• Title/Summary/Keyword: Scan method

Search Result 1,540, Processing Time 0.027 seconds

Evaluation of Cerebral Aneurysm with High Resolution MR Angiography using Slice Interpolation Technique: Correlation wity Digital Subtraction Angiography(DSA) and MR Angiography(MRA) (Slice Interpolation기법의 고해상도 자기공명혈관조영술을 이용한 뇌동맥류의 진단 : 디지탈 감산 혈관조영술과 자기공명 혈관조영술의 비교)

  • ;;;Daisy Chien;Gerhard Laub
    • Investigative Magnetic Resonance Imaging
    • /
    • v.1 no.1
    • /
    • pp.94-102
    • /
    • 1997
  • Purpose: There have been some efforts to diagnose intracranial aneurysm through a non-invasive method using MRA, although the process may be difficult when the lesion is less than 3mm. The present study prospectively compares the results of high resolution, fast speed slice interpolation MRA and DSA thereby examing the potentiality of primary non-invasive screening test. Materials and Methods: A total of 26 cerebral aneurysm lesions from 14 patients with subarachnoid hemorrhage from ruptured aneurysm (RA) and 5 patients with unruptured aneurysm(UA). In all subjects, MRA was taken to confirm the vessel of origin, definition of aneurysm neck and the relationship of the aneurysm to nearby small vessels, and the results were compared with the results of DSA. The images were obtained with 1.5T superconductive machine (Vision, Siemens, Erlangen, Germany) on 4 slabs of MRA using slice interpolation. The settings include TR/TE/FA=30/6.4/25, matrix $160{\times}512$, FOV $150{\times}200$, 7minutes 42 seconds of scan time, effective thickness of 0.7 mm and an entire thickness of 102. 2mm. The images included structures from foramen magnum to A3 portion of anterior cerebral artery. MIP was used for the image analysis, and multiplanar reconstruction (MPR) technique was used in cases of intracranial aneurysm. Results: A total of 26 intracranial aneurysm lesions from 19 patients with 2 patients having 3 lesion, 3 patients having 2 lesions and the rest of 14 patients having 1 lesion each were examined. Among those, 14 were RA and 12 were UA. Eight lesions were less than 2mm in size, 9 lesions were 3-5mm, 7 were 6-9mm and 2 were larger than IOmm. On initial exams, 25 out of 26 aneurysm lesions were detected in either MRA or DSA showing 96% sensitivity. Specificity cannot be estimated since there was no true negative of false positive findings. When MRA and MPR were used concurrently for the confirmation of size and shape, the results were equivalent to those of DSA, while in the confirmation of aneurysm neck and parent vessels, the concurrent use of MRA and MPR was far superior to the sole use of either MRA or DSA. Conclusion: High resolution MRA using slice interpolation technique showed equal results as those of DSA for the detection of intracranial aneurysm, and may be used as a primary non-invasive screening test in the future.

  • PDF

Prevalence of Intimal Defect in the Patients urith Surgically Treated Acute Type A Intramural Hematoma of the Aorta (외과적으로 치료한 급성 A형 대동맥벽내 혈종 환자에서 대동맥 내막 결손의 존재 빈도)

  • Park, Kay-Hyun
    • Journal of Chest Surgery
    • /
    • v.40 no.11
    • /
    • pp.733-744
    • /
    • 2007
  • Background: There is a controversy regarding the pathogenesis and management principle of an acute intramural hematoma (IMH) of the aorta, Recent studies have reported intimal defects in many patients diagnosed with IMH, and suggested that intimal defects play important roles in the pathogenesis, progression of the pathology, and prognosis. Material and Method: This study reviewed the preoperative and postoperative computed tomography (CT) scan images of 36 patients who underwent surgical treatment for Stanford type A acute IMH of the aorta. The surgical findings were also reviewed retrospectively from the medical records. Result: In 15 patients (41.7%), the findings suggestive of the intimal defects were found in the preoperative CT. During the operation, 20 patients (72.2%) were found to have small intimal defects in the ascending aorta or the arch, of which 13 patients (50.5%) did not have the CT findings suggestive of intimal defects. In 17 patients, the intimal defects were located in the aortic arch or distal ascending aorta, where a gross examination would have been impossible without total circulatory arrest. In all patients, the intimal defects identified were included in the resected aortic segment, or locally closed. Follow-up CT at 4 months or longer after surgery showed that the IMH in the descending aorta had disappeared or was markedly improved. Conclusion: Most patients undergoing surgical treatment for acute type A IMH had intimal defects. This suggests that a large proportion of IMH might have a similar pathogenic mechanism as classic dissection. Consequently, it is believed that those two entities of acute aortic syndrome should be treat-ed using the same principles.

