• Title/Summary/Keyword: Scan motion

Search Result 160, Processing Time 0.025 seconds

Complete mouth rehabilitation, using jaw motion tracking and double scan technique in a patient with osteoarthrosis: a case report (골관절증 환자에서 하악 운동 추적 장치와 이중 스캔 기법을 활용한 완전 구강 회복 증례)

  • Seo-Kyung Jeong;Jai-Young Koak;Seong-Joo Heo;Seong-Kyun Kim;Ji-Man Park
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.62 no.1
    • /
    • pp.82-94
    • /
    • 2024
  • This is a case report of complete mouth rehabilitation in a patient with generalized attrition and loss of posterior support. After analyzing the condition of the temporomandibular joint, multiple implants were placed to restore collapsed occlusion. Fixture/abutment level intraoral scanning was done instead of using conventional impression materials which entail multiple bite registration for cross-mounting. A 'jaw motion tracking'device, 'digital face-bow transfer', and 'double scan technique' which enables duplicating temporary restoration to definitive restoration were used to fabricate definitive prostheses. By using various digital techniques, complete mouth rehabilitation was done with minimal chair time in a patient with unstable occlusion.

A Fast Full-Search Motion Estimation Algorithm using Adaptive Matching Scans based on Image Complexity (영상 복잡도와 다양한 매칭 스캔을 이용한 고속 전영역 움직임 예측 알고리즘)

  • Kim Jong-Nam
    • Journal of KIISE:Software and Applications
    • /
    • v.32 no.10
    • /
    • pp.949-955
    • /
    • 2005
  • In this Paper, we propose fast block matching algorithm by dividing complex areas based on complexity order of reference block and square sub-block to reduce an amount of computation of full starch(FS) algorithm for fast motion estimation, while keeping the same prediction quality compared with the full search algorithm. By using the fact that matching error is proportional to the gradient of reference block, we reduced unnecessary computations with square sub-block adaptive matching scan based image complexity instead of conventional sequential matching scan and row/column based matching scan. Our algorithm reduces about $30\%$ of computations for block matching error compared with the conventional partial distortion elimination(PDE) algorithm without any prediction quality, and our algorithm will be useful in real-time video coding applications using MPEG-4 AVC or MPEG-2.

A decoupling controller design for the seeker scan loop with a spin-stabilized platform (자전 안정화형 탐색기 주사루프의 비연성 제어기 설계)

  • 유인억;이상정
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.35S no.5
    • /
    • pp.35-41
    • /
    • 1998
  • This paper presents a decoupling controller of the missile seeker scan loop with a spin-stabilized platform. A precise seeker motion with respect to the scan command is essential for the higher acquisition probability of the target. As the seeker scan loop is a deeply cross-coupled two input two output system, an accurate pointing or scanning for each axis to the target is very difficult, even though provided with the help of a high performance controller. When a decoupling control is applied to the seeker scan loop, the cross-coupling between two axes can be reduced to a remarkable amount. As a low order of controller is required for the real time operation, a PI controller with decoupling filter is suggested and compared with other controllers. A linearized dynamic model of seeker scan loop is used and validated through the comparison of experimental results of step responses.

  • PDF

Evaluation of Paradoxical Septal Motion Following Cardiac Surgery with Gated Cardiac Blood Pool Scan (방사성동위원소 심혈관촬영술을 이용한 개심술 전후의 역행성 심실중격운동에 관한 연구)

  • Shin, Seong-Hae;Chung, June-Key;Lee, Myung-Chul;Cho, Bo-Youn;Koh, Chang-Soon;Suh, Kyung-Phil
    • The Korean Journal of Nuclear Medicine
    • /
    • v.19 no.1
    • /
    • pp.67-72
    • /
    • 1985
  • The development of paradoxical interventricular septal motion is a common consequence of cardiopulmonary bypass operation. The reason for this postoperative abnormal septal motion is not clear. 41 patients were studied preoperatively and postoperatively with radionuclide blood pool scan to evaluate the frequency of development of paradoxical septal motion with right ventricular volume overload before surgery and the frequency of development of paradoxical septal motion after cardiac surgery with cardiopulmonary bypass, and to evaluate the change of EF related to the development of paradoxical septal motion after cardiac surgery. The results were as follows; 1) 7 of 41 patients with right ventricular volume overload(that is 17%) showed paradoxical septal motion before surgery. But 13 of 34 patients(that is 42%) had paradoxical septal motion after cardiac surgery with cardiopulmonary bypass. So open heart surgery with cardiopulmonary bypass related the development of paradoxical septal motion after surgery. 2) EF significantly decreased in patients who developed paradoxical septal motion after surgery, whereas the EF did not change in the patients who retained normal interventricular septal motion after surgery. So paradoxical septal motion usually reflected some diminution of left ventricular function, immediately after cardiac surgery.

