• Title/Summary/Keyword: Scan period

Search Result 285, Processing Time 0.027 seconds

Assessment of the increased calcification of the jaw bone with CT-Scan after dental implant placement

  • Yunus, Barunawaty
    • Imaging Science in Dentistry
    • /
    • v.41 no.2
    • /
    • pp.59-62
    • /
    • 2011
  • Purpose : This study was performed to evaluate the changes of jaw bone density around the dental implant after placement using computed tomography scan (CT-Scan). Materials and Methods : This retrospective study consisted of 30 patients who had lost 1 posterior tooth in maxilla or mandible and installed dental implant. The patients took CT-Scan before and after implant placement. Hounsfield Unit (HU) was measured around the implants and evaluated the difference of HU before and after implant installation. Results : The mean HU of jaw bone was 542.436 HU and 764.9 HU before and after implant placement, respectively (p<0.05). The means HUs for male were 632.3 HU and 932.2 HU and those for female 478.2 HU and 645.5 HU before and after implant placement, respectively (p<0.05). Also, the jaw bone with lower density needed longer period for implant procedure and the increased change of HU of jaw bone was less in the cases which needed longer period for osseointegration. Conclusion : CT-Scan could be used to assess the change of bone density around dental implants. Bone density around dental implant was increased after placement. The increased rate of bone density could be determined by the quality of jaw bone before implant placement.

Design and Implementation of Low-power CSD Considering Beacon Period and Channel Scan Time (비컨 주기와 채널 탐색기간을 고려한 저전력 CSD의 설계 및 구현)

  • Kim, Taek-Hyun;Park, Se-Young;Choi, Hoon;Baek, Yun-Ju
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.16 no.1
    • /
    • pp.50-54
    • /
    • 2010
  • A Container Security Device (CSD) which is different existing RFID Tag strengthens the physical security as mounted inside the container and the information security as encrypts doubly a data. CSD must use the resources efficiently in order to operate with the battery. Therefore, it needs low-power mechanism which repeats the sleep period and channel scan period. However, by adjusting these periods, the trade-off occurs between energy efficiency and network connectivity. In this paper, we implement low-power CSD and resolve this problem by adjusting beacon period and channel scan time. As a result, We guarantee the network connectivity 95% or more and maximum life up to 16 days using common AA batteries.

Study on the Address Discharge Characteristics for the Improvement of the Mis-firing Problem in AC PDP (AC PDP의 오방전 개선을 위한 어드레스 방전 특성 연구)

  • Jeon, Won-Jae;Kim, Dong-Hun;Lee, Seok-Hyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.6
    • /
    • pp.1151-1156
    • /
    • 2009
  • Unstable sustain discharges can occur at the bottom cells of the panel at high temperature. To solve this problem, the wall charge variation during an address period was investigated. A test panel of 7.5 inch XGA level was used and one green cell was measured. In order to realize operating condition equal to that of the bottom cells of 50 inch panel, the addressing stress pulses are applied. It seems that the resultant wall charge loss during address period increased with increase of stress time, temperature, pressure and Xe %. Wall charge loss increases with potential difference between scan electrode and address electrode, therefore wall charge loss can be minimized by the increase of scan voltage during address period.

Suggestion of OSMU Content New Business Market through Development of Integrated Platforms for Software-oriented Tailored Costume Production (소프트웨어 중심의 주문 형 의상제작 융합플랫폼 개발을 통한 OSMU콘텐츠 뉴비즈니스 시장 창출 제안)

  • Jung, Minsoo
    • Journal of Korea Multimedia Society
    • /
    • v.21 no.8
    • /
    • pp.1021-1026
    • /
    • 2018
  • 3D SCAN enables easy human body measurement via a digital method in the process of film costume production which used to be done manually. Software-oriented computer graphic, which integrates 3D SCAN data in the process of manual film costume production, can induce quick and diverse design outcomes. While, 3D PRINT, which integrates computer graphic data in the process of manual film costume production, can automate the process of special costume production using a digital method. Integration of 3D Scan + Computer Graphic + 3D Print using integrated platforms for tailored costume production as developed in this study allows significant reduction of costume production period and costs. It also allows efficient integration of costume production outcomes in various industries related with OSMU contents in particular. In other words, using it, we can create a new business market that integrates multiple areas of film content, drama content and game content.

