• Title/Summary/Keyword: Sang-So

Search Result 9,802, Processing Time 0.052 seconds

Analysis of the Ecological Environment for the Landscape Management of the Heritage Site: -A Case of Dongguneung, Kyunggi Province- (전통 사적공간의 경관관리를 위한 생태환경 분석 -경기도 구리시 동구릉을 중심으로-)

  • Lee, Sun;Jin, Sang-Chul
    • Korean Journal of Environmental Biology
    • /
    • v.20 no.4
    • /
    • pp.366-377
    • /
    • 2002
  • This study investigated the ecological environment of Dongguneung, which royal tombs of the Joseon Dynasty aye in. The aim of this study is to do an effective preservation, management and restoration of the royal tomb and garden of the Joseon Dynasty distributed in Seoul and Kyunggi Province through using the data of Dongguneung. In general, Dongguneung contains the predominant Oak class such as Quercus serrata-Quercus mongolica community, while a flatland surrounding its control office, which is often flooded with the rainy season in summer, is mainly Alnus japonica community, Pinus densiflora community ranges around the royal tomb. The subcommunity of Quercus serrata -Quereus mongolica community is distributed into Robinia pseudo-acacia, Pinus rigida, Pinus koraiensis, Carpinus laxiflora and typical subcommunity and so on. In particular, Robinia pseudo -acacia, Pinus rigida and Pinus koraiensis subcommunity, and Alnus japonica community were forested. The soil class of Dongguneung was mainly a sandy loam and its pH was an average of 4.67 (from 4.36 to 5.68). The content of heavy metals including Cu, Pb and Zn etc. in the soil was about twice as much as the natural content in the forest soil. The content of organism and total nitrogen in the topsoil layer was the average of 4.87% and 0.21% respectively, slightly higher than those (organism; 4.55%, total nitrogen; 0.20%) of the forest soil generated from granite bedrock. Cation exchange capacity as the indicator of soil fertility was 15.0 cmol $kg^{-1}$, higher than that in the granite forest soil. However among base exchangeable cations, contents of $Ca^{2+}$ (2.07 cmol $kg^{-1}$), $Mg^{2+}$ (0.40 cmol $kg^{-1}$) and K+ (0.25 cmol $kg^{-1}$) were slightly lower than that. The above results could reflect the need of soil fertilization and liming for the improvement of nutritional status and buffer process.

Conceptual framework for Emotions in Usability of Products (제품 사용성과 감성에 관한 개념적 연구)

  • Lee Kun-Pyo;Jeong Sang-Hoon
    • Science of Emotion and Sensibility
    • /
    • v.8 no.1
    • /
    • pp.17-28
    • /
    • 2005
  • With the advent of computer technology, the fundamental nature of products has shaped from physical forms towards product interactivity, The focus is now on usability of the product with ease and efficiency rather than conversing with just the looks of the product. However, most definitions of usability and contemporary usability-related researches, have focused on the performance-oriented functional aspects of usability (i.e., how well users perform tasks using a product). Today, user expectations are higher; products that bring not only functional benefits but also emotional satisfaction. So far, there have been many studies on human emotions and the emotional side of products in the field of emotional engineering. Contemporary emotion-related researches have focused mainly on the relationship between product aesthetics and the emotional responses elicited by the products, but little is known about emotions elicited from using the products. The main objective of our research is analyzing user's emotional changes while using a product, to reveal the influence of usability on human emotions. In this research, we suggested conceptual framework for the study on the relationship between usability of products, and human emotions with emphasis on mobile phones. We also extracted emotional words for measuring user's emotions expressed not from looking at the product's appearance, but from using the product. First, we assembled a set of emotions that is sufficiently extensive to represent a general overview of the full repertoire of Korean emotions from the literature study. Secondly, we found emotional words in the after note by the users on the websites. Finally, verbal protocols in which the user says out loud what he/she ks feeling while he/she ks carrying out a task were collected. And then, the appropriateness of extracted emotional words was verified by the members of the consumer panel of a company through web survey. It is expected that emotional words extracted in this research will be used to measure user's emotional changes while using a product. Based on the conceptual framework suggested in this research, basic guidelines on interface design methods that reflect user's emotions will be illustrated.

