• 제목/요약/키워드: Saturation Vapor Pressure

검색결과 63건 처리시간 0.025초

오블롱 셀 플레이트 열교환기에서의 R-l34a, R-407C, R-410A의 증발 압력강하에 관한 실험적 연구 (Study on Evaporation Pressure Drop of R- l34a, R-407C, and R-410A in the Oblong Shell and Plate Heat Exchanger)

  • 박재홍;김영수
    • 설비공학논문집
    • /
    • 제16권9호
    • /
    • pp.855-862
    • /
    • 2004
  • This study reports pressure drops during evaporation for R-l34a, R-407C (a mixture of 23 wt% R-32, 25 wt% R-125, and 52 wt% R-l34A) and R-410A (a mixture of 50 wt% R-32 and 50 wt% R-125) in the oblong shell and Plate heat exchanger. The effects of the mass fluxes, heat fluxes, refrigerant saturation temperatures and vapor quality of refrigerants on the measured data were explored in detail. The present data showed that pressure drops of all refrigerants increase with the vapor quality. At a higher mass flux, pressure drops are higher for the entire range of the vapor quality A rise in the heat flux doesn't show significant effects on the pressure drops. Finally, at a higher saturation temperature the pressure drops are found to be lower. The pressure drops for R-407C were approximately 20% lower than those of R-l34a. R-410A had 33% lower pressure drops than R-l34a. Correlation is also provided for the measured pressure drops in terms of the friction factor.

액상부탄 분사시스템의 수치시뮬레이션 및 분무특성 예측 (Simulation of Fuel Injection System and Model of Spray Behavior in Liquefied Butane)

  • 김종현;구자예
    • 한국분무공학회지
    • /
    • 제3권2호
    • /
    • pp.24-33
    • /
    • 1998
  • The characteristics of liquefied butane spray are expected to be different from conventional diesel fuel spray, because a kind of flash boiling spray is expected when the back pressure is below the saturation vapor pressure of the butane(0.23MPa at $25^{\circ}C$). An accumulator type pintle injector and its fuel delivery system has been simulated in ruder to give injection pressure, needle lift and rate of fuel injected. The governing equation were solved by finite difference metho. The injection duration was controlled by solenoid valve. Spray behaviors such as a transient spray tip penetration, spray angle and SMD were calculated based on the empirical correlations in case that the back pressure is both above the vapor pressure of the butane and below that of butane. When the back preassure is below the vapor pressure of the fuel, conventional correlation is modified to represent the effect of flash boiling.

  • PDF

신경회로망을 사용한 냉매의 함수근사 (Function Approximation for Refrigerant Using the Neural Networks)

  • 박진현;이태환
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2005년도 추계종합학술대회
    • /
    • pp.677-680
    • /
    • 2005
  • 유체의 상변화를 이용하는 냉난방장치 등의 열장치에 대한 열역학적인 성능평가는 열역학적 성질들에 대한 구체적인 수치값을 필요로 한다. 그러나 이러한 열역학적 성질들을 제공하는 증기표를 그대로는 사용할 수 없기 때문에 효과적인 모델링이 필요하다. 본 연구에서는 신경회로망의 함수근사 특성을 이용하여 냉방장치의 매질로 사용되는 냉매(R12)의 포화증기 영역을 모델링하였다. 냉매 R12의 포화증기 영역의 함수근사 해석을 위하여 1개의 노드를 가진 입력층에 대하여 7개의 노드를 가진 출력층을 기본으로 하여, 각각 10개와 20개의 노드를 가진 두 개의 은닉층을 가진 회로망을 구성하였다. 또한 입력이 온도와 압력 두 가지의 경우에 대하여 검토하였다. 제안된 신경회로망을 사용한 결과 엔탈피, 엔트로피의 백분율오차가 대부분 ${\pm}$0.005%, 비체적은 ${\pm}$0.02%, 압력과 온도는 특별한 몇 개를 제외하고는 ${\pm}$0.02% 범위 내로 수렴되었다. 이 결과로부터 냉매를 함수근사하는데 있어서 신경회로망이 아주 강력한 수단이 될 수 있음을 확인하였다.

