• Title/Summary/Keyword: Sampling and analytical method

Search Result 167, Processing Time 0.031 seconds

Seismic Vulnerability Assessment of RC Frame Structures Using 3D Analytical Models (3차원 해석 모델을 이용한 RC 프레임 구조물의 지진 취약도 평가)

  • Moon, Do-Soo;Lee, Young-Joo;Lee, Sangmok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.9
    • /
    • pp.724-731
    • /
    • 2016
  • As the structural damage caused by earthquakes has been gradually increasing, estimating the seismic fragility of structures has become essential for earthquake preparation. Seismic fragility curves are widely used as a probabilistic indicator of structural safety against earthquakes, and many researchers have made efforts to develop them in a more accurate and effective manner. However, most of the previous research studies used simplified 2D analytical models when deriving fragility curves, mainly to reduce the numerical simulation time; however, in many cases 2D models are inadequate to accurately evaluate the seismic behavior of a structure and its seismic vulnerability. Thus, this study provides a way to derive more accurate, but still effective, seismic fragility curves by using 3D analytical models. In this method, the reliability analysis software, FERUM, is integrated with the structural analysis software, ZEUS-NL, enabling the automatic exchange of data between these two software packages, and the first order reliability method (FORM), which is not a sampling-based method, is utilized to calculate the structural failure probabilities. These tools make it possible to conduct structural reliability analyses effectively even with 3D models. By using the proposed method, this study conducted a seismic vulnerability assessment of RC frame structures with their 3D analytical models.

Optimal Sampling Times of Once Daily Gentamicin in Korean Patients with Urinary Tract Infections

  • Park, Hyo-Jung;Sohn, Kie-Ho;Choi, Kyung-Eob;Shin, Sang-Yup;Jung, Sook-In;Oh, Won-Sup;Peck, Kyong-Ran;Song, Jae-Hoon;Lee, Suk-Hyang
    • Biomolecules & Therapeutics
    • /
    • v.11 no.3
    • /
    • pp.178-182
    • /
    • 2003
  • The clinical use of once daily aminoglycoside (ODA) dosing has been increased because of the potential therapeutic advantages of this dosing regimen. To evaluate the optimal sampling times of ODA dosing method in a clinical setting, the study was prospectively conducted in a total of 28 patients with UTI. All of the patients were intravenously administered gentamicin at a dose of 7 mg/kg over 60 minutes and randomly divided into two groups. Blood was collected at 0, 2, and 6 hours in Group A and at 1, 2, and 6 hours in Group B after the end of 1-hour infusion. The pharmacokinetic parameters (Ke, Vd and Cmax) obtained using the 0, 6 hour levels and 2, 6 hour levels in Group A were statistically different while those of 1, 6 hour levels and 2, 6 hour levels in Group B were similar. This finding indicated that the distributional phase of ODA is completed within 1 hour following the end of the I-hour infusion. If we are allowed to collect only two blood samples in ODA considering patients comfort and the analytical cost of drug, the first one should be drawn after 1 hour following the end of infusion to obtain adequate pharmacokinetic information.

Analysis of fatty acid methyl ester in bio-liquid by hollow fiber-liquid phase microextraction

  • Choi, Minseon;Lee, Soyoung;Bae, Sunyoung
    • Analytical Science and Technology
    • /
    • v.30 no.4
    • /
    • pp.174-181
    • /
    • 2017
  • Bio-liquid is a liquid by-product of the hydrothermal carbonization (HTC) reaction, converting wet biomass into solid hydrochar, bio-liquid, and bio-gas. Since bio-liquid contains various compounds, it requires efficient sampling method to extract the target compounds from bio-liquid. In this research, fatty acid methyl ester (FAME) in bio-liquid was extracted based on hollow fiber supported liquid phase microextraction (HF-LPME) and determined by Gas Chromatography-Flame Ionization Detector (GC-FID) and Gas Chromatography/Mass Spectrometry (GC/MS). The well-known major components of biodiesel, including methyl myristate, palmitate, methyl palmitoleate, methyl stearate, methyl oleate, and methyl linoleate had been selected as standard materials for FAME analysis using HF-LPME. Physicochemical properties of bio-liquid was measured that the acidity was 3.30 (${\pm}0.01$) and the moisture content was 100.84 (${\pm}3.02$)%. The optimization of HF-LPME method had been investigated by varying the experimental parameters such as extraction solvent, extraction time, stirring speed, and the length of HF at the fixed concentration of NaCl salt. As a result, optimal conditions of HF-LPME for FAMEs were; n-octanol for extraction solvent, 30 min for extraction time, 1200 rpm for stirring speed, 20 mm for the HF length, and 0.5 w/v% for the concentration of NaCl. Validation of HF-LPME was performed with limit of detection (LOD), limit of quantitation (LOQ), dynamic range, reproducibility, and recovery. The results obtained from this study indicated that HF-LPME was suitable for the preconcentration method and the quantitative analysis to characterize FAMEs in bio-liquid generated from food waste via HTC reaction.