  • PDF

Effects of Dietary Herbaceous Peat on In Vitro Fermentation and Milk Production in Dairy Cows (허브부식토의 사료내 첨가에 따른 In Vitro 발효특성과 젖소의 유생산성에 미치는 영향)

  • Kim, Hyeon-Shup;Park, Joong-Kook;Kim, Hong-Yun;Kim, Sang-Bum;Yang, Seung-Hak;Kim, Chang-Hyun;Ahn, Jong-Ho
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.31 no.2
    • /
    • pp.177-190
    • /
    • 2011
  • This study was conducted to determine effects of dietary herbaceous peat on in vitro fermentation and milk production in dairy cows. Ruminal pH, gas production, VFA (volatile fatty acid), Ammonia-N, and rumen degradability were examined by the addition of three times over 0, 1, and 5% herbaceous peat with substrate of timothy hay, and the change of rumen fermentation characteristics were evaluated. In 0, 3, 12 and 24 hours cultivation, all treatments did not show a significant difference but the control at 6 hours appeared significantly lower pH compared to 1 and 5% treatments (p<0.05). The gas production of the treatments significantly increased until 12 hours of cultivation compared to control (p<0.05), the rumen ammonia concentration showed a tendency to increase until 24 hours in all treatment groups, and there was no significant difference between treatments. About the rumen degradability, 5% treatment showed higher rumen degradability in all hours than control and 1% treatment (p<0.05). Meanwhile, for in vivo trial, 16 heads of Holstein lactation dairy cows were selected for experiment for four weeks in order to research the change of milk yield, milk compositions and change of somatic cell counts of lactation dairy cows by herbaceous peat feeding. The milk yield of vitamin C and herbaceous peat treatments (T3) was 25.0 kg but the control was 23.2 kg, herbaceous peat treatment (T1) was 23.1 kg, and vitamin C treatment (T2) was 23.4 kg, so there was linear increase effect of milk yield by T3. The partial significance of the milk (fat, milk protein, lactose, MUN and SNF) and change of somatic cell count before and after experiment by the control and treatments about change of milk and somatic cell counts (p<0.05) were recognized. About change of milk in the first half (1~2 weeks) and latter half (3~4 weeks) during four weeks of experiments period, the herbaceous peat supplement treatments showed a tendency of significant decrease of quality of milk protein and SNF. The control and treatments did not show significant change of blood nutrients (total protein, cholesterol, NEFA, BUN), liver function component (AST, GGT) and minerals (Ca, P, Mg) before and after experiment. In summary, it is judged that herbaceous peat feeding for lactation dairy cows would be recommendable based on the results of milk, somatic cell count physiologically.

A Study of Reportable Range Setting through Concentrated Control Sample (약물검사에서 관리시료의 농축을 이용한 보고 가능 범위의 설정에 대한 연구)

  • Chang, Sang Wu;Kim, Nam Yong;Choi, Ho Sung;Park, Yong Won;Yun, Keun Young
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.36 no.1
    • /
    • pp.13-18
    • /
    • 2004
  • This study was designed to establish working range for reoportable range in own laboratory in order to cover the upper and lower limits of the range in test method. We experimented ten times during 10 days for setting of reportable range with between run for method evaluation. It is generally assumed that the analytical method produces a linear response and that the test results between those upper and lower limits are then reportable. CLIA recommends that laboratories verify the reportable range of all moderate and high complexity tests. The Clinical Laboratory Improvement Amendments(CLIA) and Laboratory Accreditation Program of the Korean Society for Laboratory Medicine states reportable range is only required for "modified" moderately complex tests. Linearity requirements have been eliminated from the CLIA regulations and from others accreditation agencies, many inspectors continue to feel that linearity studies are a part of good lab practice and should be encouraged. It is important to assess the useful reportable range of a laboratory method, i.e., the lowest and highest test results that are reliable and can be reported. Manufacturers make claims for the reportable range of their methods by stating the upper and lower limits of the range. Instrument manufacturers state an operating range and a reportable range. The commercial linearity material can be used to verify this range, if it adequately covers the stated linear interval. CLIA requirements for quality control, must demonstrate that, prior to reporting patient test results, it can obtain the performance specifications for accuracy, precision, and reportable range of patient test results, comparable to those established by the manufacturer. If applicable, the laboratory must also verify the reportable range of patient test results. The reportable range of patient test results is the range of test result values over which the laboratory can establish or verify the accuracy of the instrument, kit or test system measurement response. We need to define the usable reportable range of the method so that the experiments can be properly planned and valid data can be collected. The reportable range is usually defined as the range where the analytical response of the method is linear with respect to the concentration of the analyte being measured. In conclusion, experimental results on reportable range using concentrated control sample and zero calibrators covering from highest to lowest range were salicylate $8.8{\mu}g/dL$, phenytoin $0.67{\mu}g/dL$, phenobarbital $1.53{\mu}g/dL$, primidone $0.16{\mu}g/dL$, theophylline $0.2{\mu}g/dL$, vancomycine $1.3{\mu}g/dL$, valproic acid $3.2{\mu}g/dL$, digitoxin 0.17ng/dL, carbamazepine $0.36{\mu}g/dL$ and acetaminophen $0.7{\mu}g/dL$ at minimum level and salicylate $969.9{\mu}g/dL$, phenytoin $38.1{\mu}g/dL$, phenobarbital $60.4{\mu}g/dL$, primidone $24.57{\mu}g/dL$, theophylline $39.2{\mu}g/dL$, vancomycine $83.65{\mu}g/dL$, valproic acid $147.96{\mu}g/dL$, digitoxin 5.04ng/dL, carbamazepine $19.76{\mu}g/dL$, acetaminophen $300.92{\mu}g/dL$ at maximum level.

