• Title/Summary/Keyword: Scan motion

Search Result 160, Processing Time 0.026 seconds

The Value of Computed Tomography Scan in Three-dimensional Planning and Intraoperative Navigation in Primary Total Hip Arthroplasty

  • Fabio Mancino;Andreas Fontalis;Ahmed Magan;Ricci Plastow;Fares S. Haddad
    • Hip & pelvis
    • /
    • v.36 no.1
    • /
    • pp.26-36
    • /
    • 2024
  • Total hip arthroplasty (THA) is a frequently performed procedure; the objective is restoration of native hip biomechanics and achieving functional range of motion (ROM) through precise positioning of the prosthetic components. Advanced three-dimensional (3D) imaging and computed tomography (CT)-based navigation are valuable tools in both the preoperative planning and intraoperative execution. The aim of this study is to provide a thorough overview on the applications of CT scans in both the preoperative and intraoperative settings of primary THA. Preoperative planning using CT-based 3D imaging enables greater accuracy in prediction of implant sizes, leading to enhancement of surgical workflow with optimization of implant inventory. Surgeons can perform a more thorough assessment of posterior and anterior acetabular wall coverage, acetabular osteophytes, anatomical landmarks, and thus achieve more functional implant positioning. Intraoperative CT-based navigation can facilitate precise execution of the preoperative plan, to attain optimal positioning of the prosthetic components to avoid impingement. Medial reaming can be minimized preserving native bone stock, which can enable restoration of femoral, acetabular, and combined offsets. In addition, it is associated with greater accuracy in leg length adjustment, a critical factor in patients' postoperative satisfaction. Despite the higher costs and radiation exposure, which currently limits its widespread adoption, it offers many benefits, and the increasing interest in robotic surgery has facilitated its integration into routine practice. Conducting additional research on ultra-low-dose CT scans and examining the potential for translation of 3D imaging into improved clinical outcomes will be necessary to warrant its expanded application.

The Study of New Reconstruction Method for Brain SPECT on Dual Detector System (Dual detector system에서 Brain SPECT의 new reconstruction method의 연구)

  • Lee, Hyung-Jin;Kim, Su-Mi;Lee, Hong-Jae;Kim, Jin-Eui;Kim, Hyun-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.57-62
    • /
    • 2009
  • Purpose: Brain SPECT study is more sensitive to motion than other studies. Especially, when applying 1-day subtraction method for Diamox SPECT, it needs shorter study time in order to prevent reexamination. We were required to have new study condition and analysing method on dual detector system because triple head camera in Seoul National University Hospital is to be disposed. So we have tried to increase image quality and make the dual and triple head to have equivalent study time by using a new analysing program. Materials and Methods: Using IEC phantom, we estimated contrast, SNR and FWHM. In Hoffman 3D brain phantom which is similar with real brain, we were on the supposition that 5% of injected doses were distributed in brain tissue. To compare with existing FBP method, we used fan-beam collimator. And we applied 15 sec, 25 sec/frame for each SEPCT studies using LEHR and LEUHR. We used OSEM2D and Onco-flash3D reconstruction method and compared reconstruction methods between applied Gaussian post-filtering 5mm and not applied as well. Attenuation correction was applied by manual method. And we did Brain SPECT to patient injected 15 mCi of $^{99m}Tc$-HMPAO according to results of Phantom study. Lastly, technologist, MD, PhD estimated the results. Results: The study shows that reconstruction method by Flash3D is better than exiting FBP and OSEM2D when studied using IEC phantom. Flowing by estimation, when using Flash3D, both of 15 sec and 25 sec are needed postfiltering 5 mm. And 8 times are proper for subset 8 iteration in Flash3D. OSEM2D needs post-filtering. And it is proper that subset 4, iteration 8 times for 15sec and subset 8, iteration 12 times for 25sec. The study regarding to injected doses for a patient and study time, combination of input parameter-15 sec/frame, LEHR collimator, analysing program-Flash3D, subset 8, iteration 8times and Gaussian post-filtering 5mm is the most appropriate. On the other hands, it was not appropriate to apply LEUHR collimator to 1-day subtraction method of Diamox study because of lower sensitivity. Conclusions: We could prove that there was also an advantage of short study time effectiveness in Dual camera same as Triple gamma camera and get great result of alternation from existing fan-beam collimator to parallel collimator. In addition, resolution and contrast of new method was better than FBP method. And it could improve sensitivity and accuracy of image because lesser subjectivity was input than Metz filter of FBP. We expect better image quality and shorter study time of Brain SPECT on Dual detector system.

