• Title/Summary/Keyword: Saturation percentage

Search Result 97, Processing Time 0.028 seconds

A Study on Implemention of Pulse Oximeter System (펄스옥시미터 개발에 관한 연구)

  • Park, Y.S.;Kim, K.E.;Lim, H.S.;Yang, D.G.;Huh, W.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1993 no.05
    • /
    • pp.116-119
    • /
    • 1993
  • In this paper, we implemented a pulse wave type oximeter system that continuously measure the of oxyhemoglobin saturation of the arterial blood(SaO2) and pulse rate with non-invasively. We use the transmission type and reflection type transducer for comparison the percentage of hemoglobin oxgen saturation. The light Iron the two kind of LEDs is transmitted through the tissue, then received by a single photodiode with alternatively. By the phase sensitive detection circuit, the output of the photodiode is separated in to red and near infrared signal. We calculated a ratio of light transmittance between two kind of LEDs, and then, it is applied to the oxgen saturation coefficent calculation formular.

  • PDF

The Effects of Breathing Exercise on Respiratory Synergist Muscle Activity and SpO2 in Patients with Chronic Obstructive Pulmonary Disease

  • Jeong, Dae-Keun
    • The Journal of Korean Physical Therapy
    • /
    • v.27 no.4
    • /
    • pp.234-239
    • /
    • 2015
  • Purpose: This study is not a fragmentary study on characteristics of respiratory synergist when breathing, however it was intended to determine the effect of currently available respiratory exercise and to provide basic clinical information through investigation of oxygen demand and respiratory synergist that mobilizes for respiration during application of respiratory exercise. Methods: Experimental group I was selected from second grade of severity classification of GOLD, which has the highest percentage among patients with COPD, and experimental group II was selected from third grade of severity classification as a clinical sampling. After respiration pursing up lips and diaphragm respiration exercise were mediated together for six weeks, activity of respiratory muscles and oxygen saturation were measured and analyzed. Results: In comparison of change of respiratory synergist and oxygen saturation, activity of respiratory synergist in sternocleidomastoid muscle and scalene muscle showed a meaningful decrease in experimental group I. And, in comparison of change of respiratory synergist and oxygen saturation, activity of respiratory synergist in rectus abdominis muscle showed a meaningful increase in experimental group II. In comparison of change of respiratory synergist and oxygen saturation, activity of respiratory synergist in sternocleidomastoid muscle, scalene muscle, and rectus abdominis muscle showed a meaningful difference between experimental groups. Conclusion: Respiratory synergists work mainly as agonist of chest and upper limbs. Therefore it is very important to lower mobilization of respiratory synergist when breathing. It is considered that a multilateral approach and continued clinical research for improvement of respiratory function for patients with COPD will be needed in the future.

The Comparison of Electrical Conductivity for Soil Solutions Extracted in Field Capacity and Saturation-Paste (포장용수량과 포화 반죽 토양용액의 전기전도도 비교)

  • Lee, Ye-Jin;Lee, Jong-Sik;Yang, Jae-E.
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.43 no.6
    • /
    • pp.776-781
    • /
    • 2010
  • Estimating the electrical conductivity of the saturation-paste (SP) is a common method to assess soil salinity. To assess soil salinity realistically, it is important to extract soil solution under field capacity. However, few studies on salinity assessment have been conducted for soil solution extracted under field capacity (-33 kPa; FC) moisture condition due to difficulty in soil solution extraction. This study was conducted to evaluate whether saturation-paste can represent field condition. Soil solutions were extracted from 22 soils in the plastic film house (PFH) and 18 soils in the reclaimed land (RL) at saturation and field capacity moisture conditions. Those were analyzed for pH, EC, cations ($K^+$, $Ca^{2+}$, $Mg^{2+}$, $Na^+$) and anions ($Cl^-$, ${NO_3}^-$, ${PO_4}^{3-}$, ${SO_4}^{2-}$). Both cations and anions of soil solution extracted from FC showed high correlations with ions extracted from SP in the PFH and the RL, except for ${NO_3}^-$, ${PO_4}^{3-}$ in the RL. Results of the t-test, the ECe and $EC_{FC}$ were not significant at significance level 0.05. The slopes of the equations between $EC_{FC}$ and ECe at more than sand 50% soils were higher than less than sand 50% soils, and differences of saturation percentage between SP and FC showed larger as increasing sand percentage. EC was related to soil water retention by soil texture. To determine the EC, soil texture and other soil properties which effect the soil moisture should be considered.