Development of a Low-cost Lighting System for Line-acan Camera (라인 스캔 카메라를 위한 저가형 시 균일 조명장치 구현)

  • Kim, Hong-Gap;Kim, Hyeong-Seok
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.49 no.5
    • /
    • pp.235-240
    • /
    • 2000
  • A low cost lighting system for line-scan cameras has been developed with 3-phase power. When exposure time of line-scan camera is shorter than fluctuation period of illumination, the average gray value of each acquired 1-D image varies. Detecting defects on the objects's surface under such illuminating environment is very difficult. The proposed lighting system is composed of low-cost fluorescent lights based on 3-phase power. The specially designed lighting pack and the properly selected lighting position enable to get the rippleless lighting. The principle of the proposed lighting system has been explained analytically. The lighting system has been tested for fabric inspection with line-scan camera and it's efficacy has been proved.

  • PDF

The Value of Tc-99m DTPA Diuretic Renography for Assessment of Dilated Upper Urinary Tract in Children (소아의 상부 요관확장증에서 폐쇄 유무 감별에 있어 Tc-99m DTPA 이뇨 신장 신티그램의 유용성)

  • Yang, Ki-Ra;Lim, Gye-Yeon;Sohn, Hyung-Sun;Hahn, Seong-Tae;Lee, Jae-Mun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.1
    • /
    • pp.57-64
    • /
    • 1999
  • Purpose: The purpose of this study was to evaluate the accuracy of Tc-99m DTPA diuretic renal scans in children with dilated upper urinary tract. Materials and Methods: We reviewed diuretic renal scans of 14 pediatric patients (age range: 3 days to 4 years) with unilateral hydronephrosis diagnosed by ultrasonography. Diuretic renal scan was done using Tc-99m DTPA and standardized protocol. In 3 neonates, diuretic renal scans were performed within 1 week and 3-7 months after birth. Results: Six patients required Pyeloplasty and eight were managed conservatively. All 6 patients requiring Pyeloplasty were diagnosed as having ureteropelvic junction obstruction in the diuretic renal scan. In these 6 patients, post-operative renal scans at 3-12 months after surgery were converted to nonobstructive pattern in 5 and a nonfunctioning pattern in 1. In 3 patients who underwent diuretic renal scan within 1 week after birth, nonobstructive patterns of initial scan were converted to obstructive patterns in the follow-up scan. However, all patients with nonobstructive diuretic renal scans performed after the neonatal period did well on serial ultrasonography and showed favorable clinical outcome without progression to obstruction. Conclusion: Tc-99m DTPA diuretic renal scan with standardized protocol is useful in assessing suspected ureteropelvic junction obstruction in children as an initial diagnostic or post-operative follow-up modality. Nonobstructive or indeterminate scan results in the neonatal period requires follow-up scan to monitor development of the obstructive pattern.

  • PDF

$^{99m}TC-MAA$ Pulmonary Perfusion Scan in the Canine Single Luhg Transplant (개에서 시행한 한쪽 이식 폐의 $^{99m}TC-MAA$ 관류스캔)

  • Zeon, S.K.;Ryu, J.G.;Park, C.K.;Yoo, Y.S.;Jung, D.S.;Lee, J.K.
    • The Korean Journal of Nuclear Medicine
    • /
    • v.31 no.3
    • /
    • pp.365-371
    • /
    • 1997
  • The aim of this study is to evaluate the efficiency of the pulmonary perfusion scan(Pp scan) in the experimental animal single lung transplantation. Eight left lung transplanted mongrel dogs were included in this study. The serial Pp scan with 111MBq $^{99m}TC-MAA$ were done at the periods of immediate postoperative period, POD 3 days, and POD 10-14 days and finally autopsy was done in each cases. The transplanted lung perfusion was analysed as a percentage radioactivity of trans planted/native lung(T/N) ratio. The Pp scan of a donor mongrel dog was used as a reference(left/right lung (T/N) ratio 85.2%). The average T/N ratio of all cases on immediate postoperative state(reperfusion injury) : 19.2%, three acute rejections. 12.6%, three bronchial dehiscences 6.1% and two pulmonary thromboses : 2.0%. Two cases showed moderate improvement of reperfusion injury as increasing the T/N ratio in POD 3 days Pp scan. The T/N ratio showed sequentially decreased in six cases. As a conclusion, the Pp scan could be a non-invasive method in the evaluation of the experimental one-lung transplanted mongrel dog.