  • PDF

Evaluation of Average CT to Reduce the Artifact in PET/CT (PET/CT 검사에서 호흡에 따른 인공산물을 줄이기 위한 Average CT의 유용성)

  • Kim, Jung-Sun;Nam, Ki-Pyo;Park, Seung-Yong;Ryu, Jae-Kwang;Cha, Min-Kyeong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.3-7
    • /
    • 2010
  • Purpose: The usefulness of Positron Emission Tomography (PET) images in diagnosis, staging, recurrent and treatment response evaluation has already been known. However, tumors which are small size, located in lower lobe of lung or upper lobe of liver are shown misalignment, distortion and different Standard Uptake Value (SUV) by respiration in PET images. Therefore, if radiotherapy based on normal respiration, it may cause low treatment response or more side effects because targets which had to treat, out of treat range or over dose to normal tissue. The purpose of this study is to evaluate attenuation-correction with Average CT (ACT) for more accuracy SUV measurement and minimize artifact by respiration. Materials and Methods: 13 patients, who had tumors which are around the diaphragm, underwent ACT scan after Helical CT (HCT) scan with PET/CT (Discovery DSTE 8; GE Healthcare). We quantified the differences between attenuation corrected image with HCT and attenuation corrected image with ACT in artifact size and maximum SUV ($SUV_{max}$). Artifacts were evaluated by measurement of the curved photogenic area in the lower thorax of the PET images for all patients. $SUV_{max}$ was measured separately at the primary tumors. Analysis program was Advantage Workstation v4.3 (GE Healthcare). Patients were injected with 7.4 MBq (0.2 $mC_i$) per kg of $^{18}F$-FDG and scanned 1 hour after injection. The PET acquisition was 3 minute per bed. Results: Significantly lower artifact were observed in PET/ACT images than in PET/HCT images (below-thoracic artifacts caused by under corrected $1.5{\pm}3.5$ cm vs. $13.4{\pm}4.2$ cm). Significantly higher $SUV_{max}$ were noted in PET/ACT images than in PET/HCT images in the primary tumor. Compared with PET/HCT images, $SUV_{max}$ in PET/ACT images were higher by $5.3{\pm}3.9%$ (mean value) tumor. The highest difference was observed in Lower lobe of lung (7.7 to 8.7; 13%). Conclusion: Due to its significantly reduced artifacts in lower thoracic, attenuation corrected image with ACT images provided more reliable $SUV_{max}$ and may be helpful in monitoring treatment response. Moreover, ACT can separate upper lobe of liver and lower lobe of lung, it may be helpful in interpretation. ACT will be clinically useful, considering increased dose caused by ACT scan and adapt.

  • PDF

Application of the Orally Inserted Guiding Device for the Improved Motion Artifacts of the Cervical Spine MRI (경추부 자기공명영상의 움직임 인공물 개선을 위한 구강내 삽입 유도 기구의 적용)

  • Lee, Jaeheun;Yu, Yunsik;Lee, Jaeseung;Im, Inchul
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.6
    • /
    • pp.317-323
    • /
    • 2014
  • This study aims to suggest and test methods using an orally inserted guiding device in order to improve a motion artifact by involuntary oral motor such as removing one's dentures and swallowing saliva clinically structured cervical spine scan and to make the optimal image by minimizing motion artifact. A cervical spine test was conducted with 30 patients who wore dentures among those who had a cervical spinal disease from January 1, 2014 through June 30, 2014. As for testing methods, after removing denture, T1-TSE-Sagittal, T2-TSE-Sagittal, T1-TSE-Axial and T2-TSE-Axial were obtained in a normal position and a supine position; the orally inserted guiding device was inserted in patients' mouth; and then T1-TSE-Axial and T2-TSE-Axial were retested. As a result, in SNR, T1-TSE-Axial before inserting an orally inserted guiding device was $22.33{\pm}8.59$; T1-TSE-Axial after inserting the orally inserted guiding device was $25.21{\pm}7.93$; T2-TSE-Axial before inserting the orally inserted guiding device was $14.49{\pm}5.74$; and T2-TSE-Axial after inserting the orally inserted guiding device was $16.61{\pm}6.72$. In CNR, T1-TSE-Axial was measured at $0.23{\pm}0.01$ while T2-TSE-Axial at $0.21{\pm}0.01$. As a result of the qualitative analysis, T1-TSE-Axial before inserting the orally inserted guiding device was $3.49{\pm}0.11$; T1-TSE-Axial after inserting the orally inserted guiding device was $3.95{\pm}0.14$; T2-TSE-Axial before inserting the orally inserted guiding device was $3.25{\pm}0.18$; and T2-TSE-Axial after inserting the orally inserted guiding device was $3.68{\pm}0.09$. As a result of using an orally inserted guiding device, the resolution and contrast of the images improved as the patients' involuntary artifact decreased because of removing dentures and swallowing saliva, and it was found that the interpretation of the images and identification of the diseases improved.