  • PDF

Adaptive Matching Scan Algorithm Based on Gradient Magnitude and Sub-blocks in Fast Motion Estimation of Full Search (전영역 탐색의 고속 움직임 예측에서 기울기 크기와 부 블록을 이용한 적응 매칭 스캔 알고리즘)

  • 김종남;최태선
    • Proceedings of the IEEK Conference
    • /
    • 1999.11a
    • /
    • pp.1097-1100
    • /
    • 1999
  • Due to the significant computation of full search in motion estimation, extensive research in fast motion estimation algorithms has been carried out. However, most of the algorithms have the degradation in predicted images compared with the full search algorithm. To reduce an amount of significant computation while keeping the same prediction quality of the full search, we propose a fast block-matching algorithm based on gradient magnitude of reference block without any degradation of predicted image. By using Taylor series expansion, we show that the block matching errors between reference block and candidate block are proportional to the gradient magnitude of matching block. With the derived result, we propose fast full search algorithm with adaptively determined scan direction in the block matching. Experimentally, our proposed algorithm is very efficient in terms of computational speedup and has the smallest computation among all the conventional full search algorithms. Therefore, our algorithm is useful in VLSI implementation of video encoder requiring real-time application.

  • PDF

Alternative analytic method for computing mean observation time in space-telescopes with spin-precession attitude motion

  • Juan, Bermejo-Ballesteros;Javier, Cubas;Francisco, Casas;Enrique, Martinez-Gonzalez
    • Advances in aircraft and spacecraft science
    • /
    • v.9 no.5
    • /
    • pp.449-462
    • /
    • 2022
  • Space-telescopes placed in the Sun-Earth second Lagrange point (L2) observe the sky following a scan strategy that is usually based on a spin-precession motion. Knowing which regions of the sky will be more observed by the instrument is important for the science operations and the instrument calibration. Computing sky observation parameters numerically (discretizing time and the sky) can consume large amounts of time and computational resources, especially when high resolution isrequired.This problem becomesmore critical if quantities are evaluated at detector level instead of considering the instrument entire Field of View (FoV). In previous studies, the authors have derived analytic solutions for quantities that characterize the observation of each point in the sky in terms of observation time according to the scan strategy parameters and the instrument FoV. Analytic solutions allow to obtain results faster than using numerical methods as well as capture detailed characteristics which can be overseen due to discretization limitations. The original approach is based on the analytic expression of the instrument trace over the sky. Such equations are implicit and thusrequiresthe use of numeric solversto compute the quantities.In this work, a new and simpler approach for computing one ofsuch quantities(mean observation time) is presented.The quantity is first computed for pure spin motion and then the effect of the spin axis precession is incorporated under the assumption that the precession motion is slow compared to the spin motion.In this sense, this new approach further simplifies the analytic approach, sparing the use of numeric solvers, which reduces the complexity of the implementation and the computing time.

Factor Analysis of Decreased Score on Coronary Artery Calcium Score (관상동맥 석회화점수 감소 요인 분석)

  • Shim, Jae-Goo;Kim, Yon-Min;Kim, Jin-Woo
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.4
    • /
    • pp.285-290
    • /
    • 2016
  • The purpose of our study was to retrospectively evaluate the cause of a decreased calcium score of follow-up studies on coronary artery calcium scores (CACs) computed tomography (CT). The subjects were healthy 100 people(85 males $60.6{\pm}6.9$ years, 15 females $67.2{\pm}7.3$ years). The subjects decreased CACs were divided into 4 subgroups depending on Agatston classification, minimal (1-10), mild (11-100), moderate (101-400), severe (400<). As a result of decreased CACs were scan location disagreement 51%, motion artifact 26%, equipment changes 14%, operator mistakes 5%, input miss 2%, image loss 1%, arrhythmia 1%. In the mild group, the most common decreased CACs were 49 people. In the minimal group, the most significant variation reduction has occurred to 6 people. Scan location disagreement was considered a partial volume effects due to the scan starting position. It showed less than 100 CACs a high variation (19.7%) in more than 100 CACs, a lower variation (2.2%), these could be seen that the variation range is different that can be tolerated according to the calcification score. Motion artifact factor was found in 26%, which is so closely related to the preceding tests that affect the higher heart rate like this pulmonary function test, exercise stress test.

