• Title/Summary/Keyword: Scale Bar

Search Result 301, Processing Time 0.031 seconds

Capability Analysis of Sensory Quality of Jajang Sauce

  • Imm, Bue-Young;Lee, Ji-Hye;Yeo, Ik-Hyun
    • Food Science and Biotechnology
    • /
    • v.18 no.3
    • /
    • pp.745-748
    • /
    • 2009
  • Sensory quality variations of jajang sauce were monitored by the $\bar{X}-chart$ and capability analysis based on specifications of each sensory attributes. For sensory quality control (QC) of the sauce which has a strong sweetness and sourness, the ratio of sourness/sweetness was examined as a necessary QC factor to maintain the balance of sweetness and sourness. For the sensory QC factors, all the sensory data were divided into individual sensory score of reference which was a pack of sauce manufactured a week ago. The ratio form of sensory data was useful for decreasing individual variations and for increasing normality of data measured by category scale. The overall proportion of out-spec products under normal manufacturing conditions was obtained by capability analysis of sensory data with normal distribution. Out-spec samples were monitored by the $\bar{X}-chart$ of each sensory attributes.

A Study on the Bond Strength of Wall-Slab Joint of Steel Plate-Concrete Structures (SC구조의 벽-바닥 접합부의 정착강도에 관한 연구)

  • Choi, Kyong-Min;Kim, Ki-Sung;Kim, Byoung-Kook;Kim, Won-Ki;Choi, Oan-Chul
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.321-324
    • /
    • 2006
  • An experimental study on the bond strength of wall-slab joint in SC(steel plate-concrete) structure was performed. Six-full scale specimens were tested. Specimens were constructed with key variables, such as, development length, location of the bar and quantity of the shear bar. The experimental results, show that as the development length and quantity of the shear bar increase, the bond strength increases. As the bars is located on the inside the stud bolt, the bond performance was highly increased compared to the bars located out of plane of the stud bolts.

  • PDF

On dark matter haloes of barred disc galaxies

  • Sodi, Bernardo Cervantes;Li, Cheng;Park, Changbom;Wang, Lixin;Lin, Ye
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.39 no.2
    • /
    • pp.56.2-56.2
    • /
    • 2014
  • We present an extensive study of the environment of galaxies with bars in the low-redshift Uni-verse, using a volume-limited sample of over 30,000 galaxies drawn from the Sloan Digital Sky Survey, with visually-determined morphological classifications and bar identifications. We use four different statistics to quantify the environment of our galaxies: the projected two-point cross-correlation function with respect to a spectroscopic sample of reference galaxies, the background-subtracted number count of galaxies in a deep photometric sample in the vicinity of our galaxies, the overdensity of the local environment estimated at ~3 Mpc scale from the three-dimensional reconstruction of the cosmic density field of the local Universe, and the membership of our galaxies in the SDSS galaxy groups to segregate central to satellite systems. We find a weak, but significant trend for early-type galaxies with a bar to be more strongly clustered on scales from a few 100 kpc to 1 Mpc, when compared to early-type galaxies without a bar. For late-type galaxies, we find less neighbours within ~50 kpc around the barred late-types when compared to the unbarred late-types. For late-type galaxies we also detect a decrease of the bar fraction for dark matter dominated systems, and finally we find no obvious correlation between the overdensity and the fraction of barred galaxies in our sample.

  • PDF

Design and Fabrication of Thrust Chamber for Injector verification of 7 tonf-class Thrust Chamber (7톤급 연소기용 분사기 검증을 위한 연소기 설계 및 제작)

  • Kim, Jong-Gyu;Ahn, Kyu-Bok;Choi, Hwan-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2012.05a
    • /
    • pp.457-460
    • /
    • 2012
  • Design and fabrication of a sub-scale thrust chamber for verification of 7 tonf-class thrust chamber injectors were described in this paper. The 7 tonf-class thrust chamber consists of mixing head with 90 coaxial swirl injectors and regeneratively combustion chamber cooled by kerosene. The coaxial swirl injectors with different pressure drop and recess number were designed for 7 tonf full-scale thrust chamber. By applying the designed injectors to the sub-scale thrust chamber before applying them to the full-scale thrust chamber, the injector performance and functioning were verified. The sub-scale thrust chamber consists of 19 injectors, has chamber pressure of 70 bar, total propellant mass flow rate of 4.3 kg/s, mixture ratio(O/F) of 2.45.