  • PDF

지표자료와 구름물리를 토대로 한 호우모형의 개선에 관한 연구 (A Study on the Improvement of Heavy Rainfall Model Based on the Ground Surface Data and Cloud Physics)

  • 김운중;이재형
    • 물과 미래
    • /
    • 제28권6호
    • /
    • pp.229-236
    • /
    • 1995
  • 강수의 물리과정에 입각한 호우모형이 전일권(1994)에 의하여 개발되었다. 본 논문에서 이를 수정하였다. 본는 연구 모형에서 구성한 주요 부분은 포화증기압, 구름두께, 운정기압에 관한 것이다. 기존 모형과 달리 본 연구 모형의 입력자료로써 위성에 의해 측정된 운정기온과 알베도를 사용하였다. 본 연구에서 기존의 포화증기압 방정식보다 현실에 가까운 방정식을 획득하였으며 기존 방정식의 단점을 해결하였다. 또한 운정기온과 운정기압 추정에 사용된 매개변수가 소거되었으며 계산시간도 단축되었다. 본 연구 모형을 전주지점의 호우사상에 적용하여 검증한 결과 모형의 출력인 총강우량과 강우 패턴이 실측치에 잘 부합되었다.

  • PDF

수평관내 이산화탄소의 증발 압력강하 (Evaporation Pressure Drop of Carbon Dioxide in a Horizontal Tube)

  • 구학근;손창효
    • 동력기계공학회지
    • /
    • 제11권1호
    • /
    • pp.63-69
    • /
    • 2007
  • The evaporation pressure drop of $CO_2$ (R-744) in a horizontal tube was investigated experimentally. The main components of the refrigerant loop are a receiver, a variable-speed pump, a mass flow meter, a pre-heater and an evaporator (test section). The test section consists of a smooth, horizontal stainless steel tube of 4.57 mm inner diameter. The experiments were conducted at saturation temperature of $-5^{\circ}C\;to\;5^{\circ}C$, and heat flux of 10 to $40kW/m^2$. The test results showed that the evaporation pressure drop of $CO_2$ are highly dependent on the vapor quality, heat flux and saturation temperature. The measured pressure drop during the evaporation process of $CO_2$ increases with increased mass flux, and decreased saturation temperature. The evaporation pressure drop of $CO_2$ is much lower than that of R 22. In comparison with test results and existing correlations, the best fit of the present experimental data is obtained with the previous correlation. But existing correlations failed to predict the evaporation pressure drop of $CO_2$. Therefore, it is necessary to develop reliable and accurate predictions determining the evaporation pressure drop of $CO_2$ in a horizontal tube.

  • PDF

액체-증기 이젝터의 성능에 관한 실험적 연구 (An Experimental Study on the Performance of a Liquid-Vapor Ejector with Water)

  • 박대웅;정시영
    • 설비공학논문집
    • /
    • 제12권4호
    • /
    • pp.345-353
    • /
    • 2000
  • In this study, the performance of five ejectors has been investigated with working fluids of water and water vapor. The diameters of nozzle and mixing tube of five ejectors were 1 and 1.5(ejector A), 1 and 2(ejector B), 1 and 2.5(ejector C), 1 and 3(ejector D), 2 and 4(ejector E) in millimeters. The length of the mixing tube was 8-10 times of its diameter. For each ejector, the ratio of mass flow rate of ejected water to that of entrained water vapor, $\mu$, was evaluated in terms of evaporator pressure, mass flow rate of ejected water, and water temperature. It was found that the performance of an ejector was not stable when the ratio of diameters was too small or too large(ejector A and D) and $\mu$ was almost the same for two ejectors with the same diameter ratio(ejector B and E). It was also found that $\mu$ increased almost linearly with an increase of evaporator pressure and the ratio $\mu$ increased as water temperature decreased. As expected, $\mu$ converged to zero as the water temperature approached the evaporator temperature. Finally, a non-dimensional correlation has been developed to predict$\mu$ terms of evaporator pressure and saturation pressure of ejected water.

