• 제목/요약/키워드: Scan order

검색결과 586건 처리시간 0.025초

Adaptive Scanning Based on a Morphological Representation of Coefficients for H.264/AVC

  • Choi, Kang-Sun;Ko, Sung-Jea
    • ETRI Journal
    • /
    • 제31권5호
    • /
    • pp.607-609
    • /
    • 2009
  • In this letter, an effective scanning method based on a morphological representation of quantized coefficients is proposed for intra coding in H.264. In the proposed scanning method, the scan order for each block is adaptively reconfigured by exploiting a residual correlation beyond the border of the block. An initial scan order for the current block is determined first by using the pattern of nonzero coefficients in the adjacent block. Then, a complete scan order is obtained by performing the dilation operation at each position within the initial scan order. Experimental results show that the proposed method improves the coding efficiency up to 3.7% compared to the conventional zigzag scanning method.

배선 길이 최소화를 위한 그룹화된 스캔 체인 재구성 방법 (A Grouped Scan Chain Reordering Method for Wire Length Minimization)

  • 이정환;임종석
    • 대한전자공학회논문지SD
    • /
    • 제39권8호
    • /
    • pp.74-83
    • /
    • 2002
  • 대규모 VLSI 시스템을 설계하는 경우 스캔 플립플롭(이하 셀)을 채택한 스캔 테스트 방법을 사용하여 IC 칩의 테스트를 용이하게 한다. 이러한 경우 스캔체인에서의 스캔 셀들의 연결 순서는 물리적 설계과정인 셀들의 배치가 완료된 후 결정하여도 무방하다. 본 논문에서는 이러한 사실을 이용하여 스캔 셀간의 연결선의 길이가 작도록 이들의 순서를 조정하는 방법을 제안한다. 특히 본 논문에서 제안하는 방법은 스캔 셀들이 클럭 도메인별로 그룹화되어 있을 경우 이들의 순서를 결정하기 위하여 새롭게 제시되는 방법으로 기존의 재구성 방법에 비하여 약 13.6%의 배선길이를 절약할 수 있다. 또한, 스캔 셀 순서에 대한 여러 다양한 제약에 대하여 효율적으로 셀들의 순서를 재구성할 수 있다.

레이저빔 직경변화에 대한 광경화성 수지의 경화특성 고찰 (Study of Cure Properties in Photopolymer for Stereolithography using Various Laser Bean Size)

  • 이은덕;김준안;백인환
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2001년도 춘계학술대회 논문집
    • /
    • pp.1089-1092
    • /
    • 2001
  • In the stereolithography process, build parameters are laser power, scan velocity, scan width, bean diameter, layer thickness and so on. These values are determined according to product accuracy and build time. Build time can be reduced by improving of scan velocity, laser power, layer thickness, hatching space and so on. But variation of these parameters influence part accuracy, surface roughness, strength. This paper observed cure properties in various beam diameter. In order to examine these, relationships of scan velocity and cure depth, scan velocity and cure width according to various beam diameter in one scan line are measured. And cure thickness is measured according to beam diameter and scan velocity in scan surface of one layer. For reduction of build time, beam diameter and scan velocity is proposed in stereolithography process.

  • PDF

3 Tesla MRI 시스템에서 초고속 나선주사영상을 위한 고차 shimming (Higher Order Shimming for Ultra-fast Spiral-Scan Imaging at 3 Tesla MRI System)

