• Title/Summary/Keyword: Scan Design

Search Result 508, Processing Time 0.029 seconds

Development of the Side Scan Sonar Using the Multi-beam Sensors : Sensor Design (멀티빔 센서를 이용한 사이드 스캔 소나 개발 : 센서 설계)

  • Chang, Yu-Shin;Keh, Joong-Eup;Jo, Heung-Gi;Lee, Man-Hyung
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.54 no.10
    • /
    • pp.581-586
    • /
    • 2005
  • The multi-beam side scan sonar system uses the towfish installed sonars, it is an equipment that search images of the bottom surface of the sea in real time. It is a typical equipment that is related to a sea investigation such as a geological survey, seabed communication cable and power line cable placing repair investigation, fish breeding ground investigation, sea purification, relic and mineral investigation, and mine and submarine search. Recently, it is used to sea purification and geological survey that require information of the correct surface of the seabed. Therefore, this research develops multi-beam sensors for a side scan sonar that supply various information with the fast scan speed and correct high resolution that is not a simple underwater investigation equipment.

New Scan Design for Delay Fault Testing of Sequential Circuits (순차 회로의 지연 고장 검출을 위한 새로운 스캔 설계)

  • 허경회;강용석;강성호
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.9
    • /
    • pp.1161-1166
    • /
    • 1999
  • Delay testing has become highlighted in the field of digital circuits as the speed and the density of the circuits improve greatly. However, delay faults in sequential circuits cannot be detected easily due to the existence of state registers. To overcome this difficulty a new scan filp-flop is devised which can be used for both stuck-at testing and delay testing. In addition, the new scan flip-flop can be applied to both the existing functional justification method and the newly-developed reverse functional justification method which uses scan flip-flops as storing the second test patterns rather than the first test patterns. Experimental results on ISCAS 89 benchmark circuits show that the number of testable paths can be increased by about 10% on the average.

  • PDF

HARDWARE DESIGN OF A SCAN CONVERTER USING SPLINE INTERPOLATION (스플라인 보간법을 적용한 스캔 변환기의 하드웨어 구현)

  • 권영민;이범근;정연모
    • Proceedings of the IEEK Conference
    • /
    • 2000.11b
    • /
    • pp.71-74
    • /
    • 2000
  • The purpose of format conversion is to convert a wide range of personal computer video formats into a target format. Circuits for the conversion have been developed by means of interpolation techniques, such as zero-order interpolation, bilinear interpolation, and bisigmoidal interpolation. This paper proposes a scan converter using cubic splines. The converter was modeled in VHDL on Max+PlusII and implemented with an FPGA chip. The circuit gives much better conversion performance than a scan converter with zero-order or linear interpolation.

  • PDF

Development of Optimimized State Assignment Technique for Partial Scan Designs (부분 스캔을 고려한 최적화된 상태 할당 기술 개발)

  • 조상욱;양세양;박성주
    • Proceedings of the IEEK Conference
    • /
    • 1999.11a
    • /
    • pp.392-395
    • /
    • 1999
  • The state assignment for a finite state machine greatly affects the delay, area, and testabilities of the sequential circuits. In order to minimize the dependencies among state variables, therefore possibly to reduce the length and number of feedback cycles, a new state assignment technique based on m-block partition is introduced in this paper. After the completion of state assignment and logic synthesis, partial scan design is performed to choose minimal number of scan flip-flops. Experiment shows drastic improvement in testabilities while preserving low area and delay overhead.

  • PDF

Submarine Terrain Exploration for the Coast Using Side Scan Sonar (측면주사음탐기를 이용한 연안지역 해저지형탐사)

  • 이종출;문두열;김대현;서동주
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2004.11a
    • /
    • pp.539-544
    • /
    • 2004
  • In this study, locational information data acquisited by using the side scan sonar which is more precise than traditional submarine terrain' survey equipment. And the result of exploration through the object area(the East sea), accurate submarine terrain could be deciphered by sounded image. Also, in the future, side scan sonar's application will be maximized for the submarine terrain's sediment investigation to design or construction of ocean facilities.

  • PDF

DESIGN OF A SCAN CONVERTER SUING SPLINE INTERPOLATION (스플라인 보간법을 이용한 스캔 변환기 설계)

  • 이범근
    • Proceedings of the Korea Society for Simulation Conference
    • /
    • 2000.04a
    • /
    • pp.91-95
    • /
    • 2000
  • The purpose of format conversion is to convert a wide range of personal computer video formats to a target format. Circuits for the conversion has been developed by means of interpolation techniques, such as zero-order interpolation, bilinear interpolation, and bisigmoidal interpolation. This paper proposes a scan converter using cubic splines. The converter was modeled in VHDL on Max+Plus II and implemented with an FPGA cpip. The circuit gives much better conversion performance than a scan converter with zero-order or linear interpolation.

