• 제목/요약/키워드: Sang-Hook Lee

검색결과 34건 처리시간 0.021초

IdBean: a Java GUI application for conversion of biological identifiers

  • Lee, Sang-Hyuk;Kim, Bum-Jin;Kim, Hyeon-Jin;Lee, Hook-Eun;Yu, Ung-Sik
    • BMB Reports
    • /
    • 제44권2호
    • /
    • pp.107-112
    • /
    • 2011
  • We have developed a biologist-friendly, stand-alone Java GUI application, IdBean, for ID conversion. Our tool integrated most of the widely used ID conversion services that provide programmatic access. It is the first GUI ID conversion application that supports the direct merging as well as comparison of conversion results from multiple ID conversion services without manual effort. This tool will greatly help biologists who handle multiple ID types for the analyses of gene or gene product lists. By referring to multiple conversion services, the number of failed IDs can be reduced. By accessing ID conversion service online, it will potentially provide the most up-to-date conversion results. The application was developed in modular form; however, it can be re-packaged into plug-in form. For the development of a bioinformatics analysis tool, the module can be used as a built-in ID conversion component. It is available at http://neon.gachon.ac.kr/IdBean/.

Wind Tunnel Study on Flow Characteristics around KRISO 300K VLCC Double-body Model (KRISO 300K VLCC 이중모형선의 유동특성에 대한 풍동실험 연구)

  • Hak-Rok Kim;Sang-Joon Lee
    • Journal of the Society of Naval Architects of Korea
    • /
    • 제36권3호
    • /
    • pp.15-21
    • /
    • 1999
  • The flow characteristics around KRISO 300K VLCC double-body model have been experimentally investigated in a closed-type subsonic wind tunnel. The local mean velocity and turbulence statistics including turbulent intensity. Reynolds shear stress and turbulent kinetic energy were measured using a x-type hot-wire probe. The measurements were carried out at several transverse stations of the stern and near wake regions. The surface flow was visualized using on oil-film technique to see the flow pattern qualitatively. The flow in the stern and near wake region revealed complicated three-dimensional flow characteristics. The VLCC model shows a hook-shaped wake structure behind the propeller boss in the main longitudinal vortex region. The thin boundary layer at midship was increased gradually in thickness over the stern and evolved into a full three-dimensional turbulent wake.

  • PDF

Spreading Pattern of Epidurally-Administered Contrast Media in Rabbits (토끼에서 경막외강으로 투여한 조영제의 분포양상)

  • Lee, Sang-Chul
    • The Korean Journal of Pain
    • /
    • 제10권2호
    • /
    • pp.231-234
    • /
    • 1997
  • Background: The aim of this study was to examine the precise spreading pattern of contrast media in small increments in rabbits. Following pentobarbital anesthesia, the epidural puncture was done surgically with a blunt hook. Methods: The tip of epidural catheter was located at the mid-portion of T7 and T12, in the T7 group (n=7) and T12 group (n=8), respectively. Injection of the contrast media was started at 0.1 mL/kg and increased by 0.1 mL/kg up to a maximum of 0.6, mL/kg, under fluoroscopy. Results: In both groups, the extent of spread increased continuously as a Starling resistor with increasing injected volume(T7 group: $y=4.0+41.8x-28.1x^2$, T12 group: $y=0.2+57.7x-43.5x^2$) the total spread of contrast media was similar. The contrast media spread equally, both rostral and caudal, from catheter tip in T7 group; media spread approximately twice as far rostral as compared to caudal in T12 group (P<0.05). Conclusions: In rabbits, the position of epidural catheter tip should be positioned 2~3 segments below the aimed segment in lower thoracic or lumbar region, whereas in mid-thoracic region it should be positioned close to the level of aimed segment. Rabbits have relatively small epidural space therefore, the volume of injectant should be carefully determined with the suggested equations of this study.

  • PDF

Arthroscopic Repair of Acute Posterior Cruciate Ligament Rupture with Autogenous Hamstring Tendon Graft Augmentation - Technical Note (급성 후방 십자 인대 파열의 관절경하 봉합술 및 자가 슬괵 이식건 보강술 - 수술 술기 -)

  • Ahn, Jin-Hwan;Lee, Sang-Hak;Sung, Kee-Lyong
    • Journal of the Korean Arthroscopy Society
    • /
    • 제9권1호
    • /
    • pp.70-76
    • /
    • 2005
  • Purpose: We describe a new technique of arthroscopic repair with using autogenous hamstring tendon graft augmentation for the acute posterior cruciate ligament rupture. Operative technique: A routine arthroscopic examination of the knee joint is initially performed, then the posterior trans-septal portal is prepared with the using the posteromedial and posterolateral portals. The torn tibial stump that is retracted to the posterior compartment is repaired by a suture hook that is introduced through the anteromedial portal; visualization during this procedure is done with the arthroscope via the posteromedial portal. Using the retrieved suture, both suture ends are brought out to the anteromedial portal. The torn tibial stump is pulled to the intercondylar notch and then repaired with stitches at the anterior compartment. After the tibial and femoral tunnels are prepared without damaging the remnant PCL bundle, the combined torn PCL fibers and the autogenous single-bundle semitendinosus and gracilis tendon grafts are passed through the femoral tunnel and fixed together Conclusion: Arthroscopic repair of the torn tibial stump and autogenous hamstring tendon graft augmentation after preparing the tibial and femoral tunnels by using the trans-septal portal, without damaging the remnant PCL bundle, seems to be a very effective method for the treatment for acute PCL injuries, and especially for tears at the femoral attachment.

