• Title/Summary/Keyword: Scan Model

Search Result 472, Processing Time 0.023 seconds

A Study on Optimized Mapping Environment for Real-time Spatial Mapping of HoloLens

  • Hwang, Leehwan;Lee, Jaehyun;Hafeez, Jahanzeb;Kang, Jinwook;Lee, Seunghyun;Kwon, Soonchul
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.9 no.3
    • /
    • pp.1-8
    • /
    • 2017
  • Recently, the development of the head mounted display (HMD) device has attracted a great deal of attention to the actual contents. Especially, Augmented Reality (AR), which is a mixture of actual information and virtual world information, is focused on. AR HMD is able to interact by arranging virtual objects in real space through spatial recognition using depth camera. In order to naturally mix virtual space with real space, it is necessary to develop a technology for realizing spatial mapping information with high accuracy. The purpose of this paper is to evaluate the optimal configuration of augmented reality application program by realizing accurate spatial mapping information when mapping a real space and an object placement environment using HoloLens. To do this, we changed the spatial mapping information in real space to three levels, which are the number of meshes used in cubic meters to scan step by step. After that, it was compared with the 3D model obtained by changing the actual space and mesh number. Experimental result shows that the higher the number of meshes used in cubic meters, the higher the accuracy between real space and spatial mapping. This paper is expected to be applied to augmented reality application programs that require scanning of highly mapped spatial mapping information.

Edge-Adaptive Color Interpolation for CCD Image Sensor

  • Heo, Bong-Su;Hong, Hun-Seop;Gang, Mun-Gi
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.39 no.1
    • /
    • pp.1-8
    • /
    • 2002
  • The color interpolation scheme can play an important role in overcoming the physical limitation of the CCD image sensor and in increasing the resolution of color signals, while most conventional approaches result in blurred edges and false color artifacts. In this paper, we have proposed an improved edge-adaptive color interpolation scheme for a progressive scan CCD image sensor with RGB color filter array The edge indicator function proposed utilizes not only the within-channel correlation but also the cross-channel correlation, and reflects the edge characteristics of an image adaptively. The color components unavailable for at each channel are interpolated along the edge direction, not across the edges, so that aliasing artifacts are supressed. Furthermore, we eliminated false color artifacts resulting from the color image formation model in the edge-adaptive color interpolation scheme by adopting the switching algorithm based on the color edge detection. Simulation results of the proposed algorithm indicate that the improved edge-adaptive color interpolation scheme produces quantitatively better and visually more pleasing results than conventional approaches.

Comparison of prosthetic models produced by traditional and additive manufacturing methods

  • Park, Jin-Young;Kim, Hae-Young;Kim, Ji-Hwan;Kim, Jae-Hong;Kim, Woong-Chul
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.4
    • /
    • pp.294-302
    • /
    • 2015
  • PURPOSE. The purpose of this study was to verify the clinical-feasibility of additive manufacturing by comparing the accuracy of four different manufacturing methods for metal coping: the conventional lost wax technique (CLWT); subtractive methods with wax blank milling (WBM); and two additive methods, multi jet modeling (MJM), and micro-stereolithography (Micro-SLA). MATERIALS AND METHODS. Thirty study models were created using an acrylic model with the maxillary upper right canine, first premolar, and first molar teeth. Based on the scan files from a non-contact blue light scanner (Identica; Medit Co. Ltd., Seoul, Korea), thirty cores were produced using the WBM, MJM, and Micro-SLA methods, respectively, and another thirty frameworks were produced using the CLWT method. To measure the marginal and internal gap, the silicone replica method was adopted, and the silicone images obtained were evaluated using a digital microscope (KH-7700; Hirox, Tokyo, Japan) at 140X magnification. Analyses were performed using two-way analysis of variance (ANOVA) and Tukey post hoc test (${\alpha}=.05$). RESULTS. The mean marginal gaps and internal gaps showed significant differences according to tooth type (P<.001 and P<.001, respectively) and manufacturing method (P<.037 and P<.001, respectively). Micro-SLA did not show any significant difference from CLWT regarding mean marginal gap compared to the WBM and MJM methods. CONCLUSION. The mean values of gaps resulting from the four different manufacturing methods were within a clinically allowable range, and, thus, the clinical use of additive manufacturing methods is acceptable as an alternative to the traditional lost wax-technique and subtractive manufacturing.