Feasibility Study of Isodose Structure Based Field-in-Field Technique for Total Body Irradiation (전신조사방사선치료 시 Isodose Structure를 이용한 Field-in-Field Technique의 유용성 평가)

  • Lee, Yoon Hee;Ban, Tae Joon;Lee, Woo Seok;Kang, Tae Young;Back, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.1
    • /
    • pp.15-24
    • /
    • 2013
  • Purpose: In Asan Medical Center, Two parallel opposite beams are employed for total body irradiation. Patients are required to be in supine position where two arms are attached to mid axillary line. Normally, physical compensators are required to compensate the large dose difference for different parts of body due to the different thicknesses compared to the umbilicus separation. There was the maximum dose difference up to 30% in lung and chest wall compared to the prescription dose. In order to resolve the dose discrepancy occurring on different body regions, the feasibility of using Fieid-in-Field Technique is investigated in this study. Materials and Methods: CT scan was performed to The RANDO Phantom with fabricated two arms and sent to Eclipse treatment planning system (version 10.0, Varian, USA). Conventional plan with physical lead compensator and new plan using Field-in-Field Technique were established on TPS. AAA (Anisotropic Analytical Algorithm) dose calculation algorithm was employed for two parallel opposite beams attenuation. Results: The dose difference between two methods was compared with the prescription dose. The dose distribution of chest and anterior chest wall uncovered by patient arms was 114~124% for physical lead compensator while Field-in-Field Technique gave 106~107% of the dose distribution. In-vivo dosimetry result using TLD showed that the dose distribution to the same region was 110~117% for conventional physical compensator and 104~107% for Field-in-Field Technique. Conclusion: In this study, the feasibility of using FIF technique has been investigated with fabricated arms attached Rando phantom. The dose difference was up to 17% due to the attached arms. It is shown that the dose homogeneity is within ${\pm}10%$ with the CT based 3-dimensional 4 step FIF technique. The in-vivo dosimetry result using TLD was showed that 95~107% dose distribution compared to prescription dose. It is considered that CT based 3-dimensional Field-in-Field Technique for the total body irradiation gives much homogeneous dose distribution for different body parts than the conventional physical compensator method and might be useful to evaluate the dose on each part of patient body.

  • PDF

Analysis of Exploratory Thoracotomy in Non-Small Cell Lung Cancer (원발성 폐암에서의 시험적 개흉술의 분석)

  • 허재학;성숙환;김영태
    • Journal of Chest Surgery
    • /
    • v.32 no.6
    • /
    • pp.536-542
    • /
    • 1999
  • Background: The purpose of this study is to improve the quality of the diagnostic procedures in the preoperative evaluation so as to reduce the unnecessary thoracotomy and to ensure resectability in non-small cell lung cancer. Material and Method: Of 616 patients who underwent thoracotomy for primary lung cancer from January 1990 to December 1996, 59 patients(9.6%) turned out to have inoperable lesions after the thoracotomy. We reprospectively reviewed the bronchoscopic findings, methods of tissue diagnosis, CT scans, pulmonary function test and lung perfusion scan, reasons for nonresectability, and adjuvant therapy, and then followed up on the survival rate after exploratory thoracotomy. Result: The cell types were squamous cell carcinoma in 38, adenocarcinoma in 15, large cell carcinoma in 3 and others in 3. Primary loci were RUL in 20, RML in 6, RLL in 8, LUL in 13, LLL in 4 and others in 8. The reasons for non-resectability were various; direct tumor invaison to mediastinal structures(n=41), seeding on pleural cavity(n=8), poor pulmonary function(n=2), invasions to extranodal mediastinal lymph node(n=2), technical non- resectability due to extensive chest wall invasion (n=3), small cell carcinoma (n=1), malignant lymphoma(n=1), and multiple rib metastases(n=1). In the follow-up of 58 patients, 1-year survival rate was 55.2% and 2-year survival rate was 17.2% and the mean survival time was 14 months. When compared according to cell types or postoperative adjuvant therapeutic modalities, no significant difference in the survival rates were found. The squamous cell carcinoma was frequently accompanied by local extension to contiguous structures and was the main cause of non-resectability. In adenocarcinoma, pleural seeding with malignant effusion was frequently encountered, and was the major reason for non-resectability. Conclusion: These data revealed that if appropriate preoperative diagnostic tools had been available, many unnecessary thoracotomies could have been avoided. Both the use of thoracoscopy in selected cases of adenocarcinoma and the more aggressive surgical approach to the locally advanced tumor could reduce the incidence of unnecessary thoracotomies for non-small cell lung cancers.