  • 김판기;임종우;안창범
    • Investigative Magnetic Resonance Imaging
    • /
    • 제11권2호
    • /
    • pp.95-102
    • /
    • 2007
  • 목적: 3.0 Tesla와 같은 고 자장에서 고해상도의 나선주사영상을 얻기 위해서는 주자장을 균일하게 만들어야 한다. 특히, 나선주사영상인 경우 스핀-에코펄스 시퀀스(SE)나 경사자계 에코 펄스 시퀀스(GE)에 비하여 측정 시간이 길기 때문에 주자장이 균일하지 못하다면, off-resonance 현상으로 영상의 blur가 심해진다. 본 연구에서는 빠른 시간 안에 주자장을 균일하게 할 수 있는 고차(Higher-order) shimming방법을 모색했다. 대상 및 방법: 3 Tesla 자기 공명 영상시스템에서 고해상도의 나선주사영상을 얻기에 적합할 정도의 균일한 주자장을 빠른 시간 안에 만들기 위해, 한번의 스캔으로 axial, sagittal, coronal 방향의 불균일도 map을 구할 수 있는 펄스 시퀀스를 제안하였고, 불균일도 map으로부터 spherical harmonics 분석를 통해 shim 코일에 적절한 전류를 인가하여 주자장을 균일하게 만들었다. 결과: 3 Tesla 자기 공명 영상 시스템에서 주자장의 불균일도는 주자장의 크기에 비례하게 된다. 제안한 펄스 시퀀스로 얻은 영상을 이용하여 불균일도 Map을 만들 수 있었고, 이를 spherical harmonics 분석을 하여 2-3회의 고차 shimming으로 불균일한 자장을 균일하게 만들 수 있었다. 제안된 고차 shimming 방법은 전체 영상 영역 뿐만 아니라 선택한 영역에 대해서만 적용도 가능하기 때문에 국부 영역에 대한 고차 shimming이 가능하다. 고차 shimming이 적용되어 주자장이 균일하게 개선된 상태에서 고해상도의 나선주사영상을 얻을 수 있었다. 결론: 3 Tesla 고자장 자기 공명 영상 시스템에서 주자장의 불균일도를 개선하기 위한 펄스 시퀀스와 알고리즘을 통해 주자장의 불균일도를 빠른 시간 안에 개선할 수 있었다. 주자장의 불균일도를 효과적으로 개선함으로써, 고해상도의 나선주사 영상을 얻을 수 있었다.

  • PDF

용접 품질 검사를 위한 초음파 신호의 노이즈 제거 및 C-Scan 영상 형상화 (Noise Reduction and C-Scan Image Shaping of Ultrasonic Signal for Welding Quality Inspection)

  • 김태규;서종덕;이동형;강언욱;권성근
    • 한국멀티미디어학회논문지
    • /
    • 제20권10호
    • /
    • pp.1662-1670
    • /
    • 2017
  • A-Scan NDT equipment is widely used in the industrial field because it is inexpensive and easy to carry but it is necessary to have a skilled inspection specialist who is trained to analyze the waveform of ultrasonic signal. Since the welding quality is judged subjectively by the specialist, there is a problem in the reliability of the quality. In the C-Scan NDT which overcomes the shortcomings of the A-Scan, welding part can be represented in the form of two dimensional image by combining one dimensional ultrasonic waveform so that the quality of welding can be grasped without the help of specialist. In order to develop C-Scan NDT, it is necessary to develop an array type two dimensional transducer and an algorithm to composing image by combining ultrasonic signals generated from a two dimensional transducer. In addition, the noise component must be minimized in the ultrasonic signal in order to display the quality of welding in the form of images. Therefore we propose a method to remove noise component from the ultrasonic wave and construct a two dimensional ultrasonic image.

스플라인 보간법을 적용한 스캔 변환기의 하드웨어 구현 (HARDWARE DESIGN OF A SCAN CONVERTER USING SPLINE INTERPOLATION)

  • 권영민;이범근;정연모
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2000년도 추계종합학술대회 논문집(2)
    • /
    • pp.71-74
    • /
    • 2000
  • The purpose of format conversion is to convert a wide range of personal computer video formats into a target format. Circuits for the conversion have been developed by means of interpolation techniques, such as zero-order interpolation, bilinear interpolation, and bisigmoidal interpolation. This paper proposes a scan converter using cubic splines. The converter was modeled in VHDL on Max+PlusII and implemented with an FPGA chip. The circuit gives much better conversion performance than a scan converter with zero-order or linear interpolation.

  • PDF

스플라인 보간법을 이용한 스캔 변환기 (A Scan Converter Using Spline Interpolation)

  • 이범근;권영민;정연모
    • 한국시뮬레이션학회논문지
    • /
    • 제9권4호
    • /
    • pp.11-23
    • /
    • 2000
  • The purpose of format conversion is to convert a wide range of personal computer video formats into a target format. Circuits for the conversion have been developed by means of interpolation techniques, such as zero-order interpolation, bilinear interpolation, and bisigmoidal interpolation. This paper proposes a scan converter using cubic splines. The converter was modeled in VHDL, simulated on Max+plus Ⅱ , and implemented with an FPGA chip. The circuit gives much better conversion performance than a scan converter with zero-order or linear interpolation techniques according to simulation results and implementation.

