• Title/Summary/Keyword: Saturation

Search Result 4,838, Processing Time 0.035 seconds

Loss Minimization Control of Interior Permanent Magnet Synchronous Motors Considering Self-Saturation and Cross-Saturation

  • Pairo, Hamidreza;Khanzade, Mohammad;Shoulaie, Abbas
    • Journal of Power Electronics
    • /
    • v.18 no.4
    • /
    • pp.1099-1110
    • /
    • 2018
  • In this paper, a loss minimization control method for interior permanent magnet synchronous motors is presented with considering self-saturation and cross saturation. According to variation of the d-axis and q-axis inductances by different values of the d-axis and q-axis components of currents, it is necessary to consider self-saturation and cross saturation in the loss minimization control method. In addition, the iron loss resistance variation due to frequency variation is considered in the condition of loss minimization. Furthermore, the loss minimization control method is compared with maximum torque per ampere (MTPA), unity power factor (UPF) and $i_d=0$ control methods. Experimental results verify the performance and proper dynamic response of the loss minimization control method with considering self-saturation and cross saturation.

Standstill Identification of Magnetic Flux Saturation Model Including Cross-Saturation for Synchronous Motors (상호 포화를 포함한 자기저항 동기 전동기의 자속 포화 모델에 대한 정지 상태 추정 기법)

  • Woo, Tae-gyeom;Park, Sang-woo;Choi, Seung-Cheol;Yoon, Young-Doo;Lee, Hak-Jun;Hong, Chanook;Lee, Jeongjoon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.26 no.5
    • /
    • pp.364-371
    • /
    • 2021
  • A magnetic flux saturation model of Synchronous Reluctance Motors (SynRMs) and a parameter estimation method are proposed at standstill. The proposed magnetic flux model includes the nonlinear relationship between the current and the magnetic flux for self-saturation and cross-saturation. Voltage is injected at standstill to estimate the magnetic flux saturation model. Voltages are injected into the d-axis and q-axis to obtain data on self-saturation. Subsequently, voltages are simultaneously injected into the d-q axis to obtain data on cross-saturation. On the basis of the measured current and the calculated magnetic flux, the parameters of the proposed model are estimated using the least square method (LSM). Simulation and experiment were performed on a 1.5-kW SynRM to verify the proposed method. The proposed model can be used to create a high-efficiency operation table, a sensorless algorithm, and a current controller to improve the control performance of a motor.

Adaptive Saturation Enhancement Algorithm on Normalized YCbCr color space (Normalized YCbCr 색 공간에서의 적응적 채도 향상 방법)

  • 옥현욱;최원희;김창용
    • Proceedings of the IEEK Conference
    • /
    • 2003.11a
    • /
    • pp.385-388
    • /
    • 2003
  • In this paper, we propose a new saturation enhancement algorithm which is processed on the new color space, called Normalized YCbCr(NYCbCr). The algorithm consists of two processing unit. One is color space conversion from YCbCr to NYCbCr, and the other is using adaptive saturation mapping function(ASMF). NYCbCr color space is designed to prevent shortcomings such as luminance and hue shift of YCbCr color space and by saturation enhancement. ASMF is effective to enhance saturation properly for each image and to protect low saturation regions of color images from over-saturation. we verified our method using several color images. Experimental results show that the proposed method enhance the saturation with minimizing Luminance and Hue shift.

  • PDF

Autotuning of A PID Controller Using a Saturation function Having a Memory

  • Oh, Seung-Rohk
    • Journal of IKEEE
    • /
    • v.11 no.4
    • /
    • pp.193-197
    • /
    • 2007
  • We use a saturation function with memory instead of a pure saturation function to generate a limit cycle in order to find one point information of a plant in the frequency domain. The saturation function with memory is useful in the presence of noise and/or a short duration of short duration of external disturbances. We analyze the error caused by the approximation that the saturation function with memory treated as a pure saturation function. We propose a new tuning formula for PID controller which can be applied a saturation function having memory with an arbitrary memory size. We show that the proposed method is more accurate than that of the approximation method via an example.

  • PDF

Saturation Prediction for Crowdsensing Based Smart Parking System

  • Kim, Mihui;Yun, Junhyeok
    • Journal of Information Processing Systems
    • /
    • v.15 no.6
    • /
    • pp.1335-1349
    • /
    • 2019
  • Crowdsensing technologies can improve the efficiency of smart parking system in comparison with present sensor based smart parking system because of low install price and no restriction caused by sensor installation. A lot of sensing data is necessary to predict parking lot saturation in real-time. However in real world, it is hard to reach the required number of sensing data. In this paper, we model a saturation predication combining a time-based prediction model and a sensing data-based prediction model. The time-based model predicts saturation in aspects of parking lot location and time. The sensing data-based model predicts the degree of saturation of the parking lot with high accuracy based on the degree of saturation predicted from the first model, the saturation information in the sensing data, and the number of parking spaces in the sensing data. We perform prediction model learning with real sensing data gathered from a specific parking lot. We also evaluate the performance of the predictive model and show its efficiency and feasibility.