  • PDF

Developmental Genetic Analysis of Avian Primordial Germ Cells and the Application to Poultry Biotechnology

  • Kagami, H.
    • Korean Journal of Poultry Science
    • /
    • v.28 no.2
    • /
    • pp.135-142
    • /
    • 2001
  • A novel sterategy has been established to determine the origin of the Primordial Germ Cells (PGCs) in avian embryos directly and the developmental fate of the PGCs for the application to Poultry biotechnology. Cells were removed from 1) the centre of area pellucida, 2) the outer of area pellucida and 3) the area opaca of the stage X blastoderm (Eyal-Giladi & Kochav, 1976). When the cells were removed from the centre of area pellucida, the mean number of circulating PGCs in blood was significantly decreased in the embryo at stage 15 (Hamburger & Hamilton, 1951) as compared to intact embryos. When the cells were replenished with donor cells, no reduction in the PGCs number was observed. The removal of cells at the outer of area pellucida or at the area opaca had no effect on the number of PGCs. In case, another set of the manipulated embryos were cultured ex vivo to the hatching and reared to the sexual maturity, the absence of germ cells and degeneration of seminiferous tubules was observed in resulting chickens derived from the blastoderm in which the cells were removed from the centre of the area pellucida. It was concluded that the avian Primordial Germ cells are originated at the center of area pellucida. Developmental ability of the cells to differentiate into somatic cells and germ cells in chimeras were analyzed. Somatic chimerism was detected as black feather attributed from donor cells. Molecular identification by use of female - specific DNA was performed. It was confirmed that the donor cells could be differentiated into chimeric body and erythrocytes. Donor cells retained the ability to differentiate into germline in chimeric gonads. More than 70% of the generated chimeras transmitted donor derived gametes to their offspring indicating that the cells at the center of area pellucida had the high ability to differentiate into germ cells. A molecular technique to identify germline chimerism has been developed by use of gene scan analysis. Strain specific DNA fragments were amplified by the method. It would be greatly contributed for the detection of germline chimerism. Mixed- sex chimeras which contained both male and female cells were produced to investigate the developmental fate of male and female cells in ovary and testes. The sex combinations of donor and recipient of the resulting chimeras were following 4 pairs; (1) chimeras (ZZ/ZZ) produced by a male donor (ZZ) and a male recipient (ZZ), (2) chimeras (ZW/ZW) produced by a female donor (ZW) and a female recipient (ZW), (3) chimeras (ZZ/ZW) Produce by a male donor (ZZ) and a female recipient (ZW), (4) chimeras (ZW/ZZ) produced by a female donor (ZW) and a male recipient (ZZ). It was found that genetically male avian germ cells could differentiate into functional ova and that genetically female germ cells can differentiate into functional spermatozoa in the gonad of the mixed- sex chimeras. An ability for introduction of exogenous DNA into the PGCs from stage X blastoderms were analyzed. Two reporter genes, SV-$\beta$gal and RSV-GFP, were introduced into the PGCs. Expression of bacterial/gal was improved by complexing DNA with liposome detectedcc in 75% of embryos at 3 days embryos. At the embryos incubated for 1 day, expression of the GFP was observed all the embryos. At day 3 of incubation, GFP was detected in about 70% of the manipulated embryos. In case of GFP, expression of the transgene was detected in 30 %e of the manipulated embryos. These results suggested that the cells is one of the most promising vectors for transgenesis. The established strategy should be very powerfull for application to poultry biotechnology.

  • PDF

Locates the Sunken Ship 'Dmitri Donskoi' using Marine Geophysical Survey Techniques in Deep Water (지구물리 탐사기법을 이용한 심해 Dmitri Donskoi호 확인)

  • Yoo, Hai-Soo;Kim, Su-Jeong;Park, Dong-Won
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.104-117
    • /
    • 2004
  • Dmitri Donskoi, which went down during the Russo-Japanese War occurred 100 years ago, was found by using geophysical exploration techniques at the 400 m water depth of submarine valley off Jeodong of Ulleung Island. In the submarine area with the rugged seabed topography and volcanic seamounts, in particular, the reliable seabed images were acquired by using the mid-to-shallow Multibeam exploration technique The strength of corrosion (causticity) of the sunken Donskoi, measured by the electrochemical method, decreased to 2/5 compared with the original strength.