  • PDF

Assessment of Estimated Daily Intake of Sorbic Acid and Benzoic Acid in the Korean Population (한국인의 소르빈산 및 안식향산 섭취수준 평가)

  • Lee, Kyung-Hyun;Kim, Ae-Young;Choi, Sung-Hee;Lim, Ho-Soo;Choi, Jae-Chun;Kim, Mi-Hye;Kim, So-Hee;Ha, Sang-Do
    • Journal of Food Hygiene and Safety
    • /
    • v.28 no.4
    • /
    • pp.293-298
    • /
    • 2013
  • In this study, sorbic acids and benzoic acids frequently used in foods retailed in Korea were monitored and their estimated daily intakes were assessed for a purpose to ensure food additives safety management. The estimated daily intakes were calculated by categorizing the assessment items into the national average, by gender, by age and the high intake ($95^{th}$) groups based on concentrations of preservatives in foods as well as national health and nutrition survey data. The calculations were then compared with the ADI of the JECFA and the possibility of risk to be imposed on the people was examined. The results indicated that the estimated daily average intakes of preservatives were $221.60{\mu}g/kg{\cdot}bw/day$ of sorbic acids and $27.30{\mu}g/kg{\cdot}bw/day$ of benzoic acids. Compared to the ADI, the intake levels were 0.89 and 0.55% respectively, which were in a safe range. The estimated daily intakes of sorbic acids and benzoic acids in the high intake group ($95^{th}$) were $1140.27{\mu}g/kg{\cdot}bw/day$ and $194.95{\mu}g/kg{\cdot}bw/day$, which were 4.56% and 3.90% of the ADI (%) respectively, indicating that the intake levels of sorbic acids and benzoic acids in the high intake group were within a safe range. As for gender difference, the amount of benzoic acids intake was slightly larger in men than in women. However, gender differences were not observed in terms of the intake of sorbic acids. In terms of the levels of intake by age, the rates were found to be in the range of 0.52-2.10% for sorbic acids and 0.15-1.23% for benzoic acids. Therefore, the levels of sorbic acids and benzoic acids intakes were found not to exceed the ADI in all groups, and thus were within the safe ranges.

Trends in Rapid Detection Methods for Marine Organism-derived Toxins (해양 생물 유래 독소의 나노 기술 기반 신속 진단법 개발 동향)

  • Park, Chan Yeong;Kweon, So Yeon;Moon, Sunhee;Kim, Min Woo;Ha, Sang-Do;Park, Jong Pil;Park, Tae Jung
    • Journal of Food Hygiene and Safety
    • /
    • v.35 no.4
    • /
    • pp.291-303
    • /
    • 2020
  • Marine organism-derived toxins have negative effects not only on human health but also in aquaculture, fisheries, and marine ecosystems. However, traditional analytical methods are insufficient in preventing this threat. In this paper, we reviewed new rapid methods of toxin detection, which have been improved by adopting diverse types of nanomaterials and technologies. Moreover, we herein describe the main strategies for toxin detection and their related sensing performance. Notably, to popularize and commercialize these newly developed technologies, simplifying the process of pre-treating real samples real samples is very important. As part of these efforts, numerous studies have reported pretreatment methods based on the antibody-immobilized magnetic nanoparticles, and some cases have applied nanoparticles to enhance the sensing performance by utilizing the intrinsic catalytic activity. Furthermore, some reports have introduced fluorescent nanoparticles, such as quantum dots, to represent the lower detection limits of conventional enzyme-based colorimetric methods and lateral flow assays. Some studies using electrochemical measurements based on aptamer-nanoparticle complexes have also been announced. In addition, as the response to new toxins generated by changes in the marine environment is still lacking, further research on diagnostic and detection is also greatly needed for these kinds of marine toxins and their derivatives.