Comparison of oxygen saturation, heart rate of cerebral palsy and normal child between the pre-ambulation and post-ambulation (뇌성마비아동과 정상아동의 보행전후 산소포화도 및 심박수 비교에 관한 연구)

  • Hwang, Joo-Moon;Lee, Wan-Hee
    • Journal of Korean Physical Therapy Science
    • /
    • v.10 no.1
    • /
    • pp.38-46
    • /
    • 2003
  • Since the current tendencies show us the increasing number of cerebral palsy children and the standard longevity, we need to find out more research about the following various problems. Therefore I have tried to figure out the difference of oxygen saturation and heart rate between before ambulation and after. Objects chosen are 17 C.P children on the process of treatment those who were able to walk and 8 normal children in Ah-San hospital, Gang-Nung. They haven't had either any operation or suffered heart disease and I measured their oxygen saturation and heart rate by using pulse-oximeter and are analyzed by SPSS (10.07 version). Results are the followings; 1. There was no difference of oxygen saturation and heart rate between pre-ambulation and post-ambulation of normal and spastic hemiplegia children. 2. There showed the significant statistic difference of oxygen saturation, heart rate between pre-ambulates and post-ambulation of normal and spastic diplegia(p<.05). 3. There was no difference of oxygen saturation, heart rate in C.P between(p>.05), but shows the significant statistic difference in heart rate(p<.05). As I compared the oxygen saturation and heart rate of spastic and normal children on between pre-ambulation and post-ambulation, theres is significant statistic difference on both items (p<.05). However there was no difference of oxygen saturation among hemiplegia, normal and diplegia children while the pulse rate showed the significant difference(p<.05). According to this clinical research, CP children's oxygen saturation and heart rate had no change between pre and post compared to normal children. But there was difference in diplegia. This is why we need to invest time to study these kinds of research about various analysis and comparison of oxygen saturation and heart rate, and furthermore making use of pulse-oxymetry in physical therapy room for the children involved would be beneficial to calculate in accuracy without any discomfort for the patient as well.

  • PDF

An Algorithm for Detecting CT Saturation (변류기 2차전류의 포화 여부 판단 알고리즘)

  • Gang, Yong-Cheol;Ok, Seung-Hun;Gang, Sang-Hui
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.50 no.6
    • /
    • pp.275-278
    • /
    • 2001
  • This paper presents an algorithm for detecting current transformer (CT) saturation. At the instants of beginning (or end) of saturation, as a magnetizing inductance of the core is changed significantly, the shapes of the secondary current are also changed significantly though secondary currents are continuous the instants. At the instants, the second-order of third-order difference of the secondary current has big values. Thus, the third difference of the current is used to detect the beginning/end of CT saturation in this paper. If the magnitude of third-order difference of the secondary current is larger than a threshold value, the CT begins of ends saturation at the instants. The proposed detection method is unaffected by the amount of residual flux. The results of various tests with residual flux from -80% to +80% indicate satisfactory performance of the method.

  • PDF

Anti-Windup Controller Design for the Ship with the Rudder Saturation (Rudder 엑츄에이터 포화특성을 고려한 Anti-Windup 제어계의 설계)

  • 김영복;최명수
    • Journal of Ocean Engineering and Technology
    • /
    • v.16 no.4
    • /
    • pp.61-69
    • /
    • 2002
  • In the actual control systems, there exist many kinds of restrictions or nonlinearities. However, due to the nonlinearities in actuators and sensors, the designed controller may not be applicable in some practical situations. One such nonlinearity is amplitude saturation in actuators. Although sometimes it may be ignored, in other cases failure to consider actuator saturation may severely degrade closed-loop system performance and even lead to instability. On the other hand, limiting the controller gain to avoid saturation sacrifices control effort and may lead to loss of performance. Consequently, in some cases, the actuator saturation must be explicitly taken into account to ensure desired performance. However, in this paper, an anti-windup control system design method is introduced to suppress the windup due to the amplitude saturation of the actuator. The proposed control system has very simple design process and guarantees the good control performance. The validity of the proposed control system will be shown by comparing with the results of a reported paper.

Extrapolating B-H Curve Data using Common Electrical Steel Characteristics for High Magnetic Saturation Applications

  • Chai, Seung-Hee;Kim, Ji-Hyun;Kim, Sung-Il;Hong, Jung-Pyo
    • Journal of Magnetics
    • /
    • v.20 no.3
    • /
    • pp.258-264
    • /
    • 2015
  • In this paper, an adequate B-H curve extrapolation method is proposed and its reliability is verified through experiments. A method is developed to estimate the magnetic saturation induction from the density of the lamination core and electrical resistivity. The magnetic saturation induction of electrical steels measured using a vibration sample magnetometer are compared with the analytical results to validate the accuracy of the proposed estimation method. It is found that the predicted error in the magnetic saturation induction of the electrical steels are approximately 1.2% when the proposed method is used. The performance of interior permanent magnet synchronous motors that applies the proposed method are evaluated via 2D nonlinear finite element analysis and through experiments. Based on the obtained results, the extrapolated B-H curves from the estimated saturation induction can be used for various analyses in saturation region.

Active Vibration Control of Structure Using LMI Optimization Design of Robust Saturation Controller (강인 포화 제어기의 LMI 최적 설계를 이용한 구조물의 능동 진동 제어)

  • Park, Young-Jin;Moon, Seok-Jun;Lim, Chae-Wook
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.3 s.108
    • /
    • pp.298-306
    • /
    • 2006
  • In our previous paper, we developed a robust saturation controller for the linear time-invariant (LTI) system involving both actuator's saturation and structured real parameter uncertainties. This controller can only guarantee the closed-loop robust stability of the system in the presence of actuator's saturation. But we cannot analytically make any comment on control performance of this controller. In this paper, we suggest a method to use linear matrix inequality (LMI) optimization problem which can analytically explain control performance of this robust saturation controller only in nominal system. The availability of design method using LMI optimization problem for this robust saturation controller is verified through a numerical example for the building with an active mass damper (AMD) system.