Danamic Characteristics of Percentage Differential Relays Considering Saturation Effect (포화현상을 고려한 비율차동계전기의 동특성 해석)

  • Kim, Nam-Ho;Kim, Il-Nam;Lee, Juhn-Chang
    • Journal of Industrial Technology
    • /
    • v.14
    • /
    • pp.89-100
    • /
    • 1994
  • The effects of transient inrush currents on the dynamic characteristics of percentage differential relays are studied when the power transformers are reenergized. An algorithm of estimation the nonlinear magnetic property of power transformer and current trnasformer core are developed. Using this method, we can analyze the effect of inrush currents on the trip region of the percentage differential relays corresponding to the variation of the phase angle and the residual magnetism at the instant of switch closing. Test results are used to verify the availibility of the proposed algorithm. Finally a case study is performed to the 110 MVA main transformer in hydraulic power station.

  • PDF

An Ecological Analysis of Iron Status of Middle School Students in Seoul (중학생의 철분 영양 상태에 영향을 미치는 생태학적 변인 분석)

  • 최주현
    • Journal of Nutrition and Health
    • /
    • v.30 no.8
    • /
    • pp.960-975
    • /
    • 1997
  • This study was carried out to evaluate the iron nutrition status of 212 middle school students(106 males and 106 females) residing in Seoul(13-14 years old ) using eating patterns and a measurement of anthropometrical determination and hematological indices. Fasting blood samples were taken from all subjects, serum iron (SI) and total iron binding capacity(TIBC) concentrations were measured, and transferrin saturation(TS) levels were calculated. Iron and other nutrient intakes were estimated by a semi-quantitative frequency questionnaire. The level of TS(%) which was calculated with TIBC and SI in females(20.4$\mu\textrm{g}$/dl) was significantly lower(p<0.050 than that of males (27.4$\mu\textrm{g}$/㎗). The prevalence of iron deficiency was found to be 36.7% when defined by TS(%) (<05%). Mean daily intake of total iron in the study subjects was 14mg and heme iron intake was 5.4mg(38.1%) . There was a significant negative correlation between the level of SI and the income level and a positive correlation with the level of TIBC and the income level. TIBC had a positive correlation with the anthropometric variables(Ht, Wt, BMI, RI and PIBW). SI and TS had a negative correlation with body fat percentage. There was a positive correlation between energy intake and TIBC only among females. The logistic regression analysis revealed that income level, body fat percentage , weight and energy intake were major determinants of low SI levels. Among the determinants of abnormal TIBC levels were weight , height, income level and energy intake. Finally , among those of low TS% were iron and energy intake and income level. These observations suggest that physical status, body fat percentage energy and iron intakes and income level are risk factors for iron-deficiency anemia among the middle school students in Seoul.

  • PDF

Estimating Saturation-paste Electrical Conductivities of Rose-cultivated Soils from their Diluted Soil Extracts (절화장미 재배토양에서 희석된 토양 침출용액으로부터 포화반죽 전기전도도 추정)