  • PDF

산업체 열병합발전 시스템의 최적설계

  • 정병석;노승탁
    • 대한기계학회논문집
    • /
    • 제5권2호
    • /
    • pp.151-157
    • /
    • 1981
  • The concept of available evergy has been adopted in terms of effectiveness for and evaporator of vapor power cycle. This kind of practice is emphasezed in a case of heat and power cogeneration in order to find optimum condition for the energy utilzation of the exhaust gas. It has beed shown that the optimum condition can be given in terms of the saturation pressure or the saturation temperature of the working fluid. Similar method has been applide to show that the effectiveness is increased asymptotically with the number of evaporator stanges.

고온 항공유의 오리피스 인젝터 분사특성 수치해석 (Numerical Simulation of Orifice Injection Characteristics of High Temperature Aviation Fuel)

  • 황성록;이형주
    • 한국분무공학회지
    • /
    • 제28권2호
    • /
    • pp.89-96
    • /
    • 2023
  • This study presents a numerical simulation investigating hydrodynamic characteristics of high-temperature hydrocarbon aviation fuel injected through a plain orifice injector. The analysis encompassed the temperature range up to the critical point, and the obtained results were compared with prior experimental observations. The analysis unveiled that the injector's exit pressure remains equivalent to the ambient pressure when the fuel injection temperature is below the boiling point. However, when the fuel temperature surpasses the boiling point, the exit pressure of the injector transitions to the saturated vapor pressure corresponding to the fuel injection temperature. Consequently, the exit pressure of the injector increases in tandem with the rapid increase of the saturation vapor pressure due to escalating fuel temperatures. This rise in the exit pressure necessitates a proportional increase in fuel injection pressure to ensure a fixed fuel mass flow rate. Furthermore, the investigation revealed that the discharge coefficient obtained by applying the exit pressure instead of the ambient pressure did exhibit no decrease, but rather was maintained at a nearly constant value, comparable to its level below the boiling point.

물의 상평형 그림에 대한 오해와 이해: 대기 중 물의 증발과 얼음의 승화 (Misunderstanding and Understanding of the Phase Diagram for Water: Water Evaporation and Ice Sublimation in the Atmosphere)

  • 박종윤
    • 대한화학회지
    • /
    • 제51권6호
    • /
    • pp.577-584
    • /
    • 2007
  • 본 연구에서는 대기 중에서 물의 증발이나 얼음의 승화와 같은 물의 상태 변화를 물의 상평형 그 림을 이용하여 어떻게 설명할 수 있는지를 제시하고자 하였다. 물의 상평형 그림은 1성분계의 상평형을 나타 낸 것이므로 원칙적으로 물만 존재하는 경우에 사용할 수 있는 것이다. 공기가 존재하는 경우에는 액체 물 또 는 고체 얼음이 있으면 항상 공기 중에 수증기가 공존하게 되며, 이 때 물 또는 얼음의 압력은 공기 중 수증 기의 부분 압력과 일치하지 않기 때문에 상평형 그림에 하나의 점으로 그 상태를 나타낼 수 없다. 그러나 공 기가 존재하는 경우에도 포화 수증기압은 물만 존재하는 경우와 거의 차이가 없으므로 상평형 그림의 증기 압 력 곡선과 승화 곡선을 이용하여 대기 중에서 물의 증발과 얼음의 승화를 설명할 수 있음을 논의하였다.

공기 상태량에 대한 습공기 밀도 계산 (Moist Air Density Calculation for Air Condition)

  • 김종우
    • 대한기계학회논문집 C: 기술과 교육
    • /
    • 제2권2호
    • /
    • pp.105-111
    • /
    • 2014
  • 지구를 둘러싸고 있는 대기의 하층 부분을 구성하는 기체를 보통 공기라 말한다. 지상 20km 이하에서는 그 성분이 거의 일정한 비율로 존재하며, 질소, 산소, 기타 혼합기체로 구성된다. 공기밀도란 단위 부피 중에 포함된 공기의 질량을 말한다. 공기는 거의 일정한 성분으로 조성된 혼합기체이지만, 수증기는 변동이 큰 성분의 하나이다. 같은 온도, 같은 압력에서는 습공기의 밀도가 건공기의 밀도보다 작다. 보통 밀도는 압력이나 온도 변화에 따라 변화된다. 따라서 풍량 계산에 사용되는 중요 인자인 공기 상태량에 따른 밀도 계산과정과 actual air flow 와 standard air flow 의 관계를 살펴 보고자 한다.