Development of Conformal Radiotherapy with Respiratory Gate Device (호흡주기에 따른 방사선입체조형치료법의 개발)

  • Chu Sung Sil;Cho Kwang Hwan;Lee Chang Geol;Suh Chang Ok
    • Radiation Oncology Journal
    • /
    • v.20 no.1
    • /
    • pp.41-52
    • /
    • 2002
  • Purpose : 3D conformal radiotherapy, the optimum dose delivered to the tumor and provided the risk of normal tissue unless marginal miss, was restricted by organ motion. For tumors in the thorax and abdomen, the planning target volume (PTV) is decided including the margin for movement of tumor volumes during treatment due to patients breathing. We designed the respiratory gating radiotherapy device (RGRD) for using during CT simulation, dose planning and beam delivery at identical breathing period conditions. Using RGRD, reducing the treatment margin for organ (thorax or abdomen) motion due to breathing and improve dose distribution for 3D conformal radiotherapy. Materials and Methods : The internal organ motion data for lung cancer patients were obtained by examining the diaphragm in the supine position to find the position dependency. We made a respiratory gating radiotherapy device (RGRD) that is composed of a strip band, drug sensor, micro switch, and a connected on-off switch in a LINAC control box. During same breathing period by RGRD, spiral CT scan, virtual simulation, and 3D dose planing for lung cancer patients were peformed, without an extended PTV margin for free breathing, and then the dose was delivered at the same positions. We calculated effective volumes and normal tissue complication probabilities (NTCP) using dose volume histograms for normal lung, and analyzed changes in doses associated with selected NTCP levels and tumor control probabilities (TCP) at these new dose levels. The effects of 3D conformal radiotherapy by RGRD were evaluated with DVH (Dose Volume Histogram), TCP, NTCP and dose statistics. Results : The average movement of a diaphragm was 1.5 cm in the supine position when patients breathed freely. Depending on the location of the tumor, the magnitude of the PTV margin needs to be extended from 1 cm to 3 cm, which can greatly increase normal tissue irradiation, and hence, results in increase of the normal tissue complications probabiliy. Simple and precise RGRD is very easy to setup on patients and is sensitive to length variation (+2 mm), it also delivers on-off information to patients and the LINAC machine. We evaluated the treatment plans of patients who had received conformal partial organ lung irradiation for the treatment of thorax malignancies. Using RGRD, the PTV margin by free breathing can be reduced about 2 cm for moving organs by breathing. TCP values are almost the same values $(4\~5\%\;increased)$ for lung cancer regardless of increasing the PTV margin to 2.0 cm but NTCP values are rapidly increased $(50\~70\%\;increased)$ for upon extending PTV margins by 2.0 cm. Conclusion : Internal organ motion due to breathing can be reduced effectively using our simple RGRD. This method can be used in clinical treatments to reduce organ motion induced margin, thereby reducing normal tissue irradiation. Using treatment planning software, the dose to normal tissues was analyzed by comparing dose statistics with and without RGRD. Potential benefits of radiotherapy derived from reduction or elimination of planning target volume (PTV) margins associated with patient breathing through the evaluation of the lung cancer patients treated with 3D conformal radiotherapy.

