• Title/Summary/Keyword: Sampling technique

Search Result 1,309, Processing Time 0.029 seconds

An Offset Reduction Technique of High Speed Dynamic latch comparator (고속 다이나믹 래치 비교기의 오프셋 최소화 기법)

  • 현유진;성광수;서희돈
    • Proceedings of the IEEK Conference
    • /
    • 2000.11b
    • /
    • pp.160-163
    • /
    • 2000
  • In this paper, we propose an efficient technique to minimize the input offset of a dynamic latch comparator. We analyzed offset due to charge injection mismatching and unwanted positive feedback during sampling phase. The last one was only considered in the previous works. Based on the analysis, we proposed a modified dynamic latch with initialization switch. The proposed circuit was simulated using 0.65$\mu\textrm{m}$ CMOS process parameter with 5v supply. The simulation results showed that the input offset is less than 5mv at 200㎒ sampling frequency and the input offset is improved about 80% compared with previous work in 5k$\Omega$ input resistance.

  • PDF

The Real-Time Control Technique Over the Environment of Windows Using Virtual Machine Driver (가상머신 드라이브를 이용한 윈도우즈 환경에서의 실시간 제어기법)

  • Chang, Sung-ouk;Lee, Jin-Kul
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.8 no.1
    • /
    • pp.1-4
    • /
    • 2002
  • We studied the technique which can control the real system without additional hardware drivers using virtual machine driver operated on the windows operating system. We showed the feasibility of the proposed scheme under the error and the delay of a sampling time on the multi task processing through the load test of the experiment using graphic user interface.

Fiber Laser based Fiber Bragg Grating Strain Sensor (광섬유 레이저를 이용한 광섬유격자 스트레인 센서)

  • Kim, Jong-Seop;Park, Hyoung-Jun;Song, Min-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1936-1938
    • /
    • 2002
  • A tunable fiber laser and the Quadrature Sampling technique are used to construct highly sensitive fiber-optic distributive Bragg grating strain sensor system. By using a wavelength-modulated fiber laser, the variations of strain-dependent Bragg wavelengths are transformed into the variations of time-domain reflection profiles. The locations of profile peaks that correspond to the applied strains are demodulated using a precise wavelength encoder that uses a fiber-optic Mach-Zehnder interferometer and Quadrature Sampling technique. With the extremely high sensitive optical encoder, we could obtain not only high sensitivity, but also very linear responses that was impossible with the conventional techniques. This paper is attempted to report the theoretical and experimental results.

  • PDF

Minimization of Motion Artifact During Exercise in Impedance Cardiography (임피던스 심장기록법에서 운동으로 인한 Motion Artifact의 최소화)

  • Kim, Jung-Chan;Kim, Jeong-Yeol;Kim, Deok-Won;Youn, Dae-Hee
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1989 no.05
    • /
    • pp.71-73
    • /
    • 1989
  • The origins of the motion artifact resulting from exercise in impedance cardiography wore explained and the ensemble average technique was applied to reduce the motion artifact enabling the measurement of cardiac output during exercise. Algorithm for ensemble average was developed and applied to the actual impedance signals. It was found that the minimum number of sampling was 20, and sampling frequency was 500Hz. Using the ensemble average technique it was possible to measure cardiac output continuously during the treadmill exercise. Therefore it is hoped that this study may contribute in the area of exercise physiology and sport medicine.

  • PDF

A Study on the Analysis of the Output Waveform of Three-Phase Regular Sampling PWM Inverter (3상 레귤러 샘플링 PWM 인버터의 출력파행 분석에 관한 연구)

  • 노창주
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.28 no.3
    • /
    • pp.274-285
    • /
    • 1992
  • Among various Power converters, a variable voltage variable frequency (VVVF) three-phase PWM inverter is regarded as most promising power converter due to its capabilities, which permits the control of voltage, frequency and harmonic contents in a single power stage employing only on DC source. As a modulating technique of the PWM inverter, the regular sampling technique has rendered possible the on-line computation and generation of PWM control waveforms with a reasonably high switching frequencies. In this paper, microprocessor based three-phase regular samping PWM inverter with real-time control algorithm and control circuits for driving three phase AC motor has been developed. Harmocic components of PWM waveform were analized theoretically in terms of Bessel function series and then calculated by digital computer and observed with spectrum analyzer.

  • PDF

Comparison of Sampling Techniques for Passive Internet Measurement: An Inspection using An Empirical Study (수동적 인터넷 측정을 위한 샘플링 기법 비교: 사례 연구를 통한 검증)