  • Lee, In-Bog;Ro, Hee-Myong;Lim, Jae-Hyun;Yiem, Myoung-Soon
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.33 no.6
    • /
    • pp.398-404
    • /
    • 2000
  • We examined the effect of soil:water ratio on the equivalent concentration of individual electrolyte species and the electrical conductivities (EC) of the diluted extracts of 24 soil samples (loam or silt loam) collected from rose-cultivated plastic houses to estimate the EC of saturated soil-paste extracts (ECe) from diluted soil extracts. With increasing volume ratio of water (higher dilution), the equivalent concentrations of each electrolyte species and their sum increased. The relative contribution to the EC, however, was highest for $NO_3{^-}$, irrespective of soil:water ratio. The measured ECe was 6.36 for loam and $8.09dS\;m^{-1}$ for silt loam soils and the corresponding soil:water ratio was 0.38 and 0.50, respectively. The EC_e estimated from the EC of diluted extracts at 1:1, 1:2, or 1:5 soil:water ratios using their corresponding uniform diluted factors was lower than the measured EC_e and this difference was greater with higher dilution and EC values. Therefore, the alternative diluted factors (y) for each soil: water ratio were obtained following the definition of diluted factor and were correlated significantly with volume ratios of added water (x): y=1.55x+0.5 for loam and y=1.21x+0.48 for silt loam soils. On the other hand, correlation analyses of the EC of soil extracts (y) to the volume ratio of added water (x) on log-log scale yielded linear models: logy = -0.805logx + logb, SD of slope=0.05, b=sample specific constant, n=24). With known saturation percentage of a sample representing a group and and the EC of diluted extract of a given soil, the EC_e could be predicted using the proposed logarithmic equation.

  • PDF

Clinical Characteristics and Polysomnographic Features of Patients Visited a Snoring and Sleep Apnea Clinic of Dental Hospital in Korea

  • Kim, Ji-Rak;Chung, Jin Woo
    • Journal of Oral Medicine and Pain
    • /
    • v.42 no.1
    • /
    • pp.1-7
    • /
    • 2017
  • Purpose: The aims of this study were to evaluate the clinical characteristics and polysomnographic results of patients visited the Seoul National University Dental Hospital (SNUDH) and to suggest guidelines for the management of sleep disordered-breathing patients in a dental clinic. Methods: Five hundred sixty-two patients who visited the Snoring and Sleep Apnea Clinic of SNUDH were evaluated for clinical characteristics including associated comorbidities, age, gender, body mass index (BMI), neck circumference, and daytime sleepiness and among them 217 patients were performed nocturnal polysomnography for evaluating respiratory disturbance index, apnea-hypopnea index (AHI), oxygen saturation levels, and sleep stages. The associations among clinical characteristics, sleep parameters, and positional and rapid eye movement (REM) dependencies of the patients were analyzed. Results: The most common co-morbidities of the patients were cardiovascular (30.2%), endocrine (10.8%), and respiratory diseases (7.9%). Age (${\beta}=0.394$), total AHI (${\beta}=0.223$), and lowest $O_2$ saturation levels (${\beta}=0.205$) were significantly associated with the number of co-morbidities in patients with obstructive sleep apnea (OSA). Mean $O_2$ saturation was not significantly associated with number of co-morbidities. Non-positional OSA patients had higher BMI, longer neck circumferences, more severe AHI values, and lower mean and lowest $O_2$ saturation levels compared to positional OSA patients. Not-REM-related patients were older and had more severe AHI values compared to REM-related patients. Not-REM-related patients have longer duration of stage I sleep and shorter stage II, III, and REM sleep than REM-related patients. There were no significant differences in each sleep stage between positional and non-positional patients. Neck circumference, positional dependency, REM dependency, and percentage of supine position were significantly associated with severity of OSA. Conclusions: Age, total AHI, and lowest $O_2$ saturation level were significantly associated with the number of co-morbidities in patients with OSA. Neck circumference, positional dependency, REM dependency, and percentage of supine position were significantly associated with severity of OSA.

Discussion on Dilution Factor for Electrical Conductivity Measured by Saturation-paste Extract and 1:5 Soil to Water Extract, and CEC of Korean Soils (한국 토양에 대한 포화침출액법과 1:5 법에 의한 전기전도도 간의 희석배수와 CEC의 관계에 대한 고찰)

  • Jung, Yeong-Sang;Joo, Jin-Ho;Hong, Sun-Dal;Lee, In-Bog;Ro, Hee-Myong
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.34 no.1
    • /
    • pp.71-75
    • /
    • 2001
  • Linear regression analyses between the electrical conductivity of the saturation-paste extract. ECe, and the electrical conductivity of the 1:5 soil extract, EC1:5, for different soils yielded different dilution factors, or slopes with significant $r^2$ values from 0.842 to 0.905. The dilution factor was inversely proportional to the cation exchange capacity of soil which reflected textural difference. The dilution factors recommended for different textural classes ranged from 6.44 for clay soil to 12.29 for sandy soil based on the CEC's of the textural classes among 350 surface soils recorded in the Taxonomical Classification of Korean Soils except volcanic ash derived soils. Though saturation percentage of the saturation-paste of the soils in this study, CEC should be taken into account for dilution factor between ECe and EC1:5, and the suggested dilution factors might be reasonable estimate for the soil textural classes.

