• Title/Summary/Keyword: Sampling efficiency

Search Result 613, Processing Time 0.028 seconds

The Sampling Efficiencies of Volatile Organic Compounds(VOCs) to the Diffusive Monitor with Activated Carbon Fiber (활성탄섬유를 이용한 확산포집기의 공기 중 유기용제 포집효율에 관한 연구)

  • Byeon, Sang-Hoon;Park, Cheon-Jae;Oh, Se-Min;Lee, Chang-Ha
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.6 no.2
    • /
    • pp.187-201
    • /
    • 1996
  • This study was to evaluate the efficiency of diffusive monitor using activated carbon fiber(ACF, KF-1500) in measuring airborne organic solvents. The following characteristics were identified and studied as critical to the performance of diffusive monitor; recovery, sampling rate, face velocity, reverse diffusion and storage stability. For the evaluation of the performance of this monitor, MIBK, PCE, toluene were used as organic solvents. In the sampling rate experiments, eight kinds of solvents (n-hexane, MEK, DIBK, MCF, TCE, CB, xylene, cumene) as well as the above solvents were used. The results were as follows: 1. The desorption efficiencies(DE's) of ACF diffusive monitor ranged from 83 % to 101 %. In contrast, those of coconut shell charcoal ranged from 78 % to 102 %. Especially, the DE's of ACF for the polar solvents such as MEK were superior to those of charcoal. 2. Experimental sampling rates on ACF were average 42ml/min(37-46ml/min) for 11 organic solvents at $24{\pm}2^{\circ}C$, $50{\pm}5%RH$. However ideal sampling rates(DA/L) were 33 % higher than experimental sampling rates. 3. The initial response(15~16 min) of the testing monitor was 2 times higher than the actual concentration determined by the reference methods at $24{\pm}2^{\circ}C$, $8{\pm}5%RH$ and $80{\pm}5%RH$. Within 1 hours, the curve reached a linear horizontal line at low humidity condition. But sampling efficiencies decreased with respect to time at high humidity condition. And sampling efficiencies were higher at high humidity condition than low humidity condition for MIBK. 4. At very low velocity (less than 0.02 m/sec), the concentration of ACF diffusive monitor were poorly estimated. But ACF diffusive monitor were not affected at higher velocity(0.2 m/sec-0.6 m/sec). 5. There was no significant reverse diffusion when the ACF monitors were exposed to clean air for 2 hours after being exposed for 2 hours at the level of 1 TLV. 6. There was no significant sample loss during 3 weeks of storage at room temperature and 5 weeks of storage at refrigeration.

  • PDF

Statistical Efficiency of Sampling Plot Size in Half-sib Progeny Test of Korean Pine (Pinus koraiensis S. et Z.) (잣나무 차대검정(次代檢定)에 있어서의 효율적(效率的)인 Plot Sampling에 관(關)한 연구(硏究))

  • Kim, Dae Eun;Chon, Sang Keun
    • Journal of Korean Society of Forest Science
    • /
    • v.80 no.4
    • /
    • pp.379-382
    • /
    • 1991
  • Tree height at age 10 was used to estimate the statistical efficiencies of sampling size in the progeny test of Pinus koraiensis S. et Z. Experimental design was RCB design which consists of 25 half-sib families in each of three blocks. The number of families and blocks were fixed, therefore, the number of trees sampled per plot was the only factor that influences the environmental portion of the family mean height. Coefficient of variation, the estimate of the standard error of the family mean height, decreased with increase of sampling plot size, and became stable from 4-tree plot sampling (6.97%). The experimental error was significant from 7-tree sampling plot size. Nonlinear relationship (${\hat{Y}}=10.425e-^{0.073x}$ ; $R^2$=0.840) was found between the sampling plot size and the standard error of family mean height.

  • PDF

Probability Sampling to Select Polling Places in Exit Poll (출구조사를 위한 투표소 확률추출 방법)

  • Kim, Young-Won;Uhm, Yoon-Hee
    • Survey Research
    • /
    • v.6 no.2
    • /
    • pp.1-32
    • /
    • 2005
  • The accuracy of exit poll mainly depends on the sampling method of voting places. For exit poll, we propose a probability sampling method of selecting voting places as an alternative to the bellwether polling place sampling. Through an empirical study based on the 2004 general election data, the efficiency of the suggested systematic sampling from ordered voting places was evaluated in terms of mean prediction error and it turns out that the proposed sampling method outperformed the bellwether polling places sampling. We also calculated the variance of estimator from the proposed sampling, and considered the sample size problem to guarantee the target precision using the design effect of the proposed sample design.