  • PDF

Application of Headed Bars with Small Head in Exterior Beam-Column Joints Subjected to Reversed Cyclic Loads (반복하중을 받는 외부 보-기둥 접합부에서 작은 헤드를 사용한 Headed Bar적용)

  • Ha, Sang-Su;Choi, Dong-Uk;Lee, Chang-Ho
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.4
    • /
    • pp.411-420
    • /
    • 2007
  • The applicability of headed bars in exterior beam-column joints under reversed cyclic loading was investigated. A total of ten pullout tests were first performed to examine pullout behavior of headed bars subjected to monotonic and cyclic loading with test variables such as connection type between head and bar stem (weld or no weld), loading methods (monotonic or cyclic loading), and head shape (small or large circular head and square head). Two full-scale beam-column joint tests were then performed to compare the structural behavior of exterior beam-column joints constructed using two different reinforcement details: i.e. $90^{\circ}$ standard hooks and headed bars. Both joints were designed following the recommendations of ACI-ASCE Committee 352 for Type 2 performance: i.e. the connection is required to dissipate energy through reversals of deformation into inelastic range. The pullout test results revealed that welded head to the stem did not necessarily result in increased pullout strength when compared to non-welded head. Relatively large circular head resulted in higher peak load than smaller circular and square head. Both beam-column joints with conventional $90^{\circ}$ hooks and headed bars behaved similarly in terms of crack development, hysteresis curves, and peak strengths. The joint using the headed bars showed better overall structural performance in terms of ductility, deformation capacity, and energy dissipation. These experimental results demonstrate that the headed bars using relatively small head can be properly designed far use in external beam-column joint.

Flexural behaviour of reinforced low-strength concrete beams strengthened with CFRP plates

  • Boukhezar, Mohcene;Samai, Mohamed Laid;Mesbah, Habib Abdelhak;Houari, Hacene
    • Structural Engineering and Mechanics
    • /
    • v.47 no.6
    • /
    • pp.819-838
    • /
    • 2013
  • This paper summarises the results of an experimental study to investigate the flexural behaviour of reinforced concrete beams strengthened using carbon-fibre reinforced polymer (CFRP) laminate in four-point bending. The experimental parameters included are the reinforcing bar ratio ${\rho}_s$ and preload level. Four bar ratios were selected (${\rho}_s=0.13$ to 0.86%), representing the section of two longitudinal tensile reinforcements, with diameters of 8, 14, 16, and 20 mm in order to reveal the effect of bar ratio on failure load and failure mode. Eight beams that could be considered "full-scale" in size, measuring 200 mm in width, 400 mm in total height and 2300 mm in length, were tested. Three beams were selected with different bar ratios (${\rho}_1$, ${\rho}_2$, ${\rho}_3$), and considered as control specimens (without ), while three other beams identical to the control beams with the same CFRP laminates ratio and a seventh beam with ${\rho}_{min}$ (the lowest bar ratio) were also used. In the second part of the study, two beams with the bar ratio ${\rho}_2$ were preloaded at two levels, 50 and 100% of their ultimate loads, and then repaired. This experimental investigation was consolidated using an analytical model. The experimental and analytical results indicate that the flexional capacity and stiffness of strengthened and repaired beams using CFRP laminate were increased compared to those of control beams, and the behaviour of repaired beams was nearly similar to the undamaged and strengthened beams; unlike the ductility of strengthened beams, which was greatly reduced compared to the control.

