intensities, then these data were calculated by signal to noise ratio and contrast to noise ratio. Qualitative analysis, experienced 2radiologists and 3 RTs were evaluated into 3groups about artifact, accuracy of lesions, sharpness of the common bile duct or gall bladder. As a result of analysis, when compared to PACE, consuming time of the RTG took less than PACE, On both CNRs and SNRs, PACE technique was slightly high values than RTG(p<0.05). Qualitative analysis' results, discrimination of lesions in the common bile duct, gall bladder get a significance level in both RTG and PACE techniques but presence's artifact of breathing and pulsation highly demonstrate in PACE techniques. In conclusion, both PACE and RTG methods at MRCP provided prominently clinical information for the common bile duct, gall bladder. If machines have not limitation with performance, induction of breathing holding also will help getting diagnistic quality.

  • PDF

안와골절 정복술에 사용된 인공삽입물의 전산화단층촬영 추적관찰 (CT Observation of Alloplastic Materials Used in Blow Out Fracture)

  • 이원;강동희
    • Archives of Plastic Surgery
    • /
    • 제37권4호
    • /
    • pp.380-384
    • /
    • 2010
  • Purpose: Distinguishing different types of implants and assessing the position and size of implants by radiologic exam after orbital wall reconstruction is important in determining the surgery outcome and forecasting prognosis. We observed time-dependent density changes in three types of implants (porous polyethylene, resorbing plate and titanium mesh plate) by performing facial bone CT after orbital wall reconstructions. Methods: A total of 32 patients, who had underwent orbital wall fracture surgery from October 2006 to March 2009 and received facial bone CT as outpatients at 1 postoperative year were included in the study. Follow-up facial bone CT was performed on the patients pre- operatively, 1 month post-operatively, and 1 year post-operatively to observe the status of the orbital implants. Medpor $^{(R)}$ (Porex Surgical, Inc., Newnan, Ga.) was used as porous polyethylene and followed-up in 14 cases; for resorbing plate, Synthes mesh plate (Synthes, Oberdorf, Switzerland) was used in the reconstruction, and followed-up in 11 cases; and titanium mesh plate usage was followed-up in 7 cases. Computed tomographic scan (CT) and water's view were done for radiography, and hounsfield unit (HU) was used to compare density of those facial bone CT. Wilcoxon signed rank test was applied to statistically verify measurement difference in each group of hounsfield units. Results: Facial bone CT examination performed in 1 month post-operative showed that the density of porous polyethylene, resorbing plate and titanium mesh plate were -42.07, 105.67 and 539.48 on average, respectively. Among the three types of implants, titanium mesh plate showed the highest density due to its radiopaque feature. Following up the density of three types of implants in CT during 1 year after the orbital wall fracture surgery, the density of porous polyethylene increased in 10.52 House Field Units and the resorbing plate was decreased in 26.87 HouseField Units. There were no significant differences between densities in 1 month post-operatively and 1 year post-operatively in each group ($p{\geq}0.05$). Conclusion: We performed facial bone CT on patients with orbital fractures during follow-up period, distinguishing the types of implants by the different concentration of implant density, and the densities showed little change even at 1 year post-operative. To observe how implant densities change in facial bone CT, further studies with longer follow-up periods should be carried out.

상행대동맥 및 대동맥궁의 수술 (Operation of Ascending Aorta and/or Aortic Arch)

  • 구본원;허동명;전상훈;장봉현;이종태;김규태;이응배
    • Journal of Chest Surgery
    • /
    • 제29권11호
    • /
    • pp.1212-1217
    • /
    • 1996
  • 경북대학교병원 흉부외과에서는 1993년 12월부터 1995년 5월까지 14례(남자 9명, 여자 5명)의 상행대동맥 및 대동맥궁질환을 수술하였으며, 환자들의 나이는 25세 에서 65세로 평균 50.4세였다. 진단은 급성 대동맥 박리가 6례(43%)로 4례는 파열이 되었으며, 상행 대동맥류가 4례(29%)로 1례에서 대동맥궁까지 확장되어 있었고 3례에서 파열이 되었으며, 대동맥 판륜확장이 3례(21%)로 1례에서 파열이 동반되었고, 대동맥궁류가 1례(7%)였다. 전례에서 심초음파와 컴퓨터 단층촬영을 시행하였으며, 혈관촬영은 2례에서 시행하였다. 수술의 적응은 파열 5례, 급성 대동맥 박리 5례, 심한 울혈성 심부전 2례, 진행성의 대동맥판막 폐쇄부전 1례 및 동맥류가 커서 파열의 위험성이 있는 경우 1례였다. 수술은 10례(71%)에서 응급으로 시행하였다. Cabrol 수술 6례, 대동맥궁 치환을 겸한 Cabrol 수술 1례, 변형된 Bentall수술 1례, 상행 대동맥 치환 4례, 대동맥궁 치환 1례 및 대동맥궁 치환을 겸한 상행 대동맥 치환의 경우가 1례였다. 술후 합병증으로는 순환정지를 62분 시행한 환자가 경련을 보였고, 심방세동이 2례, 흉골 열개가 1례 그리고 종격동염이 1례 있었다. 술후 조기사망은 2례(14%)에서 있었으며 각각 과다 출혈과 다발성 장기부전이 원인이었다. 심실 부정맥으로 인한 만기사망이 1례(7%)에서 있었다. 11명의 생존 환자들의 추적관찰기간은 2개월에서 20개월로 전례에서 경과는 양호하였다.