A study on the real time obstacle recognition by scanned line image (스캔라인 연속영상을 이용한 실시간 장애물 인식에 관한 연구)

  • Cheung, Sheung-Youb;Oh, Jun-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.21 no.10
    • /
    • pp.1551-1560
    • /
    • 1997
  • This study is devoted to the detection of the 3-dimensional point obstacles on the plane by using accumulated scan line images. The proposed accumulating only one scan line allow to process image at real time. And the change of motion of the feature in image is small because of the short time between image frames, so it does not take much time to track features. To obtain recursive optimal obstacles position and robot motion along to the motion of camera, Kalman filter algorithm is used. After using Kalman filter in case of the fixed environment, 3-dimensional obstacles point map is obtained. The position and motion of moving obstacles can also be obtained by pre-segmentation. Finally, to solve the stereo ambiguity problem from multiple matches, the camera motion is actively used to discard mis-matched features. To get relative distance of obstacles from camera, parallel stereo camera setup is used. In order to evaluate the proposed algorithm, experiments are carried out by a small test vehicle.

Impact of the Planning CT Scan Time on the Reflection of the Lung Tumor Motion (전산화단층촬영 주사시간(Scan Time)이 폐종양운동의 재현성에 미치는 영향 분석)

  • Kim Su Ssan;Ha Sung Whan;Choi Eun Kyung;Yi Byong Yong
    • Radiation Oncology Journal
    • /
    • v.22 no.1
    • /
    • pp.55-63
    • /
    • 2004
  • Purpose : To evaluate the reflection of tumor motion according to the planning CT scan time. Material and Methods : A model of N-shape, which moved aiong the longitudinal axis during the ventilation caused by a mechanical ventilator, was produced. The model was scanned by planning CT, while setting the relative CT scan time (T: CT scan time/ventilatory period) to 0.33, 0.50, 0.67, 0.75, 1.00, 1.337, and 1.537. In addition, three patients with non-small cell lung cancer who received stereotactic radiosurgery In the Department of Radiation Oncology, Asan Medical Center from 03/19/2002 to 05/21/2002 were scanned. Slow (10 Premier, Picker, scan time 2.0 seconds per slice) and fast CT scans (Lightspeed, GE Medical Systems, with a scan time of 0.8 second per slice) were peformed for each patient. The magnitude of reflected movement of the N-shaped model was evaluated by measuring the transverse length, which reflected the movement of the declined bar of the model at each slice. For patients' scans, all CT data sets were registered using a stereotactic body frame scale with the gross tumor volumes delineated in one CT image set. The volume and three-dimensional diameter of the gross tumor volume were measured and analyzed between the slow and fast CT scans. Results : The reflection degree of longitudinal movement of the model increased in proportion to the relative CT scan times below 1.00 7, but remained constant above 1.00 T Assuming the mean value of scanned transverse lengths with CT scan time 1.00 T to be $100\%$, CT scans with scan times of 0.33, 0.50, 0.57, and 0.75 T missed the tumor motion by 30, 27, 20, and $7.0\%$ respectively, Slow (scan time 2.0 sec) and Fast (scan time 0.8 sec) CT scans of three patients with longitudinal movement of 3, 5, and 10 mm measured by fluoroscopy revealed the increases in the diameter along the longitudinal axis Increased by 6.3, 17, and $23\%$ in the slow CT scans. Conculsion : As the relative CT scan time increased, the reflection of the respiratory tumor movement on planning CT also Increased, but remained constant with relative CT scan times above 1.00 T When setting the planning CT scan time above one respiration period (>1.00 T), only the set-up margin is needed to delineate the planning target volume. Therefore, therapeutic ratio can be increased by reducing the radiation dose delivered to normal lung tissue.

A Content-Based Motion Adaptive DeInterlacing Technique (콘텐츠 기반 움직임 적응형 디인터레이싱 기법)

  • Kim, Min-Hwan;Lee, Chang-Woo;Lee, Seong-Won
    • Journal of Broadcast Engineering
    • /
    • v.15 no.6
    • /
    • pp.791-802
    • /
    • 2010
  • Recent prevalence of progressive scan display such as LCD TV demands the quality improvement of existing deinterlacing techniques that convert interlaced scan images including HDTV broadcasting to progressive scan images. In this paper, we proposea motion adaptive deinterlacing technique which can be used for spatial methods, temporal methods, and the spatial-temporal methods can be used for the deinterlacing techniques selectively based on the threshold values calculated by the statistics of motion in the video contents. We also propose an improved spatial deinterlacing technique that adaptively use M-ELA and DOI based on the slant of edges that are obtained by Sobel operation. The improved picture quality of the proposed algorithm is confirmed by objective and subjective quality tests on many test image sequences.