• Title/Summary/Keyword: Scan motion

Search Result 159, Processing Time 0.026 seconds

A Theoretical Model for the Analysis of Residual Motion Artifacts in 4D CT Scans (이론적 모델을 이용한 4DCT에서의 Motion Artifact 분석)

  • Kim, Tae-Ho;Yoon, Jai-Woong;Kang, Seong-Hee;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.23 no.3
    • /
    • pp.145-153
    • /
    • 2012
  • In this study, we quantify the residual motion artifact in 4D-CT scan using the dynamic lung phantom which could simulate respiratory target motion and suggest a simple one-dimension theoretical model to explain and characterize the source of motion artifacts in 4DCT scanning. We set-up regular 1D sine motion and adjusted three level of amplitude (10, 20, 30 mm) with fixed period (4s). The 4DCT scans are acquired in helical mode and phase information provided by the belt type respiratory monitoring system. The images were sorted into ten phase bins ranging from 0% to 90%. The reconstructed images were subsequently imported into the Treatment Planning System (CorePLAN, SC&J) for target delineation using a fixed contour window and dimensions of the three targets are measured along the direction of motion. Target dimension of each phase image have same changing trend. The error is minimum at 50% phase in all case (10, 20, 30 mm) and we found that ${\Delta}S$ (target dimension change) of 10, 20 and 30 mm amplitude were 0 (0%), 0.1 (5%), 0.1 (5%) cm respectively compare to the static image of target diameter (2 cm). while the error is maximum at 30% and 80% phase ${\Delta}S$ of 10, 20 and 30 mm amplitude were 0.2 (10%), 0.7 (35%), 0.9 (45%) cm respectively. Based on these result, we try to analysis the residual motion artifact in 4D-CT scan using a simple one-dimension theoretical model and also we developed a simulation program. Our results explain the effect of residual motion on each phase target displacement and also shown that residual motion artifact was affected that the target velocity at each phase. In this study, we focus on provides a more intuitive understanding about the residual motion artifact and try to explain the relationship motion parameters of the scanner, treatment couch and tumor. In conclusion, our results could help to decide the appropriate reconstruction phase and CT parameters which reduce the residual motion artifact in 4DCT.

Design of ECG/PPG Gating System in MRI Environment (MRI용 심전도/혈류 게이팅 시스템 설계)

  • Jang, Bong-Ryeol;Park, Ho-Dong;Lee, Kyoung-Joung
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.1
    • /
    • pp.132-138
    • /
    • 2007
  • MR(magnetic resonance) image of moving organ such as heart shows serious distortion of MR image due to motion itself. To eliminate motion artifacts, MRI(magnetic resonance imaging) scan sequences requires a trigger pulse like ECG(electro-cardiography) R-wave. ECG-gating using cardiac cycle synchronizes the MRI sequence acquisition to the R-wave in order to eliminate image motion artifacts. In this paper, we designed ECG/PPG(photo-plethysmography) gating system which is for eliminating motion artifacts due to moving organ. This system uses nonmagnetic carbon electrodes, lead wire and shield case for minimizing RF(radio-frequency) pulse and gradient effect. Also, we developed a ECG circuit for preventing saturation by magnetic field and a finger plethysmography sensor using optic fiber. And then, gating pulse is generated by adaptive filtering based on NLMS(normalized least mean square) algorithm. To evaluate the developed system, we measured and compared MR imaging of heart and neck with and without ECG/PPG gating system. As a result, we could get a clean image to be used in clinically. In conclusion, the designed ECG/PPG gating system could be useful method when we get MR imaging of moving organ like a heart.

The Effects of Lower Limb Training Using Sliding Rehabilitation Machine on the Foot Motion and Stability in Stroke Patients

  • Lee, Kwan-Sub;Kim, Kyoung;Lee, Na-Kyung
    • The Journal of Korean Physical Therapy
    • /
    • v.27 no.1
    • /
    • pp.24-29
    • /
    • 2015
  • Purpose: The purpose of this study was to investigate the effect of lower limb training using a sliding rehabilitation machine on the foot motion and stability in stroke patients. Methods: Thirty participants were allocated to two groups: Training group (n=15) and Control group (n=15). Subjects in the control group received physical therapy for 30 minutes, five times per week, and those in the training group received lower limb training using a sliding rehabilitation machine for 30 minutes, five times per week, with physical therapy for 30 minutes, five times per week, during a period of six weeks. Heel rotation, hallux stiffness, foot balance, metatarsal load, toe out angle, and subtalar joint flexibility were measured by RS-scan. Results: Significant improvement of the foot motion (hallux stiffness, meta load) and the foot stability (toe out angle, subtalar joint flexibility) was observed in the training group. Conclusion: This study demonstrated that lower limb training using a sliding rehabilitation machine is an effective intervention to improve the foot motion and stability.

