• Title/Summary/Keyword: Saturation Curve

Search Result 224, Processing Time 0.026 seconds

Performance Analysis of the Flooded Refrigerant Evaporators for Large Tonnage Compression-Type Refrigerators Using Alternative Refrigerants (대체냉매를 적용한 대형 압축식 냉동기의 만액식 증발기에 대한 성능 해석)

  • Kim, Nae-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.6
    • /
    • pp.18-25
    • /
    • 2016
  • Enhanced tubes are used widely in the evaporators of large tonnage compression-type refrigerators. The evaporators consist of tube bundles, and the refrigerant properties are dependent on the locations in the tube bundles. In particular, the saturation temperatures of low pressure refrigerants (R-11, R-123) are strongly dependent on the locations due to the saturation temperature-pressure curve characteristics. Therefore, for the proper design of evaporators, local property predictions of the refrigerants are necessary. In this study, a computer program that simulates the flooded refrigerant evaporators was developed. The program incorporated theoretical models to predict the refrigerant shell-side boiling heat transfer coefficients and pressure drops across the tube bundle. The program adopted an incremental iterative procedure to perform row-by-row calculations over the specified incremental tube lengths for each water-side pass. The program was used to simulate the flooded refrigerant evaporator of the "T" company operating with R-123, which yielded satisfactory results. The program was extended to predict the performance of the flooded refrigerant evaporator operating with R-11, R-123, and R-134a. The effects of bundle aspect ratio are investigated.

Radiant Energy Filtering to Enhance High Temperature Measurement by a Thermography System (고온 계측 열화상 시스템 구현을 위한 복사에너지 필터링 연구)

  • Yoon, Seok Tae;Cho, Yong Jin;Jung, Ho Seok
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.36 no.6
    • /
    • pp.466-473
    • /
    • 2016
  • In a shipbuilding process, thermal damage to the ship structure at the rear end results from an excessive heat input and conduction during welding process. To prevent such damage, appropriate control of the heat input, based on welding temperature measurement, is required. For temperature measurement, contact and non-contact methods are available; the thermography system is a popular non-contact temperature measurement. When the intensity of radiation from a high-temperature object is excessive, however, detecting the sensors of ordinary thermography systems leads to an inability in measuring the temperature due to saturation. Hence, this study suggests use of a neutral density filter that prevents an excessive amount of radiation from being accumulated in a thermography system, and thus makes it possible to quantitatively measure an object's temperature as high as $3000^{\circ}C$.

Methodologies to Improve Emotional Image Qualities by Optimizing Technological Image Quality Metrics (기술적인 화질 지표 조절양 최적화를 통한 감성 화질 향상 방안)

  • You, Jae-Hee
    • Science of Emotion and Sensibility
    • /
    • v.20 no.1
    • /
    • pp.57-66
    • /
    • 2017
  • Emotional image quality optimization methodologies are investigated using technological image quality controls based on the eye tests of various image samples. The images are evaluated based on various contrast, lightness and saturation image quality metric tone curves. The order of importance to image quality enhancements is contrast, saturation and brightness. The slopes of emotional image qualities with respect to technical image quality metric changes are found to be composed of mathematical function modelling with nearly zero, intermediate and maximum slope regions in general, which can reflect well known log and saturated as well as conventional reverse U shape natures. Image quality improvements are analyzed not only with just single but also with multiple image quality metrics. To ease the unified image quality metric analysis and control, a new function is presented to utilize both the newly found and conventional emotional image quality behaviors. It is found that the overall image quality enhancement can be realized only in a few limited cases of multiple image quality metric controls. It is also found that the kinds of image quality enhancement methodologies are not strongly dependent on image contents (genre).

Experimental Study on Capacity Variation of Paving Materials with TiO2 in Wet Condition (광촉매 이산화티타늄(TiO2)을 혼합한 도로 포장재의 습윤 조건에서의 성능 변화에 관한 실험적 연구)

  • Seo, Dawa;Yun, Tae Sup
    • Journal of the Korean Geotechnical Society
    • /
    • v.32 no.5
    • /
    • pp.49-55
    • /
    • 2016
  • This study aims to present the practical Nitrogen monoxide (NO) removal capacity of cement mortar with Titanium dioxide ($TiO_2$) which is one of the paving materials by considering the environment of pavement in urban areas. NO removal capacity test under designated conditions of humidity of inflow gas and the test with variation of the degree of saturation of specimen were conducted. In the test for humidity, dry specimen is subject to the test and NO removal ratio was observed. Humidity-NO removal ratio curve is a log normal distribution in shape, and the maximum NO removal ratio appears at specific humidity. NO removal capacity test relying on the degree of saturation was carried out with wet specimen to reflect the unsaturated pavement by rainfall and domestic sewage. Wet specimen presents less NO removal capacity than dry specimen and the recovering evolution of NO removal capacity follows evaporation. Moreover, $TiO_2$ under the specific depth of specimen hardly contributes to NO removal capacity.