  • PDF

Urinary Tract Infection and Vesicoureteral Reflux in Children (소아에서의 요로감염과 방광요관역류에 관한 고찰)

  • Lim Hyun-Suk;Park Chang-Ro;Ko Cheol-Woo;Koo Ja-Hoon
    • Childhood Kidney Diseases
    • /
    • v.1 no.1
    • /
    • pp.46-52
    • /
    • 1997
  • Urinary tract infection (UTI) in children has been known to be a cause of renal damage, leading to scar formation, hypertension and renal failure. And vesico-ureteral reflex (VUR), frequently accompanying UTI in young children, has been incriminated as the main factor causing scar formation. This retrospective study has been undertaken to see the relationship among UTI, VUR and renal scar formation. Study population consisted of 291 children (boy 134, girl 42) with UTI, who have been admitted to the Pediatric Department of Kyungpook University Hospital during 6 1/2 year period from January 1990 to June 1996. VUR was diagnosed by VCUG and renal scar by ultrasonogram, DMSA scan (or DMSA SPECT) and IVP. The following result were obtained. Sexual difference showed male predominance (male to female, 134:42) below 1 year of age, and female predominance (male to female, 11:35) over 5 years of age were rioted. VUR has been found in 64 children (22%) and the degree of reflux, classfied by the method proposed by 'International Reflux Study in Children', were as follows ; Grade I : 4.0%, Grade II : 3.0%, Grade III : 2.7%, Grade IV : 5.8% and Grade V : 6.2%. There was no sexual difference E.coli was the most predominant infecting agent occurring in 167 children (57%), and end-stage renal failure was diagnosed at the time of first admission in 5 children with Grade V VUR. Renal scar has been noted in 49 out of 582 kidneys (8.4%), and the incidence of scar foramation according to the degree of VUR were as follow ; Grade 0 (No reflux) : 1.2%, Grade I : 6.7%, Grade II 27.3%, Grade III 29.4%, Grade IV : 57.1%, and Grade V : 100%. In summary, present study shows that renal scar formation in UTI has close correlation with the severity of VUR occurring more frequently in severe reflux, so that early diagnosis and proper treatment of UTI and VUR is of paramount importance in preventing renal damage in children with UTI.

  • PDF

Quantitative Comparisons in $^{18}F$-FDG PET Images: PET/MR VS PET/CT ($^{18}F$-FDG PET 영상의 정량적 비교: PET/MR VS PET/CT)

  • Lee, Moo Seok;Im, Young Hyun;Kim, Jae Hwan;Choe, Gyu O
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.68-80
    • /
    • 2012
  • Purpose : More recently, combined PET/MR scanners have been developed in which the MR data can be used for both anatometabolic image formation and attenuation correction of the PET data. For quantitative PET information, correction of tissue photon attenuation is mandatory. The attenuation map is obtained from the CT scan in the PET/CT. In the case of PET/MR, the attenuation map can be calculated from the MR image. The purpose of this study was to assess the quantitative differences between MR-based and CT-based attenuation corrected PET images. Materials and Methods : Using the uniform cylinder phantom of distilled water which has 199.8 MBq of $^{18}F$-FDG put into the phantom, we studied the effect of MR-based and CT-based attenuation corrected PET images, of the PET-CT using time of flight (TOF) and non-TOF iterative reconstruction. The images were acquired from 60 minutes at 15-minute intervals. Region of interests were drawn over 70% from the center of the image, and the Scanners' analysis software tools calculated both maximum and mean SUV. These data were analyzed by one way-anova test and Bland-Altman analysis. MR images are segmented into three classes(not including bone), and each class is assigned to each region based on the expected average attenuation of each region. For clinical diagnostic purpose, PET/MR and PET/CT images were acquired in 23 patients (Ingenuity TF PET/MR, Gemini TF64). PET/CT scans were performed approximately 33.8 minutes after the beginnig of the PET/MR scans. Region of interests were drawn over 9 regions of interest(lung, liver, spleen, bone), and the Scanners' analysis software tools calculated both maximum and mean SUV. The SUVs from 9 regions of interest in MR-based PET images and in CT-based PET images were compared. These data were analyzed by paired t test and Bland-Altman analysis. Results : In phantom study, MR-based attenuation corrected PET images generally showed slightly lower -0.36~-0.15 SUVs than CT-based attenuation corrected PET images (p<0.05). In clinical study, MR-based attenuation corrected PET images generally showed slightly lower SUVs than CT-based attenuation corrected PET images (excepting left middle lung and transverse Lumbar) (p<0.05). And percent differences were -8.01.79% lower for the PET/MR images than for the PET/CT images. (excepting lung) Based on the Bland-Altman method, the agreement between the two methods was considered good. Conclusion : PET/MR confirms generally lower SUVs than PET/CT. But, there were no difference in the clinical interpretations made by the quantitative comparisons with both type of attenuation map.

