• Title/Summary/Keyword: Saturation effect

Search Result 1,034, Processing Time 0.029 seconds

Observation of saturation transfer characteristics in solution processed vertical organic field-effect transistors (VOFETs) with high leakage current

  • Sarjidan, M.A. Mohd;Shuhaimi, Ahmad;Majid, W.H. Abd.
    • Current Applied Physics
    • /
    • v.18 no.11
    • /
    • pp.1415-1421
    • /
    • 2018
  • Unlike ordinary organic field-effect transistors (OFETs), saturation current is hardly to be found in vertical OFETs (VOFETs). Moreover, the fabrication process of patterned sourced for VOFETs is quite complex. In this current work, a simple solution processed VOFET with directly deposited intermediate silver source electrode has been demonstrated. The VOFET exhibits a high leakage current that induces an inversion polarity of its transistor behavior. Interestingly, a well-defined saturation current was observed in the linear scale of transfer characteristic. The VOFET operated with high-current density > $280mA/cm^2$ at $V_d=5V$. Overview potential of the fabricated device in display application is also presented. This preliminary work does open-up a new direction in VOFET fabrication and their application.

Study on Transformer and Inductor Using Equivalent Air gap to Partial Flux Saturation (국부적 자속 포화 현상을 이용한 리엑터 및 변압기의 공극 등가 모델에 관한 연구)

  • Park, Sung-Jun;Lee, Sang_Hun;Kim, Jeong-Hun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.17 no.3
    • /
    • pp.103-112
    • /
    • 2014
  • BY the Transformers and reactors, the input electrical energy is converted into magnetic energy. At the end through the magnetic energy was passed at the output parameter. Specially At the flyback transformer or a reactor airgap were designed to contain more magnetic energy. But that work is very difficult for the optimal design. It is that Contradictions are between the length of the Air-gap, Winding inductance, DC bias. As to e Several conflicting conditions in order to determine the optimum Air-gap has a lot of experience and trial & error is necessary. The approach proposed in this paper, the auxiliary winding on the core attached to part of primary core, that by applying a DC voltage has a dramatic effect like Core with designed Air-gap. This inventiveness and advantage is to regulate arbitrarily the Saturation Flux Quantity by the input signal to secondary winding. Accordingly obtained the biggest effect is that increasing limits of the saturation current destined by the material and shape of the conventional core. In other words, that can decreas the size of the transformer and reactor, While maintaining the current saturation capacity. This paper, prove its effect as using the local flux saturation in transformers and reactors for research by the computer program using the finite element method (FEM) simulation, followed by actual experiment to verify

Ammonia Removal Model Based on the Equilibrium and Mass Transfer Principles

  • Yoon, Hyein;Lim, Ji-Hye;Chung, Hyung-Keun
    • Bulletin of the Korean Chemical Society
    • /
    • v.29 no.3
    • /
    • pp.555-561
    • /
    • 2008
  • In air stripping of ammonia from the aqueous solution, a new removal model was presented considering the equilibrium principles for the ammonia in aqueous solution and between the aqueous and air phase. The effects of pH, temperature and airflow rate on the ammonia removal were evaluated with the model. In addition, the saturation degree of ammonia in air was defined and used to evaluate the effect of each experimental factor on the removal rate. As pH (8.9 to 11.9) or temperature (20 to 50 oC) was increased, the overall removal rate constants in all cases were appeared to be increased. Our presented model shows that the degrees of saturation were about the same (0.45) in all cases when the airflow condition remains the same. This result indicates that the effect of pH and temperature were directly taken into consideration in the model equation. As the airflow increases, the overall removal rate constants were increased in all cases as expected. However, the saturation degree was exponentially decreased with increasing the airflow rate in the air phase (or above-surface) aeration. In the subsurface aeration the saturation degree remains a constant value of 0.65 even though the airflow rate was increased. These results indicate that the degree of saturation is affected mainly by the turbulence of the aqueous solution and remains the same above a certain airflow rate.

The effect comparison using saturation tone signals for optical wavelength division multiplexing communications (32 채널 파장분할다중화 광통신 전송에서 이득포화 광신호 영향 비교)

  • Choi, Bo-Hun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.8
    • /
    • pp.2037-2042
    • /
    • 2014
  • Three methods for gain saturation tone application were compared for optical wavelength division multiplexing transmission using more than 32 channels. The methods are to use high power distributed feedback laser diodes, to use amplified light sources, and lastly to use one saturation tone and several WDM light sources. 1532.3 nm, 1545.7 nm, and 1558.2 nm for the wavelength dependency of the saturation tone were also compared. As a result, the effect of amplified spontaneous emission noise caused by an amplifier was very slight. long wavelength for a saturation tone caused 1 dB gain reduction and its reason was analyzed.

Transient Response Analysis of DC Voltage Regulating System with Amplidyne Saturation Effect (Amplidyne의 포화현상을 고려한 직류정전압계통의 과도응답 해석)

  • 이승원;김남호
    • 전기의세계
    • /
    • v.26 no.6
    • /
    • pp.55-58
    • /
    • 1977
  • This paper deals with the transient analysis of an amplidyne dc voltage regulating system under the following conditions: (1) assuming all the components of the system to be linear, (2) considering the effect of amplidyne saturation. The mathematical technique employed is state variables method. The calculated response curves are compared with the experimental results obtained on a practical system. The main results can be summerized as follows: 1) The effect of amplidyne saturation on the transient response of a dc voltage regulating system is to reduce the overshoot and setting time. 2) With the increase in level of the step reference voltage, the system response becomes apesiodic. 3) The steady output voltage is reduced appreciably compared to the linear case.