A study on evaluation of the image with washed-out artifact after applying scatter limitation correction algorithm in PET/CT exam (PET/CT 검사에서 냉소 인공물 발생 시 산란 제한 보정 알고리즘 적용에 따른 영상 평가)

  • Ko, Hyun-Soo;Ryu, Jae-kwang
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.1
    • /
    • pp.55-66
    • /
    • 2018
  • Purpose In PET/CT exam, washed-out artifact could occur due to severe motion of the patient and high specific activity, it results in lowering not only qualitative reading but also quantitative analysis. Scatter limitation correction by GE is an algorism to correct washed-out artifact and recover the images in PET scan. The purpose of this study is to measure the threshold of specific activity which can recovers to original uptake values on the image shown with washed-out artifact from phantom experiment and to compare the quantitative analysis of the clinical patient's data before and after correction. Materials and Methods PET and CT images were acquired in having no misalignment(D0) and in 1, 2, 3, 4 cm distance of misalignment(D1, D2, D3, D4) respectively, with 20 steps of each specific activity from 20 to 20,000 kBq/ml on $^{68}Ge$ cylinder phantom. Also, we measured the distance of misalignment of foley catheter line between CT and PET images, the specific activity which makes washed-out artifact, $SUV_{mean}$ of muscle in artifact slice and $SUV_{max}$ of lesion in artifact slice and $SUV_{max}$ of the other lesion out of artifact slice before and after correction respectively from 34 patients who underwent $^{18}F-FDG$ Fusion Whole Body PET/CT exam. SPSS 21 was used to analyze the difference in the SUV between before and after scatter limitation correction by paired t-test. Results In phantom experiment, $SUV_{mean}$ of $^{68}Ge$ cylinder decreased as specific activity of $^{18}F$ increased. $SUV_{mean}$ more and more decreased as the distance of misalignment between CT and PET more increased. On the other hand, the effect of correction increased as the distance more increased. From phantom experiments, there was no washed-out artifact below 50 kBq/ml and $SUV_{mean}$ was same from origin. On D0 and D1, $SUV_{mean}$ recovered to origin(0.95) below 120 kBq/ml when applying scatter limitation correction. On D2 and D3, $SUV_{mean}$ recovered to origin below 100 kBq/ml. On D4, $SUV_{mean}$ recovered to origin below 80 kBq/ml. From 34 clinical patient's data, the average distance of misalignment was 2.02 cm and the average specific activity which makes washed-out artifact was 490.15 kBq/ml. The average $SUV_{mean}$ of muscles and the average $SUV_{max}$ of lesions in artifact slice before and after the correction show a significant difference according to a paired t-test respectively(t=-13.805, p=0.000)(t=-2.851, p=0.012), but the average $SUV_{max}$ of lesions out of artifact slice show a no significant difference (t=-1.173, p=0.250). Conclusion Scatter limitation correction algorism by GE PET/CT scanner helps to correct washed-out artifact from motion of a patient or high specific activity and to recover the PET images. When we read the image occurred with washed-out artifact by measuring the distance of misalignment between CT and PET image, specific activity after applying scatter limitation algorism, we can analyze the images more accurately without repeating scan.

Reproducibiity of setup error for prostate cancer by ultrasound image-guided radiation therapy (전립선암에 대한 초음파 영상유도 방사선치료의 Setup 오차 분석을 통한 재현성 평가)

  • Park, Sung Yong;Lim, Seung Kyu;Si, Myoung Geun;Lee, Ji Hae;Kim, Jong Yeol;Cho, Eun Joo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.2
    • /
    • pp.75-81
    • /
    • 2017
  • Purpose: To evaluate the reproducibility of image-guided radiotherapy using ultrasonography which is non-invasive, without radiation exposure for prostate cancer patients. Materials and Methods: We analyzed the setup variation of 1,105 images for 26 prostate cancer patients and the mean, standard deviation and 3D-error in AP, RL and SI directions. Setup variations were classified 0-1 mm, 1-3 mm, 3-5 mm, 5 mm and more. Results: The mean and standard deviation of setup variation in AP, RL and SI directions was $1.87{\pm}1.36mm$, $1.73{\pm}1.22mm$ and $2.01{\pm}1.40mm$. The 3D-error in AP, RL and SI directions was $3.63{\pm}1.63mm$. The frequency of setup variation in AP direction was 29 % in the range from 0 mm to 1 mm, 50.2 % in the range from 1 mm to 3 mm, 19.6 % in the range from 3 mm to 5 mm and 1.3 % in the range of 5 mm or more. In RL direction, the frequency was 31.3 % in the range from 0 mm to 1 mm, 52.5 % in the range from 1 mm to 3 mm, 15.8 % in the range from 3 mm to 5 mm and 0.5 % in the range of 5 mm or more. SI direction, the frequency of errors in the range from 0 mm to 1 mm was 26.3 %, 50.2 % in the range from 1 mm to 3 mm, 22.4 % in the range from 3 mm to 5 mm, and 1.1 % in the range of 5 mm or more. Conclusion: The setup error was highest in the SI direction of $2.01{\pm}1.40mm$. The frequency in each direction was the highest in more than 50 % in the range from 1 mm to 3 mm. $Clarity^{TM}$ Auto scan is possible to monitoring the motion of the prostate during the treatment and to repositioning the patient. In conclusion real-time image-guided radiotherapy using ultrasonography will be increase the reproducibility of radiation therapy.