  • PDF

Effects of temperature and relative humidity on the sampling efficiencies of mixed organic vapors measured by diffusion monitors (확산 포집기로 공기중 혼합유기용제 포집시 온도와 상대습도가 포집효율에 미치는 영향)

  • Han, Jin gu;Roh, Young Man;Kim, Hyun Wook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.5 no.2
    • /
    • pp.200-211
    • /
    • 1995
  • This study was designed to evaluate the effects of temperature and humidity on the sampling efficiency of mixed organic vapors of l,2-DCE, benzene, and MIBK by 3 different types of diffusion monitors. Independent variables used for the study were temperatures ($25^{\circ}C$, $35^{\circ}C$), humidities (30%, 80%), and vapor concentrations (low, medium, and high). In addition, vapor concentrations measured by the traditional charcoal tube method were used as reference values and were compared with those of by diffusion monitors. The results were as follows: 1. The desorption efficiencies(DE) of 1,2-DCE and benzene from charcoal tubes and from diffusion monitors ranged from 98% to 105%. In contrast, the DEs of MIBK from charcoal tubes and diffusion monitors except DM1 ranged from 71% to 85%. The DE of MIBK from DM1 was 98%. 2. No statistically significant differences of 1,2-DCE concentrations and the sampling efficiencies regardless of temperatures and humidities studied between charcoal tube and 3 diffusion monitors were found. 3. At 80% humidity, increasing frequencies of 1,2-DCE breakthrough at higher temperature and higher vapor concentration measured by charcoal tubes were observed. 4. No statistically significant difference of benzene concentrations were found between charcoal tube and diffusion monitors except DM3. The sampling efficiencies of DM3 were statistically significantly lower at all experimental conditions except the $35^{\circ}C$ and 30% humidity condition. 5. No statistically significant difference of MIBK concentrations were found between charcoal tube and diffusion monitors except DM3. The sampling efficiencies of DM3 were statistically significantly higher at higher humidity conditions regardless of temperature. Although statistically not significant, sampling efficiency of MIBK showed positive correlation with humidity while negative correlation with concentration was observed. 6. For sampling 1,2-DCE and benzene, no significant variations of concentrations among three diffusion monitors regardless of temperature and humidity conditions were found. For MIBK sampling, however, wide variations with increasing humidity among diffusion monitors were obtained. In conclusion, this study suggests that diffusion monitors will be a reasonables substitute for the traditional charcoal tubes for sampling non-polar organic vapors at temperature and humidity conditions studied. For polar organic vapors, use of an alternative desorption solution other than CS2 is recommended because of its low desorption efficiency. In addition, since variable among diffusion monitors for polar organic vapors particularly at higher humidity conditions were observed, further study is recommended of the effects of humidity on the performance of diffusion monitors.

  • PDF

Unrelated question model with quantitative attribute by stratified double sampling (층화이중추출법에 의한 양적속성의 무관질문모형)

  • 이기성;홍기학
    • The Korean Journal of Applied Statistics
    • /
    • v.8 no.1
    • /
    • pp.27-38
    • /
    • 1995
  • In the surveys of sensitive issues of the population that is composed of several unknown-size stratum, we propose the unrelated question model with quantitative attribute by using stratified double sampling. And, we consider two types of sample allocations under the fixed cost, which are the proportional allocation, the optimum allocation. In efficiency, the proosed model is inferior to the unrelated question model with quantitative attribute by stratified sampling in case of the size of each stratum is known. But we find that efficiency of the proposed model is increased, when the selecting probability of sensitive question p is small and first stage sample size n' is large.

