• Title/Summary/Keyword: Sand Chamber

Search Result 105, Processing Time 0.031 seconds

Analysis of Cementation Effect on Small Strain Shear Modulus of Sand (사질토의 미소변형 전단탄성계수에 대한 고결영향 분석)

  • Lee, Moon-Joo;Choo, Hyunwook;Choi, Sung-Kun;Lee, Woojin
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.2C
    • /
    • pp.51-58
    • /
    • 2009
  • In this study, the small strain shear moduli ($G_{max}$) of uncemented and gypsum-cemented sands are evaluated by performing a series of bender element tests on the specimens reconstituted in the calibration chamber. It is observed from the experimental results that $G_{max}$ of crushed-sands is about 35~50% smaller than that of natural sands. The increase in gypsum content is observed to result in an exponential increase of $G_{max}$ value. It is also shown that the relative density has more significant effect on $G_{max}$ of cemented sand, whereas the vertical effective stress has more significant influence on $G_{max}$ of uncemented one. A prediction equation for cemented sand is expressed as a function of gypsum content as well as void ratio and vertical effective stress.

Load Transfer Characteristics of Pile Foundation for Lightweight Pavement in Sand Soil using Laboratory Chamber Test (모형챔버시험을 이용한 사질토 지반의 경량포장체용 기초의 하중전달 특성)

  • Shin, Kwang-Ho;Hwang, Cheol-Bi;Jeon, Sang-Ryeol;Lee, Kwan-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.7
    • /
    • pp.4588-4594
    • /
    • 2014
  • In this study, small scaled (1/30) laboratory chamber tests of the pile foundation for a lightweight concrete pavement system were carried out to evaluate the safety of a pile foundation on sandy soil. The testing ground was simulated in the field and a standard pile-loading test was conducted. The test piles were divided into 3 types, Cases A, B and C, which is the location from the center of the slab by applying a vertical load. The interval between the piles was set to 8 cm. As a result of the pile foundation model test, the pavement settled when the vertical load was increased to 12kg from 1.5kg in sandy soil ground, particularly the maximum settlement of 0.04mm. Judging from the model chamber test, Case A showed compressive deformation, whereas Case B represented the compression and tensile forces with increasing vertical load. Case C showed an increase in tensile strain.

A Study on the Vertical Bearing Capacity of Batter Piles Subjected to Vertical Load (연직하중을 받는 경사말뚝의 연직지지력에 관한 연구)

  • 성인출;이민희;최용규;권오균
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.2
    • /
    • pp.49-55
    • /
    • 2003
  • In this study, based on the relationship of the vertical force - settlement of batter piles obtained by pressure chamber model tests, the vertical bearing capacity of vertical and batter piles according to the increase of pile inclination was analyzed. A model open - ended steel pipe pile with the inclination of 5$^\circ$, 10$^\circ$ and 15$^\circ$ was driven into saturated fine sand with relative density of 50 %, and the static compression load tests were performed under each confining pressure of 35, 70 and 120 kPa in pressure chamber. The vertical bearing capacity of pile obtained from pressure chamber tests increased with the pile inclination. In the case of the inclination of 5$^\circ$, 10$^\circ$, 15$^\circ$, increasing ratios of pile bearing capacity were 111, 121, 127 ~ 140 % of vertical bearing capacity respectively. In the case of the inclination of above 20$^\circ$, the model tests could not be performed because of pile of pile head during compressive loading on the pile head.

Evaluation of Cementation Effect of Jeju Coastal Sediments (제주연안 퇴적층의 고결 평가)

  • Lee, Moon-Joo;Kim, Jae-Jeong;Shim, Jai-Beom;Lim, Chai-Geun;Lee, Woo-Jin
    • Journal of the Korean Geotechnical Society
    • /
    • v.25 no.11
    • /
    • pp.105-115
    • /
    • 2009
  • The Jeju sand was sampled from the beach in Jeju Island and its basic properties were analyzed. The cementation effect of Jeju coastal sediments was evaluated from in-situ tests such as SPT, CPT, and the Suspension-PS test. It was shown from test results that the Jeju sand has high extreme void ratios due to the angularity of grains and the intra-particle voids of hollow particles, similar to typical calcareous sands. From cone penetration test in the calibration chamber, it was found that the cone resistance($q_c$)-relative density($D_R$)-vertical effective stress(${\sigma}_v'$) relation of Jeju sand almost matches that of high compressible quartz sand. However, the $q_C-D_R-{\sigma}_v'$ correlation suggested for uncemented Jeju sand overestimates the relative density of coastal sediments of Jeju Island due to the cementation effect. From the analysis of the relation of cone resistance, N value, and small strain shear modulus measured in-situ, it seems reasonable to assume that the coastal sediment of Jeju Island is a naturally cemented one.