  • PDF

Effects of Head Posture on Resting EMG Activity of Craniocervical Muscles and on Occlusal Contacts (두부자세에 따른 두경부 근활성 및 교합접촉양태의 변화)

  • Chang-Kweon Song;Kyung-Soo Han;Chan Chung
    • Journal of Oral Medicine and Pain
    • /
    • v.21 no.1
    • /
    • pp.89-101
    • /
    • 1996
  • This study was performed to investigate influence of the changes of head posture on resting electromyographic (EMG) activity in anterior temporalis, masseter, sternocleidomastoid muscle and trapezius, and on status of occlusal contacts. For this study twenty-nine patients with temporomandibular disorders(TMD) and thirty dental students without any masticatory symptoms were selected as patients group and control group, respectively. EMG activity($\mu$V) at rest was observed in four kind of head postures such as natural or normal head posture(NHP), forward head posture(FHP), upward head posture(UHP), downward head posture(DHP), and in NHP and FHP, EMG activity with flat occlusal splint was also checked. BioEMG$^\textregistered$(Bioelectromyograph, Bioresearch Inc., USA) was used to record EMG activity in the above four muscles with eight locations on both sides. The author used T-Scan$^\textregistered$(Tekscan Co., USA) system to investigate the changes of oclusal contats on clenching in the four head postures about number, force, time(duration) and total left-right statistis(TLR, occlusal stability crossing left-right dental arch on clenching). For taking in upward or downward head posture, head was inclined $10^{\circ}$ upward or downward and CROM$^\textregistered$ (cervical-range-of motion, Performance attainment Inc., USA) was used to maintain same posture during the procedure. The results obtained were as follows : 1. For resting EMG activity, anterior temporalis did not show any difference by change of head posture, but masseter and sternocleidomastoid muscle showed higher value of EMG activity in FHP and UHP, and trapezius showed higher value of EMG activity in FHP and DHP. 2. EMG activity of trapezius was higher than that of any other muscles in NHP, FHP, and DHP, but in UHP, the activity was the lowest reversely. 3. Patients group showed higher EMG activity than control group did in all the muscles in NHP. And significant difference between the two groups were also observed in anterior temporalis in FHP, in sternocleidomastoid muscle in UHP, and in sterno-cleidomastoid muscle and trapezius in DHP with higher activity in patients group. 4. There was no change of EMG activity in NHp with splint, but EMG activity in anterior temporalis and masseter was decreased in FHP with splint. 5. In general, status of occlusal contacts was not changed with head posture in all subjects, and difference between patients group and control group was only noted for number and force of tooth contact in UHP and DHP with more value in control group. 6. Correlationship between EMG activity and number ad force of tooth contacts was shown negatively with regard to masseter in NHP, and trapezius in UHP and DHP.

  • PDF

Functional Significance of Angiographic Collaterals in Patients with Totally Occluded Right Coronary Artery: Intracoronary Thallium-201 Scintigraphy (우측 관상동맥 폐쇄 환자에서 관상동맥내 Thallium-201 주사를 이용한 측부 혈행의 의의)