  • PDF

스플라인 보간법을 이용한 스캔 변환기 설계 (DESIGN OF A SCAN CONVERTER SUING SPLINE INTERPOLATION)

  • 이범근
    • 한국시뮬레이션학회:학술대회논문집
    • /
    • 한국시뮬레이션학회 2000년도 춘계학술대회 논문집
    • /
    • pp.91-95
    • /
    • 2000
  • The purpose of format conversion is to convert a wide range of personal computer video formats to a target format. Circuits for the conversion has been developed by means of interpolation techniques, such as zero-order interpolation, bilinear interpolation, and bisigmoidal interpolation. This paper proposes a scan converter using cubic splines. The converter was modeled in VHDL on Max+Plus II and implemented with an FPGA cpip. The circuit gives much better conversion performance than a scan converter with zero-order or linear interpolation.

  • PDF

Head & Neck 환자의 방사선 치료시 Metal Artifact의 감소를 위한 Gantry Tilt Scan의 유용성 평가 (Evaluation of using Gantry Tilt Scan to Head & Neck of Patients during Radiation Therapy for Reduction of Metal Artifact)

  • 이충환;윤인하;홍동기;백금문;권경태
    • 대한방사선치료학회지
    • /
    • 제22권2호
    • /
    • pp.85-95
    • /
    • 2010
  • 목 적: 두경부 환자의 CT simulation시 metal artifact가 발생하여 영상의 질 저하와 선량계산의 오차를 유발 할 수 있어 metal artifact를 줄이기 위한 gantry tilt scan의 유용성을 평가하고자 한다. 대상 및 방법: Metal artifact를 줄이기 위하여 $20^{\circ}$ gantry tilt scan하여 $0^{\circ}$로 재구성한 이미지를 획득하였다. AAPM CT performance Phantom을 이용하여 CT number를 비교 분석하고, 아크릴 팬텀을 이용하여 체적의 일치여부를 확인하였다. Metal artifact에 의한 영향을 평가하기 위해 Intensity volume Histogram (IVH)을 통한 CT number의 균질성 및 Dose Volume histogram (DVH)을 통한 선량평가를 시행하였다. 결 과: CT number와 체적의 비교에서는 차이가 0.5% 이하로 나타났다. IVH를 비교 분석결과 gantry tilt scan에서 artifact에 의한 영향이 감소되어 CT number의 균질도가 향상되고, DVH 비교결과는 양쪽 이하선의 0.2~6%의 평균선량 오차를 감소시켰다. 결 론: Head & Neck 방사선치료 시 metal artifact 때문에 체표윤곽의 구별이 어렵고 선량의 오차가 발생한다. Gantry tilt scan을 이용하면 정확한 조직의 묘사가 가능하고, CT number 균질도가 향상되어 선량의 오차를 줄일 수 있었다. Gantry tilt scan 은 Head & Neck 방사선치료 시 정확한 방사선치료에 매우 유용함을 확인하였다.

  • PDF

JPEG이 내장된 ISP를 위한 전력 효율적인 스캔 순서 변환 (Power Efficient Scan Order Conversion for JPEG-Embedded ISP)

  • 박현상
    • 한국산학기술학회논문지
    • /
    • 제10권5호
    • /
    • pp.942-946
    • /
    • 2009
  • ISP와 JPEG 인코더 사이에는 라스터 스캔 순서의 데이터를 $8{\times}8$ 블록 스캔 순서로 변환하는 스캔 순서 변환기가 위치한다. 최근에 단일 라인 메모리를 사용함으로써, 하드웨어 규모를 감축한 스캔 순서 변환기가 제안되었으나 매 사이클마다 기입과 독출 동작을 수행함에 따라서 전체 전력 예산의 대부분을 SRAM이 소모하는 문제점을 야기했다. 본 논문에서는 SRAM에 대한 억세스 빈도를 술이기 위하여 데이터 packer와 unpacker를 스캔 순서 변환 과정에 삽입함으로써, SRAM에 대한 억세스 빈도를 1/8로 줄이는 구조를 제안한다. 실험결과, 제안한 구조를 적용할 경우 SXGA 해 상도에서의 SRAM 전력소모량을 16% 이하로 줄어든다.