Accuracy of provisional crowns made using stereolithography apparatus and subtractive technique

  • Kang, Seen-Young;Park, Jung-Hyun;Kim, Ji-Hwan;Kim, Woong-Chul
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.5
    • /
    • pp.354-360
    • /
    • 2018
  • PURPOSE. To compare and analyze trueness and precision of provisional crowns made using stereolithography apparatus and subtractive technology. MATERIALS AND METHODS. Digital impressions were made using a master model and an intraoral scanner and the crowns were designed with CAD software; in total, 22 crowns were produced. After superimposing CAD design data and scan data using a 3D program, quantitative and qualitative data were obtained for analysis of trueness and precision. Statistical analysis was performed using normality test combined with Levene test for equal variance analysis and independent sample t-test. Type 1 error was set at 0.05. RESULTS. Trueness for the outer and inner surfaces of the SLA crown (SLAC) were $49.6{\pm}9.3{\mu}m$ and $22.5{\pm}5.1{\mu}m$, respectively, and those of the subtractive crown (SUBC) were $31.8{\pm}7.5{\mu}m$ and $14.6{\pm}1.2{\mu}m$, respectively. Precision values for the outer and inner surfaces of the SLAC were $18.7{\pm}6.2{\mu}m$ and $26.9{\pm}8.5{\mu}m$, and those of the SUBC were $25.4{\pm}3.1{\mu}m$ and $13.8{\pm}0.6{\mu}m$, respectively. Trueness values for the outer and inner surfaces of the SLAC and SUBC showed statistically significant differences (P<.001). Precision for the inner surface showed significance (P<.03), whereas that for the outer surface showed no significance (P<.58). CONCLUSION. The study demonstrates that provisional crowns produced by subtractive technology are superior to crowns fabricated by stereolithography in terms of accuracy.

Development of a Representative Model for Different Body Shapes of 18-24 Aged Women - An Application of a 3D Morphing Technique - (3차원 모핑기법에 의한 18-24세 여성의 체형별 대표 형상 도출을 위한 연구)

  • Shin, Ju-Young;Choi, Young-Lim;Nam, Yun-Ja
    • Fashion & Textile Research Journal
    • /
    • v.13 no.4
    • /
    • pp.590-599
    • /
    • 2011
  • The purpose of this study is to classify body types into different groups based on 3D scanned data, and identify the representative body shapes that most frequently appear in the groups. A high frequency range was defined based on body measurement data, and representative shapes were identified based on body scan data of women aged 18-24. The major findings of this study are as follows. First, the three typical types of height, bust and drop mixes among Korean women aged 18-24 are as follows:) 155-88-N,) 160-82-A, and 165-85-A. Regarding the body type, the A and N types frequently appeared, while the H type was rare. Second, among the subjects of the high-frequency groups, upright bodies were selected as sample models and were used for morphing. An adjustment was made to the morphing results to reflect the body characteristics of the sample models evenly. Third, to verify the morphing results, the body sizes of the sample models and the created models were compared. The result showed that, the sizes were close to the average size of the sample models. Fourth, to verify whether the morphing processes adequately reflected the features of the body shapes, cross-section models of key body parts were made and the degree of representativeness was determined.

Development of Program for Designing Barrel Cam of Machine Making Paper Cups (종이컵 성형기용 배럴 캠 설계 프로그램 개발)

  • Kim, Wook-Hyeon;Park, Tae-Won
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.4
    • /
    • pp.433-438
    • /
    • 2011
  • A machine that makes paper cups has many parts, including a barrel cam, an index, and a turret. When the barrel cam, which is the main operating part of the machine, rotates, it pushes the roller fixed on the index, and paper cups are formed as the turret connected to the index rotates. Therefore, the performance of the machine is affected by the barrel cam. In this study, the program for designing barrel cam, which creates the profile of the cam is developed using MATLAB. This profile is used to develop a 3D CAD model by using a 3D CAD program. Dynamic models containing the barrel cam are created on the basis of the profile and 3D laser scan of the barrel cam. Further, the rotation angle of the index in the machine is measured using a high-speed camera. The rotation angles of the dynamics models are compared to verify the effectiveness of the program.

Customized Cranioplasty Implants Using Three-Dimensional Printers and Polymethyl-Methacrylate Casting

  • Kim, Bum-Joon;Hong, Ki-Sun;Park, Kyung-Jae;Park, Dong-Hyuk;Chung, Yong-Gu;Kang, Shin-Hyuk
    • Journal of Korean Neurosurgical Society
    • /
    • v.52 no.6
    • /
    • pp.541-546
    • /
    • 2012
  • Objective : The prefabrication of customized cranioplastic implants has been introduced to overcome the difficulties of intra-operative implant molding. The authors present a new technique, which consists of the prefabrication of implant molds using three-dimensional (3D) printers and polymethyl-methacrylate (PMMA) casting. Methods : A total of 16 patients with large skull defects (>100 $cm^2$) underwent cranioplasty between November 2009 and April 2011. For unilateral cranial defects, 3D images of the skull were obtained from preoperative axial 1-mm spiral computed tomography (CT) scans. The image of the implant was generated by a digital subtraction mirror-imaging process using the normal side of the cranium as a model. For bilateral cranial defects, precraniectomy routine spiral CT scan data were merged with postcraniectomy 3D CT images following a smoothing process. Prefabrication of the mold was performed by the 3D printer. Intraoperatively, the PMMA implant was created with the prefabricated mold, and fit into the cranial defect. Results : The median operation time was $184.36{\pm}26.07$ minutes. Postoperative CT scans showed excellent restoration of the symmetrical contours and curvature of the cranium in all cases. The median follow-up period was 23 months (range, 14-28 months). Postoperative infection was developed in one case (6.2%) who had an open wound defect previously. Conclusion : Customized cranioplasty PMMA implants using 3D printer may be a useful technique for the reconstruction of various cranial defects.