  • PDF

Impact of the Planning CT Scan Time on the Reflection of the Lung Tumor Motion (전산화단층촬영 주사시간(Scan Time)이 폐종양운동의 재현성에 미치는 영향 분석)

  • Kim Su Ssan;Ha Sung Whan;Choi Eun Kyung;Yi Byong Yong
    • Radiation Oncology Journal
    • /
    • v.22 no.1
    • /
    • pp.55-63
    • /
    • 2004
  • Purpose : To evaluate the reflection of tumor motion according to the planning CT scan time. Material and Methods : A model of N-shape, which moved aiong the longitudinal axis during the ventilation caused by a mechanical ventilator, was produced. The model was scanned by planning CT, while setting the relative CT scan time (T: CT scan time/ventilatory period) to 0.33, 0.50, 0.67, 0.75, 1.00, 1.337, and 1.537. In addition, three patients with non-small cell lung cancer who received stereotactic radiosurgery In the Department of Radiation Oncology, Asan Medical Center from 03/19/2002 to 05/21/2002 were scanned. Slow (10 Premier, Picker, scan time 2.0 seconds per slice) and fast CT scans (Lightspeed, GE Medical Systems, with a scan time of 0.8 second per slice) were peformed for each patient. The magnitude of reflected movement of the N-shaped model was evaluated by measuring the transverse length, which reflected the movement of the declined bar of the model at each slice. For patients' scans, all CT data sets were registered using a stereotactic body frame scale with the gross tumor volumes delineated in one CT image set. The volume and three-dimensional diameter of the gross tumor volume were measured and analyzed between the slow and fast CT scans. Results : The reflection degree of longitudinal movement of the model increased in proportion to the relative CT scan times below 1.00 7, but remained constant above 1.00 T Assuming the mean value of scanned transverse lengths with CT scan time 1.00 T to be $100\%$, CT scans with scan times of 0.33, 0.50, 0.57, and 0.75 T missed the tumor motion by 30, 27, 20, and $7.0\%$ respectively, Slow (scan time 2.0 sec) and Fast (scan time 0.8 sec) CT scans of three patients with longitudinal movement of 3, 5, and 10 mm measured by fluoroscopy revealed the increases in the diameter along the longitudinal axis Increased by 6.3, 17, and $23\%$ in the slow CT scans. Conculsion : As the relative CT scan time increased, the reflection of the respiratory tumor movement on planning CT also Increased, but remained constant with relative CT scan times above 1.00 T When setting the planning CT scan time above one respiration period (>1.00 T), only the set-up margin is needed to delineate the planning target volume. Therefore, therapeutic ratio can be increased by reducing the radiation dose delivered to normal lung tissue.

Improved Waveform during the Addressing Period for the Improvement of the Addressing Time for AC PDPs

  • Lim, Jong-Sik;Kim, Hyun-Seok;Kim, Joon-Yub
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.511-514
    • /
    • 2004
  • ADS(Address Display period Separation) driving method has been considered to be the most appropriate driving technique for AC PDPs. However when the ADS driving method is applied to the high-resolution AC PDP, the required long addressing time often becomes a problem. In this paper, we present a new waveform for reducing the addressing time and for the stable addressing discharge. In this new waveform, a wall charge acceleration pulse is applied to the common electrode right after 80us scan time. In this way, the charge generated by the addressing discharge is accelerated to the electrodes. Experiments using the wall charge acceleration pulse showed that we could stably address an AC PDP with the scan pulses having pulse width of 1 us

  • PDF

A Modified Ramp Reset Waveform for High Contrast Ratio in AC PDPs

  • Kim, Jae-Sung;Yang, Jin-Ho;Ha, Chang-Hoon;Whang, Ki-Woong
    • Journal of Information Display
    • /
    • v.3 no.4
    • /
    • pp.13-18
    • /
    • 2002
  • In general, the background light that is produced during the reset period deteriorates the dark room contrast ratio in AC PDP. In this paper, we propose a modified ramp reset pulse that can reduce the background light to an imperceptible level. In the new reset waveform, the discharges between the scan and sustain electrodes are minimized by applying a positive bias voltage to the sustain electrode and only the weak discharges between the scan and address electrodes are found to occur during the reset period. We also adopted the MgO coated phosphor layer to improve the address voltage margin that was reduced when the bias voltage in the modified ramp reset waveform was applied. As a result, the address voltage margin of 45 V which is the same level of the conventional method was ortained and the dark room contrast ratio was improved up to 7500 : 1.