• Title/Summary/Keyword: Scale efficiency

Search Result 3,043, Processing Time 0.031 seconds

A Design of High Pressure Sub-scale Combustor and the Assessment of Combustion Efficiency (고압 축소형 연소기의 설계 및 연소효율 평가)

  • Lee, Kwang-Jin;Kim, Hong-Jip;Ryu, Chul-Sung;Han, Yeoung-Min;Choi, Hwan-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.169-174
    • /
    • 2006
  • This paper is related to a design of high pressure sub-scale combustor with regenerative reeling. As a previous step for the evaluation of thermal heat flux, a similar combustor with cooling water was manufactured. Design conditions with high combustion efficiency and cooling performance were verified through the hot firing tests of the water-cooled high pressure combustor. Finally the regeneratively cooled high pressure combustor has been designed based on these data. After manufacturing it, its practical utility will be tested and verified through hot firing tests.

  • PDF

Analysis of Operating Characteristics of Large-scale Solar Thermal System Using Two Types of Collectors (두 종류 태양열 집열기를 이용하는 대규모 태양열 시스템의 동작특성 분석)

  • Lee, Dong-Won;Heo, Jae-Heok;Kim, Min-Hwi
    • Journal of the Korean Solar Energy Society
    • /
    • v.37 no.2
    • /
    • pp.67-75
    • /
    • 2017
  • We have investigated the operating characteristics of $1,600m^2$ large-scale solar thermal system installed in an eco-friendly energy town in Chungbuk Innovation City. The operation criteria of the collecting pump and storage pump were different from the existing standard, and it was confirmed that each pump works well according to the changed criteria. Based on the data of the representative day, the daily collecting heat (efficiency) and the production (storing) heat (efficiency) were estimated. It was confirmed that the daily collecting heat (efficiency) of the flat plate type was higher than that of the evacuated tube type, but the useful heat production was more in evacuated tube type collector.

A Study on a Small-scale Wastewater Treatment System Using MBR and IPNR (MBR과 IPNR을 이용한 소규모 하수처리 시스템에 관한 연구)

  • Kim, Young-Hee;Jo, Eun-Young;Yeo, In-Seol;Park, Seung-Min;Park, Chan-Gyu
    • The KSFM Journal of Fluid Machinery
    • /
    • v.18 no.2
    • /
    • pp.37-42
    • /
    • 2015
  • In the purpose of this study, we investigate the characteristics of the pilot-scale wastewater treatment system applied to BAF, MBR and IPNR as examining the removal efficiency of organic pollutants and operating factors in small decentralized wastewater treatment systems, and operating factors. For long-term operation period of more than nine months, pilot-scale plant operating results appeared very stable. This results were the removal efficiency of BOD was 80.3% above and removal efficiency of COD with an average of about 91.0%, satisfied the final effluent water quality standards. TN in the final effluents was the average concentration of 7.9 mg/L, was satisfactory water quality standards 10 mg/L of TN.

Analysis of Detention Efficiency according to Location and Scale of Regional Detention Facilities (유역분담저류지의 위치 및 규모에 따른 저류효과 분석)

  • Kim, Ji-Tae;Jin, Kyeong-Hyeok;Kim, Soo-Jun;Kim, Young-Bok
    • 한국방재학회:학술대회논문집
    • /
    • 2007.02a
    • /
    • pp.579-582
    • /
    • 2007
  • In this paper, the inundation simulations were carried out by using GIS tools for the analysis of detention efficiency based on the results of runoff analysis according to location and scale of regional detention facilities. The inundation maps could be drawn by the inundation simulations, and the locations and magnitude of inundation areas could be estimated through the inundation maps. The inundation simulations with GIS tools are approved to be the one of the useful method in designing optimized location and scale of regional detention facilities.