  • PDF

159명의 골다공증성 흉추 및 요추부 골다공증성 추체 압박골절 환자에 대한 경피적 척추성형술 후 치료결과 (Percutaneous Polymethylmethacrylate Vertebroplasty in the Treatment of Osteoporotic Thoracic and Lumbar Vertebral Body Compression Fractures : Outcome of 159 Patients)

  • 이제언;류경식;박춘근;최영근;박춘근;지철;조경석;강준기
    • Journal of Korean Neurosurgical Society
    • /
    • 제30권2호
    • /
    • pp.173-179
    • /
    • 2001
  • Purpose : To assess therapeutic effects of percutaneous polymethylmethacrylate(PMMA) vertebroplasty on the pain caused by osteoporotic thoracic and lumbar vertebral body compression fractures in a large scale of a prospective clinical design, and to determine clinical factors influencing its therapeutic effects. Methods : A prospective clinical study was carried out in 349 vertebral levels of 159 patients between April 1998 and July 1999. The compression fractures were confirmed with bone scan and spine CT, and bone marrow density was measured. Visual analogue scale(VAS) score was used for pre- and post-operative assessments of the pain. All 159 patients were assessed immediately after surgery, and 140 patients of them were followed-up for about 6 months in average. Results : Partial and complete pain relief was sustained immediately after operation in 73%, through follow-up period in 88% of the patients. Pain relief was not proportional to the amount of PMMA or the rate of increase in the height of the compressed vertebral body. It appears that 3 to 6cc of PMMA was proper enough to sustain pain relief. Better clinical improvement was achieved in the patients treated within 6 months after occurrence of vertebral body fracture. The most frequent surgical complication was epidural leakage of PMMA, and the most serious complication was extravertebral leakage into the paravertebral muscles, which appeared to exert the worst influence on the outcome. However, surgery was not required in these patients. Conclusion : Therapeutic effects of PMMA percutaneous vertebroplasty on osteoporotic vertebral body compression fractures were confirmed in a relatively large scale of prospective clinical study. It appears that good outcome can be achieved in patients treated within 6 months after fracture, treated each level with 3 to 6cc of PMMA in amount. without serious complications.

  • PDF

당뇨병성 족부 감염에서 항생제 혼합 시멘트 충전물 사용의 치료 실패 위험 인자 분석 (Risk Factors for the Treatment Failure of Antibiotic-Loaded Cement Spacer Insertion in Diabetic Foot Infection)

  • 박세진;송승철
    • 대한족부족관절학회지
    • /
    • 제23권2호
    • /
    • pp.58-66
    • /
    • 2019
  • Purpose: To evaluate the efficacy of antibiotic-loaded cement spacers (ALCSs) for the treatment of diabetic foot infections with osteomyelitis as a salvage procedure and to analyze the risk factors of treatment failure. Materials and Methods: This study reviewed retrospectively 39 cases of diabetic foot infections with osteomyelitis who underwent surgical treatment from 2009 to 2017. The mean age and follow-up period were $62{\pm}13years$ and $19.2{\pm}23.3months$, respectively. Wounds were graded using the Wagner and Strauss classification. X-ray, magnetic resonance imaging (or bone scan) and deep tissue cultures were taken preoperatively to diagnose osteomyelitis. The ankle-brachial index, toe-brachial index (TBI), and current perception threshold were checked. Lower extremity angiography was performed and if necessary, percutaneous transluminal angioplasty was conducted preoperatively. As a surgical treatment, meticulous debridement, bone curettage, and ALCS placement were employed in all cases. Between six and eight weeks after surgery, ALCS removal and autogenous iliac bone graft were performed. The treatment was considered successful if the wounds had healed completely within three months without signs of infection and no additional amputation within six months. Results: The treatment success rate was 82.1% (n=32); 12.8% (n=5) required additional amputation and 5.1% (n=2) showed delayed wound healing. Bacterial growth was confirmed in 82.1% (n=32) with methicillin-resistant Staphylococcus aureus being the most commonly identified strain (23.1%, n=9). The lesions were divided anatomically into four groups; the largest number was the toes: (1) toes (41.0%, n=16), (2) metatarsals (35.9%, n=14), (3) midfoot (5.1%, n=2), and (4) hindfoot (17.9%, n=7). A significant difference in the Strauss wound score and TBI was observed between the treatment success group and failure group. Conclusion: The insertion of ALCSs can be a useful treatment option in diabetic foot infections with osteomyelitis. Low scores in the Strauss classification and low TBI are risk factors of treatment failure.