Assessment of Factors Associated with the Safety Depth of GV15 Yamen -Factors Associated with the Safety Depth of GV15-

  • Park, Soo-Jung;Jin, Ming;Joo, Jong-Cheon;Kwon, Young-Mi
    • Journal of Pharmacopuncture
    • /
    • v.17 no.1
    • /
    • pp.70-73
    • /
    • 2014
  • Objectives: Yamen is the fifteenth acupoint of the Governor Vessel Meridian (GV15). It is anatomically close to the medulla oblongata, so finding the safety depth of the acupoint is very important. However, few studies on the safety depth of GV15 have been done. Methods: This study tried to measure the safety depth of GV15 by using magnetic resonance imaging (MRI) scans and to analyze the factors affecting the safety depth through multiple regression analyses. This study was carried out for patients who had a brain MRI scan while visiting Jeonju Wonkwang Hospital, Korea. The shortest distance between the glabella and the occipital protuberance (DGO), the horizontal distance between the glabella and the back of the head (DGB) and the dangerous depth (DD) were measured from the sagittal views of the MRI images. The DD is the horizontal distance from the skin's surface at GV15 to the spinal dura mater. Results: The model suggested that the safety depth (SD) was significantly associated with gender (${\beta}$ = 0.474, P < 0.0001), DGO (${\beta}$ = 0.272, P = 0.027), and BMI (${\beta}$ = 0.249, P = 0.005) and the combination of three variables can explain the SD, with $R^2$ = 0.571 (Table 3). A longer SD was associated with males and with greater BMI and DGO. Conclusion: This study suggests that gender, BMI and DGO may be important factors when the SD of GV15 is considered clinically through a multiple regression analysis of GV15.

A Study of the Thematically Integrated Information Literacy Curriculum for Strengthening its Relationship with Curricula (교과 연계성 강화를 위한 학습주제 중심의 통합 정보활용교육과정에 관한 연구)

  • Song, Gi-Ho;Kim, Tae-Soo
    • Journal of the Korean Society for information Management
    • /
    • v.25 no.3
    • /
    • pp.41-64
    • /
    • 2008
  • This study sought to develop an integrated information literacy curriculum that would have a strong relationship with curricula through the standard themes abstracted from theme network structures, scan and cluster analyses of the information literacy curricula. In addition, this study also attempted to develop a teaching-learning model for the developed integrated information literacy curriculum. This study utilized the themes of information literacy instruction that have interdisciplinary characteristics as analysis criteria in analyzing the commonality of information literacy instruction and the subject curricula. The following characteristics were found from the analyzing the areas of commonality. Foremost, the first themes(the fields of basic learning skills and nature) which belongs to the fields of information society, library, information technology, collaborative skills were found to have many relationships with the subject curricula. Next, the second themes(the field of information problem solving capabilities) which is the core field of information literacy instruction showed a weak relationship with the subject curricula.

A Study on Changes in Biomechanical Characteristics of the Foot with Respect to Wedge-type Insole Thickness (키높이 인솔두께에 따른 족부의 생체역학적 특성변화에 대한 연구)

  • Park, T.H.;Jung, T.G.;Han, D.W.;Lee, Sung-Jae
    • Journal of Biomedical Engineering Research
    • /
    • v.34 no.2
    • /
    • pp.80-90
    • /
    • 2013
  • Recently, functional insoles of wedge-type it is for the young to raise their height inserted between insole and heel cause foot pain and disease. Additionally, these have a problem with stability and excessively load-bearing during gait like high-heel shoes. In this study, we compared the changes in biomechanical characteristics of foot with different insole thickness then we will utilize for the development of the insole with the purpose of relieving the pain and disease. Subjects(male, n = 6) measured COP(center of pressure) and PCP(peak contact pressure) on the treadmill(140cm/s) using F-scan system and different insole thickness(0~50 mm) between sole and plantar surface during gait. Also, we computed changes of stresses at the foot using finite element model with various insole thickness during toe-off phase. COP moved anterior and medial direction and, PCP was increased at medial forefoot surface, $1^{st}$ and $2^{nd}$ metatarsophalangeal, ($9%{\uparrow}$) with thicker insoles and it was show sensitive increment as the insole thickness was increased from 40 mm to 50 mm. Change of the stress at the soft-tissue of plantar surface, $1^{st}$ metatarsal head represents rapid growth($36%{\uparrow}$). Also, lateral moments were increased over the 100% near the $1^{st}$ metatarsal as the insole thickness was increased from 0 mm to 30 mm. And it is show sensitive increment as the insole thickness changed 10 mm to 20 mm. As a result, it was expected that use of excessively thick insoles might cause unwanted foot pain at the forefoot region. Therefore, insole thickness under 30 mm was selected.