Experimental Study on Axial Stratification Process and Its Effects (I) - Stratification in Engine -

  • Ohm, In-Yong;Park, Chan-Jun
    • Journal of Mechanical Science and Technology
    • /
    • v.16 no.11
    • /
    • pp.1457-1469
    • /
    • 2002
  • This paper is the first of several companion papers, which investigate axial stratification process and its effects in an Sl engine. The axial stratification is very sophisticate phenomenon, which results from combination of fuel injection, port and in-cylinder flow and mixing. Because of the inherent unsteady condition in the reciprocating engine, it Is impossible to understand the mechanism through the analytical method. In this paper, the ports were characterized by swir and tumble number in steady flow bench test. After this, lean misfire limit of the engines, which had different port characteristic, were investigated as a function of swirl ratio and injection timing for confirming the existence of stratification. In addition, gas fuel was used for verifying whether this phenomenon depends on bulk air motion of cylinder or on evaporation of fuel. High-speed gas sampling and analysis was also performed to estimate stratification charging effect. The results show that the AFR at the spark plug and LML are very closely related and the AFR is the results of bulk air motion.

Interpretation of Analytical Data of Ion Components in Precipitation, Seoul (서울 地域 降水中 이온成分 分析資料의 解析)

  • 강공언;이주희;김희강
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.12 no.3
    • /
    • pp.323-332
    • /
    • 1996
  • Precipitation samples were collected by the wet-only sampling method at Seoul from September 1993 to June 1995. Sample were analysed for the anions $(NO_3^-, NO_2^-, SO_4^{2-}, Cl^-, and F^-)$ and cations $(Na^+, K^+, Ca^{2+}, Mg^{2+}, and NH_4^+)$ in addition to pH and electric conductivity. In order to establish the chemical analysis data of high quality, the assurance checks for analytical data of precipitation were performed by considering the ion balance and by comparing the measured conductivity with the calculated conductivity. As we applied the various assurance checking methods by the ion balance used until recently to a data set measured in this study, the f value expressed as $\Sigma C/\Sigma A$ was found to be not appropriate for the data screening. Also, the scattering plot between cations and anions in each sample was found to show the general tendency of ion balance but was proved to not quantitate the standard of data screening at a data set of samples of various concentration levels. The h value defined as (A-C)/C for C $\geq$ A and (A-C)/A for C < A was used to check the ion balance. However, the standard of data screening by h value must very in response to total ion concentration of samples. In this study, the quality assurance of chemical analysis data was checked by considering both the ion balance of evaluating by h value and the conductivity balance. Further the quality control was achieved by these quality assurance methods. As the result, 67 samples among total 77 were obtained as valid. As the central tendency value for a statistical summary in the analytical parametr of samples, the volume-weighted mean value was found to represent more the general chemistry of precipitation rather than the arithmetic mean. The volume-weighted mean pH was 5.0 and 25% of samples was less than this mean. The concentrations of sufate and nitrate in precipitation were 90.4 ueq/L and 32.4 ueq/L which made up 59% and 21% of all anions. The raion of $SO_4^{2-}/(NO_3^- + NO_2^-)$ in precipitation was 2.7, which indicates that the contributions of $H_2SO_4$ and $HNO_3$ to the acidity of precipitation are 70% and 30%, respectively.

  • PDF

Exhaled breath Analysis for Body Burden Estimates of Aromatic Volatile Organic Compounds

  • Jo, Wan-Kuen;Song, Ki-Bum;Nam, Chang-Mo
    • Environmental Sciences Bulletin of The Korean Environmental Sciences Society
    • /
    • v.4 no.1
    • /
    • pp.25-29
    • /
    • 2000
  • The present study evaluated the body burden of aromatic VOCs in roadside and underground storekeepers. The Method Detection Limit(MDL) of the analytical system ranged from 0.2 to 0.4$\mu\textrm{g}$/m3 for the target VOCs. The recovery of the sampling system for the compounds was above 80%. For all the target compounds, the breath concentrations of the smokes were similar to or slightly higher than those of the nonsmokers for both the roadside and underground storekeepers. For Ethylbenzene, p-Xylene, and o-Xylene, the breath concentrations of the underground storekeepers were somewhat higher than those of the roadside storekeepers. In contrast, the breath m-xylene concentration of underground storekeepers was similar to that of roadside storekeepers. For both the roadside and underground storekeepers, the breath concentrations prior to and after work were not significantly different.