Evaluation of State Parameter of Sands Using Dilatometer Test (딜라토미터 시험을 이용한 사질토의 상태정수 평가)

  • Choi, Sung-Kun;Lee, Moon-Joo;Hong, Sung-Jin;Lee, Woo-Jin
    • Journal of the Korean Geotechnical Society
    • /
    • v.26 no.4
    • /
    • pp.27-36
    • /
    • 2010
  • In this study, a series of flat dilatometer tests are performed for Busan sand reconstituted in a large calibration chamber to evaluate the state parameter ($\Psi$). Experimental result shows that the horizontal amplification factor ($K_D/K_0$) is linearly related with state parameter in semi-logarithmic space, but the $K_D/K_0$ of OC specimen is smaller than that of NC specimen because of the horizontal residual stress by stress history of OC specimen. The relation between the normalized dilatometer modulus ($E_D/\sigma_m'$) and the state parameter is also linearly expressed in semi-logarithmic space, and the effect of stress history is relatively insignificant in this relation. However, the variation in $E_D/\sigma_m'-\Psi$ relation of NC state is slightly higher than that of OC state due to the effect of the stress level, and the correlation curve is descending with increase of confining stress. The comparison of test result with previous results of Ticino and Toyoura sands shows that the $E_D/\sigma_m'-\Psi$ relation of Toyoura sand is located on upper side than that of Busan and Tieino sands due to the effect of the higher compressibility, whereas the $K_D/K_0-\Psi$ relation of each sand is irregularly distributed.

Superhydrophobic Surfaces for condensation by using spray coating method

  • Oh, Seungtae;Seo, Donghyun;Lee, Choongyeop;Nam, Youngsuk
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.157.2-157.2
    • /
    • 2016
  • Water repellent surfaces may enhance the condensation by efficiently removing the condensed droplets. However, such surfaces may lose their original performance as they are exposed to external mechanical stresses. In this work, we fabricated spray-coated mechanically robust superhydrophobic surfaces using treated titanium dioxide (Type 1) or silica particles (Type 2). Then we compared the mechanical robustness of such surfaces with the silane-coated superhydrophobic surface and PEEK coated surface using a controlled-sand blasting method. The results show that the spray-coated samples can maintain the same level of the contact angle hysteresis than silane-coated superhydorphobic surface after sand blasting at 2 bar. The spray-coating method was applied to the tube type condenser and the condensation behaviors were observed within the environmental chamber with controlled pressure, humidity and non-condensable gas. Previously-reported droplet jumping was observed in the early stage of the condensation event, but soon the droplet jumping stopped and only dropwise condensation was observed since the condensed droplets were pinned on the cracks at spray-coated surfaces. The static contact angle decreases from $158.0^{\circ}$ to $133.2^{\circ}$, and hysteresis increases from $3.0^{\circ}$ to $23.5^{\circ}$ when active condensation occurs on such surfaces. This work suggests the benefits and limitation of spray-coated superhydrophobic condensers and help develop advanced condensers for practical use.

  • PDF

A Study of Structure Monitoring Applicability of ZigBee Module through Oil Sand Plant Temperature around Canada (캐나다 오일샌드 플랜트 온도 조건을 고려한 구조물 모니터링 통신 모듈 적용성에 관한 연구)

  • Yang, Heekwon;Lee, Chankil;Lee, Bang Yong;Park, Keunbo
    • The KSFM Journal of Fluid Machinery
    • /
    • v.19 no.3
    • /
    • pp.37-42
    • /
    • 2016
  • The demand for wireless technology in plant structure has recently been increasing due to several advantages such as installation cost reduction, easy placement, easy extension and aesthetic benefits. Among the many wireless technologies, ZigBee is one of the most useful for plant structure; a wireless plant networking system can be configured using ZigBee alone. This research proposes a ZigBee to use for extreme cold region and thereby enable integration of wired and wireless plant monitoring systems. In this study, in order to assess the performance of ZigBee measured data by thermocouple were examined based on the results from laboratory tests between existing ZigBee and developed ZigBee. From the experiment results, performance of developed ZigBee in harsh environment can be increased well.