The Impact of Spatio-temporal Resolution of GEO-KOMPSAT-2A Rapid Scan Imagery on the Retrieval of Mesoscale Atmospheric Motion Vector (천리안위성 2A호 고속 관측 영상의 시·공간 해상도가 중규모 대기운동벡터 산출에 미치는 영향 분석)

  • Kim, Hee-Ae;Chung, Sung-Rae;Oh, Soo Min;Lee, Byung-Il;Shin, In-Chul
    • Korean Journal of Remote Sensing
    • /
    • v.37 no.5_1
    • /
    • pp.885-901
    • /
    • 2021
  • This paper illustratesthe impact of the temporal gap between satellite images and targetsize in mesoscale atmospheric motion vector (AMV) algorithm. A test has been performed using GEO-KOMPSAT-2A (GK2A) rapid-scan data sets with a temporal gap varying between 2 and 10 minutes and a targetsize between 8×8 and 40×40. Resultsshow the variation of the number of AMVs produced, mean AMV speed, and validation scores as a function of temporal gap and target size. As a results, it was confirmed that the change in the number of vectors and the normalized root-mean squared vector difference (NRMSVD) became more pronounced when smaller targets are used. In addition, it was advantageous to use shorter temporal gap and smaller target size for the AMV calculation in the lower layer, where the average speed is low and the spatio-temporal scale of atmospheric phenomena is small. The temporal gap and the targetsize are closely related to the spatial and temporalscale of the atmospheric circulation to be observed with AMVs. Thus, selecting the target size and temporal gap for an optimum calculation of AMVsrequires considering them. This paper recommendsthat the optimized configuration to be used operationally for the near-real time analysis of mesoscale meteorological phenomena is 4-min temporal gap and 16×16 pixel target size, respectively.

Advanced Abdominal MRI Techniques and Problem-Solving Strategies (복부 자기공명영상 고급 기법과 문제 해결 전략)

  • Yoonhee Lee;Sungjin Yoon;So Hyun Park;Marcel Dominik Nickel
    • Journal of the Korean Society of Radiology
    • /
    • v.85 no.2
    • /
    • pp.345-362
    • /
    • 2024
  • MRI plays an important role in abdominal imaging because of its ability to detect and characterize focal lesions. However, MRI examinations have several challenges, such as comparatively long scan times and motion management through breath-holding maneuvers. Techniques for reducing scan time with acceptable image quality, such as parallel imaging, compressed sensing, and cutting-edge deep learning techniques, have been developed to enable problem-solving strategies. Additionally, free-breathing techniques for dynamic contrast-enhanced imaging, such as extra-dimensional-volumetric interpolated breath-hold examination, golden-angle radial sparse parallel, and liver acceleration volume acquisition Star, can help patients with severe dyspnea or those under sedation to undergo abdominal MRI. We aimed to present various advanced abdominal MRI techniques for reducing the scan time while maintaining image quality and free-breathing techniques for dynamic imaging and illustrate cases using the techniques mentioned above. A review of these advanced techniques can assist in the appropriate interpretation of sequences.

A quantitative analysis of synthetic aperture sonar image distortion according to sonar platform motion parameters (소나 플랫폼의 운동 파라미터에 따른 합성개구소나 영상 왜곡의 정량적 분석)

  • Kim, Sea-Moon;Byun, Sung-Hoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.40 no.4
    • /
    • pp.382-390
    • /
    • 2021
  • Synthetic aperture sonars as well as side scan sonars or multibeam echo sounders have been commercialized and are widely used for seafloor imaging. In Korea related research such as the development of a towed synthetic aperture sonar system is underway. In order to obtain high-resolution synthetic aperture sonar images, it is necessary to accurately estimate the platform motion on which it is installed, and a precise underwater navigation system is required. In this paper we are going to provide reference data for determining the required navigation accuracy and precision of navigation sensors by quantitatively analyzing how much distortion of the sonar images occurs according to motion characteristics of the platform equipped with the synthetic aperture sonar. Five types of motions are considered and normalized root mean square error is defined for quantitative analysis. Simulation for error analysis with parameter variation of motion characteristics results in that yaw and sway motion causes the largest image distortion whereas the effect of pitch and heave motion is not significant.