  • PDF

COMBUSTION TOXICITY ANALYSIS: ADVANCES USING A SPECIALIZED SAMPLING TECHNIQUE FOR FOURIER TRANSFORM INFRARED (FTIR) ANALYSIS

  • Talandis, Jonas;Innes, J.D.;Cox, A.W.
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.178-184
    • /
    • 1997
  • The cone calorimeter as defined by ISO 5660, ASTM 1354, and NFPA 264A is used to assess the reaction to fire of almost any material that must be evaluated in the fire science field. Typical combustion gas analyses include oxygen, CO and CO2. Oxygen consumption is used to determine rate of heat release. Analysis of combustion gases other than oxygen, CO and CO2 has been attempted using filters to remove the solid smoke particles before analysis. This method has generated unreliable results due to the adsorption of many gas components on the active carbon . particles deposited on the filters. A technique using fourier Transform Infrared (FTIB) analysis without filtration will be disclosed and a discussion will be presented of the analytical results of toxic gases produced from various flame retarded polymeric materials. Use of such data in lethal toxic potency determinations is also reviewed.

  • PDF

A Study on the Preference Attributes for Silver Town Development (실버타운 개발을 위한 선호속성에 관한 연구)

  • Ha, Jeung-Soon;Cho, Joo-Hyun
    • Journal of the Korean housing association
    • /
    • v.18 no.3
    • /
    • pp.103-113
    • /
    • 2007
  • The purpose of this study is calling attention to the silver town by analyse preference attributes diversely and suggest alterative plan. Also, offering basic data which needs for the establishment of comfortable and ideal old age residence culture by developing silver town which is appropriate for our circumstances and emotion. The survey population of this study focused on 40s and 50s' middle aged both genders living in the Seoul and national capital region, we used random sampling method. The analytical methods used in this study were frequency, mean, standard deviation, Factor Analysis, t-test, ANOVA, post-hoc estimation (Duncan test), multiple regression, To verify the reliability of each measure, Cronbach's alpha coefficient was used.

Measurements of Trimethylamine (TMA) in air by Tedlar bag sampling and SPME analysis (환경대기 중 Trimethylamine (TMA)의 측정: Tedlar bag 방식의 채취와 SPME 분석법의 특성 연구)

  • Kim, K.H.;Hyum, S.H.;Im, M.S.
    • Analytical Science and Technology
    • /
    • v.19 no.1
    • /
    • pp.96-102
    • /
    • 2006
  • Trimethylamine (TMA) is one of the difficult odorous compounds for the collection and analysis. Although sulfuric acid absorption and/or sulfuric acid impregnated filter method are commonly recommended for its sampling, these methods also suffer from difficulties involved in sample treatment and operational procedures. Hence, as an ancillary approach to measure TMA, we investigated the combination of bag sampling and SPME analysis for TMA measurements. For the purpose of our study, we investigated the following three subjects: 1) temporal variability of standard storage, 2) bag loss effect of TMS, and 3) TMA loss due to repetitive analysis of an identical bag sample. According to our storage test up to 7 or 20 dyas, TMA loss were found to occur up to 40 to 50% within relatively short period of up to 48 hrs depending on its concentration ranges. When the tests were made for bag loss by transferring TMA standards across different size bags, we were able to find that the extent of bag loss are not significant with 5 to 20% loss rate. Finally, the TMA sorptive loss via its exposure to SPME fiber was generally estimated to run from 2 to 3%.

An Introduction to Data Analysis (자료 분석의 기초)

  • Pak, Son-Il;Lee, Young-Won
    • Journal of Veterinary Clinics
    • /
    • v.26 no.3
    • /
    • pp.189-199
    • /
    • 2009
  • With the growing importance of evidence-based medicine, clinical or biomedical research relies critically on the validity and reliability of data, and the subsequent statistical inferences for medical decision-making may lead to valid conclusion. Despite widespread use of analytical techniques in papers published in the Journal of Veterinary Clinics statistical errors particularly in design of experiments, research methodology or data analysis methods are commonly encountered. These flaws often leading to misinterpretation of the data, thereby, subjected to inappropriate conclusions. This article is the first in a series of nontechnical introduction designed not to systemic review of medical statistics but intended to provide the journal readers with an understanding of common statistical concepts, including data scale, selection of appropriate statistical methods, descriptive statistics, data transformation, confidence interval, the principles of hypothesis testing, sampling distribution, and interpretation of results.