Advanced Water Treatment by Ozonation in a Continuous Flow System (연속식 오존접촉조에서의 정수처리효과에 대한 연구)

  • Lee, Byung-Ho;Jung, Woo-Sung;Kim, Jae-Hoon;Lee, Jun-Hee;Kim, Tae-Gun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.11 no.2
    • /
    • pp.94-104
    • /
    • 1997
  • Ozone Treatment is getting a common process in a water treatment plant all over the nation. Especially an advanced water treatment using ozone and biofiltration has been a typical method in the regions where using the Nak-Dong River as a drinking water source. The effectiveness of ozone treatment in a continuous flow contact system was investigated with sand filtered water of the Nak-dong River. Pilot tests of the experiments were performed three times of the year like June, August, and October 1995. Most degradable organics of sand filtered water were oxidized in the first and second contact chamber of the system. Ozone treatment was effective for the removal of UV254 absorbance. However, Noticeable removals of $KMnO_4$ demand and TOC(Total Organic Carbon) were occurred when their concentrations exceeded about 5mg/l. The organics causing $KMnO_4$ demand and TOC were degraded into lower molecular matter in an early stage of the ozone contact in the system. Dissolved oxygen concentration was increased after ozone treatment.

  • PDF

Microscopic research on the olfactory organ of the Far Eastern brook lamprey Lethenteron reissneri (Pisces, Petromyzontidae)

  • Hyun-Tae Kim;Jong-Young Park
    • Applied Microscopy
    • /
    • v.50
    • /
    • pp.18.1-18.7
    • /
    • 2020
  • The olfactory anatomy and histology of Lethenteron reissneri were researched using a stereo microscope, a light microscope, and a scanning electron microscope. As in other lampreys, it shows same characters as follows: i) a single olfactory organ, ii) a single tubular nostril, iii) a single olfactory chamber with gourd-like form, iv) a nasal valve, v) a nasopharyngeal pouch, vi) a sensory epithelium (SE) of continuous distribution, vii) a supporting cells with numerous long cilia, viii) an accessory olfactory organ. However, the description of a pseudostratified columnar layer in the SE and Non SE is a first record, not reported in sea lamprey Petromyzon marinus. In particular, both 19 to 20 lamellae in number and olfactory receptor neuron's quarter ciliary length of the knob diameter differ from those of P. marinus. From these results, it might be considered that the olfactory organ of L. reissneri shows well adaptive structure of a primitive fish to slow flowing water with gravel, pebbles, and sand and a hiding habit into sand bottom at daytime. The lamellar number and neuron's ciliary length may be a meaningful taxonomic character for the class Petromyzonida.

Effect of CO2 Injection in SAGD Process for Oil Sand Bitumen Recovery (고온 고압 스팀을 주입하는 SAGD 공정에서 CO2주입이 오일샌드 역청 회수율에 미치는 영향)

  • Song, Byung Jin;You, Nansuk;Lee, Jae Hoon;Lee, Chul Wee
    • Applied Chemistry for Engineering
    • /
    • v.25 no.3
    • /
    • pp.262-267
    • /
    • 2014
  • SAGD (steam assisted gravity drainage) process is the most commonly used in-situ technology for the recovery of bitumen from oil sand. It was investigated that the effects of different additives on bitumen recovery rate from oil sand in SAGD process among many possible mechanisms studied throughout the study. Bitumen recovery from thin layer oil sand reservoirs was simulated by using an experimental SAGD apparatus with scale of 150:1. To improve the simulation accuracy of thin layer oil reservoir, we have attached geological model (GM). Oil sand was simulated by using a mixture of extra heavy oil and glass beads with a diameter of 1.5 mm. $CO_2$ was used as an additive and the evolution of steam chambers were closely monitored, and the effects of $CO_2$ as an additive was investigated. Two types of injection methods were tested; continuous ($cCO_2$-SAGD) and sequential interruption ($sCO_2$-SAGD) $CO_2$ injection. For the $sCO_2$-SAGD experiment, it was observed that the recovery rates and CSOR were efficiently improved control experiment from 60.2% to 69.3% and 7.1 to 6.0, respectively, whereas $cCO_2$-SAGD experiment decreased from 60.2% to 57.6% and 7.1 to 7.3.