  • PDF

THE EFFECT OF OVER AND UNDERLAYER ON THE MAGNETORESISTANCE IN Co-Ag NANO-GRANULAR ALLOY FILMS

  • Kim, Yong-Hyuk;Lee, Seong-Rae
    • Journal of the Korean Magnetics Society
    • /
    • v.5 no.5
    • /
    • pp.451-455
    • /
    • 1995
  • The composition and thickness dependence and the ferromagnetic under- and overlayer effect on the magnetoresistance ratio and saturation field of the Co-Ag nano-granular films were investigated. The maximum magnetoresistance (23% at R.T.) in the as-deposited state was obtained in the $3000{\AA}$ $Co_{30} Ag_{70}$ bare alloy film. As the thickness of the alloy films decreased below $500{\AA}$, the MR ratio decreased because of the resistivity increase and the non-uniform film formation. We showed that the ferromagnetic over- and underlayer could reduce the saturation field of the nano-granular films via exchange coupling effect. The magnetoresistance and the saturation field of the $100{\AA}$ alloy film were 3.65 % and 2.85 kOe respectively and those of the under- and overlayered alloy films with $200{\AA}$ Fe were 3.3 % and 1.23 kOe respectively.

  • PDF

Performance Analysis of a Lowpass Filter on a CT Saturation Detection Algorithm (변류기 포화 판단 알고리즘의 저역통과 필터에 대한 성능 분석)

  • Gang, Yong-Cheol;Ok, Seung-Hwan;Yun, Jae-Seong;Gang, Sang-Hui
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.51 no.10
    • /
    • pp.495-501
    • /
    • 2002
  • A difference based current transformer (CT) saturation detection algorithm uses the third difference of a secondary current to detect the instants of the beginning/end of saturation. The third difference of a secondary current contains high frequency components when a CT is saturated. Thus, an effect of an anti-aliasing lowpass filter implemented in digital protection relays on the detection algorithm should be studied. This paper describes performance analysis of a lowpass filter on the CT saturation detection algorithm. The cutoff frequency of the lowpass filter is normally set to be half of a sampling frequency. In this Paper, two sampling frequencies of 3,840 (Hz) corresponding to 64 sample/cycle (s/c) and 1,920 (Hz) corresponding to 32 (s/c) are studied; the cutoff frequencies of the lowpass filters are set to be 1,920 (Hz), 960 (Hz) and 960(Hz), 480(Hz), respectively. And the proposed algorithm is verified by experiment. A 2nd order Butterworth filter is designed as a lowpass filter. The test results and experiment results clearly indicate that the saturation detection algorithm successfully detects the instants of the beginning/end of saturation even though a secondary current is filtered by the designed lowpass filters.

Influence of time delay and saturation capacity to the response of controlled structures under earthquake excitations

  • Pnevmatikos, Nikos G.;Gantes, Charis J.
    • Smart Structures and Systems
    • /
    • v.8 no.5
    • /
    • pp.449-470
    • /
    • 2011
  • During the last thirty years many structural control concepts have been proposed for the reduction of the structural response caused by earthquake excitations. Their research and implementation in practice have shown that seismic control of structures has a lot of potential but also many limitations. In this paper the importance of two practical issues, time delay and saturation effect, on the performance of controlled structures, is discussed. Their influence, both separately and in interaction, on the response of structures controlled by a modified pole placement algorithm is investigated. Characteristic buildings controlled by this algorithm and subjected to dynamic loads, such as harmonic signals and actual seismic events, are analyzed for a range of levels of time delay and saturation capacity of the control devices. The response reduction surfaces for the combined influence of time delay and force saturation of the controlled buildings are obtained. Conclusions regarding the choice of the control system and the desired properties of the control devices are drawn.

Effect for Eefficiency of Variable Speed Control of Magnetic Saturation in Induction Machine (유도전동기의 자기적 포화가 가변속 제어의 효율에 미치는 영향)

  • Jeong, Jong-Ho;Yun, Seo-Jin;Lee, Eun-Woong;Moon, Jae-Yun
    • Proceedings of the KIEE Conference
    • /
    • 1998.07a
    • /
    • pp.52-54
    • /
    • 1998
  • In this paper, analytically presented the magnetic saturation impact on the efficiency of induction motor. Especially, in this study concerned with various cases such as included magnetic saturation, constant flux.

  • PDF

Analysis of Saturation Flow Rate on Interrupted Flow During Rainfall (강우시 단속류 포화교통류율 변화 분석)

  • Kim, Bongseok;Roh, Chang-Gyun;Son, Bongsoo
    • Journal of Korean Society of Transportation
    • /
    • v.33 no.1
    • /
    • pp.90-99
    • /
    • 2015
  • The climate of Korea has clear rainy and dry season due to seasonal wind. In general, The rainy season in Korea is from early summer through to early fall. And precipitation accounted for more than half of the total annual rainfall in this period. This study is aiming to analysis of variation in saturation flow rate at signalized intersection during rainfall. The range of spatial is urban signalized intersections in Seoul and temporal is rainfall or ideal condition in daylight. Traffic data are collected through CCTV of Seoul Metropolitan Police Agency, and on-site video recordings directly. Weather condition data are collected from the Korea Meteorological Administration. In addition, the value of saturation headway and saturation flow rate, in rainfall condition, are derived through video frame analysis. As a results of analysis, decrease of saturation flow rate and increase of saturation headway during rainfall were confirmed by comparison with non-rainfall. The higher rainfall rate is, the more decreased saturation flow rate at the intersections. Rainfall rate is divided three area by the results of statistical test, and saturation flow rate decrease 7%, 17%, 21%, respectively.