  • PDF

A module of Semitransparent Dye-sensitized Solar Cell (반투명 염료감응 태양전지 모듈 연구)

  • Kang, Man Gu
    • Journal of Integrative Natural Science
    • /
    • v.2 no.4
    • /
    • pp.237-242
    • /
    • 2009
  • As semitransparent dye-sensitized solar cells (DSSCs) have advanced to large-scale applications from lab-level research, the large-scale performance has attracted much attention. Modules of DSSCs have been investigated to optimize the efficiency as a $TiO_2$ systhesis temperature and a surface treatment of $TiCl_4$ aqueous solution. Essentially, these semitransparent modules have an extended structure with lab-scale works with the exception of the dimensions and methods for the series connection. The $5cm{\times}6.5cm$ modules have shown an efficiency of about 6% without a scattering layer. While the fill factors of modules depend on the width of each $TiO_2$ unit cell, they are much less dependent on the lengths of the unit cells.

  • PDF

Analysis of the Building Energy Efficiency Rating Certified for Public Office Buildings (공공기관 업무용 건물의 건축물에너지효율등급 인증 현황 분석)

  • Lee, Han-Sol;Kim, Seo-Hun;Kim, Jonghun;Kim, Jun-Tae;Jang, Cheol-Yong
    • KIEAE Journal
    • /
    • v.15 no.5
    • /
    • pp.75-82
    • /
    • 2015
  • Purpose: The first grade of Korea's Building Energy Efficiency Rating System(BEERS) is required for new government office buildings as a mandatory measure to reduce greenhouse gas emission. However, there is no specific criteria about performance that which level should apply to energy-saving design element for obtaining Building Energy Efficiency Rating 1st grade. Therefore, Certification status should be analyzed firstly, about the office building which is certificated. Certification analysis for office buildings acquired certification therefore should be done first. Method: In this study, Certification status(Office buildings acquired Building Energy Efficiency Rating Certification)was analyzed by classified year, region, specific scale etc. And we analyzed statistically by eliciting an average value of each element influencing to the amount of energy. Result: Energy demands were gradually decreased due to revision of thermal insulation standards for enhanced u-value. Energy consumptions were different from the kind of equipment and yearly trends applied depending on the size of the building. Total primary energy consumptions were influenced by heat source types and the primary energy scale factors.

Development of Optimal Septic Tank in the Countries of Water Shortages (물 부족국가에서 활용가능한 정화조의 최적모형 개발)

  • Lim, Bong-Su;Jing, Hai-Long
    • Journal of Korean Society on Water Environment
    • /
    • v.31 no.4
    • /
    • pp.418-427
    • /
    • 2015
  • This study was carried out to evaluate the performance of a lab-scale novel septic tank system for improving the conventional septic tank in the developing countries of water shortages. The lab-scale novel septic tank system consists of sepetic tank, aeration tank with HBC-ring, and sand filter. Optimum HRT was reguired about 1.5days to get a total COD removal efficiency of 90%, COD, BOD and SS removal efficiency was about 70%, 60%, and 85% in sepetic tank only. The structure of sepetic tank with two stages results in the high removal efficiency of organic matter. When sepetic tank, aeration tank, and sand filter were more than HRT 1.5days, 18hrs, and 12hrs, respectively, final effluent was less than 20 mg/L of BOD, 14 mg/L of SS, so that there is a high potential of its use for reusing water in flush toilet. There is no significant effect of HRT change on nutrient removal. Total nitrogen removal efficiency was about 40%, final effluent was 30~40 mg/L of TN, total phosphorus removal efficiency was about 11~25%, final effluent was 9~12 mg/L of TP. Because there is very small amounts of organic nitrogen and phosphorus in effluent, it was possible to reuse water for agricultural use.