Analysis on the Pitch Response Spectra of a Catamaran with Bulb (벌브를 가진 쌍동형 선박의 종동요 응답 스펙트럼 분석)

  • Seo, Kwang-Cheol;Lee, Chang-Woo;Atlar, Mehmt;Lee, Gyoung-Woo;Gim, Ok-Sok
    • Journal of Navigation and Port Research
    • /
    • v.37 no.5
    • /
    • pp.481-486
    • /
    • 2013
  • In this study, a commercial seakeeping program Seakeeper, integrated into Maxsurf, which is based on the linear strip theory was employed to compare the effect of bulbous bow (with/without) on motion response characteristics in a 18-meter catamaran. The seakeeping analyses were conducted at several Beaufort wind conditions such as scale No. 3 ($\bar{T}=2.98s$, $H_{1/3}$ =0.6m), No. 4 ($\bar{T}=3.85s$, $H_{1/3}$ =1m) and No. 5 ($\bar{T}=5.44$, $H_{1/3}$ =2m) based on ITTC wave spectrum. Pitch motion response spectrum was calculated at Head sea, Head & bow sea and Beam sea as encounter angles. Hull form of a catamaran with bulb showed the maximum 20% decrease of pitch motion response as compared to that of hull form without bulb.

Development of 2-ton thrust-level sub-scale calorimeter (추력 2톤급 축소형 칼로리미터 개발)

  • Cho, Won-Kook;Ryu, Chul-Sung;Chung, Yong-Hyun;Lee, Kwang-Jin;Kim, Seung-Han;Lee, Soo-Yong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.33 no.3
    • /
    • pp.107-113
    • /
    • 2005
  • A calorimeter of 2-ton thrust level rocket engine chamber has been developed to measure the wall heat flux. The liner of the chamber is made of copper-chromium alloy to maximize the heat transfer performance and structural strength. 1-D design code based on empirical correlations has been used for the prediction of the global thermal characteristics while 3-D CFD has been applied for the verification of local cooling performance. The predicted average wall heat flux at the throat is 43 $MW/m^{2}$ for the combustion chamber pressure of 53 bar. The chamber structure is confirmed to be safe at the pressure of 150 bar through 2-D stress analysis and measurement of the strain of the test species. Finally, the test of pressurizing the calorimeter chamber has been performed with water at the pressure of 150 bar in room temperature environment. No thermal damage has been detected after the hot-fire test in the test nozzle of same cooling performance with the developed calorimeter though the measured throat heat flux is higher than the design value by 10%.

A Study on Improving the Utilization of Biotope Area Ratio System Considering the Plant Growth Conditions (작물 생장조건을 고려한 생태면적률 제도 개선 방향)

  • Lee, Gunwon;Jeong, Yunnam;Ji, Seongkyun;Kim, Seiyong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.2
    • /
    • pp.1490-1499
    • /
    • 2015
  • The purpose of this study is to improve Biotope Area Ratio(BAR) systems used in the various fields. Recently, there has been increasing demand in urban agriculture as well as more residents cultivating farms on a small scale. However, there are few measures in terms of architecture and urban planning to respond to this trend. In this sense, this research is effective as it can respond to these demands by using BAR systems. Yet, the environmental indexes are not enough since BAR systems only take account of vegetation. Therefore, this study proposes an alternative way that includes the capacity factor of the plant growth by expanding the existing BAR systems. Thus, the study analyzes the complementary possibility of BAR systems, including elements of daylight, planting interval, area and soil depth with existing BAR elements.

Combustion Test Results of 1/2.5-scale Thrust Chamber for 75tonf-Class Liquid Rocket Engine (75톤급 액체로켓엔진 1/2.5-scale 연소기 연소시험 결과)

  • Kim, Jong-Gyu;Han, Yeoung-Min;Lee, Kwang-Jin;Lim, Byoung-Jik;Ahn, Kyu-Bok;Kim, Mun-Ki;Seo, Seong-Hyeon;Choi, Hwan-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.69-73
    • /
    • 2009
  • Combustion test results of 1/2.5-scale thrust chamber for 75tonf-class liquid rocket engine were described. The thrust chamber has chamber pressure of 60 bar, propellant mass flow rate of 89 kg/s, and nozzle expansion ratio of 12. The combustion tests were conducted to verify the combustion performance, the regenerative cooling performance and the durability of thrust chamber at design point condition, and then were performed to confirm the operation and the combustion performance at low combustion pressure condition. All the tests had been successfully executed without the damage of the hardware. These test results present a possibility of hot firing test at low combustion pressure condition, and can be used as fundamental data to predict the combustion performance at design point condition for 75 tonf thrust chamber.

  • PDF