Dispersion Characteristics of Ag Pastes and Properties of Screen-printed Source-drain Electrodes for OTFTs (Ag Pastes의 분산 특성 및 스크린 인쇄된 OTFTs용 전극 물성)

  • Lee, Mi-Young;Nam, Su-Yong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.9
    • /
    • pp.835-843
    • /
    • 2008
  • We have fabricated the source-drain electrodes for OTFTs by screen printing method and manufactured Ag pastes as conductive paste. To obtain excellent conductivity and screen-printability of Ag pastes, the dispersion characteristics of Ag pastes prepared from two types of acryl resins with different molecular structures and Ag powder treated with caprylic acid, triethanol amine and dodecane thiol as surfactant respectively were investigated. The Ag pastes containing Ag powder treated with dodecane thiol having thiol as anchor group or AA4123 with carboxyl group(COOH) of hydrophilic group as binder resin exhibited excellent dispersity. But, Ag pastes(CA-41, TA-41, DT-41) prepared from AA4123 fabricated the insulating layer since the strong interaction between surface of Ag powder and carboxyl group(COOH) of AA4123 interfered with the formation of conduction path among Ag powders. The viscosity behavior of Ag pastes exhibited shear-thinning flow in the high shear rate range and the pastes with bad dispersion characteristic demonstrated higher shear-thinning index than those with good dispersity due to the weak flocculated network structure. The output curve of OTFT device with a channel length of 107 ${\mu}m$ using screen-printed S-D electrodes from DT-30 showed good saturation behavior and no significant contact resistance. And this device exhibited a saturation mobility of $4.0{\times}10^{-3}$ $cm^2/Vs$, on/off current ratio of about $10^5$ and a threshold voltage of about 0.7 V.

Electrical and Retention Properties of MFSFET Device (MFSFET 소자의 전기적 및 리텐션 특성)

  • Chung, Yeun-Gun;Kang, Seong-Jun;Joung, Yang-Hee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.3
    • /
    • pp.570-576
    • /
    • 2007
  • In this study, the characteristics of metal-ferroelectric-semiconductor FET (MFSFET) device is investigated using field-dependent polarization and square-law FET models. From drain current with the gate voltage variation, when coercive voltages of ferroelectric thin film are 0.5 and 1V, the memory windows are 1 and 2V, respectively. When the gate voltages are 0, 0.1, 0.2 and 0.3V, the difference of saturation drain currents of the MFSFET device at two threshold voltages in ID-VD curve are 1.5, 2.7, 4.0, and 5.7mA, respectively. As a result of the analysis for drain currents after tine lapse, which is based on the simulation for hysteresis loop and the fitting of retention properties of ferroelectric thin films such as PLZT(10/30/70), PLT(10) and PZT(30/70) thin film shows excellent reliability that the decrease of saturation current is about 18% after 10 years.

Cerebral Oxygenation during Apnea in Preterm Infants: Effects of Accompanying Peripheral Oxygen Desaturation

  • Choi, Seo Hee;Lee, Juyoung;Nam, Soo Kyung;Jun, Yong Hoon
    • Neonatal Medicine
    • /
    • v.28 no.1
    • /
    • pp.14-21
    • /
    • 2021
  • Purpose: Premature infants have immature respiratory control and cerebral autoregulation. We aimed to investigate changes in cerebral oxygenation during apnea with and without peripheral oxygen desaturation in premature infants. Methods: This prospective observational study was conducted at Inha University Hospital. Near-infrared spectroscopy (NIRS)-monitored regional cerebral oxygen saturation (rScO2) and pulse oximeter-monitored peripheral oxygen saturation (SpO2) were assessed during the first week of life in 16 stable, spontaneously breathing preterm infants. Apneic episodes that lasted for ≥20 seconds or were accompanied by desaturation or bradycardia were included for analysis. The average rScO2 value during the 5-minute prior to apnea (baseline), the lowest rScO2 value following apnea (nadir), the time to recover to baseline (recovery time), the area under the curve (AUC), and the overshoot above the baseline after recovery were analyzed. Results: The median gestational age and birth weight of the infants were 29.2 weeks (interquartile range [IQR], 28.5 to 30.5) and 1,130 g (IQR, 985 to 1,245), respectively. A total of 73 apneic episodes were recorded at a median postnatal age of 2 days (IQR, 1 to 4). The rScO2 decreased significantly following apneic episodes regardless accompanied desaturation. There were no differences in baseline, nadir, or overshoot rScO2 between the two groups. However, the rScO2 AUC for apnea with desaturation was significantly higher than that for apnea without desaturation. Conclusion: Cerebral oxygenation can significantly decrease during apnea, especially when accompanied by reduced SpO2. These results add the evidence for the clinical utility of NIRS in monitoring premature infants.