  • PDF

The Effects of Chest Physiotherapy on Sputum Amount, Lung Compliance, Tidal Volume and Oxygen Saturation of Intensive Care Unit Patients Mechanical Ventilated (흉부물리요법이 인공호흡기환자의 객담량, 폐유순도, 일회호흡량 및 산소포화도에 미치는 효과)

  • Seo, Kyoung-San;Kwon, En-Ok
    • Journal of Korean Critical Care Nursing
    • /
    • v.2 no.1
    • /
    • pp.15-25
    • /
    • 2009
  • Purpose: This study investigated the effects of chest physiotherapies on intensive care unit patients mechanical ventilated. Methods: Good lung down position, chest percussion, postural drainage was applied to patients who admitted to ICU. Each patients divided into four groups and each group received different treatments. Sputum amount, lung compliance, tidal volume and oxygen saturation were measured before treatment and immediately, and time flowing. Data was analyzed with frequency, percentage, ANOVA and paired t-test using via SPSSWIN 12.0 program. Results: There were significant differences in variables each characteristics of subjects. Chest percussion increased tidal volume, static lung compliance for the mean time. Desaturation related to suction. Conclusion: Chest percussion influences on lung compliance. Based on this study results and limitation, this study suggests repeated studies in various groups

  • PDF

The Effect of Long-term Application of Different Organic Material Sources on Chemical Properties of Upland Soil (유기물원이 다른 퇴비연용이 밭토양의 화학성 변화에 미치는 영향)

  • Kim, Jong-Gu;Lee, Kyeong-Bo;Lee, Sang-Bok;Lee, Deog-Bae;Kim, Seong-Jo
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.32 no.3
    • /
    • pp.239-253
    • /
    • 1999
  • The objective of this study was to determine the effects of various kinds of composts on the change of soil chemical properties in upland soils. Field experiments were conducted in the loam and sandy loam soils. Various kinds of composts such as poultry manure compost(PMC), cow manure compost(CMC), human excrement sludge(HES), and food industrial sludge compost(FISC) were applied annually at rates of 0, 40, and $80Mg\;ha^{-1}$ to soils grown with soybean and maize plants for 4 years during 1994 to 1997. The results of this study were as follows : The continuous application of human excrement sludge decreased soil pH up to 4.4~5.0, while other compost treatments increased soil pH compared with control plot. The EC increased initially and showed their maximum values at 20days after compost application, and then decreased up to 40 days, thereafter kept a certain level. The available phosphorous accumulated at 0~20cm depth in loam soil, and 0~50cm in sandy loam soil. Annual accumulation rates were 17% higher in sandy loam soil than loam soil. The more compost application rates and times, the higher base saturation percentage increased in upland soils. Four year's application at a rate of $80Mg\;ha^{-1}$ per year increased the base saturation percentage to 87~91% compared with 45% at control plot in the loam soil. While in sandy loam soil only three year's application of same rate increased the base saturation percentage to 81~92% compared with 30.4% at control plot. The average annual increasing rate of base saturation percentage at the same application rates of composts were higher in sandy loam soil by 2.0~3.7 times than in loam soil. The application of compost increased the exchangeable Ca, Mg, and K contents of soils by 2, 2~3, and 3~5 times, respectively, compared with the control. The contents of exchangeable canons were high in surface soil. and decreased with increase of soil depths. In the case of heavy metal content, there were no difference at the application of PMC and CMC but Ni. Fe, Zn, Cu was increased a little when the HES applied, and Ni and Cr was increased application with FISC.

  • PDF