Optimizing Imaging Conditions in Digital Tomosynthesis for Image-Guided Radiation Therapy (영상유도 방사선 치료를 위한 디지털 단층영상합성법의 촬영조건 최적화에 관한 연구)

  • Youn, Han-Bean;Kim, Jin-Sung;Cho, Min-Kook;Jang, Sun-Young;Song, William Y.;Kim, Ho-Kyung
    • Progress in Medical Physics
    • /
    • v.21 no.3
    • /
    • pp.281-290
    • /
    • 2010
  • Cone-beam digital tomosynthesis (CBDT) has greatly been paid attention in the image-guided radiation therapy because of its attractive advantages such as low patient dose and less motion artifact. Image quality of tomograms is, however, dependent on the imaging conditions such as the scan angle (${\beta}_{scan}$) and the number of projection views. In this paper, we describe the principle of CBDT based on filtered-backprojection technique and investigate the optimization of imaging conditions. As a system performance, we have defined the figure-of-merit with a combination of signal difference-to-noise ratio, artifact spread function and floating-point operations which determine the computational load of image reconstruction procedures. From the measurements of disc phantom, which mimics an impulse signal and thus their analyses, it is concluded that the image quality of tomograms obtained from CBDT is improved as the scan angle is wider than 60 degrees with a larger step scan angle (${\Delta}{\beta}$). As a rule of thumb, the system performance is dependent on $\sqrt{{\Delta}{\beta}}{\times}{\beta}^{2.5}_{scan}$. If the exact weighting factors could be assigned to each image-quality metric, we would find the better quantitative imaging conditions.

A design and implementation of high-performance 2D PE architecture in H.264 Motion Estimation (H.264 움직임 추정의 고속 2D PE 아키텍쳐 설계 및 구현)

  • Lee, Kyung-Ho;Kong, Jin-Hyeung
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.405-406
    • /
    • 2008
  • This paper presents a high performance 2D PE architecture for H.264 Motion Estimation(ME). While existing 2D PE architectures reuse the overlapped data of adjacent search windows scanned in 1 or 3-way, the new architecture scan adjacent windows and multiple paths instead of single raster and zigzag scanning of adjacent windows in 4 way(up,down,left,right). By reducing the redundant access factor by 1.4, the new 4-way search window improve the memory bandwidth by 70-58% compared with 1/3-way search window. With Altera Stratix-III implementation, the high performance 2D PE architecture deals with SD ($720{\times}480$) video of 2 reference frame, $48{\times}48$ search area and $16{\times}16$ macroblock by 30fps at 97.1MHz.

  • PDF

Emerging Trends in 3D Technology Adopted in Apparel Design Research and Product Development (의류학 연구 및 패션산업 현장에 도입되고 있는 3D 기술동향 및 적용사례 고찰)

  • Park, Huiju;Koo, Helen
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.42 no.1
    • /
    • pp.195-209
    • /
    • 2018
  • This study reviewed emerging trends in 3D technology adopted in apparel design research and product development for rapid prototyping and effective evaluation of product performance. Based on a literature review, the authors discussed technical advantages, practical merits and limitations, applications, and on-going developmental efforts of the following methodologies focusing on 3D body scanning and 3D motion capture, and 3D virtual fit simulation technologies. Such data-driven technical approaches observed in recent apparel design research and industry practice are expected to increasingly be adopted in the field to improve consumers' satisfaction with functionality, aesthetics, and comfort of a wide range of apparel products that include daily wear, sport apparel and protective clothing.

Common-path Optical Coherence Tomography for Biomedical Imaging and Sensing

  • Kang, Jin-U.;Han, Jae-Ho;Liu, Xuan;Zhang, Kang
    • Journal of the Optical Society of Korea
    • /
    • v.14 no.1
    • /
    • pp.1-13
    • /
    • 2010
  • This paper describes a development of a fiber optic common-path optical coherence tomography (OCT) based imaging and guided system that possess ability to reliably identify optically transparent targets that are on the micron scale; ability to maintain a precise and safe position from the target; ability to provide spectroscopic imaging; ability to imaging biological target in 3-D. The system is based on a high resolution fiber optic Common-Path OCT (CP-OCT) that can be integrated into various mini-probes and tools. The system is capable of obtaining >70K A-scan per second with a resolution better than $3\;{\mu}m$. We have demonstrated that the system is capable of one-dimensional real-time depth tracking, tool motion limiting and motion compensation, oxygen-saturation level imaging, and high resolution 3-D images for various biomedical applications.