  • PDF

The Understanding and Application of Noise Reduction Software in Static Images (정적 영상에서 Noise Reduction Software의 이해와 적용)

  • Lee, Hyung-Jin;Song, Ho-Jun;Seung, Jong-Min;Choi, Jin-Wook;Kim, Jin-Eui;Kim, Hyun-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.54-60
    • /
    • 2010
  • Purpose: Nuclear medicine manufacturers provide various softwares which shorten imaging time using their own image processing techniques such as UlatraSPECT, ASTONISH, Flash3D, Evolution, and nSPEED. Seoul National University Hospital has introduced softwares from Siemens and Philips, but it was still hard to understand algorithm difference between those two softwares. Thus, the purpose of this study was to figure out the difference of two softwares in planar images and research the possibility of application to images produced with high energy isotopes. Materials and Methods: First, a phantom study was performed to understand the difference of softwares in static studies. Various amounts of count were acquired and the images were analyzed quantitatively after application of PIXON, Siemens and ASTONISH, Philips, respectively. Then, we applied them to some applicable static studies and searched for merits and demerits. And also, they have been applied to images produced with high energy isotopes. Finally, A blind test was conducted by nuclear medicine doctors except phantom images. Results: There was nearly no difference between pre and post processing image with PIXON for FWHM test using capillary source whereas ASTONISH was improved. But, both of standard deviation(SD) and variance were decreased for PIXON while ASTONISH was highly increased. And in background variability comparison test using IEC phantom, PIXON has been decreased over all while ASTONISH has shown to be somewhat increased. Contrast ratio in each spheres has also been increased for both methods. For image scale, window width has been increased for 4~5 times after processing with PIXON while ASTONISH showed nearly no difference. After phantom test analysis, ASTONISH seemed to be applicable for some studies which needs quantitative analysis or high contrast, and PIXON seemed to be applicable for insufficient counts studies or long time studies. Conclusion: Quantitative values used for usual analysis were generally improved after application of the two softwares, however it seems that it's hard to maintain the consistency for all of nuclear medicine studies because result images can not be the same due to the difference of algorithm characteristic rather than the difference of gamma cameras. And also, it's hard to expect high image quality with the time shortening method such as whole body scan. But it will be possible to apply to static studies considering the algorithm characteristic or we can expect a change of image quality through application to high energy isotope images.

  • PDF

Video-Assisted Thoracic Surgery Lobectomy for Non-Small Cell Lung Cancer: Experience of 133 Cases (폐암에서의 흉강경 폐엽절제술 치험 133예)

  • Kim, Hyeong-Ryul;Cho, Jeong-Su;Jang, Hee-Jin;Lee, Sang-Cheol;Choi, Eun-Suk;Jheon, Sang-Hoon;Sung, Soak-Whan
    • Journal of Chest Surgery
    • /
    • v.42 no.5
    • /
    • pp.615-623
    • /
    • 2009
  • Background: We evaluated the feasibility and the efficacy of Video-Assisted Thoracic Surgery (VATS) lobectomy for treating patients with non-small cell lung cancer (NSCLC) and we compared the outcomes of VATS lobectomy with those of open lobectomy. Material and Method: From 2003 to March 2008, 133 NSCLC patients underwent VATS lobectomy. The patients were selected on the basis of having clinical stage I disease on the chest CT and PET scan. The outcomes of 202 patients who underwent open lobectomy (OL group) for clinical stage I NSCLC were evaluated to compare their results with those of the patients who underwent VATS lobectomy (the VL group). Result: The number of females and the number of patients with adenocarcinoma and stage IA disease were greater in VL group (p<0.05). There was no operative mortality or major complications in the VL group. Conversion to thoracotomy was needed in 8 cases (6%), which was mostly due to bleeding. The chest tube indwelling time and the length of the postoperative hospital stay were significantly shorter in the VL group (p<0.001). The number of dissected lymph nodes and the size of tumor were significantly smaller in the VL group (p<0.001). For the pathologic stage I patients, there was no significant difference in the three-year survival rates between the two groups (p=0.15). Conclusion: VATS lobectomy is a safe procedure with low operative mortality and morbidity. VATS lobectomy is feasible for early stage NSCLC and it provides outcomes that are comparable to those for open lobectomy. Further long-term data are needed.