Iron deficiency anemia as a predictor of coronary artery abnormalities in Kawasaki disease

  • Kim, Sohyun;Eun, Lucy Youngmin
    • Clinical and Experimental Pediatrics
    • /
    • v.62 no.8
    • /
    • pp.301-306
    • /
    • 2019
  • Purpose: Coronary artery abnormalities (CAA) are the most important complications of Kawasaki disease (KD). Iron deficiency anemia (IDA) is a prevalent micronutrient deficiency and its association with KD remains unknown. We hypothesized that presence of IDA could be a predictor of CAA. Methods: This retrospective study included 173 KD patients, divided into 2 groups according to absence (group 1) and presence (group 2) of CAA. Odds ratios (ORs) with 95% confidence intervals (CIs) were calculated using a logistic regression model to estimate the association between CAA and other indicators. Due to collinearity between indicators of IDA, each indicator was paired with anemia in 3 models. Results: Serum iron, iron saturation, and ferritin concentration, the 3 indicators of IDA, were significantly higher in group 1 than in group 2. Three sets of models including anemia with iron indicators produced the OR of CAA of 3.513, 3.171, and 2.256, respectively. The 3 indicators of IDA were negatively associated with CAA, by OR of 0.965, 0.914, and 0.944, respectively. The areas under the curve (AUCs) of ferritin concentration, iron saturation, serum iron, anemia, and Kobayashi score were 0.907 (95% CI, 0.851-0.963), 0.729 (95% CI, 0.648-0.810), 0.711 (95% CI, 0.629-0.793), 0.638 (95% CI, 0.545-0.731), and 0.563 (95% CI, 0.489-0.636), respectively. Conclusion: Indicators of IDA, especially ferritin, were highly associated with CAA; therefore, they were stronger predictors of CAA than Kobayashi scores. IDA indicators can be used to predict CAA development and to suggest requirements for early interventions.

Fabrication of Ionization Chamber to Measure the Burnup of Spent Fuel (사용후핵연료 연소도 측정을 위한 이온 챔버 제작)

  • Park, Se-Hwan;Eom, Sung-Ho;Shin, Hee-Sung;Lim, Hye-In;Ha, Jang-Ho;Kim, Han-Soo
    • Journal of Radiation Protection and Research
    • /
    • v.35 no.1
    • /
    • pp.21-25
    • /
    • 2010
  • Burnup of spent fuel should be determined accurately for the safety control of spent fuel. Especially, it is necessary to measure the burnup profile along the nuclear fuel axis. In the present work, an ionization chamber was designed and fabricated to measure the gamma ray profile inside the guide tube of spent fuel. The ionization chamber was composed of three parts; induction part, gas-inlet part, and sensor part. The sensor part had two electrodes; cathode and anode. A guide electrode was considered in the ionization chamber design to make the ionization chamber to be inserted easily into the guide tube. Pure gas (argon and xenon) was inserted into the ionization chamber, and the leakage current and saturation curve were measured to determine the operation characteristics of the ionization chamber. The gamma ray radiation was also measured in relatively high dose environment. The gamma ray profile of the spent fuel will be measured with the ionization chamber.

An Experimental Study on Frost Heaving Pressure Characteristics of Frozen Soils (동결토의 동상팽창압 특성에 관한 실험적 연구)

  • 신은철;박정준
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.2
    • /
    • pp.65-74
    • /
    • 2003
  • Most of land reclamation projects are being implemented along the south and west coastal lines of the Korean Peninsula. The earth structures and in-ground LNG tank, and buildings can be constructed using artificial freezing method on the reclaimed land to control the uplift pressure caused by capillary forces. In this study, upon freezing a saturated soil in a closed-system from the top, a considerable frost heaving pressure was developed. Decomposed granite soils, silty soil, and sandy soil were used in the laboratory freeze test which is sometimes subjected to thermal gradients under closed-systems. A major concern has been the ability to predict the frost heaving pressure over the results of relatively short-term laboratory tests. The frost heaving pressure arising within the soil samples and the temperature of the samples inside were monitored with time elapse. The degree of saturation versus heaving pressure curve is presented for each soil sample and the maximum pressure is closely related to this curve. TDR apparatus was used to measure the volumetric water content by the measurement of unfrozen water contents of frozen soils. Unfrozen water increased in soils containing a high percentage of fine-grained particles. In fine-grained soils with strong attractive farces between soil grains and water molecules, additional water is attracted into the pores leading to further volume changes and ice segregation.