  • PDF

Evaluation of Primary Clarifier by Wastewater TSS Characterization (수질 특성(TSS) 파악을 통한 1차 침전지 성능 평가 (TSS 농도를 중심으로))

  • Lee, Byonghi
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.3
    • /
    • pp.363-369
    • /
    • 2009
  • In order to evaluate primary clarifier performance on TSS(Total Suspended solids) removal, four different sampling sets were collected as part of this study; (1) weekly test, (2) the diurnal sampling, (3) the settling velocity distribution sampling. Primary effluent TSS($TSS_{PE}$) and non settleable TSS($TSS_{NON}$) concentrations were averaged 160 and 75.5 mg/L, respectively. These data suggest approximately 85 mg/L TSS can be removed more. Average $TSS_{NON}$, $TSS_{PE}$, and Dispersed TSS(DTSS) concentrations(75.5, 160, and 104 mg/L, respectively) suggest that 28.5 mg/L of TSS difference attributable to poor flocculation, whereas 56 mg/L of TSS difference attributable to poor hydraulics within primary clarifier. In this study, equations for maximum TSS removal efficiency and effluent TSS concentration were suggested and compared with experimented data.

Collection Characteristics of a MOUDI Cascade Impactor for Coarse Particles (다단 임팩터(MOUDI)의 조대 입자 채취 특성)

  • 배귀남;지준호;문길주
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.15 no.6
    • /
    • pp.799-804
    • /
    • 1999
  • Particle collection characteristics of the MOUDI cascade impactor has been studied for coarse particles in the range of 2 to 20$mu extrm{m}$ in aerodynamic diameter. A vibrating orifice aerosol generator was empolyed to generate monodisperse test aerosols. The oleic acid and sodium chloride(NaCl) particles were used as test aerosols. Aluminum foil and Teflon filter were selected as impaction media. The sampling flow rate was changed from 25 to 35L/min. Particle collection efficiency for single stage was examined for liquid particles. The stage response was obtained experimentally for the cascade impactor composed of three stages and a backup filter. The results showed that most of particle collection efficiencies measured in this work are similar to the efficiency curves obtained by Marple et al.(1991). For particles less than cut-off size of the stage, the collection efficiencies of solid particles are similar to those of loquid particles. However, the collection efficiency of solid particles decreases with mereasing particle diameter for the particles greater than the actual cut-off size of the impactor. The particle collection efficiency increases with increasing sampling flow rate at the same particel size. However, the collection efficiency curves seem not to be greatly shifted with the flow rate. The stage responses obtained by direct measurements in this work are in good agreement with those derived from the collection efficiency curves for single stage.

  • PDF

Multistage Point and Confidence Interval Estimation of the Shape Parameter of Pareto Distribution

  • Hamdy, H.I.;Son, M.S.;Gharraph, M.K.;Rashad, A.M.
    • Communications for Statistical Applications and Methods
    • /
    • v.10 no.3
    • /
    • pp.1069-1086
    • /
    • 2003
  • This article presents the asymptotic theory of triple sampling procedure as pertain to estimating the shape parameter of Pareto distribution. Both point and confidence interval estimation are considered within the same inference unified framework. We show that this group sampling technique possesses the efficiency of Anscome (1953), Chow and Robbins (1965) purely sequential procedure as well as reduce the number of sampling operations by utilizing Stein (1945) two stages procedure. The analysis reveals that the technique performs excellent as far as the accuracy is concerned. The present problem differs from those considered by many authors, in multistage sampling, in that the final stage sample size and the parameter's estimate become highly correlated and therefore we adopted different approach.

Efficiency of Variance Estimators for Two-stage PPS Systematic Sampling (2단 크기비례 계통추출법의 분산추정량 효율성 비교)

  • Kim, Young-Won;Kim, Yeny;Han, Hye-Eun;Kwak, Eun-Sun
    • The Korean Journal of Applied Statistics
    • /
    • v.26 no.6
    • /
    • pp.1033-1041
    • /
    • 2013
  • In this paper, we investigate several variance estimators for pps systematic sampling. Unfortunately, there is no unbiased variance estimators for a systematic sample because systematic sampling can be regarded as a random selection of one cluster. This study provides guidance on which variance estimator may be more appropriate than others in several circumstances. We judge the efficiency of variance estimators for systematic sampling based on of their relative biases and relative mean square error. Also, we investigate variance estimation problems for two-stage systematic sampling applied for the Food Raw Material Consumption Survey and the Establishment Labor Force Survey simulation study, in order to consider the popular two-stage pps systematic sample design for establishment and household survey in Korea.