  • Lee, Do-Yun;Lee, Jong-Doo;Cho, Seung-Yun;Shim, Won-Heum;Ha, Jong-Won;Kim, Han-Soo;Kwon, Hyuk-Moon;Jang, Yang-Soo;Chung, Nam-Sik;Kim, Sung-Soon;Park, Chang-Yun;Kim, Young-Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.27 no.2
    • /
    • pp.210-217
    • /
    • 1993
  • To compare the myocardial viability in patients suffering from total occlusion of the right coronry artery (RCA) with the angiographic collaterals, intracoronary injection of Thallium-201 (T1-201) was done to 14 coronary artery disease (CAD) patients (pts) with total occlusion of RCA and into four normal subjects for control. All 14 CAD pts had Grade 2 or 3 collateral circulations. There were 14 male and 4 females, and their ages ranged from 31 to 70 years. In nine pts, T1-201 was injected into left main coronary artery (LCA) ($300{\sim}350{\mu}Ci$) to evaluate the myocardial viability of RCA territory through collateral circulations. The remaining five pts received T1-201 into RCA ($200{\sim}250{\mu}Ci$) because two had intraarterial bridging collaterals and three had previous successful PTCA. Planar & SPECT myocardial perfusion images were obtained 30 minutes, and four to five hours after T1-201 injection. Intravenous T1-201 reinjection (six pts) or $^{99m}Tc-MIBI$ (two pts) were also performed in eight CAD pts. Intracoronary myocardial perfusion images were compared with intravenous T1-201 (IV T1-201) images, ECG, and ventriculography. Intracoronary T1-201 images proved to be superior to that of IV T1-201 due to better myocardial to background uptake ratio and more effective in the detection of viable tissue. We also found that perfusion defects were smaller on intracoronary T1-201 images than those on the IV T1-201. All of the 14 CAD pts had either mostly viable myocardium (seven pts) or large area of T1-201 perfusion (seven pts) in RCA territory, however ventriculographic wall motion and ECG did not correlate well with intracoronary myocardial perfusion images. In conclusion, total RCA occlusion patients with well developed collateral circulation had large area of viable myocardial in the corresponding territory.

  • PDF

A Study of the Chewing Patterns in Patients with Temporomandibular Disorders by Electrognathography (Electrognathography를 이용한 측두하악장애환자의 저작양태에 관한 연구)

  • Moon-Gyu Kim;Kyung-Soo Han
    • Journal of Oral Medicine and Pain
    • /
    • v.20 no.2
    • /
    • pp.291-306
    • /
    • 1995
  • Mandibular movement is composed of border movement and functional movement. Border movement such as maximal mouth opening, hinge opening ad lateral eccentric movement has good reproducibility, but functional movement such as chewing, swallowing and speech has also reproducibility. Especially for chewing movement, individual reproducibility has been confirmed by many studies. Study of chewing pattern is still in controversy. In new approach for raising the diagnostic value, numeric parameters and morphologic characteristics could be used for evaluation of chewing pattern. This study was performed to investigate the differences between chewing pattern in controls and in patients with temporomandibular disorders. Sixty-three patients with temporomandibular disorders participated in this study, and they were divided into unilaterally affected subjects or bilaterally affected subjects. Then unilaterally affected subjects were classified into closed lock group, disk displacement with reduction group, and degenerative joint disease group. For recording of chewing pattern, subjects were asked to chew one piece of presoftened chewing gum on both sides, and the chewing movement was recorded with the Electrognatho- Graphy(Bio-Research Associates Inc., U.S.A.). Tooth contact pattern for occlusal stability (Total left-right statistics )was also recorded with T-Scan(Tekscan Co., U.S.A.). The dta related to chewing pattern and total left-right statistics were statistically analyzed by SAS/stat program. The obtained results were as follows : 1. In patient group, mean value of A-P distance and the ratio of A-P distance to vertical distance were larger than control group, but the value of lateral distance in affected side and the closing velocity in unaffected side were smaller than that of control group, respectively. 2. In case of unilateral affected patients, chewing pattern of other side had tendency to restricted movement and slow velocity in closed lock group or degenerative joint disease group than control group or disk displacement with reduction group. 3. In bilateral degenerative joint disease patients, contralateral side had tendency to large range of motion and slow chewing velocity than preferred chewing side. 4. The patients with restricted mouth opening below than 35mm had higher value of total left-right statistics than patient group mouth opening above 35mm. Also closed lock group had higher total left-right statistics than disk displacement with reduction group, degenerative joint disease group and control group. 5. There was some difference in morphologic characteristics of chewing pattern between in control group and in affected side of unilateral patient group, but no difference between control group and unaffected side of unilateral patient group. 6. There were positive correlations between vertical distance and A-P distance, between vertical distance and chewing velocity, between A-P distance and chewing velocity, and between opening velocity and closing velocity in unilateral affected patients.

  • PDF