  • PDF

Effective Reduction of the Frontal Process of the Maxillary Fracture Segment Using Intermaxillary Fixation Screw (악간고정용 스크류를 이용한 위턱뼈 이마돌기 골절편의 효과적인 정복)

  • Moon, Suk-Ho;Lee, Woo-Sung;Lee, Jung-Ho;Rhie, Jong-Won;Ahn, Sang-Tae;Oh, Deuk-Young
    • Archives of Plastic Surgery
    • /
    • 제38권4호
    • /
    • pp.555-558
    • /
    • 2011
  • Purpose: It is relatively unusual that infraorbital rim fracture is accompanied by nasal bone fracture. In order to correct effectively, subciliary approach and intranasal manipulation are applied simultaneously. But if reduction is not successful, intranasal manipulation may become aggressive and this often causes complications. We introduce a method using intermaxillary fixation screws for decreasing such complications and effective reduction of fracture. Methods: Total seven patients with fracture of frontal process of maxilla were treated with this method. The fracture site was exposed through the subciliary approach, and one or two screws were inserted into the displaced fracture fragment. During the traction of the screws using the wire, the fracture fragment was pushed upward from the intranasal side using an elevator supplementarily and fixed with a plate and the screws. Results: In all patients, the fracture fragment was reduced successfully and no complication occurred during one year's postoperative follow-up. Conclusion: When reduction cannot be attained through a bone hook or an elevator alone, reduction of fracture fragment can be done easily using intermaxillary fixation screws. This method is less likely to cause a mucosal injury because intranasal manipulation is not aggressive. Furthermore, as the screw can be inserted and removed easily, this method is considered effective not only for fracture of frontal process of maxilla but also for fractures in other regions.

Outcomes of Single-Incision Thoracoscopic Surgery Using the Spinal Needle Anchoring Technique for Primary Spontaneous Pneumothorax

  • Lee, Seung Hyong;Lee, Sun-Geun;Cho, Sang-Ho;Song, Jae Won;Kim, Dae Hyun
    • Journal of Chest Surgery
    • /
    • 제55권1호
    • /
    • pp.44-48
    • /
    • 2022
  • Background: Although classical multi-port video-assisted thoracic surgery has been widely performed, single-incision thoracoscopic surgery (SITS) is a popular surgical technique for the treatment of primary spontaneous pneumothorax (PSP). However, the inconvenient alignment of instruments and the limited field of view occasionally make surgeons convert from SITS to multi-port surgery or extend the incision. This study aimed to present an easy and safe SITS technique for PSP using a spinal needle. Methods: In total, 139 patients underwent SITS between May 2011 and December 2017. We used a spinal needle to hook the bulla or bleb, and wedge resection was performed through a small incision. Patients' medical records were reviewed retrospectively, and a telephone survey was conducted to investigate the recurrence rate. Results: The mean age of the 139 patients was 23.62±9.60 years. The mean operative time was 36.69±14.64 minutes, and multi-port conversion was not performed. The mean postoperative hospital stay was 3.00±0.78 days, and the mean indwelling chest tube duration was 1.97±0.77 days. No complications were observed. In the mean follow-up period of 86.75±23.20 months, recurrence of pneumothorax was found in 3 patients. Conclusion: We suggest that SITS for PSP with the aid of a spinal needle to replace a grasper is a safe and easy technique that only requires a small incision.

Molecular Cloning and Characterization of Bovine HMGA1 Gene

  • Yu, S.L.;Chung, H.J.;Sang, B.C.;Bhuiyan, M.S.A.;Yoon, D.;Kim, K.S.;Jeon, J.T.;Lee, J.H.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제20권11호
    • /
    • pp.1662-1669
    • /
    • 2007
  • The high mobility group AT-hook1 (HMGA1) proteins are known to be related to the regulation of gene transcription, replication and promotion of metastatic progression in cancer cells. The loss of expression by disrupting the HMGA1 gene affects insulin signaling and causes diabetes in the mouse. Previously identified single nucleotide polymorphism (SNP) of HMGA1 was significantly associated with fat deposition traits in the pig. In this study, we identified 3,935 bp nucleotide sequences from exon 5 to exon 8 of the bovine HMGA1 gene and its mRNA expression was observed by quantitative real-time PCR. Six single nucleotide polymorphisms in the bovine HMGA1 gene were detected and the allele frequencies of these SNPs were investigated using the PCR-RFLP method in nine cattle breeds including Limousin, Simmental, Brown Swiss, Hereford, Angus, Charolais, Hanwoo, Brahman and Red Chittagong cattle. The map location showed that the bovine HMGA1 gene was also closely located with a previously identified meat quality QTL region indicating this gene is the most likely positional candidate for meat quality traits in cattle.