  • PDF

A Study on Use of Anthropometric Data and 3D Body Scan Data at Apparel Industry

  • Chun, Jongsuk
    • The International Journal of Costume Culture
    • /
    • v.6 no.1
    • /
    • pp.19-29
    • /
    • 2003
  • The 3D measurement data expected be useful to give appropriate garment fit and development of MTM(Made-to-Measure) CAD software. The researcher surveyed the need and use of national anthropometric data of the apparel industry. 17 Korean apparel manufacturers participated in the study. The need of anthropometric data at 5 different apparel business sectors was measured: men's suit, women's dress, casual-wear, underwear, and active sportswear. The result of the survey shows that height and bust, waist, hip circumferences are needed by all of the business sectors. The body measurements at the scye and upper arm area were need most by the men's suit manufacturers. The women's foundation garment manufacturers were well prepared for the use of the 3D body scan data and they expected the potential benefits of 3D body scan data would be great. The researcher also conducted a case study and found a pro and con of the using 3D body scan data for apparel product developing process. In the current stage of technical advance, a reasonable method was required to get nude like scan data for the women's foundation garment manufacturer. The researcher concluded that the apparel designer could use the 3D scan data for developing tremendous style garment design and pattern making.

  • PDF

A Design of New Real Time Monitoring Embedded Controller using Boundary Scan Architecture (경계 주사 구조를 이용한 새로운 실시간 모니터링 실장 제어기 설계)

  • 박세현
    • Journal of Korea Multimedia Society
    • /
    • v.4 no.6
    • /
    • pp.570-578
    • /
    • 2001
  • Boundary scan architecture test methodology was introduced to facilitate the testing of complex printed circuit board. The boundary scan architecture has a tremendous potential for real time monitoring of the operational status of a system without interference of normal system operation. In this paper, a new type of embedded controller for real time monitoring of the operational status of a system is proposed and designed by using boundary scan architecture. The proposed real time monitoring embedded controller consists of test access port controller and an embedded controller proposed real time monitoring embedded controller using boundary scan architecture can save the hard-wire resource and can easily interface with boundary scan architecture chip. Experimental results show that the real time monitoring using proposed embedded controller is more effective then the real time monitoring using host computer.

  • PDF

The Verification of Accuracy of 3D Body Scan Data - Focused on the Cyberware WB4 Whole Body Scanner - (3차원 인체 스캔 데이터의 정확도 검증에 관한 연구 - Cyberware의 WB4 스캐너를 중심으로 -)

  • Park, Sun-Mi;Nam, Yun-Ja
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.14 no.1
    • /
    • pp.81-96
    • /
    • 2012
  • The purpose of this study is to provide fundamental information for standardization of 3D body measurement. This research analyzes errors occurring in the process of extracting body size from 3D body scan data. First, as a result of analyzing basic state of the 3D body scanner's calibration, the point number of each section was almost the same, while the right and left as well as the front and back coordinates of the center of gravity are not, showing unstable data. Nevertheless, the latter does not influence on the size of cylinder such as width and circumference. Next, we analyzed point coordinates variations of scan data on a mannequin nude by life casting. The result was great deflection in case of complicated or horizontal sections including the reference point beyond proper distance from centers of four cameras. In case of the mannequin's size, accuracy proves comparatively high in that measurement errors in height, width, depth, and length dimension occurred all within allowable errors, only except chest depth, while there were a lot of measurement errors in a circumference dimension. Secondly, analysis of accuracy of automatic extraction identification program algorithm presented that a semi-automatic measurement program is better than an automatic measurement program. While both of them ate very acute in parts related to crotch, they are not in armpit related parts. Therefore, in extracting of human body size from 3D scan data, what really matters seems to parts related to armpits.

  • PDF

CAD/CAM fabricated complete denture using 3D face scan: A case report (3D face scan을 이용한 CAD/CAM 제작 의치 증례)

  • Eom, Dae-Young;Leesungbok, Richard;Lee, Suk-Won;Park, Su-Jung;Ahn, Su-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.4
    • /
    • pp.436-443
    • /
    • 2017
  • In the past, computer-aided design / computer-aided manufacturing (CAD/CAM) technology was the closed system that users had to use the components of only one manufacturer. At present, it has changed to the open system with the flexibility to select and use the components of various manufacturers' components according to their needs. Despite the development of dental materials and prostheses manufacturing methods, denture manufacturing has followed conventional manufacturing methods for nearly 100 years. However, studies on CAD/CAM fabricated denture have been recently carried out to overcome the disadvantages of conventional denture manufacturing. Some commercialized products using milling or 3D printing have already been applied clinically. This case report confirms the possibility of CAD/CAM dentures using 3D face scan and compared them to conventionally fabricated dentures.