An experimental study of the strength and internal structure of solder joint of fixed partial denture (가공의치(架工義齒) 납착부(蠟着部)의 강도(强度)와 내부구조(內部構造)에 관(關)한 실험적(實驗的) 연구(硏究))

  • Park, Sang-Nam;Kay, Kee-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.23 no.1
    • /
    • pp.39-59
    • /
    • 1985
  • The purpose of this study was to investigate how gap distances of 0.13mm, 0.15mm, 0.20mm, and 0.30mm affects solder joint strength from gold alloys and nickel-chromium base alloys and to examine the composition of solder gold, the solder joint of gold alloys and nickel-chromium base alloys. The tensile test specimens were prepared in the split stainless steel mold with a half dumbbell shape 2.5mm in diameter and l2mm in length. 6 pairs of specimens of each gap distance group of gold alloys and nickel-chromium base alloys were made and 48 pairs of all specimens were soldered with solder gold of 666 fineness. All soldered specimens were machined to a uniform diameter and then a tensile load was applied at a cross-head speed of 0.10mm/min using Instron Universal Testing Machine, Model 1115. The fractured specimens at solder gold of solder joint fracture with each gap distance of 0.13mm, 0.15mm, 0.20mm, and 0.30mm were examined under the Scanning Electron Microscope, JSM-35c and the composition of solder gold, the solder joint of gold alloys and nickel-chromium base alloys was analyzed by Electron Probe Micro Analyzer. The results of this study were obtained as follows: 1. In case of soldering of gold alloys, the tensile strength between gold alloys showed $37.33{\pm}2.52kg/mm^2$ at 0.13, $39.14{\pm}3.35kg/mm^2$ at 0.15mm, $43.76{\pm}2.97kg/mm^2$ at 0.20mm, and $49.18{\pm}4.60kg/mm^2$ at 0.30mm. There was statistically significant difference at each gap distance, and so the greater increase of gap distance showed the greater tensile strength. 2. In case of soldering of nickel-chromium base alloys, the tensile strength between nickel-chromium base alloys showed $34.84{\pm}4.26kg/mm^2$ at 0.13mm, $37.25{\pm}2.49kg/mm^2$ at 0.15mm, $42.91{\pm}4.32kg/mm^2$ at 0.20mm, and $46.93{\pm}4.21kg/mm^2$ at 0.30mm. There was not statistically significant difference only between 0.13mm and 0.15mm and bet ween 0.20 mm and 0.30mm, but generally the greater increase of gap distance showed the greater tensile strength. 3. The greater increase of gap distance shoed less porosities in solder gold at solder joint fracture. 4. In solder gold Au, Cu, Ag, Zn, and Sn were composed and Au and Cu were mostly distributed uniformly. 5. In solder joints of solder gold and gold alloys Au, Cu, Ag, Zn, and Sn were composed in solder gold and Au, Cu, Ag, Pt, and Pd were composed in gold alloys. Au and Cu of solder gold and gold alloys were mostly distributed uniformly and the diffusion of other elements except Pt and Pd around the solder joint was not almost found. In solder joints of solder gold and nickel-chromium base alloys Au, Cu, Ag, Zn, and Sn were composed in solder gold and Ni, Cr, and Al were composed in nickel-chromium base alloys. Au and Cu of solder gold and Ni and Cr of nickel-chromium base alloys were mostly distributed uniformly and the diffusion of other elements except Cr around the solder joint was not almost found.

  • PDF

Comparison on accuracy of porcelain color reproducibility using two colorimeters (2종의 측색기에 의한 도재 색조 재현의 정확성 비교)

  • Lee, Tai-Il;Ahn, Jin-Soo;Kim, Young-Soo;Shin, Sang-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.3
    • /
    • pp.348-355
    • /
    • 2009
  • Statement of problem: Although the use of colorimeter to improve the accuracy of tooth color measurement has increased, it is real situation that there is almost no comparative study about the accuracy among various colorimeters. Purpose: The purpose of this study is to compare the accuracy of porcelain color reproducibility using ShadeEye-Ncc dental chroma meter (Shofu Inc., Kyoto, Japan) and Shadepilot$^{TM}$ system (Degudent Inc., Hanau, Germany). Material and methods: Color of 2M2 and 3M2 shade tap of Vitapan 3D Master shade guide were measured using the above two colorimeters. Porcelain specimens were fabricated through this data. The porcelain systems used were Vintage Halo Porcelain system with ShadeEye-Ncc dental chroma meter, and VitaOmega900 Porcelain system with Shadepilot$^{TM}$ system. Colors of shade tap models and porcelain specimen were measured with spectrophotometer, and calculated delta E based on the results. Results: The following results were obtained. 1. Shadepilot$^{TM}$ system showed more suitable porcelain color reproducibility compared to ShadeEye-Ncc dental chroma meter (P <.05). 2. The result showed the difference of porcelain color reproducibility according to shade of Shade tap which is model. More suitable porcelain color reproducibility was shown at 3M2 shade tap than at 2M2 shade tap (P <.05). 3. The average of ${\Delta}E*$ of porcelain specimens which was made by the two colorimeters was 4.44-6.14, so the difference of shade was shown through the naked eye. Conclusion: Shadepilot$^{TM}$ system showed more suitable porcelain color reproducibility. When using ShadeEye-Ncc dental chromameter, it will be necessary to improve accuracy through coloring various parts of the whole tooth.