Finite element analysis of maxillary incisor displacement during en-masse retraction according to orthodontic mini-implant position

  • Song, Jae-Won;Lim, Joong-Ki;Lee, Kee-Joon;Sung, Sang-Jin;Chun, Youn-Sic;Mo, Sung-Seo
    • The korean journal of orthodontics
    • /
    • 제46권4호
    • /
    • pp.242-252
    • /
    • 2016
  • Objective: Orthodontic mini-implants (OMI) generate various horizontal and vertical force vectors and moments according to their insertion positions. This study aimed to help select ideal biomechanics during maxillary incisor retraction by varying the length in the anterior retraction hook (ARH) and OMI position. Methods: Two extraction models were constructed to analyze the three-dimentional finite element: a first premolar extraction model (Model 1, M1) and a residual 1-mm space post-extraction model (Model 2, M2). The OMI position was set at a height of 8 mm from the arch wire between the second maxillary premolar and the first molar (low OMI traction) or at a 12-mm height in the mesial second maxillary premolar (high OMI traction). Retraction force vectors of 200 g from the ARH (-1, +1, +3, and +6 mm) at low or high OMI traction were resolved into X-, Y-, and Z-axis components. Results: In M1 (low and high OMI traction) and M2 (low OMI traction), the maxillary incisor tip was extruded, but the apex was intruded, and the occlusal plane was rotated clockwise. Significant intrusion and counter-clockwise rotation in the occlusal plane were observed under high OMI traction and -1 mm ARH in M2. Conclusions: This study observed orthodontic tooth movement according to the OMI position and ARH height, and M2 under high OMI traction with short ARH showed retraction with maxillary incisor intrusion.

Effect of Fluorescent Light Treatment during Imbibition and Culture on Growth of Soybean Sprout

  • Kang, Jin-Ho;Park, A-Jung;Jeon, Byung-Sam;Yoon, Soo-Young;Lee, Sang-Woo
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • 제48권4호
    • /
    • pp.292-296
    • /
    • 2003
  • The lateral root formation in soybean sprout culture declines its quality. This study was done to measure the effect of fluorescent light treatment during 24 hour imbibition and 6-day culture on seed germination and growth of soybean sprout. After 6 day culture, the sprouts were sorted as normal (>4cm), abnormal (<4cm) and non-germination by their hypocotyl lengths, and lateral roots, fresh and dry weights were measured. Lateral roots were less formed in the fluorescent light treatment lasted during the whole period of the imbibition than in the treatment for 50 minutes a day during the culture. The fluorescent light treatment during the imbibition mainly affected the germination and growth compared to the treatment done during the culture. Compared to the dark imbibition, the light treatment during the imbibition resulted in more normal sprouts, thicker diameters of hypocotyl and hook, and more fresh weights in cotyledon, hypocotyl, whole sprout, and economic yield. However, these results were reverse in lengths of hypocotyl and root, and fresh and dry weights of roots. It is concluded that the fluorescent lamp mainly irradiating red and blue lights can be used for the sprout production as an alternative light replacing blue and red lights treated during the imbibition because it blocked the lateral root appearance and stimulated growth of the sprout.

A Study on the Dress of the Period of the Three States From the Wall Painting of Afrasiab's Palace in Samarkand (사마르칸트 아프라시압궁전 벽화에 나타난 삼국시대복식연구)

  • Lee, Sang-Eun;Kim, Ae-Ryeon
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • 제8권2호
    • /
    • pp.183-199
    • /
    • 2006
  • This study aims to estimate the nationality of two envoys by examining their dresses and appearances depicted on the wall painting of Afrasiab's Palace in Samarkand with the concentration on the history of the international exchange between three states and the countries in Central Asia. The international exchange between three states and the countries in Central Asia are examined with the concentration on the literature review. And what are related to the dresses during the period of the three states are examined with the concentration on the literature review and the wall painting of Goguryeo tomb. The followings results were identified. The dresses of envoys were comprised of Jowugwan, the soft hat shaped like a peaked hat, the upper garment reaching a hip line with Jikryeong Gyoim and Tongsu, narrow trousers, black belt with a hook, front-pointed shoes and big sword with a round ring. The items of dressing are very similar to those during the Goguryeo period as observed on the wall paintings and excavated articles from the tombs from the Goguryeo period and literature. The next examination is estimated that Goguryeo had the official relationship with the countries in Central Asia before the invasion of Tang in mid-7 century when the wall painting, in our estimation, was produced, and to this end, Goguryeo sent the envoys to those countries. The envoys on the wall painting were estimated to be from Goguryeo as discussed above.

  • PDF