  • Kim, Jung-Hyun;Won, You-Jip;Ahn, Soo-Han
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.45 no.6
    • /
    • pp.34-51
    • /
    • 2008
  • Today, the Internet is a part of our life. For that reason, we regard revealing characteristics of Internet traffic as an important research theme. However, Internet traffic cannot be easily manipulated because it usually occupy huge capacity. This problem is a serious obstacle to analyze Internet traffic. Many researchers use various sampling techniques to reduce capacity of Internet traffic. In this paper, we compare several famous sampling techniques, and propose efficient sampling scheme. We chose some sampling techniques such as Systematic Sampling, Simple Random Sampling and Stratified Sampling with some sampling intensities such as 1/10, 1/100 and 1/1000. Our observation focused on Traffic Volume, Entropy Analysis and Packet Size Analysis. Both the simple random sampling and the count-based systematic sampling is proper to general case. On the other hand, time-based systematic sampling exhibits relatively bad results. The stratified sampling on Transport Layer Protocols, e.g.. TCP, UDP and so on, shows superior results. Our analysis results suggest that efficient sampling techniques satisfactorily maintain variation of traffic stream according to time change. The entropy analysis endures various sampling techniques well and fits detecting anomalous traffic. We found that a traffic volume diminishment caused by bottleneck could induce wrong results on the entropy analysis. We discovered that Packet Size Distribution perfectly tolerate any packet sampling techniques and intensities.

Latin Hypercube Sampling Based Probabilistic Small Signal Stability Analysis Considering Load Correlation

  • Zuo, Jian;Li, Yinhong;Cai, Defu;Shi, Dongyuan
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.6
    • /
    • pp.1832-1842
    • /
    • 2014
  • A novel probabilistic small signal stability analysis (PSSSA) method considering load correlation is proposed in this paper. The superiority Latin hypercube sampling (LHS) technique combined with Monte Carlo simulation (MCS) is utilized to investigate the probabilistic small signal stability of power system in presence of load correlation. LHS helps to reduce the sampling size, meanwhile guarantees the accuracy and robustness of the solutions. The correlation coefficient matrix is adopted to represent the correlations between loads. Simulation results of the two-area, four-machine system prove that the proposed method is an efficient and robust sampling method. Simulation results of the 16-machine, 68-bus test system indicate that load correlation has a significant impact on the probabilistic analysis result of the critical oscillation mode under a certain degree of load uncertainty.

General Regression Estimators in Survey Sampling (표본조사에서 일반회귀 추정량의 활용)

  • Kim, Kyu-Seong
    • Survey Research
    • /
    • v.5 no.2
    • /
    • pp.49-70
    • /
    • 2004
  • This paper is a broad review about general regression estimators, which are very useful when auxiliary variables are available in survey sampling. We investigate the process of development of general regression estimators from birth to suggestion of variance estimation method and examine some properties of general regression estimators by comparing with calibration and QR estimators. We also present some forms of general regression estimators available under complex sampling designs such as stratified sampling and cluster sampling. Finally, we comment some advantages as well as disadvantages of general regression estimators and theoretical and practical development in the future.

  • PDF

Development of Small-Specimen Creep Tester for Life Assessment of High Temperature Components of Power Plant (발전소 고온부의 수명 평가를 위한 소형 시편용 크리프 시험기의 개발)

  • Kim, Hyo-Jin;Jeong, Yong-Geun;Park, Jong-Jin
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.10 s.181
    • /
    • pp.2597-2602
    • /
    • 2000
  • The most effective means of evaluating remaining life is through the creep testing of samples removed from the component. But sampling of large specimen from in-service component is actually impossible. So, sampling device and small-specimen creep tester have been applied. Sampling device has been devised to extract mechanically small samples by hemispherical, diamond -coated cutter from the surface of turbine rotor bores and thick-walled pipes without subsequent weld repairs requiring post weld heat treatment. A method of manufacturing small creep specimen, 2min gage diameter and 10min gage length, using electron beam welding to attach grip section, has been proven. Small-specimen creep tester has been designed to control atmosphere to prevent stress increment by oxidation during experiment. To determine whether the small specimens successfully reproduce the behavior of large specimens, creep rupture tests for small and large specimens have been performed at identical conditions. Creep rupture times based on small specimens have closely agreed within 5% error compared with that of large specimen. The errors in rupture time have decreased at longer test period. This comparison validates the procedure for fabricating and testing on small specimen. This technique offers potential as an efficient method for remaining life assessment by direct sampling from in -service high temperature components.

On a Multiband Nonuniform Samping Technique with a Gaussian Noise Codebook for Speech Coding (가우시안 코드북을 갖는 다중대역 비균일 음성 표본화법)

  • Chung, Hyung-Goue;Bae, Myung-Jin
    • The Journal of the Acoustical Society of Korea
    • /
    • v.16 no.6
    • /
    • pp.110-114
    • /
    • 1997
  • When applying the nonuniform sampling to noisy speech signal, the required data rate increases to be comparable to or more than that by uniform sampling such as PCM. To solve this problem, we have proposed the waveform coding method, multiband nonuniform waveform coding(MNWC), applying the nonuniform sampling to band-separated speech signal[7]. However, the speech quality is deteriorated when it is compared to the uniform sampling method, since the high band is simply modeled as a Gaussian noise with average level. In this paper, as a good method to overcome this drawback, the high band is modeled as one of 16 codewords having different center frequencies. By doing this, with maintaining high speech quality as MOS score of average 3.16, the proposed method achieves 1.5 times higher compression ratio than that of the conventional nonuniform sampling method(CNSM).

  • PDF