Shear bond strength of Universal bonding systems to Ni-Cr alloy (니켈-크롬 합금에 대한 다용도 접착 시스템의 전단결합강도)

  • Song, So-Yeon;Son, Byung-Wha;Kim, Jong-Yeob;Shin, Sang-Wan;Lee, Jeong-Yol
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.4
    • /
    • pp.295-300
    • /
    • 2015
  • Purpose: The aim of this study was to evaluate the shear bond strength between Ni-Cr alloy and composite resin using universal adhesive systems coMPared to conventional method using metal primers. Materials and methods: For this study, a total of 120 cast commercial Ni-Cr alloy (Vera Bond 2V) disks were embedded in acrylic resin, and their surfaces were smoothed with silicon carbide papers and airborne-particle abrasion. Specimens of each metal were divided into 6 groups based on the combination of metal primers (Metal primer II, Alloy primer, Metal & Zirconia primer, MKZ primer) and universal adhesive systems (Single Bond Universal, All Bond Universal). All specimens were stored in distilled water at $37^{\circ}C$ for 24 hours. Shear bond strength testing was performed with a universal testing machine at a cross head speed of 1 m/min. Data (MPa) were analyzed using one-way ANOVA and the post hoc Tukey's multiple comparison test (${\alpha}$=.05). Results: There were significant differences between Single Bond Universal, All Bond Universal, Metal Primer II and Alloy Primer, MKZ Primer, Metal & Zirconia Primer (P<.001). Conclusion: Universal Adhesive system groups indicated high shear bond strength value bonded to Ni-Cr alloy than that of conventional system groups using primers except Metal Primer II. Within the limitations of this study, improvement of universal adhesive systems which can be applied to all types of restorations is recommended especially non-precious metal alloy. More research is needed to evaluate the effect of silane inclusion or exclusion in universal adhesive systems.

SEDATION EVALUATION USING BIS INDEX ASSESSMENT WITH AND WITHOUT THE ADDED SUBMUCOSAL MIDAZOLAM (점막하 Midazolam의 병용투여 시 BIS 분석을 이용한 진정 평가)

  • Lee, Young-Eun;Park, Mi-Kyung;Kim, So-Young;Kim, Yun-Hee;Jung, Sang-Hyuk;Baek, Kwang-Woo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.34 no.1
    • /
    • pp.91-98
    • /
    • 2007
  • The aim of this study was to examine the difference of the depth of sedation using the Bispectral index assessment with and without the added submucosal Midazolam to oral Chloral hydrate and Hydroxyzine for pediatric patients. Twenty seven sedation cases were performed in this study Selection criteria included good health(ASA I), 2 to 6 years of age, the need for sedation to receive dental treatment including anesthesia, and restorative procedure over at least two teeth. Patients were randomly classified into one group taking oral Chloral hydrate(60 mg/kg) and Hydroxyzine(1 mg/kg) and the other group recieving Chloral hydrate(60 mg/kg), Hydroxyzine(1 mg/kg) and submucosal Midazolam(0.1 mg/kg). Nitrous Oxide(50%) was used for both group during sedation. Patients were monitored using a pulse oximeter and a Bispectral monitor. A behavior scale was rated as quiet(Q), crying(C), movement(M), or struggling(S) every 2 minutes watching a recorded videotape. Analysis showed a significant difference in mean Bispectral index and SD during sedation across two groups(P<0.001). The group of patients injected with submucosal Midazolam in addition to oral Chloral hydrate and Hydroxyzine showed a lower mean Bispectral index and a narrower SD. PR and SpO2 for both groups remained within the normal values. Submucosal Midazolam improved the sedation quality by deepening sedation depth without compromising safety and enabled the sedation pattern to be kept more stable.

  • PDF