치조골이식과 디지털 방법을 활용한 상악 중절치 임플란트 심미 수복 증례 (Aesthetic implant restoration with alveolar bone graft and digital method on maxillary central incisor: a case report)

  • 장한솔;표세욱;김선재;장재승
    • 대한치과보철학회지
    • /
    • 제60권2호
    • /
    • pp.168-174
    • /
    • 2022
  • 상악 전치부의 임플란트 식립 시 치은 퇴축이나 골 결손 문제를 동반하는 경우에는 심미적인 임상 결과를 얻기가 쉽지 않다. 본 증례에서는 상악 우측 중절치에서 순측 치조골판의 소실이 진단되어 발치 후 연조직을 확보한 후에 골 이식을 동반하는 임플란트 식립을 계획하였다. 또한 이상적인 임플란트 식립 위치를 위해 디지털 가이드 수술을 시행하였고, 치조골 결손부가 광범위하기 때문에 하악지에서 자가골 채취 후 이종골과 함께 골유도재생술을 동반하였다. 충분한 임플란트의 골 유착 기간을 거친 뒤 2차 수술 및 인상 채득을 통한 임시 보철물을 제작하였고, 주기적인 외형 조정을 통해 연조직의 형태를 개선하였다. 최종 보철물 제작시에는 양극 처리를 시행한 맞춤형 지대주를 사용하여 자연 치아의 색조를 유도하였고, 구강 스캔을 통하여 임시 보철물의 형태를 재현해 줌으로써 심미적이고 기능적인 지르코니아 보철물을 장착해 주었다.

부가적인 유지구조를 가진 미니 임플란트의 디지털 수복 증례 (Mini-implant with additional retentive structure by using digital method)

  • 황수현;배은빈;조원탁;허중보
    • 대한치과보철학회지
    • /
    • 제60권1호
    • /
    • pp.119-126
    • /
    • 2022
  • 하악 전치부와 같이 골 폭이 좁은 환자에서 미니 임플란트 사용은 기존의 직경 임플란트의 대안으로 보고된다. 그러나, 기존 일체형 미니 임플란트의 사용시 보철물 탈락과 시멘트 사용으로 인한 임플란트 주위염과 같은 합병증의 발생이 보고되고 있다. 최근 미니 임플란트의 유지력 및 안정성을 높이기 위해 상부에 부가적인 유지구조를 가진 일체형 미니 임플란트가 소개되었다. 상부 탄성부를 스프레더로 벌려 줌으로써 지르코니아 보철물 내면의 결합구조와 결합하는 방식을 기반으로 한다. 이에 본 증례는 좁은 폭경의 하악 전치부에서 상부에 결합구조를 가진 일체형 미니 임플란트를 통하여 이러한 합병증을 줄이고자 하였으며 디지털 시스템을 이용하여 전반적인 치료기간을 단축하였다. 두명의 환자에서 유지기능과 심미적인 면에서 만족스러운 임상결과를 얻었기에 본 증례를 보고하고자 한다.

Fe3O4 magnetic nanoparticles provide a novel alternative strategy for Staphylococcus aureus bone infection

  • Youliang, Ren;Jin, Yang;Jinghui, Zhang;Xiao, Yang;Lei, Shi;Dajing, Guo;Yuanyi, Zheng;Haitao, Ran;Zhongliang, Deng;Lei, Chu
    • Advances in nano research
    • /
    • 제13권6호
    • /
    • pp.575-585
    • /
    • 2022
  • Due to its biofilm formation and colonization of the osteocyte-lacuno canalicular network (OLCN), Staphylococcus aureus (S.aureus) implant-associated bone infection (SIABI) is difficult to cure thoroughly, and may occur recurrently subsequently after a long period dormant. It is essential to explore an alternative therapeutic strategy that can eradicate the pathogens in the infected foci. To address this, the polymethylmethacrylate (PMMA) bone cement and Fe3O4 nanoparticles compound cylinder were developed as implants based on their size and mechanical properties for the alternative magnetic field (AMF) induced thermal ablation, The PMMA mixed with optimized 2% Fe3O4 nanoparticles showed an excellent antibacterial efficacy in vitro. It was evaluated by the CFU, CT scan and histopathological staining on a rabbit 1-stage transtibial screw model. The results showed that on week 7, the CFU of infected soft tissue and implants, and the white blood cells (WBCs) of the PMMA+2% Fe3O4+AMF group decreased significantly from their controls (p<0.05). PMMA+2% Fe3O4+AMF group did not observe bone resorption, periosteal reaction, and infectious reactive bone formation by CT images. Further histopathological H&E and Gram Staining confirmed there was no obvious inflammatory cell infiltration, neither pathogens residue nor noticeably burn damage around the infected screw channel in the PMMA+2% Fe3O4+AMF group. Further investigation of nanoparticle distributions in bone marrow medullary and vital organs of heart, liver, spleen, lung, and kidney. There were no significantly extra Fe3O4 nanoparticles were observed in the medullary cavity and all vital organs either. In the current study, PMMA+2% Fe3O4+AMF shows promising therapeutic potential for SIABI by providing excellent mechanical support, and promising efficacy of eradicating the residual pathogenic bacteria in bone infected lesions.