Impact of energy efficiency improvement on greenhouse gas in off-season tomato farming: Evidence from Punjab, Pakistan

  • Ali, Qamar;Khan, Muhammad T.I.;Khan, Muhammad N.I.
    • Advances in Energy Research
    • /
    • v.5 no.3
    • /
    • pp.207-217
    • /
    • 2017
  • Energy consumption in agriculture is responsible for greenhouse gas emission but it can be reduced after efficient utilization of energy inputs. Therefore, the present study aims for the estimation of energy efficiency and extent of greenhouse gas reduction after benchmarking of inefficient farms in off-season tomato in Punjab province of Pakistan. Primary data were collected from 70 farmers with simple random sampling. By using data envelopment analysis, the average value of technical, pure technical and scale efficiency was 0.80, 0.92 and 0.87, respectively while increasing, constant and decreasing return to scale was observed in 33, 26 and 11 farmers, respectively. Total input energy was reduced by $12,688.91MJ\;ha^{-1}$ (13.89%) if inefficient farms used the energy inputs according to recommendations or benchmarking. A major portion of energy saving comes from fertilizers (68.79%) followed by diesel (15.70%), chemicals (5.91%), machinery (4.37%) and water (4.00%). Total greenhouse gases reduction was $499.17kg\;CO_2\;eq.ha^{-1}$ (14.57%) as a result of improvement in energy efficiency or benchmarking of inefficient farms. Agricultural extension staff should visit the vegetable farms on regular basis and give necessary information about efficient utilization of energy inputs. The government should create awareness about the optimum use of input through seminars and pamphlets.

Analysis on Factors of Management Efficiency for Bean Farm Households (콩 재배농가의 경영효율성에 영향을 주는 원인분석)

  • Kim, Mi-Ok;Lee, Sang-Lae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.2
    • /
    • pp.265-271
    • /
    • 2016
  • DEA is a typical method that allows measurements and evaluations of the efficiency. This study examined the management efficiency of bean farm households to suggest factors that influence the management efficiency. The results showed that a larger cultivation area has more positive effects on the scale efficiency of beans farm households. When summing up farmer's family labor, lease fee, hired labor cost, which are strongly related to the workforce, it reached up to 54.6%. This means that they all occupy more than half of the production cost and they show an increasing trend. Moreover, although the hired labor rate is higher, it has more positive influences on the gross efficiency, technical efficiency and scale efficiency. In addition, the results showed that environmentally-friendly agriculture decreases the efficiency.

A Study on the Efficiency Analysis of IT Service Companies Using Meta Frontier and the Determinants of Efficiency Using Tobit Model (Meta Frontier를 이용한 국내 IT서비스기업의 효율성 분석 및 Tobit 모형을 이용한 효율성 결정요인 분석에 대한 연구)

  • Shin, Minsoo;Park, Jiyong
    • Journal of Information Technology Services
    • /
    • v.16 no.4
    • /
    • pp.15-31
    • /
    • 2017
  • This study analyzes 45 Korea IT service companies from 2012 to 2016 using DEA analysis. Large enterprises, medium enterprises and small and medium enterprises (SMEs). CCR model and BCC model were used for efficiency analysis. Among the various analytical objects, the decision objects which yield the maximum output with minimum input are compared with other analysis objects. The relative inefficiency was measured through this, and Technical Efficiency (TE), Pure Technology Efficiency (PTE), Scale Efficiency (SE), scale profit, reference frequency were analyzed. Also, we analyzed the Technology Gap Ratio (TGR), which is the distance between production function and Meta-Frontier for each firm, using Meta-Frontier analysis. Finally, the Tobit model is used to analyze the sources of efficiency and inefficiency. The inputs are assets, capital, and employees, and the output factor is sales. The analysis shows that large firms are achieving technological achievements more efficiently than small and medium enterprises. As a result, medium-sized enterprises and SMEs can improve efficiency overall through efficient operation of workforce and appropriate combination of inputs such as assets and capital. Also, as a result of the influence factor analysis, it was found that the ratio of the managed asset ratio and the management cost ratio were significant factors influencing the efficiency of the IT service companies. This study suggests the efficiency analysis using DEA for many Korea IT service companies. Inefficient parts of each company are classified according to size and technology. Also, we identify the most efficient companies and analyze the causes of those companies whose profits are lower than their size.